Journal of Applied Physiology Information on EB 2010
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 99: 650-655, 2005. First published March 31, 2005; doi:10.1152/japplphysiol.01115.2004
8750-7587/05 $8.00
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow All Versions of this Article:
99/2/650    most recent
01115.2004v1
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tusman, G.
Right arrow Articles by Böhm, S. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tusman, G.
Right arrow Articles by Böhm, S. H.

Effect of pulmonary perfusion on the slopes of single-breath test of CO2

G. Tusman,1 M. Areta,2 C. Climente,2 R. Plit,2 F. Suarez-Sipmann,4 M. J. Rodríguez-Nieto,5 G. Peces-Barba,5 E. Turchetto,3 and S. H. Böhm6

Departments of 1Anesthesiology, 2Cardiovascular Surgery, and 3Critical Care Medicine, Hospital Privado de Comunidad, Mar del Plata, Argentina; Departments of 4Critical Care Medicine and 5Pneumonology, Fundación Jimenez Díaz, Madrid, Spain; and 6Respiratory Intensive Care Unit, Pulmonary Division, Hospital das Clínicas, University of Sao Paulo, Brazil

Submitted 5 October 2004 ; accepted in final form 28 March 2005

The objective of this study was to evaluate the effects of lung perfusion on the slopes of phases II (SII) and III (SIII) of a single-breath test of CO2 (SBT-CO2). Fourteen patients submitted to cardiac surgery were studied during weaning from cardiopulmonary bypass (CPB). Pump flow was decreased in 20% steps, from 100% (total CPB = 2.5 l·min–1·m–2) to 0%. This maneuver resulted in a progressive and opposite increase in pulmonary blood flow (PBF) while maintaining ventilator settings constant. SBT-CO2, respiratory, and hemodynamic variables remained unchanged before and after CPB, reflecting a constant condition at those stages. SIII was similar before and after CPB (19.6 ± 2.8 and 18.7 ± 2.1 mmHg/l, respectively). SIII was lowest during 20% PBF (8.6 ± 1.9 mmHg/l) and increased in proportion to PBF until exit from CPB (15.6 ± 2.2 mmHg/l; P < 0.05). Similarly, SII and the CO2 area under the curve increased from 163 ± 41 mmHg/l and 4.7 ± 0.6 ml, respectively, at 20% PBF to 313 ± 32 mmHg/l and 7.9 ± 0.6 ml (P < 0.05) at CPB end. When SII and SIII were normalized by the mean percent expired CO2, they remained unchanged during the protocol. In summary, the changes in PBF affect the slopes of the SBT-CO2. Normalizing SII and SIII eliminated the effect of changes in the magnitude of PBF on the shape of the SBT-CO2 curve.

cardiopulmonary bypass; carbon dioxide; capnography



Address for reprint requests and other correspondence: G. Tusman, Dept. of Anesthesiology, Hospital Privado de Comunidad, Cordoba 4545, 7600 Mar del Plata, Argentina (E-mail: gtusman{at}hotmail.com)




This article has been cited by other articles:


Home page
Anesth. Analg.Home page
S. H. Bohm, S. Maisch, A. von Sandersleben, O. Thamm, I. Passoni, J. M. Arca, and G. Tusman
The Effects of Lung Recruitment on the Phase III Slope of Volumetric Capnography in Morbidly Obese Patients
Anesth. Analg., July 1, 2009; 109(1): 151 - 159.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online
Copyright © 2005 by the American Physiological Society.