|
|
||||||||
1Institute of Physiology and 2Department of Radiology and Diagnostics, Medical Faculty, and 3Institute of Textile and Clothing Technology, Faculty of Mechanical Engineering, Technical University Dresden, Dresden, Germany
Submitted 2 September 2004 ; accepted in final form 1 August 2005
| ABSTRACT |
|---|
|
|
|---|
flow autoregulation; transmural pressure; arterial inflow; venous occlusion plethysmography
To assess the influence of external compression on local blood flow, we tested the hypothesis that external compression increases forearm blood flow. The hypothesis is based on the following causal chain: external compression pressure increases tissue pressure, which decreases transmural vascular pressure. This decreased transmural pressure may trigger a myogenic response, resulting in vessel relaxation. If this response comprises the segments of small arteries and arterioles, flow might increase. Thus we applied compression sleeves to the forearms of healthy volunteers and measured the forearm blood flow and the compression pressure simultaneously. The duration of the response was also studied. The flow measurements generally obtained via occlusion plethysmography were complemented by MR measurements. Both methods show that external compression equivalent to a skin surface pressure of 1323 mmHg doubles forearm blood flow.
| METHODS |
|---|
|
|
|---|
The effect of compressive pressure on forearm blood flow was tested in a group of nine healthy young men (25 ± 3 yr of age). The study was approved by the ethical committee of the Medical Faculty of the Technical University of Dresden. No subject had diabetes or a history of venous or arterial disease, nor was any subject taking vasoactive medication. Upper arm blood pressures measured with standard blood pressure cuffs verified that subjects were normotensive (117 ± 7 and 76 ± 5 mmHg systolic and diastolic, respectively). Heart rate was 68 ± 8 beats/min. During the experimental sessions, the subjects were seated in an armchair, such that the forearms rested comfortably on wide armrests at heart level, with the wrist slightly elevated above the elbow to promote venous drainage. During the entire session, a light cloth over both forearms prevented cooling. The room temperature was regulated and held constant at 22 ± 2°C.
Study 1. The purpose of study 1 (n = 9) was to determine the forearm blood flow with six compression sleeves exerting an increasing compression pressure. The blood flow of both forearms was measured under baseline conditions. Then the compression sleeve was applied to the right forearm (in general, the dominant arm) for 10 min. At the end of this intervention period (within 10 min), the blood flow of both arms was measured. In the same manner, five other sleeves with increasing compression pressure were applied consecutively to the right forearm. Thus the duration of the entire compression protocol was 60 min. Again, after removal of the strongest compression sleeve, the blood flow of both arms was measured twice under baseline conditions: 1) immediately after removal of the last compression sleeve and 2) after an additional 10 min.
Study 2. The purpose of study 2 (n = 9) was to determine the effect of an external compression pressure on the arterial flow reserve. Study 1 was repeated, with the addition of arterial flow reserve measurements 1) after the second baseline measurement, before application of the first compression sleeve; 2) after application of the third compression sleeve (CS3); and 3) at the end of the study, i.e., after the second baseline measurement. After the end of the arterial flow reserve measurement, there was a resting interval of 10 min before the next measurement or before application of compression pressure.
Study 3. The purpose of study 3 (n = 5) was to test the duration of the effect of compression on forearm blood flow. After a baseline measurement, compression sleeve CS3 was applied to the test arm, and flow measurements were obtained at 10 min, 30 min, and then every 30 min to 180 min. After 180 min, the compression sleeve was removed, and forearm blood flow was determined immediately and after 10 and 30 min. Between flow measurements, that is, from 30 to 180 min, the subjects could move freely and perform laboratory work.
Study 4.
The purpose of study 4 (n = 5) was to test the hypothesis that the flow augmentation by compressive force was maintained during light exercise or movement. After a baseline measurement, compression sleeve CS3 was applied to the test arm. A first measurement of resting flow was obtained after 10 min. Then the subjects were instructed to carry out rhythmic hand-grip exercise with both hands (510% of maximal voluntary contraction in a 1:2-s contraction-relaxation duty cycle) for
70 min. The low workload of 510% maximal voluntary contraction and the relaxation period twice as long as the contraction period were selected to prevent an increase in blood flow by the exercise itself. During handgrip exercise, blood flow was determined every 10 min. During the flow measurements (90 s), the subjects did not exercise.
