Departments of 1Radiology and 2Biomedical Engineering, University of Iowa, Iowa City, Iowa; 3Department of Anesthesiology and Critical Care Medicine, The Johns Hopkins University, Baltimore, Maryland
Submitted 28 September 2005 ; accepted in final form 13 November 2006
Xenon computed tomography (Xe-CT) is used to estimate regional ventilation by measuring regional attenuation changes over multiple breaths while rebreathing a constant Xe concentration ([Xe]). Xe-CT has potential human applications, although anesthetic properties limit [Xe] to
35%. We investigate effects of lower [Xe], including a low [Xe]-krypton (Kr) combination, on time constant (TC) determination. Six anesthetized sheep were scanned prone and supine using multidetector row CT. Lungs were imaged by respiratory gating during washin of a 30%, 40%, 55% Xe, and a 30% Xe/30% Kr mixture. Using Kr avoids unwanted effects of Xe. Mean TCs, coefficients of variation (CV), and half confidence intervals (CI)/mean served as indexes of sensitivity to noise. Mean supine and prone TCs of three [Xe] values were not significantly different. Average CVs of TCs increased from 57% (55% Xe), 58% (40% Xe), and 73% (30% Xe) (P < 0.05: paired t-tests; 30% Xe vs. higher [Xe]). Monte Carlo simulation indicated a CV based on inherent image noise was 8% for 55% Xe and 17% for 30% Xe (P < 0.05). Adding 30% Kr to 30% Xe gave a washin signal equivalent to 40% Xe. Half CI/mean using the 30% Xe/30% Kr mixture was not significantly different from 55 and 40% Xe. Although average TCs were not affected by changes in [Xe], the higher CV and half CI/mean suggested reduced signal-to-noise ratio at the 30% [Xe]. The 30% Xe/30% Kr mixture was comparable to that of 40% Xe, providing an important agent for CT-based assessment of regional ventilation in humans.
washin; regional ventilation measurements; computed tomography; pulmonary imaging; multidetector computed tomography; Monte Carlo simulation; regional lung function
This article has been cited by other articles:
![]() |
S. Bayat, L. Porra, H. Suhonen, P. Suortti, and A. R. A. Sovijarvi Paradoxical conducting airway responses and heterogeneous regional ventilation after histamine inhalation in rabbit studied by synchrotron radiation CT J Appl Physiol, June 1, 2009; 106(6): 1949 - 1958. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. I. Rennard and T. Higenbottam Exacerbation-Free COPD: A Goal Too Far? Proceedings of the ATS, December 1, 2007; 4(8): 583 - 585. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| Visit Other APS Journals Online |