|
|
||||||||
1Department of Physiology, University Medical Centre Nijmegen, 6500 HB, Nijmegen, The Netherlands; and 2Institute for Exercise and Environmental Medicine, Presbyterian Hospital of Dallas and University of Texas Medical Center, Dallas, Texas 75321
Submitted 6 August 2003 ; accepted in final form 22 November 2003
| ABSTRACT |
|---|
|
|
|---|
venous compliance; venous flow resistance; lower body negative pressure tolerance; strain gauge plethysmography
Recent studies in hindlimb-unloaded rats have shown an increase in systemic and mesenteric venous compliance and attenuation of the effect of norepinephrine on the reservoir function in these capacitance beds (14, 15). These studies suggest that altered venous hemodynamics may contribute to the excessive reduction in stroke volume in the upright posture, observed universally after microgravity exposure. In humans, previous studies of venous vascular properties in the leg after bed rest or spaceflight show conflicting results, with some studies reporting an increase in leg compliance (5, 12, 33), others reporting no changes (2, 16, 35, 49), and one study reporting a decrease (7). In only three of these studies orthostatic tolerance or lower body negative pressure (LBNP) tolerance was examined (2, 16, 35), and none of the studies addressed the relationship between changes in venous compliance and changes in orthostatic tolerance. If such a relationship is present, it is possible to assess whether changes in venous compliance play a detrimental or beneficial role in the pathogenesis of post-bed rest orthostatic intolerance. In contrast to subjects after bed rest or spaceflight, patients with a spinal cord injury, and thus severe prolonged deconditioning, clearly have decreased venous compliance (25). This adaptation has been hypothesized as being an important adaptive mechanism, which may protect these patients, with lack of supraspinal sympathetic control, from orthostatic hypotension.
It is unclear whether the adaptations in the venous system of the leg in humans reflect a generalized systemic adaptation of the venous vasculature, similar to that observed in animals, or rather a regionally specific phenomenon related to altered hydrostatic gradients or to disuse atrophy. We reasoned that for upright humans, because hydrostatic forces and use patterns differ between the legs and the arms, the adaptation of these vascular beds to microgravity may differ and thus may be used to distinguish between local vs. generalized "deconditioning effects." If a systemic effect is present then generalized venous changes, for instance in the mesenteric region, may importantly alter orthostatic tolerance. In a recent study a limited, but significant effect of pelvic venous pooling on LBNP tolerance was shown (22). The aim of this study, therefore, was to assess changes in venous properties (capacitance, compliance, and venous flow resistance) of the leg and arm before (pre) and after (post) 18 days of strict head-down tilt bed rest in healthy subjects. In addition, we hypothesized that there would be a direct, linear relationship between changes in venous vascular properties and changes in LBNP tolerance.
| METHODS |
|---|
|
|
|---|
Eleven healthy subjects (10 men, 1 woman) participated in the study after providing written, informed consent. These subjects represent a subset of subjects whose information regarding cardiac compliance (29) and regulation of muscle sympathetic nerve activity (39) has been reported previously. Their mean age was 24 ± 6 yr (range 1833 yr), height averaged 178 ± 4 cm, and weight was 79.1 ± 9.7 kg. Subjects did not smoke, did not use recreational drugs, and had no significant medical problems as determined by medical history and a comprehensive physical examination. Body composition was obtained by use of standard underwater weighting techniques (46). None of the subjects was endurance trained, and subjects were excluded if they exercised more than three times a week for more than 30 min with either dynamic or static exercise. The study was approved by the Institutional Review Boards of the University of Texas Southwestern Medical Center and Presbyterian Hospital of Dallas.
Procedures
Bed rest protocol. After the initial series of experiments, subjects were placed at complete bed rest, with 6° head-down tilt. The subjects were allowed to elevate on one elbow for meals, but otherwise they were restricted to the head-down position at all times. They were housed in the General Clinical Research Center at the University of Texas Southwestern Medical Center, and they were given a standard diet, consisting of 2,857 ± 629 cal/day including 5.3 ± 1.2 g/day of sodium. Fluids were allowed ad libitum, but all fluid intake and urine output was carefully recorded. The same series of experiments were repeated after 18 days of bed rest.
