1 Imaging Research Laboratories, Robarts Research Institute, London, Canada
2 Imaging Research Laboratories, Robarts Research Institute, London, Canada; Department of Medical Biophysics, University of Western Ontario, London, Canada; Department of Diagnostic Radiology, University of Western Ontario, London, Canada
3 Imaging Research Laboratories, Robarts Research Institute, London, Canada; Department of Medical Biophysics, University of Western Ontario, London, Canada
4 Division of Respirology, London Health Sciences Centre, London, Canada
* To whom correspondence should be addressed. E-mail: gsantyr{at}imaging.robarts.ca.
We measured ventilation (Vdot) in seven anesthetized, mechanically ventilated, supine Wistar rats. Images of the whole lung were continuously acquired using a dynamic flat-panel volumetric micro-computed tomography (micro-CT) scanner used for pre-clinical drug development in small animals during ventilation with a xenon-oxygen (Xe/O2) gas mixture. Forty volumes consisting of eighty 0.45-mm-thick slices (covering the entire lung) were acquired in 40 s, using a gantry rotation rate of one rotation per second. The animals were ventilated at a respiratory rate of 60 breaths/min, matching the gantry rotation rate, and imaged without suspending ventilation. A previously published model was modified slightly and used to calculate the whole-lung ventilation from volumes of interest generated by seeded region growing. Linear regression of calculated whole-lung ventilation volumes vs. expected tidal volumes yielded a slope of 1.12 ± 0.11 (slope ± SE) and a y-intercept of —1.56 ± 0.42 mL (y-intercept ± SE) with 95% confidence intervals of 0.83 to 1.40 and —2.6 to —0.5 mL, respectively. The same model was used to calculate the regional ventilation in axial slices for each animal. Voxels were fit to the model to yield a map of Vdot, which displayed an anterior/posterior gravitational gradient of (—3.9 ± 1.8) x 10—6 mL·s—1·cm—1 for slices immediately superior to the diaphragm and (—6.0 ± 2.4) x 10—6 mL·s—1·cm—1 for slices at the mid-level of the heart (mean ± SD). Thus, continuous Xe-enhanced computed tomography enables the noninvasive determination of regional Vdot with the spatial resolution necessary for rats.
This article has been cited by other articles:
![]() |
B. Driehuys, H. E. Moller, Z. I. Cleveland, J. Pollaro, and L. W. Hedlund Pulmonary Perfusion and Xenon Gas Exchange in Rats: MR Imaging with Intravenous Injection of Hyperpolarized 129Xe Radiology, August 1, 2009; 252(2): 386 - 393. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH |