Journal of Applied Physiology Ad Instruments
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 93: 1030-1038, 2002. First published May 10, 2002; doi:10.1152/japplphysiol.00110.2002
8750-7587/02 $5.00
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow All Versions of this Article:
93/3/1030    most recent
00110.2002v1
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kiyokawa, H.
Right arrow Articles by Pasterkamp, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kiyokawa, H.
Right arrow Articles by Pasterkamp, H.
Vol. 93, Issue 3, 1030-1038, September 2002

Volume-dependent variations of regional lung sound, amplitude, and phase

Hiroshi Kiyokawa and Hans Pasterkamp

Department of Pediatrics and Child Health, University of Manitoba, Winnipeg, Manitoba, Canada R3C 3J7

Acoustic imaging of the respiratory system demonstrates regional changes of lung sounds that correspond to pulmonary ventilation. We investigated volume-dependent variations of lung sound phase and amplitude between two closely spaced sensors in five adults. Lung sounds were recorded at the posterior right upper, right lower, and left lower lobes during targeted breathing (1.2 ± 0.2 l/s; volume = 20-50 and 50-80% of vital capacity) and passive sound transmission (<= 0.2 l/s; volumes as above). Average sound amplitudes were obtained after band-pass filtering to 75-150, 150-300, and 300-600 Hz. Cross correlation established the phase relation of sound between sensors. Volume-dependent variations in phase (<= 1.5 ms) and amplitude (<= 11 dB) were observed at the lower lobes in the 150- to 300-Hz band. During inspiration, increasing delay and amplitude of sound at the caudal relative to the cranial sensor were also observed during passive transmission in several subjects. This previously unrecognized behavior of lung sounds over short distances might reflect spatial variations of airways and diaphragms during breathing.

respiratory mechanics; acoustics; respiratory sounds; pulmonary ventilation; signal processing; computer assistance


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
P. J. Berger, E. M. Skuza, C. A. Ramsden, and M. H. Wilkinson
Velocity and attenuation of sound in the isolated fetal lung as it is expanded with air
J Appl Physiol, June 1, 2005; 98(6): 2235 - 2241.