LBNP. LBNP was achieved by placing the subject in a Plexiglas box, sealed at the level of the iliac crest. Suction was provided by vacuum pump controlled with a variable autotransformer.
Experimental conditions and protocol. Mercury strain gauge venous occlusion plethysmography (3, 51) was used to assess leg and arm venous vascular characteristics. For pre- and post-bed rest measurements, subjects were placed in the supine position with the leg and arm slightly elevated 1520° above heart level. Subjects were supine for 2030 min before the start of the measurements. They were not allowed to sleep before or during data collection. After instrumentation of the subject, test procedures were started with a venous occlusion of 20 mmHg, followed by subsequent cuff pressures of 40, 60, and 80 mmHg. The effective pressure on the venous system was estimated as 0.8 times the cuff pressure (3). The occlusions at 20, 40, 60, and 80 mmHg were sustained for 1, 2, 3, and 4 min, respectively. One-minute breaks between occlusions allowed for new baseline formation and prevented excessive edema formation. This protocol was designed with relatively short venous occlusions to emphasize assessment of the venous contribution to calf and arm compliance rather than capillary filtration, as has been reported previously (49). On the basis of pilot data, the protocol allowed us to achieve a plateau in virtually all cases. In six subjects, studied three to four times over a period of 1 yr, the typical error of this measurement (calculated as coefficient of variation) was 9.6%.
Maximal orthostatic tolerance was measured by using a ramped LBNP test, as described earlier (29). In short LBNP started at -15 mmHg and then increased to -30 and -40 mmHg for 5 min each, followed by an increase in LBNP by -10 mmHg every 3 min until signs or symptoms of presyncope were achieved. Presyncope was defined as a decrease in systolic blood pressure below 80 mmHg or as a decrease below 90 mmHg with symptoms of lightheadedness, nausea, or diaphoresis; or progressive symptoms of presyncope causing the subject to request a discontinuation of the test. True hemodynamic end points were reached in 95% of the tests. The cumulative stress index (in mmHg·min) was calculated as the sum of the product of negative pressure and duration at each level of LBNP and was used as a continuous measure of orthostatic tolerance.
Measurements
Venous occlusion plethysmography. Mercury-in-Silastic strain gauges were stretched around the largest girth of the right calf and forearm. Thigh and upper arm pressure cuffs were connected to a rapid cuff inflator (model EC-4, Hokanson, Bellevue, WA) to ensure rapid and accurate filling and deflating of the cuff. Data signals were amplified and printed on a strip-chart recorder (Astromed), after which they were analyzed manually. A typical individual venous occlusion curve and pressure-volume curve are illustrated in Fig. 1. From the plethysmographic recordings the following parameters were calculated; the method of analysis of recordings was described in detail elsewhere (25). Briefly, venous volume variation (in ml/100 ml) was defined as the maximal relative volume increase in the limb at a certain cuff pressure; venous volume variation at different occlusion pressures represents the pressure-volume curve. Compliance (ml·100 ml-1·mmHg-1) was derived from the slope of the pressure-volume curve. Venous emptying rate (in ml·100 ml-1·min-1) was calculated as the slope of the tangent at the curve 0.5 s after cuff release (3). The time 0.5 s after cuff deflation was chosen to avoid any cuff artifact. The effective pressure of the cuff on the venous system at 0.5 s was calculated by using the pressure-volume curve (3). A pressure-emptying curve was then drawn, indicating the relationship between effective cuff pressure and the venous emptying rate. Venous flow resistance (in mmHg·ml-1·100 ml·min) was calculated, by analogy with Ohm's law, as 1 divided by the slope of the pressure-emptying curve (3).
|
Limb volume. Leg and arm circumferences were measured at fixed positions before and after the bed rest period. Total limb volume was then calculated with a Simpson's rule type of summation of multiple disks, as described by Thornton et al. (47, 48).
