Journal of Applied Physiology Add DOIs to your references at manuscript stage!
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 101: 707-714, 2006. First published May 11, 2006; doi:10.1152/japplphysiol.00154.2006
8750-7587/06 $8.00
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow All Versions of this Article:
101/3/707    most recent
00154.2006v1
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (6)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Berger, N. J. A.
Right arrow Articles by Jones, A. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Berger, N. J. A.
Right arrow Articles by Jones, A. M.

Influence of acute plasma volume expansion on VO2 kinetics, VO2peak, and performance during high-intensity cycle exercise

Nicolas J. A. Berger,1 Iain T. Campbell,2 Daryl P. Wilkerson,1 and Andrew M. Jones1

1Department of Exercise and Sport Science, Manchester Metropolitan University, Alsager; and 2Department of Anaesthesia, Wythenshawe Hospital, Manchester, United Kingdom

Submitted 7 February 2006 ; accepted in final form 9 May 2006

The purpose of this study was to examine the influence of acute plasma volume expansion (APVE) on oxygen uptake (VO2) kinetics, VO2peak, and time to exhaustion during severe-intensity exercise. Eight recreationally active men performed "step" cycle ergometer exercise tests at a work rate requiring 70% of the difference between the gas-exchange threshold and VO2max on three occasions: twice as a "control" (Con) and once after intravenous infusion of a plasma volume expander (Gelofusine; 7 ml/kg body mass). Pulmonary gas exchange was measured breath by breath. APVE resulted in a significant reduction in hemoglobin concentration (preinfusion: 16.0 ± 1.0 vs. postinfusion: 14.7 ± 0.8 g/dl; P < 0.001) and hematocrit (preinfusion: 44 ± 2 vs. postinfusion: 41 ± 3%; P < 0.01). Despite this reduction in arterial O2 content, APVE had no effect on VO2 kinetics (phase II time constant, Con: 33 ± 15 vs. APVE: 34 ± 12 s; P = 0.74), and actually resulted in an increased VO2peak (Con: 3.90 ± 0.56 vs. APVE: 4.12 ± 0.55 l/min; P = 0.006) and time to exhaustion (Con: 365 ± 58 vs. APVE: 424 ± 64 s; P = 0.04). The maximum O2 pulse was also enhanced by the treatment (Con: 21.3 ± 3.4 vs. APVE: 22.7 ± 3.4 ml/beat; P = 0.04). In conclusion, APVE does not alter VO2 kinetics but enhances VO2peak and exercise tolerance during high-intensity cycle exercise in young recreationally active subjects.

blood volume; endurance; O2 kinetics; performance



Address for reprint requests and other correspondence: A. M. Jones, School of Sport and Health Sciences, Univ. of Exeter, St. Luke’s Campus, Heavitree Rd., Exeter, EX1 2LU, UK (e-mail: a.m.jones{at}exeter.ac.uk)




This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
S. T. Sims, N. J. Rehrer, M. L. Bell, and J. D. Cotter
Preexercise sodium loading aids fluid balance and endurance for women exercising in the heat
J Appl Physiol, August 1, 2007; 103(2): 534 - 541.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
G. S. Zavorsky
Plasma volume expansion does not influence oxygen uptake kinetics in trained cyclists
J Appl Physiol, February 1, 2007; 102(2): 828 - 828.
[Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
A. M. Jones, N. J. Berger, D. P. Wilkerson, and I. T. Campbell
Reply to Zavorsky
J Appl Physiol, February 1, 2007; 102(2): 829 - 829.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online
Copyright © 2006 by the American Physiological Society.