Study 5.
The purpose of study 5 (n = 3) was to test the flow augmentation under clinical conditions and to measure the forearm blood flow with the MR technique. With use of the MR technique, the blood flow of the right forearm was determined under normal conditions without compression and again 10 min after the application of compression sleeve. For comparison, the blood flow of the same forearm was measured with venous occlusion plethysmography with and without the compression sleeve. For technical reasons, it was not possible to perform MR and plethysmography simultaneously. The time lag between the measurements was
180 min.
The temperature of both forearms was controlled using a multichannel measuring system (ALMEMO-1, Ahlborn Mess- und Regelungstechnik, Holzkirchen, Germany).
Flow Assessment
The arterial inflow and arterial flow reserve of both forearms were measured with venous occlusion plethysmography (COMPACTUS, Gutmann-Medizintechnik, Eurasburg, Germany). This method, which is based on measurement of volume changes when venous outflow is blocked, measures arterial inflow. The strain gauge was placed on the forearm where the circumference is maximal, and during application of the compression sleeve, the strain gauge was placed over the sleeve. The venous occlusion cuff around the upper arm was inflated for 6 s with a pressure of 60 mmHg to ensure venous occlusion. During this time, the arterial inflow was calculated from the increase of forearm circumference. The arterial inflow was measured six times consecutively every 15 s and averaged. The duration of the flow measurement was typically 90 s. The maximal arterial inflow or arterial flow reserve of the forearm was determined as the peak arterial inflow after 5 min of arterial occlusion. During the arterial occlusion, the cuff around the upper arm was inflated to 180 mmHg, which was
50 mmHg above the mean systolic pressure of the subjects.
External Pressure Measurement
The actual pressure under the sleeve was measured with a sensor using the piezoelectric effect (model MCDM-1, MIPM, Mammendorf, Germany). A piezoelectric crystal is characterized by the property under the application of a given pressure to induce a certain voltage. Such a sensor is suitable for measurement of pressure in biological tissue or between different layers. The MCDM-1 is a device especially developed to measure pressure under a compression stocking. The technical details of the device (14) and its application for measurement of the pressure exerted by the compression stocking (11) have been reported by others. The measurement error in our experiments was ±2 mmHg. The pressure under the stocking was measured at two positions with different winding radii of the circumference of the forearm. According to the law of Laplace, the pressure inside a wall is inversely proportional to the winding radius at a given wall tension. Therefore, the two sensors were placed on the forearm at positions of greatest and least winding radii.
Compression Sleeves
The force exerted on the skin surface critically depends on the dimensions and elastance of the sleeves as well as individual arm geometries. Thus the compression sleeves were manufactured individually for each volunteer on the basis of six measurements of the circumference of the forearm between wrist and elbow. The increasing level of compression was realized by decreasing the equivalent circumferences of the textile. In this way, the wall tension of the sleeves, when they covered the forearm, was increased according to the stress-strain relation. According to the law of Laplace, this increased wall tension exerted a certain pressure on the tissue of the forearm. Thus, for each subject, a set of six sleeves (CS1CS6) with decreasing circumferences was designed and manufactured using a knitted fabric that is based on an elastane yarn plated on a cotton yarn. These compression sleeves are similar to the sleeve of a sport tricot, and their thickness is 1.022 ± 0.034 mm. The stress-strain relation of the knitted fabrics was determined, and the textile parameters are summarized in Table 1.
|
MR Measurements
MR measurements were performed on a 1.5-T whole body scanner (Magnetom Sonata, Siemens, Erlangen, Germany). The volunteers were positioned in a supine-to-lateral position to locate the forearm near the isocenter of the magnet. A rectangular flexible surface coil was placed on the proximal end of the forearm. An electrocardiogram-triggered FLASH two-dimensional sequence with flow encoding perpendicular to the slice plane (maximum velocity = 100 cm/s) was applied (field of view = 220 * 165 mm2, matrix = 256 * 192, slice thickness = 5 mm, echo time = 3.9 ms, repetition time triggered to every heartbeat, 5 averages), giving modulus and velocity images every 32 ms. For quantification, the ARGUS software package was used (Siemens). Flow and velocity data were derived from regions that were fitted to the actual vessel size and position for each time point.
