Journal of Applied Physiology Information on EB 2010
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 104: 639-647, 2008. First published December 13, 2007; doi:10.1152/japplphysiol.00322.2007
8750-7587/08 $8.00
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow All Versions of this Article:
104/3/639    most recent
00322.2007v1
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (4)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Black, C. D.
Right arrow Articles by Dudley, G. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Black, C. D.
Right arrow Articles by Dudley, G. A.

High specific torque is related to lengthening contraction-induced skeletal muscle injury

Christopher D. Black,1 Christopher P. Elder,1 Ashraf Gorgey,2 and Gary A. Dudley{dagger}

1Department of Kinesiology, The University of Georgia, Athens, Georgia; and 2Department of Physical Medicine and Rehabilitation, University of Michigan, Ann Arbor, Michigan

Submitted 21 March 2007 ; accepted in final form 11 December 2007

Animal models implicate multiple mechanical factors in the initiation of exercise-induced muscle injury. Muscle injury has been widely studied in humans, but few data exist regarding the underlying cause of muscle injury. This study sought to examine the role of torque per active muscle volume in muscle injury. Eight subjects performed 80 electrically stimulated [via electromyostimulation (EMS)] eccentric contractions of the right and left quadriceps femoris (QF) through an 80° arc at 120°/s. Specific torque was varied by applying 25-Hz EMS to one thigh and 100-Hz EMS to the contralateral thigh. Transverse relaxation time (T2) magnetic resonance images of the QF were collected before and 3 days after the eccentric exercise bouts. Injury was assessed via changes in isometric force and ratings of soreness over the course of 14 days after exercise and by determining changes in T2 and muscle volume 3 days after exercise. The 100-Hz EMS induced greater force loss (P < 0. 05), soreness (P < 0.05), change in muscle volume (P = 0.03), and volume of muscle demonstrating increased T2 (P = 0.005) than the 25-Hz EMS. In addition, injury was found to be similar across the QF in all but the most proximal regions of the QF. Our findings suggest that, in humans, high torque per active volume during lengthening muscle contractions is related to muscle injury.

transverse relaxation time magnetic resonance images; electrical stimulation; muscle activation; soreness



Address for reprint requests and other correspondence: C. D. Black, Dept. of Kinesiology, The Univ. of Georgia, 330 River Rd. 30602-6554, Athens, GA (e-mail: blackcd{at}uga.edu)




This article has been cited by other articles:


Home page
Am J Sports MedHome page
J. W. Orchard, T. James, M. Portus, A. Kountouris, and R. Dennis
Fast Bowlers in Cricket Demonstrate Up to 3- to 4-Week Delay Between High Workloads and Increased Risk of Injury
Am. J. Sports Med., June 1, 2009; 37(6): 1186 - 1192.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online
Copyright © 2008 by the American Physiological Society.