Statistics
For each individual subject, compliance and venous flow resistance were determined from the individual pressure-volume and pressure-emptying curve. Variables were compared before and after bed rest with a paired Student's t-test by using SPSS 10.0 computer software (SPSS, Chicago, IL). Data are presented as means ± SD. The pressure-volume and pressure-emptying curves present means ± SE. To test for a linear relationship between changes in leg compliance and changes in LBNP tolerance, a linear regression analysis was performed. The statistical significance level was set at 5%.
| RESULTS |
|---|
|
|
|---|
Body mass and limb volume before and after bed rest are presented in Table 1. Data are from 10 subjects, because of missing data post-bed rest of one subject. After 18 days of head-down tilt bed rest, total body mass was unaltered, but average lean body mass decreased significantly by 1.9 kg. Arm and leg volume did not change during the bed rest period.
|
Venous Volume Variation and Compliance
Venous volume variations of the arm and leg are presented in Table 2. Figure 2 depicts the pressure-volume curves and their slopes, which define compliance. Venous volume variation of the leg was significantly lower at any given occlusion pressure after bed rest compared with before bed rest, whereas no differences in venous volume variation could be observed in the arm. Compliance of the venous system of the leg was significantly decreased after 18 days of bed rest (pre: 0.048 ± 0.007 ml·100 ml-1·mmHg-1, post: 0.033 ± 0.007 ml·100 ml-1·mmHg-1; P < 0.01) and did not change in the arm (pre: 0.065 ± 0.014 ml·100 ml-1·mmHg-1, post: 0.064 ± 0.016 ml·100 ml-1·mmHg-1).
|
|
Venous Flow Resistance
Venous flow resistance (the inverse of the slope of the pressure-emptying curve; Fig. 3) increased significantly in the leg after the bed rest period (pre: 1.73 ± 1.08 mmHg·ml-1·100 ml·min, post: 3.10 ± 1.00 mmHg·ml-1·100 ml·min; P < 0.05) and did not change in the arm (pre: 1.22 ± 0.32 mmHg·ml-1·100 ml·min, post: 1.26 ± 0.64 mmHg·ml-1·100 ml·min). Venous flow resistance data are from 10 subjects because of insufficient data from one subject.
|
LBNP Tolerance and Its Relation With Leg Venous Compliance
LBNP tolerance, expressed as cumulative stress index, was reduced post-bed rest compared with pre-bed rest in all subjects (pre: 931.6 ± 381.7 mmHg·min, post: 746.9 ± 238.7 mmHg·min; P < 0.01).
The relation between changes induced by bed rest in leg venous compliance and changes in LBNP tolerance are depicted in Figure 4. Simple linear regression resulted in a correlation coefficient of 0.43, the R2 was 0.19, the F test had a significance of 0.183. Therefore, the correlation coefficient is not significantly different from 0, and in this data set there is no proof that a correlation is present.
|
| DISCUSSION |
|---|
|
|
|---|
The results of our study indicated a significant reduction of
30% in leg venous compliance after bed rest exposure and a significant reduction in venous volume variation, ranging from -34 to -54% depending on the cuff pressure applied. Bed rest can influence venous characteristics by several mechanisms. We will first focus on several mechanisms that can explain a decrease in venous compliance. Later on in the discussion, we will examine potential explanations for different outcomes between this and other studies.
Possible Mechanisms for a Reduction in Leg Compliance With Bed Rest
First, bed rest is an extreme form of physical inactivity. Several studies have shown that calf venous compliance is decreased in sedentary subjects compared with endurance-trained athletes (32, 36). Some investigators have argued that physical activity affects venous compliance mainly through changes in the venous vessel wall and less by changes in calf muscle mass (36). This interpretation is in accordance with the observation in the present study of significant changes in venous compliance in the absence of changes in leg volume and probably only minor changes in leg muscle mass. In other bed rest studies (5, 11, 12, 30, 33), muscle atrophy was more prominent, and this may in part explain differences between studies as is discussed further below. Other investigators have also shown that calf compliance is decreased in sedentary compared with active subjects and that it is even more decreased in spinal cord-injured individuals (50). A spinal cord injury leads to muscle paralysis below the level of injury and may be considered as "a model of nature" for extreme inactivity. One study investigating venous vascular function in chronic spinal cord-injured patients observed a 50% reduction in lower limb venous compliance compared with able-bodied individuals (25). Even when such patients have been studied in a relatively early phase, i.e., 8 wk, after the injury, a 30% reduction in leg venous compliance in spinal cord-injured patients compared with healthy controls has been observed (19). Together these data provide convincing evidence that inactivity causes decreased venous compliance.
