Paul David Chantler, Edward G Lakatta, and Samer S Najjar
Arterial-Ventricular Coupling: Mechanistic Insights into Cardiovascular Performance at Rest and During Exercise
J Appl Physiol 2008; 0: 90600.2008v1 [Abstract] [PDF]
*eLetters: Submit a response to this article

Electronic letters published:

[Read eLetter] Wrong formula
andre f rocher   (8 January 2009)

Wrong formula 8 January 2009
  Top
andre f rocher,
medical doctor
University of Stellenbosch

Send letter to journal:
Re: Wrong formula

aroc77{at}gmail.com andre f rocher

The formula for calculating the estimated ESP (End Systolic Pressure) is quoted wrong in the article.

[2 x (systolic BP + diastolic BP)]/3 should be (2 systolic BP + diastolic BP)/3.

Kelly RP, Ting CT, Yang TM, Liu CP, Maughan WL, Chang MS, Kass DA. Effective arterial elastance as index of arterial vascular load in humans. Circulation 86: 513–521, 1992.