|
|
||||||||
INNOVATIVE METHODOLOGY
Section of Environmental Physiology, Department of Physiology and Pharmacology, Karolinska Institutet, SE-171 77 Stockholm, Sweden
Submitted 17 June 2003 ; accepted in final form 10 December 2003
| ABSTRACT |
|---|
|
|
|---|
cardiogenic oscillations; closing volume; single-breath washout; stroke volume
For the first experimental application of the novel technique, we studied sitting subjects, because for sitting normal humans, a relatively large amount of previously reported data could be used for comparison. Generally, previous studies have used separate methods and separate experimental sessions for assessments of the distributions of ventilation and perfusion in the lungs. We now present data obtained with a method where such assessments could be made rapidly and simultaneously. Being noninvasive, it permitted multiple repetitions at several gravity levels. We used a combined rebreathing and single-breath washout (SBW) maneuver to study sitting healthy humans in up to three times normal gravity (3 G).
We hypothesized that indexes of large-scale or apex-to-base ventilation and perfusion distributions would not necessarily show a proportional deterioration with increasing gravity, because lung tissue can be subject to only a finite degree of deformation and because there is a finite amount of blood in the pulmonary vasculature that can be redistributed. We further wanted to confirm in sustained hypergravity that not only large-scale, but also small-scale, distributions (on an acinar level) of ventilation and perfusion would become less homogeneous with increasing gravitational force. This is because, with hypergravity and increasing hydrostatic pressure gradient per unit vertical distance, alveolar expansion and perfusion will be expected to differ also within relatively small regions.
| MATERIALS AND METHODS |
|---|
|
|
|---|
Seven men and two women were studied. Their ages, heights, and body masses were as follows: 22-32 yr, 169-193 cm, and 64-90 kg. They had no history of cardiopulmonary disease and were not taking medication at the time of the study. They were also instructed not to drink coffee or use nicotine-containing products on the day of the experiment.
Ethics
The subjects received written information about the procedure, and informed consent was obtained. The experimental protocol used in the present study had been approved by the Ethics Committee of Karolinska Institutet.
Equipment and Measurements
The experiments were conducted in the human centrifuge at Karolinska Institutet and were performed in conjunction with another study (35). The rotational radius to the center of the centrifuge gondola was 7.2 m, and the roll angle of the gondola automatically adjusted so that the gondola floor was perpendicular to the resultant of the normal- and the centrifugal-gravity vectors. Because of the 28° tilt of the back rest, the magnitude of the gravity vector in the head-to-feet direction (Gz+) was, in reality, 1 G * cos 28° (0.88 g), 2 G * cos 28° (1.77 g), and 3 G * cos 28° (2.65 g). The small errors introduced by rounding off to the nearest integer for gravity have been neglected in the results reported here. Multiple slip rings at the center of rotation allowed for audiovisual monitoring, power supply, and transmission of physiological signals between the gondola and a control room. The instrumentation for respiratory measurements included a quadrupole mass spectrometer (model AMIS 2000, Innovision, Odense, Denmark) and a manually operated rotary valve assembly with a 4-liter rebreathing bag. The subjects breathed through a mouthpiece and wore a nose clip. Between the mouthpiece and the rotary valve, there was a unidirectional turbine-impeller flowmeter (KL Engineering, Northridge, CA) for measurements of expired flow and an inlet for gas sampling through a 10-m-long capillary tube to the mass spectrometer located at the center of the centrifuge. The volume of the instrumental dead space was 150 ml. Electrocardiogram was monitored from chest electrodes and a clinical monitoring system (type AS2, Datex, Helsinki, Finland). An accelerometer was positioned at heart level behind the back rest of the seat. Continuous signals were recorded at 20 Hz per channel in a digital data acquisition system. Before and after each experiment, the mass spectrometer was calibrated against gases of known composition. The flowmeter was calibrated with a 3-liter syringe within the experimental flow range. The response latency of the mass spectrometer was determined from a sudden, simultaneous change of gas composition and flow direction at the inlet of the sampling capillary. The latency between the flowmeter and the mass spectrometer signals was
3 s. The 95% rise time for the response to a step change in gas concentration was 150 ms. Light diodes were located at 60° lateral in the visual field of the subject. Subjects were instructed to report whether their peripheral vision was decreased as an early sign of cerebral hypoperfusion.