Second, head-down tilt bed rest not only reduces physical activity but also alters gravitational gradients within the circulation, which may have effects on venous vascular function both directly, via hydrostatic forces, and indirectly, via cardiovascular reflex responses. For example, in the upright posture in humans, hydrostatic forces exerted on leg veins are considerably higher than the hydrostatic forces affecting arm veins. The specific venous vascular effect of microgravity is therefore likely to be more pronounced in leg veins. In this study, 18 days of strict bed rest deconditioning induced no significant differences in arm venous vascular properties, arguing against a systemic effect of bed rest deconditioning on the venous system. These findings are in agreement with the results of an earlier study (2) that showed no significant changes in arm venous compliance during a less strict 20-day bed rest regime. Similarly, a recent study reported diminished venoarteriolar responses in the skin of the legs after 14 days of head-down bed rest, whereas venoarteriolar responses in the arm were unchanged (52). This differential response provides further evidence that vascular function may be affected differently by head-down bed rest in the leg and in the arm due to either marked differences in the change in hydrostatic gradients or possibly to differences in the changes in activity patterns in the upper vs. lower limbs.
Another adaptation to the upright posture may be greater
-adrenergic receptor sensitivity in arteries of the leg than in the arteries of the arm (38). Moreover, as a result of sympathoexcitation via the muscle pressor reflex, pressure-volume curves in the arm and the leg are shifted downward, with no effect on compliance; thus the unstressed volume is decreased by sympathetic activation, whereas the distensibility is unchanged (23). Finally, epinephrine and norepinephrine cause venoconstriction in the human forearm and
-adrenoreceptor antagonists have been shown to increase forearm venous compliance (37). Furthermore, spaceflight and hindlimb unloading have been shown to decrease sensitivity to norepinephrine in
1-adrenoreceptors in the rat vena cava (43). In a study by Wecht et al. (50), a relationship between sympathetic vasomotor tone and venous compliance was shown for spinal cord-injured individuals and sedentary and active controls, with the most active subjects having the highest compliance. In addition, Fu et al. (20) have reported a negative correlation between baseline muscle sympathetic nerve activity and leg venous compliance and a negative relationship between changes in muscle sympathetic nerve activity and changes in leg venous compliance. Thus when sympathetic activity increases leg compliance decreases. Together these findings suggest, but do not prove, that the sympathetic nervous system can affect venous vascular function, and may provide a unifying mechanism for the wide variation in observations after bed rest and spaceflight. For example, data from the first and second Spacelab Life Sciences Program (SLS-1 and SLS-2) have demonstrated that during quiet standing after spaceflight, there was less, rather than more, pooling of blood in the lower extremities (4). Subsequently, the Neurolab investigators (28) showed that sympathetic nerve activity directed to the skeletal muscle of the lower limb is increased in both the supine and upright positions after spaceflight, which could cause venoconstriction and therefore limit venous pooling. Although the resting sympathetic nerve activity was changed only minimally in the subjects reported in the present study (39), a wide range of alteration in resting sympathetic nerve activity by micro-gravity has been reported in the literature including a decrease (44), increase (26, 34, 45), and no change (39). We speculate that alterations in sympathetic nerve activity may be different among these studies and that these alterations explain at least part of the differences in leg venous vascular properties. Assessment of venous characteristics during sympathetic activation before and after bed rest may provide additional insight, but was not possible using our study design.
Whether venous characteristics play an important role in the complex pathogenesis of orthostatic intolerance is still unclear. Some investigators have observed a decreased compliance in patients with idiopathic orthostatic intolerance. However, it is not clear whether these changes are beneficial or not (18). Similarly the role of a decrease in compliance in the pathogenesis of post-bed rest orthostatic intolerance is unclear. The venous system serves as a reservoir for adjustment to cardiovascular change. Whereas a decrease in compliance may protect from venous pooling during standing, it also limits the reservoir function and thus the volume that can be mobilized by sympathetic stimulation or the muscle pump. Thus in our opinion the changes in compliance and venous volume variation reflect adaptations to microgravity and deconditioning, but these changes may be more or less beneficial, depending on the specific circumstances. However, the absence of a relationship between changes in compliance and changes in orthostatic tolerance in this study suggests neither a beneficial nor a detrimental role for venous characteristics of the leg in orthostatic intolerance after simulated microgravity. This absence of a relationship between changes in compliance and changes in orthostatic tolerance is in accordance with a study by Engelke et al. (16), who demonstrated a decrease in orthostatic tolerance after bed rest in the absence of changes in leg venous compliance.
