1Department of Physiology, Institut de Médecine Aérospatiale du Service de Santé des Armées, F-91223 Brétigny sur Orge; 2Centre Principal d'Expertise Médicale du Personnel Navigant, F-92141 Clamart; and 5Direction Centrale du Service de Santé des Armées, AST-REC, F-00459 Armées, France; 3Nestec SA, Nestlé Research Center, Vers-chez-les-Blanc, 1000 Lausanne 26, Switzerland; and 4Air Force Research Laboratory, Brooks Air Force Base, San Antonio, Texas 78235
Submitted 10 October 2002 ; accepted in final form 25 August 2003
| ABSTRACT |
|---|
|
|
|---|
sleep architecture; alertness; time zones; resynchronization; drugs
4 h, and this level can be maintained for 46 h without overshooting the unwanted-effect threshold (Fig. 1) (6). Furthermore, it could be suggested that there is a possible role of caffeine on circadian rhythmicity by acting on A2b adenosine receptors of the pineal gland (36). We hypothesized that Mlt and SRC could, respectively, improve sleep and mitigate daytime sleepiness after transmeridian flights. The aim of our study was to compare the effects of SRC with those of Mlt on recovery sleep and daytime sleepiness after a seven-time zone eastbound flight, by using subjective and objective methods. This work was part of a large, real-world French-American study called "Operation Pegasus" in which
140 physiological, psychological, and biological parameters were measured (18, 25).
|
| METHODS |
|---|
|
|
|---|
This double-blind, randomized, placebo (Pbo)-controlled study was conducted on 27 healthy volunteers from a US Air Force Reserve Unit that was representative of the US population [18 men and 9 women; 15 Caucasians, 9 Hispanics, and 3 African-Americans; age: 35.3 ± 8.1 yr (age range: 1947 yr); weight: 77.6 ± 15.8 kg; height: 170 ± 10 cm]. They underwent a medical evaluation before participation, including biological sampling and EEG. They also were examined by a psychiatrist and a specialist of sleep, who found no history of psychiatric or sleep disorders for all subjects. Horne and Östberg's questionnaires (16) showed that they were neither morning nor evening types; they habitually went to bed between 2300 and 2400 h and woke up between 0600 and 0700 h with a sleep duration ranging from 6.5 to 7.5 h. They had not experienced a transmeridian flight in the 2 mo before their enrollment in this study. They were nonsmokers and did not consume large amounts of xanthine-based beverages on a regular basis (coffee, tea, and cola: equivalent to <3 cups/day), nor had they taken psychotropic drugs or Mlt in the 3 mo before the study. They abstained from drinking alcohol or caffeine-containing beverages during the experiment; this commitment was strictly controlled by the experimenters. They gave informed, written consent before participation. In accordance with the 1964 Declaration of Helsinki, the experimental protocol was approved by the Human Ethics Committees of the Robert Ballanger Hospital, Aulnay sous Bois, France.
Experimental Protocol
See Fig. 2. The subjects were housed and trained at Brooks Air Force Base in San Antonio, Texas over 6 days, and their routines were identical. During the first 5 days, they were familiarized with the procedures and the experimental tests and measurements, including the nocturnal EEG. Baseline data were obtained during the last night (N-1) and day (D-1) to avoid the first-night effect (1). The flight was scheduled on day 0 (D0) at 1500 (US time) for a seven-time zone eastbound flight to Mont de Marsan, France. According to the test protocol, the subjects were prohibited from sleeping during the flight so that they remained awake 33 h from last awakening at Brooks Air Force Base to first sleep in France. During the flight, they played cards or read and had to complete sleep logs and questionnaires at regular intervals; their state of wakefulness was checked subjectively by the experimenters. The arrival was on D1 at 0600 (French time), and recovery lasted 10 days (D1D10) and 9 nights (N1N9). Before and after the flight, the subjects were required to follow the same daily routine: wake up at 0700 (beginning of light exposure), breakfast at 0800, morning tests between 0900 and 1200, lunch between 1230 and 1330, evening tests between 1400 and 1700, light muscular activity (walking in the woods) between 1730 and 1830, dinner at 1930, fitting of EEG electrodes from 2000, leisure (reading, games) until bedtime at 2300 (lights off). During the morning (09001200) and afternoon (14001700) test periods, when not napping, subjects followed a rigorous course of activities involving cognitive and physical performance testing (18). The subjects were confined to their rooms each evening, and the dormitories were frequently patrolled by the investigators; they were restricted to a narrow area on base and never away from supervision during the day. Normal daylight and nighttime darkness conditions were the same for all subjects throughout the experiment to avoid any bias related to a shift in circadian rhythms. None of the subjects slept, ate, drank, or performed uncontrolled physical activity outside the authorized periods.