Experimental Procedures
The subjects came to the laboratory on two occasions: a first session for familiarization and another session, a few days later, for the experiment. The experiments were performed at 1, 2, and 3 G, four times at each level and with a randomized order between gravity levels. The resting subject sat in the gondola of the centrifuge and breathed air through the mouthpiece. At
1 min after reaching the desired gravity level, the subject started a combined rebreathing and SBW maneuver. After an expiration to functional residual capacity, the subject switched the rotary valve to rebreathe the full bag volume eight times at a rate corresponding to 3 s/breath following a metronome. After a final inhalation from the rebreathing bag, the subject switched the rotary valve and exhaled completely to residual volume (RV) at a constant flow rate of 0.5 l/s, aided by visual feedback from an airway pressure signal displayed on an liquid crystal display screen. Gas traces during the expiration to RV were analyzed for end-expiratory concentration deviations (phase IV amplitude), which, if present, would indicate poor intrapulmonary gas mixing at the end of the rebreathing maneuver. The subject then inhaled one vital capacity (VC) of cabin air and made a second expiration to RV, both at a rate of 0.5 l/s. A flow restriction in the breathing port to cabin air was dimensioned to give a differential pressure of 5 cmH2O between the external airway and the cabin at the desired flow rate during inspiration and expiration. The gas mixture used for rebreathing contained 35% O2 and 5% Ar. In addition, and for other purposes (35), the mixture contained 3% SF6, 5% He, 0.63% C2H2, 0.3% C18O, and balance N2. The rebreathing gas volume varied from 1 to 2 liters depending on the stature and the preference of the subject. Repetitions of the combined maneuver were separated by
10 min to permit elimination of foreign gases. At least 8 of these 10 min were at normal gravity.
Data Acquisition
After intermediate storage in the AMIS 2000 system, offline data analysis was performed with an Acknowledge 3.2 digital data-handling system (Biopac, Goleta, CA). Offline computations included algorithms for total dry pressure correction (41) and computation of calibrated values for all dry gas fractional concentrations. Also, concentration readings were corrected for the response latency of the mass spectrometer system, and gas volumes and flows were converted to BTPS when appropriate. The pulmonary capillary blood flow data obtained during the preceding rebreathing maneuver have been reported elsewhere (35) and were used to calculate stroke volume (SV) in the present study. Heart rate (HR) during the 15 to 5 s preceding the rebreathing maneuver was determined from the electrocardiogram, and SV was obtained as pulmonary capillary blood flow ÷ HR, with the assumption that the pulmonary capillary blood flow during the SBW maneuver was the same as that during the immediately preceding rebreathing maneuver. Flow was integrated to obtain expired volume.
Analysis of Expirograms
Three kinds of expirograms were generated. 1) Expired Ar concentration was plotted as a function of expired volume (Fig. 1). The Ar concentration at the end of the rebreathing maneuver and before the VC inspiration was defined as 100%, and the Ar in cabin air was defined as 0%. The resulting expirogram is analogous to a conventional SBW expirogram in which a homogenously distributed resident gas (classically N2) is diluted with one VC of another gas (classically pure O2). 2) Expired CO2 was plotted in a similar way, also normalized to the preinspiratory level by setting it to 100% and setting the CO2 level of cabin air to 0% (Fig. 1). 3) Finally, the ratio of the expired CO2 to expired Ar concentration (CO2/Ar) as defined above was plotted as a function of expired volume (Fig. 2). Henceforth, the terms Ar and CO2 will refer to %Ar and %CO2, as defined above, when not stated otherwise.
