Journal of Applied Physiology Ad Instruments
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 95: 1808-1816, 2003. First published June 20, 2003; doi:10.1152/japplphysiol.00362.2003
8750-7587/03 $5.00
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow All Versions of this Article:
95/5/1808    most recent
00362.2003v1
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (2)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Thein, E.
Right arrow Articles by Messmer, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Thein, E.
Right arrow Articles by Messmer, K.

Direct assessment and distribution of regional portal blood flow in the pig by means of fluorescent microspheres

E. Thein, M. Becker, H. Anetzberger, C. Hammer, and K. Messmer

Institute for Surgical Research, University of Munich, 81377 Munich, Germany

Submitted 10 April 2003 ; accepted in final form 13 June 2003

Measurement of regional organ blood flow by means of fluorescent microspheres (FM) is an accepted method. However, determination of regional portal blood flow (RPBF) cannot be performed by microspheres owing to the entrapment of the spheres in the upstream capillary bed of the splanchnic organs. We hypothesized that an adequate experimental setting would enable us to measure RPBF by means of FM and to analyze its distribution within the pig liver. A mixing chamber for the injection of FM was developed, and its capability to distribute FM homogeneously in the blood was evaluated in vitro. The chamber was implanted into the portal vein of six anesthetized pigs (23.5 ± 2.9 kg body wt). Three consecutive, simultaneous injections of FM of two different colors into the chamber were performed. Reference portal blood samples were collected by means of a Harvard pump. At the end of the experiment, the liver was explanted and fixed in formalin before dissection. FM were isolated from the tissue samples by an automated process, and fluorescence intensity was determined. Comparison of 5,458 single RPBF values, determined by simultaneously injected FM, revealed good agreement (bias 2.5%, precision 12.7%) and high correlation (r = 0.97, r2 = 0,95, slope = 1.04, intercept = 0.05). Median RPBF was 1.07 ± 0.78 ml · min-1 · g-1. Allocation of the blood flow values to the anatomic regions of the liver revealed a significantly higher RPBF (P = 0.01) in the liver tissue located close to the diaphragm compared with the rest of the organ and a significantly lower RPBF (P = 0.01) in the left liver lobe compared with the median and right lobes. The results show that the model presented makes it possible to measure RPBF by means of FM reliably and that RPBF is distributed heterogeneously in the porcine liver.

liver



Address for reprint requests and other correspondence: E. Thein, Institute for Surgical Research, Marchionini Str. 27, 81377 Munich, Germany (E-mail: ethein{at}icf.med.uni-muenchen.de).




This article has been cited by other articles:


Home page
Toxicol PatholHome page
D. E. Malarkey, K. Johnson, L. Ryan, G. Boorman, and R. R. Maronpot
New Insights into Functional Aspects of Liver Morphology
Toxicol Pathol, January 1, 2005; 33(1): 27 - 34.