|
The 27 subjects were allocated randomly into three parallel groups, each containing 3 women and 6 men, to be administered either 300 mg SRC, 5 mg Mlt, or Pbo. SRC (300 mg) was administered from D1 to D5 at 800; 5 mg synthetic Mlt on D-1 (1700), D0 (1600), and from D1 to D3 (2300); and Pbo in the same schedule (Fig. 2). The Mlt intake schedule corresponded, before, during, and after the flight, to bedtime in France. Mlt with a degree of purity of 100% (measured by HPLC) was provided by Helsinn Chemicals (via Industria, Biasca, Switzerland), and SRC and Pbo (lactose) by Nestec Research Center (Lausanne, Switzerland). The pharmacokinetics of SRC are shown in Fig. 1. Mlt, SRC, and Pbo were conditioned in capsules by Nestec, according to standard double-blind procedures.
Measurements
Sleep. Baseline and recovery sleep architecture was assessed from standard polysomnographic recordings, including electroencephalography (C3/Cz, O1/O2, referenced to an A1 ground electrode on the mastoid apophysis), electrooculography of each eye (oblique and horizontal derivations), and chin electromyography. Polysomnography electric signals were recorded by using TEAC recorders (Tekelec France, Sèvres, France) and were then sampled, amplified, and stored by using a portable Medilog 90002 (Oxford Medical Instruments, Abingdon, UK) from 2300 to 0700 during the baseline (N-1) and recovery (N1N9) nights (Fig. 2). EEG recordings were scored in 30-s epochs, according to standard criteria (26), by a researcher who was unaware of the medication taken (SRC, Mlt, or Pbo). We calculated the following for each night: sleep period time (SPT) (time from falling asleep to last awakening), total sleep time (TST) [difference between SPT and wakefulness after sleep onset (WASO)], sleep efficiency index (TST-to-time in bed ratio), and sleep onset latency (SOL) (time from lights out to first episode of stage 2). We also measured slow-wave sleep (SWS) and rapid eye movement (REM) sleep latencies (time from first stage 2 to first epochs of stage 3 and REM sleep, respectively). Each stage of sleep was analyzed by measuring total duration and percentage of TST; the number of SWS and REM sleep episodes were also counted.
For this long (
2 wk) field study, sticking electrodes on the skull by using collodion would have been risky (risk of skin abrasion) and would have taken too much time. Therefore, we used caps on which the electrodes were inserted (electrocap, Vickers Medical France, Marne la Vallée, France), and, after the cap was slipped on the head, conductive paste was injected through each electrode. For reasons of convenience (feeling of discomfort and request for shampooing before bedtime, which was impossible), some women refused to wear the cap every night. Moreover, we knew, from having used this device in a previous study (17), that, in our long-haired female subjects, electric signals would have likely been lost or of a poor quality. We were unable to check directly the quality of the signals. For these reasons, a too small-sized female population would have been recorded in good conditions, and, to maintain our group of subjects as homogeneous as possible, we decided to discard all of our female subjects from the polysomnography. However, qualitative and quantitative aspects of sleep were evaluated in male and female subjects from sleep logs completed after wake-up from D1 to D10, as used previously (33). Sleep log questions were about bed and wake time, sleep latency (<15 min, 1530 min, 3045 min, >45 min), awakenings and sleep periods (noted on a 24-h scale with a precision of 15 min), sleep quality (light, intermediate, deep), dream quality (pleasant, unpleasant), wake-up quality (very easy to very difficult), and, finally, subjective aspect of sleep duration (sufficient or not).
Daytime sleepiness. Over baseline and recovery periods, sleepiness was assessed in all subjects from EEG recordings by sleep latencies tests (SLT), assuming that sleepiness is a physiological need state that leads to an increased tendency to fall asleep (10). However, our method was not a standardized multiple SLT (10), because sleep latencies were measured with only two naps (at 0900 and 1400). As for a multiple SLT, subjects were instructed to allow themselves to fall asleep or not to resist falling asleep while lying with eyes shut in a quiet, dark room. The recordings were stopped if subjects did not fall asleep within 20 min after the start of the test period (lights off) or after either three consecutive 30-s epochs of stage 1 sleep, one first 30-s epoch of stage 2 sleep, or REM sleep.
Continuous wrist actigraphy was also employed to evaluate sleepiness objectively (21, 22, 27). Subjects wore a piezoelectric accelerometer (Gaehwiler Electronic, sensitivity: 0.1 G, sampling rate: 8 Hz, band-pass filter: 0.253 Hz, data-acquisition period: 15 s) on their nondominant wrist throughout the experiment. The number of movements with a force >0.1 G was counted and then was averaged over the following periods: 07000900, 09001200 (morning test period), 12001400, 14001700 (afternoon test period), 17001900, 19002300, 23000300, and 03000700.