|
|
In our analysis, the alveolar part of the expirogram was divided into two parts: phase III and phase IV (17, 33). Several indexes were calculated: the size of VC, phase III slope, closing volume (CV), phase IV amplitude, and the amplitude of the cardiogenic oscillations (COS). VC was defined as the maximal expiratory volume. The start and end of the alveolar plateau were identified using a cursor, and phase III slope was determined as the least-squares best-fit line. The onset of airway closure was defined as the end of phase III and the onset of phase IV, although not by an iterative process as described by Guy et al. (17). CV was calculated from this point to the end of the expiration and was also expressed as a percentage of VC. Phase IV amplitude was calculated as the vertical distance between the extrapolated phase III slope and the maximal concentration deviation at the end of phase IV. Of the four repetitions at each gravity level, we used the data from the two experiments where the expired VC was larger or, if these two VC values differed by >0.5 liter, only the data from the experiment with the larger VC. We selected the two largest consecutive COS during phase III with Ar, CO2, or CO2/Ar concentrations plotted against volume. We used the R-R interval to find the local maxima and minima, referenced to the line already fitted to phase III. Inasmuch as COS is affected by the size of the SV (20), we normalized COS for changes in SV.
Rationale for the Present Analysis
The Ar value in the expirogram at any time represents the dilution of the resident gas during the preceding inspiration in the lung units that empty at a specific point in time. This is so, because after the rebreathing maneuver and before the VC inspiration, there will be minimal, if any, residual differences in Ar between lung units (43). CO2 (35) and, thereby, CO2/Ar will have an equally homogeneous distribution within the lung. The calculation of CO2/Ar is analogous to the ratio of soluble to insoluble marker gas when lung blood flow and diffusing capacity are calculated from gas traces obtained during the rebreathing maneuver (40); normalization of soluble gas against insoluble gas compensates for the effect of ventilatory distribution, rendering the soluble gas trace specific for the exchange of gas between the gas and the capillary blood in the lung. CO2/Ar would be unity if no CO2 was added from perfusion during the
20-s-long VC inspiration-expiration maneuver. Thus, to the extent that this ratio is higher than unity, it reflects the extent to which CO2 has been added to lung units by perfusion. The expirogram is considered to represent the sequential emptying of a series of lung units. These units are not necessarily anatomically confined units but represent groups of alveoli, the gas from which reaches the mouth at a certain point in time. Each expired Ar value represents a specific alveolar dilution (7, 22): VR/(
VU + VR) = Ar/100, where VR is the RV of the unit before inspiration, initially having an Ar equilibrium concentration of 100%, and
VU is the amount of 0% Ar gas received by a unit U. For a typical lung with an RV of 1.5 liters and a VC of 5 liters, one would obtain an overall dilution factor of (6.5 liters - dead space)/1.5, i.e.,
4, corresponding to an Ar value of
25.
Each unit has a certain circulatory CO2 delivery, which is assumed to be constant over the time of the maneuvers as a result of assumed constancy of cardiac output and mixed venous CO2 (25). Apart from the circulatory delivery of CO2, the amount of CO2 added to the air space of each unit is determined by the CO2 partial pressure difference between the mixed venous blood and the alveolar space of the unit. Two cases should be considered.
Case A. CO2 transfer into the alveolar space is limited by perfusion; i.e., the ventilatory dilution is so large that there is not sufficient CO2 influx through perfusion to fill the alveolar space to 100% within the 20-s duration of the VC inspiration-expiration maneuver. This is probably so in the present case when the ventilation-to-perfusion ratio for the lung is considered as a whole during the short-duration non-steady-state period of the VC inspiration-expiration maneuver; during the inspiratory phase, this ratio will be
5, and for the maneuver as a whole it will be
2.5.
