Journal of Applied Physiology Ad Instruments
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 98: 2242-2248, 2005. First published February 10, 2005; doi:10.1152/japplphysiol.01199.2004
8750-7587/05 $8.00
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Movie
Right arrow All Versions of this Article:
98/6/2242    most recent
01199.2004v1
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (4)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lamm, W. J. E.
Right arrow Articles by Glenny, R. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lamm, W. J. E.
Right arrow Articles by Glenny, R. W.

Intravital microscopic observations of 15-µm microspheres lodging in the pulmonary microcirculation

Wayne J. E. Lamm,1 Susan L. Bernard,1 Wiltz W. Wagner, Jr.,3,4,5 and Robb W. Glenny1,2

Departments of 1Medicine and 2Physiology and Biophysics, University of Washington, Seattle, Washington; and Departments of 3Anesthesiology, 4Cellular and Integrative Physiology, and 5Pediatrics, Indiana University School of Medicine, Indianapolis, Indiana

Submitted 25 October 2004 ; accepted in final form 20 January 2005

Vascular infusions of 15-µm-diameter microspheres are used to study pulmonary blood flow distribution. The sites of microsphere lodging and their effects on microvascular perfusion are debated but unknown. Using intravital microscopy of the subpleural surface of rat lungs, we directly observed deposition of fluorescent microspheres. In a pump-perfused lung model, ~0.5 million microspheres were infused over 30 s into the pulmonary artery of seven rats. Microsphere lodging was analyzed for the location in the microvasculature and the effect on local flow after lodging. On average, we observed 3.2 microspheres per 160 alveolar facets. The microspheres always entered the arterioles as singlets and lodged at the inlets to capillaries, either in alveolar corner vessels or small arterioles. In all cases, blood flow continued either around the microspheres or into the capillaries via adjacent pathways. We conclude that 15-µm-diameter microspheres, in doses in excess of those used in typical studies, have no significant impact on pulmonary capillary blood flow distribution.

rats; blood flow



Address for reprint requests and other correspondence: R. Glenny, Univ. of Washington, Div. of Pulmonary and Critical Care Medicine, Box 356522, Seattle, WA 98195 (E-mail: glenny{at}u.washington.edu)




This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
R. W. Glenny, S. L. Bernard, D. L. Luchtel, B. Neradilek, and N. L. Polissar
The spatial-temporal redistribution of pulmonary blood flow with postnatal growth
J Appl Physiol, March 1, 2007; 102(3): 1281 - 1288.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online
Copyright © 2005 by the American Physiological Society.