Sleepiness was subjectively evaluated by the "sleepy-awake" item from Bond and Lader's (7) visual analog scales (VAS) during baseline and recovery periods and also during the flight, 1, 3, and 5 h after drug intake (1600).
Except for continuous actigraphy, these objective and subjective measurements were taken at 0900 and 1400, corresponding to the hyper- and hypovigilance periods defined by Lavie (19).
Oral temperature. To check the synchronization of our subjects before the flight in the USA and their resynchronization in France as well, oral temperature was measured at 2-h intervals between 0700 (wake up) and 2300 (bedtime), by using an electronic thermometer.
Statistical Analysis
Sleep and sleepiness data were analyzed separately and compared by two-way ANOVA (drug: SRC, Mlt, Pbo; period of time: recovery vs. baseline) with repeated measurements over time. The level of significance (P) was set at 0.05. In case of interaction between drug and time (night or day), drug and time effects were analyzed, respectively, across time and for each treatment, by using a Newman-Keuls test.
| RESULTS |
|---|
|
|
|---|
Baseline sleep. Because analysis of the baseline polysomnographic recordings did not reveal any first-night effect, the subjects were allocated at random into three groups (SRC, Mlt, and Pbo, see METHODS). There were no significant differences in sleep parameters among the subjects of these three groups (Table 1).
|
Recovery sleep. See Table 1. When data measured during recovery from standard deviation within each drug group are compared, no subject slept longer than on baseline night (N-1). TST, SPT, and WASO did not change significantly throughout the experiment in all groups, except for SPT, which fell by
30 min in the SRC group on N4 (P < 0.05). However, compared with baseline, SRC subjects increased their WASO by
40 and 20 min on N3 and N4, respectively, and then dropped
40 min in N5, although these changes did not reach significance. Because TST and time in bed were constant for all subjects, sleep efficiency index did not vary throughout recovery in any of the groups.
Compared with baseline, sleep latency, non-REM, and REM sleep measured during recovery depended on treatment.
For sleep latency (SOL, Fig. 3), Pbo subjects fell asleep earlier on N1 (SOL: -8 min, P < 0.05), but they fell asleep later on N4, N5, and N6 (SOL: +18, +30, and +28 min, respectively; P < 0.05). SOL of SRC subjects was not shortened on N1, but it was lengthened at the end of the treatment (N4: +29 min, P < 0.05; N5: +11 min, P < 0.05). By contrast, SOL of Mlt subjects did not change throughout the recovery period.
|
For non-REM sleep, compared with baseline, SWS (Fig. 4) was longer in subjects receiving Pbo and to a lesser degree in those receiving Mlt on N1 (Pbo: +53 min, Mlt: +33 min, P < 0.05), N2 (Pbo: +69 min, Mlt: +28 min, P < 0.05), and N5 for Pbo subjects only (+37 min, P < 0.05). SWS also appeared significantly earlier (SWS latency decreased) in all of these subjects on these nights. This rebound in SWS was observed at the expense of stage 2, which decreased in Pbo subjects on N2, N3, and N5 by 86, 65, and 44 min, respectively (P < 0.05), and also decreased under Mlt on N1, N2, and N4 (-18, -20, and -31 min, respectively; P < 0.05). In contrast, in the subjects receiving SRC, SWS did not occur earlier (it was even delayed in N4 by 17 min, P < 0.05), and the rebound in SWS was postponed to N6, the night after the end of drug administration (SWS: plus
21 min, P < 0.05).
|
REM sleep (Fig. 5) decreased by 29 min in Pbo subjects on N1 (P < 0.05) and by 24, 15, and 25 min under Mlt on N1, N2, and N3, respectively (P < 0.05). The expected rebound in REM sleep was observed on N2 in Pbo subjects only (+22 min, P < 0.05); it also came earlier than in baseline conditions (REM sleep latency: -49 min; P < 0.05). By contrast, no modification of REM sleep was observed under SRC throughout the recovery period.
|
We observed only a few significant differences between drug conditions within each night. On N1, compared with Pbo, stage 1 was increased under SRC (+8 min, P < 0.05) and decreased under Mlt (-8 min, P < 0.05). Stage 2 under Mlt was longer than in the other subjects on N3 (P < 0.05). The rebound of SWS on N2 was shorter in Mlt than in Pbo subjects (P < 0.05).