Case B. Well-perfused units receive an excess of CO2 from perfusion during the VC maneuver and will then restore the initial CO2 before the expiration is terminated. The finding of expirograms with a time-variable CO2 level of <100% would speak against that possibility. A conservative calculation of the lung perfusion that would be required to replenish the CO2 level in the lungs as a whole within the first 5 s of expiration yields a value of >30 liters of blood per minute for the whole lung, which is clearly much in excess of the perfusion that could occur in any lung unit under the present conditions of rest in the sitting position. In summary, therefore, we estimate that it is justified to consider the present CO2/Ar expirograms to reflect perfusion heterogeneity.
The purpose of the present study was to assess inhomogeneities of ventilation and perfusion from variations in the Ar and CO2/Ar expirograms. For a time-varying concentration of a gas to occur in an expirogram, two conditions must be met at the same time: 1) the gas concentration must differ between lung units, and 2) lung units with different gas concentrations must empty sequentially. In this and previous studies in which noninvasive assessments of ventilation (17) and perfusion distributions (33) were performed in the lung, cardiogenic oscillations and phase IV amplitude have been used to assess the degree to which gas concentration differences occurred within the lung.
Statistical Techniques
ANOVA (STATISTICA 6.0, Statsoft, Tulsa, OK) with repeated-measures design with one dependent factor (gravity in the head-to-feet direction) was used to test for differences between gravity levels with respect to respiratory variables. Tukey's honestly significant difference multiple comparisons test was used as post hoc test. Results were considered statistically significant if P < 0.05, and all tests were two sided. Values are means ± SE, unless otherwise stated. To obtain percent changes, data were normalized to the average 1-G value of each subject.
| RESULTS |
|---|
|
|
|---|
|
|
Several parameters extracted from Ar expirograms (Ar parameters) changed significantly with increased gravity level, except COS for Ar, phase III slope for Ar, and CV for Ar. However, COS for Ar normalized for changes in SV showed a significant increase with gravity to
160% at 3 G (Fig. 3A), and CV for Ar also showed a significant increase to 160% when normalized for changes in VC (Table 1). There was a trend for an increasingly positive phase III slope for Ar (Table 1). The most obvious gravity-induced change in phase IV amplitude was a doubling of the amplitude that occurred at 2 G, with little or no additional change at 3 G (Fig. 3B).
Parameters extracted from CO2/Ar expirograms mostly showed significant increases with gravity, except COS for CO2/Ar and phase III slope for CO2/Ar; for the latter, however, there was a trend for an increasingly negative slope (Table 1). As for Ar and CO2, COS/SV for CO2/Ar increased significantly with gravity, but the increase from 2 to 3 G was much more modest than for Ar and CO2, if not absent (Table 1). Also for CO2/Ar, the most obvious change of phase IV amplitude was an approximate doubling of the amplitude from 1 to 2 G, with little or no difference between 2 and 3 G (Fig. 3B).
We analyzed whether parameters obtained for each individual from Ar expirograms were correlated with those from CO2 expirograms for the same gravity condition. The results are shown in Table 2. In summary, neither COS for Ar and COS for CO2 amplitudes nor phase III slopes were correlated in any of the conditions, but at 2 and 3 G there were strong correlations for CV and phase IV amplitude between Ar and CO2.
|
| DISCUSSION |
|---|
|
|
|---|
Vital Capacity
In the present experiments, VC was gradually decreased in hypergravity, most probably caused by the impaired chest movements imposed by the increased gravitational force. On the other hand, the reduced central blood volume due to blood pooling in dependent parts of the systemic circulation during hypergravity (23, 38) acts to increase VC.
Our data are in general accordance with previous results presented by Gustafsson et al. (16), even though their subjects had a slightly smaller hypergravity-induced decrease in VC.
Heart Rate and Stroke Volume
The HR and SV changes were generally in agreement with previous data from Rosenhamer (38) with progressive HR increase and SV reduction with increasing gravity. The basic mechanism behind the reduced SV is a decrease in effective circulating blood volume in the systemic (38) and pulmonary circulations (35) due to sequestration of blood in dependent parts of these circulations. The tachycardia is of baroreflex origin as a result of reduced arterial blood pressure at the level of the carotid baroreceptors (22), and this tachycardia will further contribute to the SV reduction in response to hypergravity (38).