Statistics
Sample size was estimated a priori for the primary hypothesis that external compression would result in a vasodilatory response. These calculations showed that a sample size of nine subjects would allow detection of a 50% increase in forearm blood flow under external compression with a power of 80% at
= 0.05. Statistical comparisons were performed by Student's t-test and ANOVA for repeated measures. Forearm blood flow responses of the test arm to external pressure were compared with the response of the control arm. All calculated probability values were two tailed, and P < 0.05 was considered to indicate statistical significance. All group data are means ± SD.
| RESULTS |
|---|
|
|
|---|
|
The effect of increasing compressive force on forearm perfusion is shown in Fig. 2. All six compression sleeves enhanced blood flow of the test arm. The flow increases were significant (P < 0.001) compared with the control arm for CS2, CS3, CS4, CS5, and CS6. The flow increases were completely reversible after 1 min of removal of the compressive force.
|
50 mmHg by slight movement of the sleeve upward. Pressures >50 mmHg reduced forearm blood flow considerably.
|
|
Similar to baseline blood flow, the flow reserve was enhanced during application of compressive force. Peak flow after 5 min of occlusion was nearly five times baseline blood flow (Fig. 5). During application of compression sleeve CS3, peak flow was significantly (P < 0.01) increased to 28.0 ± 6.0 ml·min1·100 ml tissue1 compared with 17.4 ± 6.0 ml·min1·100 ml tissue1 without compression. These effects were completely reversed after removal of the compression sleeve. In contrast, baseline flow and flow reserve of the control arm remained unchanged over the entire duration of the experiment (Fig. 5B).
|
The effects of compression force on forearm blood flow were also studied for a more extended period of time (Fig. 6). In five subjects, forearm blood flow remained increased over the entire period of pressure application (3 h). After a slightly higher initial increase of blood flow, the flow response reached a steady state after 60 min. After removal of the compression sleeves, the flow changes were largely reversible after 1 min and fully reversible after 30 min. The forearm blood flow of the control arm remained unchanged during the entire study period.
|
In a further set of experiments, we tested whether the flow augmentation by compressive force was maintained during light exercise. Light hand exercise during continuous application of compression sleeves (CS3) was associated with a trend to a further slight elevation of forearm blood flow in the test arm, but not in the control arm (Fig. 7).
|
In a final set of experiments, forearm blood flow in response to compressive force (CS3) was determined consecutively by venous occlusion plethysmography and MR in three subjects. Both methods revealed increases of blood flow during the application of compression pressure (Fig. 8).
|
| DISCUSSION |
|---|
|
|
|---|
20 mmHg. The present study extends previous reports in which it was suggested that external compression may not only augment venous return but also affect arterial flow regulation separately. 2) The external compression significantly increases hyperemic peak flow after 5 min of circulatory arrest.
A few previous studies addressed the effects of moderate leg compression on arterial inflow (18, 22, 23, 25). In one of these studies, application of graded compression pressure did not change calf muscle blood flow (18); in this study, muscle blood flow was determined by measuring xenon-133 clearance, and the maximally applied compression pressure was 30 mmHg. In another study (25) conducted on male distance runners, moderate compression (40 mmHg) reduced the muscle blood flow in the thigh by
50%. The reason for the discrepancy between these two studies (18, 25) is not readily apparent, because the method used to assess changes in leg blood flow was identical. Another previous study comprising 14 healthy subjects reported the effects of leg compression by bandaging on leg pulsatile blood flow using a nuclear MR flowmeter (18, 19). A flow increase of 29% was reported for a pressure increase of
40 mmHg. Leg compression was produced by wrapping one leg from forefoot to knee with a four-layer bandaging system. The effect of lower compression pressures was not studied.