The fact that we only used simple linear regression for the assessment of the role of changes in leg venous compliance in the development of post-bed rest orthostatic intolerance leaves the possibility that there may be a role for venous changes but that this role is overridden and masked by changes in other factors such as cardiac function and blood volume. However, if changes in venous compliance would play a dominant role in the pathogenesis of post-bed rest orthostatic intolerance, then linear regression should have provided a significant result. Although we did not assess the role of abdominal or pelvic venous function, the absence of changes in venous compliance in the arms argues against systemic effects of bed rest on the venous system. Therefore, it is unlikely that systemic venous alterations contribute to orthostatic intolerance after bed rest.
Venous flow resistance, which indicates venous elasticity and resistance to venous flow, increased by almost 80% in this study. Data on effects of bed rest on venous emptying parameters are scarce. Louisy et al. (30, 33) reported an increase of
3050% in half-emptying time after bed rest, which suggests increased venous flow resistance despite an increase in venous compliance. In one of these studies, venous emptying rate at 6 s after cuff release was reported to be increased (30); however, this cannot be compared with our data, which reflect early (0.5 s) and not late venous emptying (6 s). Early venous emptying may be a passive effect based on elastic recoil of the venous wall, whereas late venous emptying may be an actively regulated process (40). In accordance with our results, venous emptying rate at 0.5 s has been reported to be significantly lower in the spinal cord-injured population (25, 50), with an almost doubled venous flow resistance (25). It has been postulated that this is due to decrease in venous cross-sectional area as a result of venous atrophy (25).
Comparison With Previous Bed Rest and Spaceflight Studies
Differences in outcome among bed rest and spaceflight studies may be explained by several factors, in addition to the already discussed variation in sympathetic nerve activity changes. One additional explanation for the reported differences may be related to subject selection. Our subjects were essentially completely sedentary before the study. None of the other studies reported on the fitness status of their subjects, except for one study by Louisy et al. (31). In that study, the subjects were very well-trained divers and a great increase in compliance of 108% after bed rest was reported. In prior studies, increased compliance has been shown to be correlated to reduction in calf muscle volume (10, 12), and muscle atrophy has been postulated as an explanation for increased compliance, resulting in orthostatic intolerance in some (5, 6, 1012, 33), but not all (27), studies. However, in the present study no leg or arm volume changes were observed during the bed rest period, indicating only minor muscle atrophy. Muscle atrophy after bed rest will likely be more pronounced in trained athletes. If other studies included subjects that were well trained and had more calf muscle volume, muscle atrophy may have had a disproportionately great influence on compliance and may have obscured other changes in calf venous properties favoring a decrease in compliance. In two separate studies Louisy and colleagues (30, 33) have shown that after an initial rise, compliance began to decrease after 20 or 26 days of bed rest. Whereas changes in compliance were related to changes in leg volume during the first 28 days, this relation was absent when compliance began to decline. We speculate that the initial rise may have been related primarily to prominent muscle atrophy in relatively trained subjects. After this atrophy had plateaued, the subsequent decrease in compliance reflected the primary effect of reduced hydrostatic gradients and vascular deconditioning. Additional support for this speculation can be found in a bed rest study of 118 days in subjects who were specifically selected by an extended physical examination of the Russian Space Agency and showed a decrease in venous compliance (7). This study provides further evidence that even in well-trained subjects during induced deconditioning, after an initial increase, venous compliance will decrease because of factors other than muscle atrophy.