Cardiogenic Oscillations
General. Heart-synchronous variations of gas concentration during a slow expiration are known as cardiogenic oscillations and were first demonstrated for CO2 during tidal breathing and for N2 during SBW maneuvers when rapidly responding gas analyzers for these gases became available (6, 12). It has been proposed that COS result from the direct mechanical action of the heart on the surrounding lung (13, 18) and/or the pulsations in the large pulmonary vessels (6) and/or time-dependent variations in thoracic blood content during the cardiac cycle (2). The now generally accepted concept that the overall cardiac volume does not change much during the cardiac cycle (9, 19) speaks against cardiac volume changes as the principal mechanism. Whatever the mechanism for the mechanical coupling between the heart and the lungs, the beating heart directly or indirectly provokes lung units with different gas concentrations to empty in an alternating manner, producing rhythmical variations of the relative contributions to the expirate from different populations of alveoli.
The amplitude of COS is considered to reflect the regional differences in gas concentration and the extent to which the beating heart affects the sequential lung emptying, so to interpret COS data, one has to consider both of these factors. Because cardiac movements and pulsations in intrathoracic vessels are related to the size of the SV, we have normalized COS amplitudes for SV in the present analysis. There is no clear definition of the size and location of regions that contribute to COS by alternating their emptying rate. However, experimental data obtained in humans by Arieli (1) point to a relatively peripheral location of the mixing point where concentration oscillations arise as a result of alternating contributions from lung units with different gas concentrations. On the other hand, Engel et al. (11) argued that gas concentration variations of such peripheral origin would be obscured by diffusion and asynchronous contributions at more central bifurcations. However, the experimental data and model analysis by Arieli indicate that asynchronous contributions at more central sites cause COS to become biphasic but not to be eliminated. These regions are not necessarily equivalent to the vertical regions (apex-to-base) that cause phase IV phenomena due to airway closure but, rather, originate from regions in the periphery on a scale larger than the acinus (32) but smaller than gross apical/basal regions (1). We therefore use the terms small-scale inhomogeneities in the distribution of ventilation and perfusion for phase III slope and COS to distinguish from large-scale (apex-to-base) inhomogeneities, which are reflected by phase IV phenomena, such as CV and phase IV amplitude.
Ar. Michels and West (26) studied COS for Ar and N2 during an SBW maneuver with an inhaled bolus of Ar at RV followed by O2. Experiments were done during parabolic flight, and the subjects performed the inspiration and expiration at 1 G, 1.8 G, or 0 G. Oscillation amplitudes were highest at 1.8 G and lowest at 0 G, and the authors suggested that this reflected larger Ar and N2 differences between lung units with increasing gravity, as a result of less homogeneous ventilation distribution.
This is in contrast to the report of Jones et al. (20). They performed SBW tests with a bolus of N2 delivered at RV and found lower COS amplitudes during exposure to high gravity than to normogravity in subjects sitting in a human centrifuge. The difference between those two studies that can account for the different results in COS might be the brief duration (10-15 s) of the hypergravity exposure before the measurement during parabolic flights and more of a steady-state situation in the human centrifuge. The longer period of hypergravity in the centrifuge will more effectively reduce the central blood volume and, therefore, also the SV. Therefore, it is interesting to note the COS response in the study of Jones et al., in which the subjects performed the inspiration part of an SBW maneuver at 4 G, and then the centrifuge was stopped, and the subjects performed the expiration at normal gravity. The result was larger COS than when the whole maneuver was performed at 4 G, and Jones et al. attributed this result to the sudden increase in venous return and SV on return to 1 G. This finding lends further support to the present use of SV as a normalizing parameter in the interpretation of COS.