In the present study, an individually fitted set of compression sleeves was used to obtain flow measurements over a wider pressure range. To the best of our knowledge, this is the first systematic study performed on the human forearm. The use of elastic sleeves to induce an external compression pressure has two advantages. 1) Blood flow at the forearm can be measured with strain gauge plethysmography with and without the elastic sleeves. The strain gauge must be placed around the outside of the sleeve to detect the expansion of the forearm when the venous outflow is blocked. 2) With use of compression sleeves, it is possible to change or superimpose other conditions, such as hand exercise or free movement. To address the limitation of strain gauge utilization during application of a compression sleeve, the volume expansion during a single measuring cycle under resting conditions is estimated: if the resting blood flow to the forearm is 3 ml·min1·100 ml tissue1, then the additional blood volume that is pooled in the forearm during the short venous occlusion amounts to 0.3 ml/100 ml tissue. In other words, the additional volume is in the range of 0.3% of the unaffected volume. By design, the compression sleeves are stretched by 20% when applied to the forearm to produce the compression pressure. The additional stretch in the range of 0.3% is sufficiently small and can therefore be neglected. Under the increased flow conditions, when the compressive sleeve is applied to the forearm, the additional volume is in the range of 0.6% of the unaffected volume. This volume change is also sufficiently small that this effect can be neglected.
The elastic sleeve covers the forearm from elbow to wrist, and it is generally assumed that the pressure exerted at the surface of the forearm is transmitted into the depth of the tissue to the arterial vessels, as under every pneumatic cuff. In a methodological study, the transmission of a negative surface pressure (250 mmHg) into an 8-cm-long segment of arm was demonstrated (21). The forearm model was chosen, because it is well established for studies on blood flow in humans. Furthermore, the human forearm is not subject to hydrostatic pressure differences to the same degree as the human leg. It is unknown whether systematic differences exist between the upper and lower extremities with respect to the pressure range that enhances blood flow or to the mechanisms that might be involved. However, the results obtained in the present study and the majority of the previous studies conducted on the human leg indicate that external pressure application may increase blood flow in a similar pressure range and to a similar extent. The reason for the discrepancies between previous leg studies is not readily apparent. However, the study in which a decrease of leg flow was reported in response to external pressure was performed in athletes. Whether there are systematic differences of flow control between athletes and nonathletes that may explain differences of flow adjustment in response to external compression remains to be clarified.
The relation between compression pressure and flow increase was more consistent for the pressure measured under the sleeve for the larger winding radius (Fig. 3). The larger winding radius was determined over the group of hand flexors, whereas the minimal winding radius was measured over the region of the hand extensors. Both muscle groups differ considerably with respect to their masses. The mass of the group of flexors is considerably greater than that of the extensors. In addition, both muscle groups are compartmentalized and separated from each other by bone and ligament structures. Thus it seems that the true relation between compressive surface pressure and blood flow change of the forearm is best expressed by that determined for the larger winding radius. Additionally, scan of the human forearm shows that most of the cross-sectional area is characterized by a large winding radius. This relation between compressive pressure and blood flow change was almost linear for 020 mmHg.
The application of external pressure also increases the peak flow after a 5-min occlusion of the upper arm (Fig. 5). The increase in peak flow is greater than the increase in resting blood flow. In addition to resting blood flow, the present study evaluated flow under stimulated conditions induced by moderate handgrip exercise for 1 h (Fig. 6) or for 3 h, during which the subjects could move freely in the laboratory (Fig. 7). For both conditions, the enhancement of blood flow could be assessed, suggesting that the mechanism that leads to the flow augmentation is robust with respect to the particular condition.
The somewhat surprising finding that static compression consistently increases, rather than decreases, blood flow of the human forearm gives rise to the question of the underlying mechanism(s). On the basis of known vascular control features, three mechanisms may envisioned to account for this: 1) myogenic response, 2) venular-arteriolar communication, and 3) skin vasomotor reflexes.
Myogenic Response
It is well established that arteriolar vessels constrict in response to an increase of the vessel transmural pressure gradient and dilate in response to a fall of the pressure gradient (Bayliss effect) (2, 6, 12). The increased external arm compression by the sleeve is transmitted into the tissue and reduces the transmural pressure gradient of the arterial vessels and arterioles in the forearm (21). The potential importance of transmural vascular pressure is supported by the early study of Greenfield and Patterson (8), who applied subatmospheric pressure (100 mmHg) to the forearm for up to 1 min. Immediately after pressure release, venous occlusion plethysmography indicated a decrease of blood flow, which may have reflected a vasoconstriction in response to the increase of the vessel transmural pressure during external application of the subatmospheric pressure.
