Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


J Appl Physiol (October 25, 2007). doi:10.1152/japplphysiol.00893.2007
This Article
Right arrow Full Text (PDF) Free
Right arrow All Versions of this Article:
104/1/262    most recent
00893.2007v1
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Daubenspeck, J. A.
Right arrow Articles by Nattie, E. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Daubenspeck, J. A.
Right arrow Articles by Nattie, E. E.
Submitted on August 20, 2007
Accepted on October 24, 2007

Acoustic plethysmography measures breathing in unrestrained neonatal mice

J. Andrew Daubenspeck1*, Aihua Li1, and Eugene E. Nattie2

1 Physiology Department, Dartmouth Medical School, Lebanon, New Hampshire, United States
2 Physiology Department, Dartmouth Medical School, Lebanon, New Hampshire, United States; Dept Physiol Dartmouth Med Sch, Lebanon (USA), Lebanon, New Hampshire, United States; , United States

* To whom correspondence should be addressed. E-mail: andrew.daubenspeck{at}dartmouth.edu.

Measurement of breathing volumes in neonatal mice is of growing importance in order to characterize the influence of development and genetic modifications upon respiratory control in order to evaluate hypotheses concerned with human infant deficits that may affect Sudden Infant Death Syndrome (SIDS) for example. Current techniques require undesirable physical constraints or incur possible artifacts specific to very small animals. We have examined the utility of a recently proposed approach using an acoustic resonance procedure that does not require undue physical constraint beyond placement in the acoustic plethysmograph. We show here that this approach can be applied to baby mice five days after birth and that it can be accurately calibrated. In addition, this approach should be useful to study unrestrained neonatal mice under conditions where body temperature approaches environmental temperature and barometric plethysmography cannot be used.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
Visit Other APS Journals Online
Copyright © 1948 by the American Physiological Society.