In the present study, there was an
2-min period of hypergravity before the expirogram was recorded: 4-6 s of gradual gravity onset, 60 s of rest at hypergravity, 30 s of rebreathing maneuver, and 20 s of SBW maneuver. During this time, there is likely a more significant reduction of SV in sitting resting humans than during 10-15 s of hypergravity (1.8 G) in parabolic flight. The present constancy of COS for Ar across gravity conditions (Table 1) is therefore likely to be the result of two opposing influences on their amplitude: increased gravity, which is expected to produce larger interunit differences of dilution and Ar concentrations but, at the same time, decrease SV, thereby decreasing the influence of the heart on the lung. After having taken this into consideration by normalizing the COS for changes in SV, we found signs of gradual deterioration of the homogeneity of small-scale ventilation distribution with increasing hypergravity (Table 1, Fig. 3A).
CO2. The COS shown in the present CO2 recordings were 4-6% of the preinspiratory equilibrium level. COS are likely the result of CO2 concentration differences that originate from varying the dilution of CO2 between units during inspiration and varying the circulatory CO2 input to the gas spaces of the same units. In the theoretical case, that it is the units with the greatest dilution that have the least perfusion, the dilution and perfusion mechanisms would be in phase and act in the same direction and result in amplification of CO2 differences between units and, thereby, of COS. On the other hand, should the most well-ventilated units be those with the largest perfusion, COS for CO2 would be attenuated.
We analyzed the possible correlation between pulmonary function parameters extracted from Ar and CO2 expirograms (Table 2). The correlation coefficient was 0.30, which indicates that COS for these two gases did not correlate significantly. From this lack of correlation, we conclude that COS for Ar and COS for CO2 reflect fundamentally different phenomena to such an extent that CO2/Ar would provide new information not directly provided in the Ar or the CO2 expirogram.
CO2/Ar. Michels and West (26) studied COS for CO2 and O2 during a maneuver including hyperventilation, breath holding, and slow expiration. We considered such a maneuver unsuitable for use in a sustained high-gravity environment because of the risk that the accompanying hypocapnia would result in cerebral vasoconstriction and, thereby, increase the risk for a gravity-induced loss of consciousness. Instead, we used a different technique but with analog elements. The hyperventilation period in the study of Michels and West aimed at equilibrating the CO2 content in the lungs and, therefore, served the same purpose as the rebreathing maneuver in the present study. It also lowered the CO2 before a period of CO2 accumulation in the lung and, thereby, served the same purpose as the VC inhalation of CO2-free air in the present study. The breath hold during
15 s was to allow CO2 to accumulate in proportion to the blood flow in each lung unit; in the present study, CO2 transfer to the alveoli took place during the 20-s VC exhalation-inhalation-exhalation sequence. In the present study, the normalization of CO2 with respect to Ar compensated for differences in dilution during inspiration. The experiments of Michels and West were done during parabolic flight, and the subjects performed the breath hold and expiration at 1 G, 1.8 G, and 0 G. COS were largest at 1.8 G and smallest at 0 G, and the authors concluded that this was a result of less homogeneous perfusion distribution with increasing gravity.
In the present study, COS for CO2/Ar normalized for changes in SV showed a significant increase in amplitude from 1 to 2 G, with little or no further increase at 3 G compared with 1-G control (Table 1). These results indicate that the impairment of small-scale pulmonary perfusion homogeneity did not become more severe from 2 to 3 G. This is in contrast to COS for Ar, which showed a gradual change over 1-3 G. This difference in behavior between ventilation and perfusion suggests that, on a regional level, ventilation distribution is a relatively simple function of gravity-induced lung deformation.
