Journal of Applied Physiology Ad Instruments
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 103: 883-894, 2007. First published June 14, 2007; doi:10.1152/japplphysiol.00292.2007
8750-7587/07 $8.00
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow All Versions of this Article:
103/3/883    most recent
00292.2007v1
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (2)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Prisk, G. K.
Right arrow Articles by Hopkins, S. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Prisk, G. K.
Right arrow Articles by Hopkins, S. R.

Pulmonary perfusion in the prone and supine postures in the normal human lung

G. Kim Prisk,1,2 Kei Yamada,3 A. Cortney Henderson,1 Tatsuya J. Arai,1 David L. Levin,2 Richard B. Buxton,2 and Susan R. Hopkins1,2

Departments of 1Medicine and 2Radiology, and 3School of Medicine, University of California, San Diego, La Jolla, California

Submitted 14 March 2007 ; accepted in final form 8 June 2007

Prone posture increases cardiac output and improves pulmonary gas exchange. We hypothesized that, in the supine posture, greater compression of dependent lung limits regional blood flow. To test this, MRI-based measures of regional lung density, MRI arterial spin labeling quantification of pulmonary perfusion, and density-normalized perfusion were made in six healthy subjects. Measurements were made in both the prone and supine posture at functional residual capacity. Data were acquired in three nonoverlapping 15-mm sagittal slices covering most of the right lung: central, middle, and lateral, which were further divided into vertical zones: anterior, intermediate, and posterior. The density of the entire lung was not different between prone and supine, but the increase in lung density in the anterior lung with prone posture was less than the decrease in the posterior lung (change: +0.07 g/cm3 anterior, –0.11 posterior; P < 0.0001), indicating greater compression of dependent lung in supine posture, principally in the central lung slice (P < 0.0001). Overall, density-normalized perfusion was significantly greater in prone posture (7.9 ± 3.6 ml·min–1·g–1 prone, 5.1 ± 1.8 supine, a 55% increase; P < 0.05) and showed the largest increase in the posterior lung as it became nondependent (change: +71% posterior, +58% intermediate, +31% anterior; P = 0.08), most marked in the central lung slice (P < 0.05). These data indicate that central posterior portions of the lung are more compressed in the supine posture, likely by the heart and adjacent structures, than are central anterior portions in the prone and that this limits regional perfusion in the supine posture.

prone; supine; magnetic resonance imaging; lung density; gas exchange; gravity



Address for reprint requests and other correspondence: G. Kim Prisk, Dept. of Medicine and Radiology, 0931, Univ. of California, San Diego, 9500 Gilman Dr., La Jolla, CA 92093-0931 (e-mail: kprisk{at}ucsd.edu)




This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
K. J. Burnham, T. J. Arai, D. J. Dubowitz, A. C. Henderson, S. Holverda, R. B. Buxton, G. K. Prisk, and S. R. Hopkins
Pulmonary perfusion heterogeneity is increased by sustained, heavy exercise in humans
J Appl Physiol, November 1, 2009; 107(5): 1559 - 1568.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
M. H. Tawhai, M. P. Nash, C.-L. Lin, and E. A. Hoffman
Supine and prone differences in regional lung density and pleural pressure gradients in the human lung with constant shape
J Appl Physiol, September 1, 2009; 107(3): 912 - 920.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
S. Verbanck, Y. Kerckx, D. Schuermans, C. de Bisschop, H. Guenard, R. Naeije, W. Vincken, and A. Van Muylem
The effect of posture-induced changes in peripheral nitric oxide uptake on exhaled nitric oxide
J Appl Physiol, May 1, 2009; 106(5): 1494 - 1498.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
T. J. Arai, A. C. Henderson, D. J. Dubowitz, D. L. Levin, P. J. Friedman, R. B. Buxton, G. K. Prisk, and S. R. Hopkins
Hypoxic pulmonary vasoconstriction does not contribute to pulmonary blood flow heterogeneity in normoxia in normal supine humans
J Appl Physiol, April 1, 2009; 106(4): 1057 - 1064.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
R. Glenny
Counterpoint: Gravity is not the major factor determining the distribution of blood flow in the healthy human lung
J Appl Physiol, May 1, 2008; 104(5): 1533 - 1535.
[Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
P. D. Wagner, W. W. Wagner Jr., S. R. Hopkins, G. K. Prisk, K. S. Burrowes, and M. H. Tawhai
Point:Counterpoint: Gravity is/is not the major factor determining the distribution of blood flow in the human lung.
J Appl Physiol, May 1, 2008; 104(5): 1537 - 1538.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online
Copyright © 2007 by the American Physiological Society.