Journal of Applied Physiology Journal of Neurophysiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


J Appl Physiol (August 23, 2002). doi:10.1152/japplphysiol.00544.2002
This Article
Right arrow Full Text (PDF) Free
Right arrow All Versions of this Article:
93/6/1939    most recent
00544.2002v1
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by LaDisa, J. F
Right arrow Articles by Pagel, P. S
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by LaDisa, J. F
Right arrow Articles by Pagel, P. S

Articles in PresS, published online ahead of print August 23, 2002
J Appl Physiol, 10.1152/jap.00544.2002
Submitted on June 21, 2002
Accepted on August 20, 2002

STENT IMPLANTATION ALTERS CORONARY ARTERY HEMODYNAMICS AND WALL SHEAR STRESS DURING MAXIMAL VASODILATION

John F LaDisa1, Douglas A Hettrick1, Lars E Olson2, Ismail Guler3, Eric R Gross4, Tobias T Kress4, Judy R Kersten5, David C Warltier6, and Paul S Pagel6*

1 Department of Anesthesiology, Medical College of Wisconsin, Milwaukee, Wisconsin, USA; Biomedical Engineering, Marquette University, Milwaukee, Wisconsin, USA
2 Biomedical Engineering, Marquette University, Milwaukee, Wisconsin, USA
3 Boston Scientific - Scimed, Maple Grove, Minnesota, USA
4 Department of Anesthesiology, Medical College of Wisconsin, Milwaukee, Wisconsin, USA
5 Department of Anesthesiology, Medical College of Wisconsin, Milwaukee, Wisconsin, USA; Pharmacology and Toxicology, Medical College of Wisconsin, Milwaukee, Wisconsin, USA
6 Department of Anesthesiology, Medical College of Wisconsin, Milwaukee, Wisconsin, USA; Pharmacology and Toxicology, Medical College of Wisconsin, Milwaukee, Wisconsin, USA; Biomedical Engineering, Marquette University, Milwaukee, Wisconsin, USA

* To whom correspondence should be addressed. E-mail: pspagel{at}mcw.edu.

Coronary stents improve resting blood flow and flow reserve in the presence of stenoses, but the impact of these devices on fluid dynamics during profound vasodilation is largely unknown. We tested the hypothesis that stent implantation affects adenosine-induced alterations in coronary hemodynamics and wall shear stress in anesthetized dogs (n=6) instrumented for measurement of left anterior descending coronary artery (LAD) blood flow, velocity, diameter, and radius of curvature. Indices of fluid dynamics and shear stress were determined before and after placement of a slotted-tube stent in the absence and presence of an adenosine infusion (1.0 mg/min). Adenosine increased blood flow, Reynolds and Dean numbers (Re and De, respectively), and regional and oscillatory shear stress ({tau} and {tau}os, respectively) concomitant with reductions in LAD vascular resistance and segmental compliance before stent implantation. Increases in LAD blood flow, Re, De, and indices of shear stress were observed after stent deployment (P<0.05). Stent implantation reduced LAD segmental compliance to zero and potentiated increases in segmental and coronary vascular resistance during adenosine. Adenosine-induced increases in coronary blood flow and reserve, Re, De, {tau}, and {tau}os were attenuated after the stent was implanted. The results indicate that stent implantation blunts alterations in fluid dynamics during coronary vasodilation in vivo.




This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
J. F. LaDisa Jr., Lars. E. Olson, R. C. Molthen, D. A. Hettrick, P. F. Pratt, M. D. Hardel, J. R. Kersten, D. C. Warltier, and P. S. Pagel
Alterations in wall shear stress predict sites of neointimal hyperplasia after stent implantation in rabbit iliac arteries
Am J Physiol Heart Circ Physiol, May 1, 2005; 288(5): H2465 - H2475.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
J. F. LaDisa Jr., L. E. Olson, I. Guler, D. A. Hettrick, J. R. Kersten, D. C. Warltier, and P. S. Pagel
Circumferential vascular deformation after stent implantation alters wall shear stress evaluated with time-dependent 3D computational fluid dynamics models
J Appl Physiol, March 1, 2005; 98(3): 947 - 957.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
J. F. LaDisa Jr., L. E. Olson, I. Guler, D. A. Hettrick, S. H. Audi, J. R. Kersten, D. C. Warltier, and P. S. Pagel
Stent design properties and deployment ratio influence indexes of wall shear stress: a three-dimensional computational fluid dynamics investigation within a normal artery
J Appl Physiol, July 1, 2004; 97(1): 424 - 430.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
E. R. Gross, J. F. LaDisa Jr., D. Weihrauch, L. E. Olson, T. T. Kress, D. A. Hettrick, P. S. Pagel, D. C. Warltier, and J. R. Kersten
Reactive oxygen species modulate coronary wall shear stress and endothelial function during hyperglycemia
Am J Physiol Heart Circ Physiol, May 1, 2003; 284(5): H1552 - H1559.
[Abstract] [Full Text] [PDF]