Phase III Slope
During a VC expiration after an inhalation of an insoluble marker gas, the slope of phase III of the alveolar part of the expirogram represents the sequential emptying of lung units with different ventilations per unit lung volume and asymmetric gas transport at the acinar level (30). By studying these phenomena in microgravity, Guy et al. (17) found that the phase III slope was reduced by only 22% in sustained microgravity compared with 1 G in the standing position and concluded that the genesis of phase III slope was primarily nongravitational. The phase III slope thus appears to depend more on the emptying patterns of small regions with widely varying volume-to-ventilation ratios than on gravity-dependent sequences of emptying (4). The major part of the phase III slope arises from a complex interaction between diffusive and convective transport in the peripheral parts of the lung or diffusion-convective-dependent inhomogeneity (32), which is the major contributing mechanism to inhomogeneity during normal breathing in healthy subjects (5, 10). Indirect effects of the continuing gas exchange of soluble gases in the lung contribute to
10% of the phase III slope of an insoluble gas (3). Gustafsson et al. (16) showed that phase III slopes for He and SF6 increased gradually in hypergravity and were 142% and 163%, respectively, at 3 G compared with normogravity. Our data are in accordance with these results. There was a trend for an increasing phase III slope for Ar with a value at 3 G that was 154% of that at 1 G (Table 1).
Because the CO2/Ar trace is compensated for ventilatory transport phenomena, it reflects the effects of exchange of CO2 between the blood and the alveoli. We found a trend for the phase III slope for CO2/Ar to become more negative with increasing gravity, showing a trend for the lung perfusion to have a steeper gradient between lung units that empty early and those that empty late during expiration. However, the lower total pulmonary blood flow in hypergravity (35, 38) may also have contributed to the more-negative slope by reducing the direct effect of continuing gas exchange, which in itself would tend to add a positive component to the slope.
Phase IV Phenomena: CV and Phase IV Amplitude
Experiments in normal gravity have shown that airway closure is largely gravity dependent: flow becomes sequential at the end of the expiration as a result of progressive closure of airways in dependent lung units (8, 44). The reason is the nearly linear vertical gradient in pleural pressure, such that the pleural pressure exceeds airway pressure in dependent lung regions when approaching RV, thus favoring airway closure (21, 27, 42). Phase IV amplitude reflects the vertical gas concentration differences between lung units emptying before and after airway closure and, therefore, increases with increasing gravitational force (15, 20). However, the persistence of phase IV phenomena and airway closure in microgravity demonstrates that inhomogeneity of ventilation to some extent persists in microgravity (17, 33). This also demonstrates that it is merely the topographical sequence of lung emptying that is determined by gravity and not airway closure as such. The authors speculate that the presence of airway closure in the absence of gravity is, rather, caused by differences in mechanical properties between different lung units at low lung volumes, causing patchy, rather than regional, airway closure (17). For phase IV amplitude, it has been suggested that there is a 68% (34) to 75% (17) contribution of gravity at 1 G.
In the present study, phase IV amplitude and CV/VC increased in hypergravity for Ar and CO2/Ar (Table 1). The present Ar results could be compared with those of Jones et al. (20) obtained with a bolus technique. The present trend for an increase of CV (Table 1) is similar to data from the three subjects of Jones et al. Phase IV amplitude was not reported exactly as in the present study, but comparisons of the N2 content between the final and the penultimate expired liter of gas suggest a leveling off at >2 G as in the present study. Our results (CV/VC and phase IV amplitude) show that large-scale ventilation and perfusion distributions become more inhomogeneous in hypergravity, which is in agreement with previous studies using a xenon technique (15). Analysis of the correlation between the parameters (CV and phase IV amplitude) extracted from Ar and CO2 expirograms shows that the large-scale differences changed in the same manner with increasing gravity level (Table 2). This is not surprising, because the resident CO2 and Ar are equally influenced by air dilution and expiratory sequencing during the VC-SBW maneuver. Also the vascular engorgement of dependent lung regions will reduce airway dimensions and, thereby, promote airway closure. There were no significant further deteriorations at >2 G for large-scale distributions of ventilation and perfusion. These results suggest that there is a finite degree by which the lung tissue can be deformed by gravity and, possibly, that changes of intrapulmonary gas distribution beyond 2 G, if any, are mainly secondary to redistribution of the intrapulmonary blood volume (35).