In a more detailed study, Lott et al. (20) applied a positive or negative pressure of 50 mmHg to the forearm with an onset time and a reset time of <0.2 s. During the first two heartbeats after the onset of +50-mmHg pressure, a rapid transient decrease of blood flow was followed by a steady increase of flow. This steady increase of flow after a positive-pressure step and the equivalent decrease of flow after a negative-pressure step provide evidence that the myogenic response is normally operative in the forearm circulation of humans.
Our study clearly demonstrates that external pressure increases not only resting blood flow in the forearm but also the peak flow after a 5-min occlusion. The role of nitric oxide (NO)-mediated dilatation in the hyperemic flow response was investigated in two studies (4, 11) and revealed that hyperemic peak flow was not influenced by NO synthase blockade. Joannides et al. (11) measured blood flow and diameter of the radial artery, and the occlusion cuff was placed distally, around the wrist. Under conditions of NO synthase inhibition with N-monomethyl-L-arginine (L-NMMA), the blood flow increase was unchanged compared with control conditions, but the diameter of the radial artery was reduced. Doshi et al. (4) imaged the brachial artery for diameter measurements 710 cm distal to the puncture site for L-NMMA infusion, and the hyperemic response was provoked with occlusion cuffs at two positions: distal to the ultrasound probe for imaging and proximal to the puncture site. When NO production was blocked with L-NMMA, there was no dilatation of the brachial artery with the occlusion cuff around the wrist; with the occlusion cuff around the upper arm, however, initial dilatation of the brachial artery was the same as under control conditions. These two studies demonstrated that the decreasing the transmural pressure alone, as during 35 min of circulatory arrest, produces a local dilatation. This dilatation does not require local NO production. In this study, we have demonstrated that external compression increases not only resting blood flow in the forearm but also the hyperemic peak flow. These two facts point to the key role of the transmural pressure and the myogenic response in the underlying processes.
Venular-Arteriolar Communication
Because of the much thicker wall, arterial vessels are considerably more rigid than venous vessels. External pressure application may therefore reduce the venous vessel lumen considerably, whereas the arterial segments dilate, because of the above-mentioned myogenic response. As a consequence of the reduced lumen, blood flow may exert an enhanced shear stress in venous vessel segments, which may trigger the release of endothelial dilators in the venous segments. Besides acting locally and, thereby, tending to normalize venous segment resistance in the microcirculation, these compounds (e.g., NO or endothelium-derived hyperpolarizing factors) may reach neighboring arterial vessel segments by diffusion and reduce arteriolar resistance (10). In the arteriolar vessel segments, this communication might act synergistically with the myogenic response in reducing vessel resistance. Within our experimental setup, we cannot exclude the influence of the venular-arteriolar communication under resting conditions. However, as pointed out above, L-NMMA treatment did not diminish the reactive hyperemic response after transient ischemia, which argues against the importance of this mechanism.
Skin Vasomotor Reflexes
The application of pressure to the skin surface may activate nonnociceptive skin receptors or proprioceptors in the underlying tissue layers. The potential importance of such reflexes has been stressed recently (1, 7). After application of increasing (5 mmHg/min) external pressure locally (1 cm2), microcirculatory flow in the same region was measured by laser-Doppler flowmeter. In the range of high compression pressure (>50 mmHg), the laser-Doppler flow signal decreased steadily, whereas at 20 mmHg there was a transient increase in the laser-Doppler flow signal above baseline. However, this result might also be evoked by a myogenic response. More study is required to conclusively discern between these two causal factors.
In conclusion, the present study demonstrates that systematic elevation of forearm external compression results in an increase of resting blood flow and hyperemic peak flow in that region. The maximal flow effect is induced by a pressure increase of 20 mmHg. The flow increase in response to external pressure application is likely mediated by the myogenic response. Future studies are needed to define the limits of the involvement of venous-arterial communication and skin vasomotor reflexes.
| GRANTS |
|---|
|
|
|---|
| FOOTNOTES |
|---|
The costs of publication of this article were defrayed in part by the payment of page charges. The article must therefore be hereby marked "advertisement" in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.
| REFERENCES |
|---|
|
|
|---|
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| Visit Other APS Journals Online |