Journal of Applied Physiology Ad Instruments
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 103: 587-593, 2007. First published May 24, 2007; doi:10.1152/japplphysiol.00199.2007
8750-7587/07 $8.00
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow All Versions of this Article:
103/2/587    most recent
00199.2007v1
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Zhang, W.
Right arrow Articles by Kassab, G. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Zhang, W.
Right arrow Articles by Kassab, G. S.

Flow-induced shear strain in intima of porcine coronary arteries

Wei Zhang,1 Yi Liu,1 and Ghassan S. Kassab1,2,3

Departments of 1Biomedical Engineering, 2Surgery, and 3Cellular and Integrative Physiology, Indiana University Purdue University Indianapolis, Indianapolis, Indianapolis

Submitted 17 February 2007 ; accepted in final form 15 May 2007

The in vivo circumferential strain has a small variation throughout the vascular system (aorta to arterioles). The axial strain has also been shown to be nearly the same as the circumferential strain under physiological loading. Since the endothelium is mechanically much softer than the media-adventitia in healthy arteries, the porcine intima was considered as a mechanically distinct layer from the media-adventitia in a two-layer computational model. Based on the simulation result, we hypothesize that the flow-induced shear strain in intima can be of similar value as the pressure-induced circumferential strain in healthy coronary arteries, even though the shear stress is orders of magnitude smaller than the circumferential stress. The nearly isotropic deformation (circumferential, axial, and shear strains) may have important implications for mechanical homeostasis of endothelial cells, mechanotransduction, growth, and remodeling of blood vessels.

endothelium; stress; deformation; mechanotransduction