The lack of change of phase IV amplitude for CO2/Ar between 2 and 3 G is in apparent contrast to previous findings that total lung blood flow and lung tissue volume decrease and increase, respectively, in a gradual fashion between 1 and 3 G (35). It must be borne in mind, however, that the increasing lung tissue volume reflects increasing sequestration of blood in dependent lung units. Together with a falling VC, this suggests that lung units with high perfusion to an increasing extent do not contribute to the expirate. Thus the lack of change of indexes of large-scale perfusion inhomogeneities between 2 and 3 G may be an effect of two counteracting mechanisms: one that causes an overall increased gradient of perfusion within the lung and another that decreases the population of lung units that contribute to the expirate. Using radioactive xenon, Glaister (14) scanned the lung in sitting subjects exposed to 1-3 G to measure apicobasal distribution of pulmonary blood flow. There was a gradual increase in the inhomogeneity of pulmonary perfusion distribution, in contrast to our results. However, there are several differences between the present study and Glaister's study that render a comparison more difficult: most importantly, the subjects in Glaisters' study were wearing inflated antigravity suits, which leads to pulmonary vessel engorgement, basal lung compression, and an increase in gas trapping.
Relation Between Phase III and Phase IV Phenomena
In the present study, there was a marked difference in the effect of hypergravity on phase III (COS/SV and phase III slope) and phase IV phenomena (phase IV amplitude and CV/VC). There was a trend for a gravitational effect on phase III slope, and COS/SV was significantly changed with gravity. However, in relative terms, gravity-induced changes were much larger for phase IV phenomena.
Prisk et al. (33) assessed pulmonary perfusion distribution from CO2 expirograms before and during spaceflight and showed that, in microgravity, the reduction in phase IV amplitude was much greater than the change in COS compared with 1-G control. They ascribed this difference to the fact that microgravity eliminates the apicobasal differences in perfusion, in contrast to the more small-scale mechanisms of inhomogeneity, e.g., differences in lung compliance within small regions of the lung that are not affected by gravity (33). At the same time, there were also small-scale ventilation and perfusion inhomogeneities that were affected by gravity, probably represented by small gradients in the dependent-to-nondependent direction within a given lung region. There seems to be a relation between the size of the area of interest and the gravitational influence: from the phase III slope, reflecting inhomogeneities mainly at the acinar level, which are not significantly affected by gravity, through COS at a level larger than the acinus, which are affected by gravity, and further to phase IV phenomena, reflecting apicobasal differences, which are severely affected by gravity.
Finally, we conclude that the validity of the present method is supported by a comparison with results from similar studies to the extent that such data exist. For the insoluble ventilation distribution marker Ar, this is true up to 2 G for COS (26) and up to 3 G for phase III slope (16) and phase IV amplitude (20). For the soluble perfusion distribution marker CO2/Ar, this is true for COS and phase IV amplitude up to 2 G (26).
| GRANTS |
|---|
|
|
|---|
| ACKNOWLEDGMENTS |
|---|
|
|
|---|
| FOOTNOTES |
|---|
The costs of publication of this article were defrayed in part by the payment of page charges. The article must therefore be hereby marked "advertisement" in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.
| REFERENCES |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
S. Montmerle and D. Linnarsson Effects of gravity and blood volume shifts on cardiogenic oscillations in respired gas J Appl Physiol, September 1, 2005; 99(3): 931 - 936. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Montmerle, P. Sundblad, and D. Linnarsson Residual heterogeneity of intra- and interregional pulmonary perfusion in short-term microgravity J Appl Physiol, June 1, 2005; 98(6): 2268 - 2277. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Rohdin, J. Petersson, M. Mure, R. W. Glenny, S. G. E. Lindahl, and D. Linnarsson Distributions of lung ventilation and perfusion in prone and supine humans exposed to hypergravity J Appl Physiol, August 1, 2004; 97(2): 675 - 682. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| Visit Other APS Journals Online |