Another explanation for differences among studies may be related to methodological differences in determining venous vascular properties. We chose this specific method because it makes our data directly comparable to the data from the SLS Spacelab missions. Because our plethysmography method represents a more classical approach, it was modified to minimize the shortcomings that were recently addressed in a paper introducing a new method to measure venous compliance (23). Our method has been shown to be reproducible over prolonged periods of time with a typical error of measurement of <10%. The present study was designed to measure venous volume variation at multiple occlusion pressures, so we were able to construct pressure-volume curves and report true compliance, without the assumption of a venous pressure of zero at cuff pressure zero. Several studies (2, 11, 12, 30) measured venous volume variation at only one occlusion pressure. When a pressure-volume curve is constructed from measurements at multiple occlusion pressures the line of best fit often does not intersect the y-axis at zero, and the slope of this line represents compliance. Simply dividing the volume variation at one cuff pressure by that cuff pressure may easily over- or underestimate compliance. In a recent paper, Risk et al. (41) argue for a biphasic or exponential approach to compliance analysis. However, in this paper, the linear model is described as a reasonable model and as a good model for pressures between 25 and 45 mmHg. On the basis of the overall data presented in Fig. 2A, we are confident that a biphasic or exponential analysis of data would not have altered our conclusions.
In several studies (5, 30, 31, 33), the end of venous occlusion was defined as the volume change reaching a plateau. If prolonged occlusion periods are used to reach a plateau, and the slow volume increase at the end of the filling curve is only due to interstitial fluid accumulation, then compliance may be overestimated. Furthermore, if capillary filtration is increased after bed rest as was shown in a previous study (7), compliance is even further overestimated. In the present study, breaks between occlusions allowed for new baseline formation to prevent unwanted effects of long-maintained high venous pressures, such as edema formation and vascular wall "creep." The protocol was designed with relatively short venous occlusions to emphasize venous contribution to volume variation rather than capillary filtration (49). With this protocol, we managed to achieve a plateau in most of the cases. This plateau in limb volume represents a steady state between arterial inflow and venous outflow; therefore, a decreased leg blood flow, as has been reported previously post-bed rest (33), cannot have caused an underestimation of venous compliance in the present study.
In conclusion, we have demonstrated that 18 days of strict head-down tilt bed rest reduces venous volume variation and venous compliance in the legs and increases venous outflow resistance. The fact that no such changes were observed in the arms suggests that this change is a direct effect of altered hydrostatic gradients and/or changes in physical activity rather than a systemic effect of bed rest deconditioning on the venous vascular system. We were unable to relate any changes in leg venous vascular properties to measures of orthostatic tolerance and thus conclude that, similar to findings after spaceflight, alterations in venous compliance do not play a major role in orthostatic intolerance after head-down tilt bed rest.
| ACKNOWLEDGMENTS |
|---|
|
|
|---|
Present address of J. A. Pawelczyk: Noll Physiological Research Laboratory, Pennsylvania State University, University Park, PA 16802.
GRANTS
This study was supported by National Aeronautics and Space Administration NSCORT Grant NGW 3582 and National Institutes of Health Grant MO1-RR-00633 (General Clinical Research Center grant).
| FOOTNOTES |
|---|
The costs of publication of this article were defrayed in part by the payment of page charges. The article must therefore be hereby marked "advertisement" in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.
| REFERENCES |
|---|
|
|
|---|
O2 reduction associated with age, gender, and aerobic capacity. Aviat Space Environ Med 57: 17-22, 1986.[Medline]
1-adrenoceptors in rat vena cava. J Appl Physiol 78: 1882-1888, 1995.This article has been cited by other articles:
![]() |
P. Arbeille, P. Kerbeci, L. Mattar, J. K. Shoemaker, and R. L. Hughson WISE-2005: tibial and gastrocnemius vein and calf tissue response to LBNP after a 60-day bed rest with and without countermeasures J Appl Physiol, April 1, 2008; 104(4): 938 - 943. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. C. E. de Groot, M. W. P. Bleeker, and M. T. E. Hopman Ultrasound: a reproducible method to measure conduit vein compliance J Appl Physiol, May 1, 2005; 98(5): 1878 - 1883. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. W. P. Bleeker, P. C. E. De Groot, F. Poelkens, G. A. Rongen, P. Smits, and M. T. E. Hopman Vascular adaptation to 4 wk of deconditioning by unilateral lower limb suspension Am J Physiol Heart Circ Physiol, April 1, 2005; 288(4): H1747 - H1755. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. P. Hernandez and W. D. Franke Age- and fitness-related differences in limb venous compliance do not affect tolerance to maximal lower body negative pressure in men and women J Appl Physiol, September 1, 2004; 97(3): 925 - 929. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| Visit Other APS Journals Online |