Subjective aspects of sleep. Sleep logs also identified few differences between the drug groups on any given night. We observed, on N1, that SRC subjects woke up earlier, slept less long, and complained of more awakenings than did the Mlt group (P < 0.05), whereas Mlt subjects fell asleep earlier and slept longer than did the Pbo group (P < 0.05). Wake up of the SRC group was more difficult than for the Pbo group on N5 (P < 0.05), and sleep under SRC was longer and better than in the Mlt group on N6 (P < 0.05).
Comparisons between recovery nights with baseline data within each drug group did not show the differences observed with the EEG recordings. In Pbo subjects, TST was decreased on N4 (P = 0.031). Under SRC, TST was also decreased on N4 (P = 0.039), but increased on N6 (P = 0.027) at the end of the treatment, whereas the quantity of sleep and the quality of dreams and wake up seemed to be insufficient or impaired on N2 (P = 0.011), N3 (P = 0.029), and N5 (P = 0.034). Under Mlt, TST appeared shorter on N1 (P = 0.022), quality of sleep better on N1 and N2 (P = 0.013 and 0.034, respectively), quality of dreams worse on N3 (P = 0.022), with a lower duration of sleep on N2 (P = 0.034), and higher quality of wake up on N2 (P = 0.034).
Daytime Sleepiness
Neither objective nor subjective measurements of sleepiness showed any significant gender effect.
Objective measures of sleepiness. SLT over baseline and recovery periods are shown in Fig. 6.
|
Compared with baseline, Pbo subjects were significantly drowsier until D6 (P < 0.05 to 0.0001, according to the recovery day) and also at D9 AM (P < 0.01) and D10 PM (P < 0.05).
Conversely, SRC subjects were not sleepy during the period that the drug was given (D1D5), except on D1 and D2 PM, when sleep latencies were reduced (P < 0.05). However, sleep latencies were higher under SRC than under Pbo on D1 PM (424 ± 114 vs. 74 ± 17 s; P < 0.05) and D2 AM (736 ± 155 vs. 272 ± 50 s; P < 0.05). This stimulating effect, compared with Pbo, tended to be maintained until D6 (not significant). Thereafter, compared with baseline, SRC subjects were sleepier from D6, i.e., at the end of the treatment (P < 0.05 to 0.001, depending on the day).
Under Mlt, the subjects were sleepier (sleep latencies significantly decreased, P < 0.001 to 0.05) than in the baseline condition over the entire recovery period during which the drug was taken (D1D3). Subsequently, sleep latencies did not differ from baseline on D4D5, decreased again until D8 AM (P < 0.01 to 0.05), and returned to baseline level until D10 AM.
Wrist actigraphic measures reflected normal daytime and nighttime profiles, in accordance with the time table of the experiment (rest and test periods) in all subjects throughout the study (Fig. 7). There was no significant difference in wrist activity between drug conditions within each recovery day. Comparisons between recovery and baseline did not show any difference for Pbo and Mlt subjects, but, with SRC, overall daytime activity was higher (P < 0.05) from D1 to D5, i.e., over the entire recovery period that SRC was taken. Otherwise, nighttime activity was not altered with SRC, which, as indicated by the EEG measurements, also showed that sleep was not fragmented under SRC.
|
Subjective measures of sleepiness. There was no significant difference among the three drug groups regarding the awake/sleepy item on Bond and Lader's VAS (7), except on D1 AM, when SRC subjects were sleepier than the Mlt group (Fig. 8).
|
VAS confirmed the sleepiness shown by SLT in Pbo subjects on D1 AM and PM only (P < 0.05 and P < 0.01, respectively), but not for the remaining recovery period, during which subjects felt more awake on D2 AM, D5 PM, D6 AM, and D8 AM, compared with baseline (P < 0.05). SRC subjects felt sleepier in D1 AM only (P < 0.0001), but were less sleepy in the afternoon of D3 (P < 0.05), D4 and D8 (P < 0.01), and D9 and D10 (P < 0.001). Under Mlt, subjects felt sleepier only on D1 PM (P < 0.001), but not on D2 and D3 as shown by SLT.
No significant differences were observed among the three drug groups within each day of the study, except for the Mlt subjects who felt less sleepy during the flight (P < 0.05) than the two other groups of subjects who had not taken any active drug (they included the SRC subjects whose treatment began on the morning of D1). Mlt subjects were also less sleepy than SRC subjects on D1 AM (P < 0.05).
Oral Temperature
All subjects were synchronized in the USA (the trough of temperature was at 0700, and the peak occurred between 1700 and 1900) and were obviously desynchronized after the flight (trough at 1100 and peak at 2100, local time). Basically, resynchronization of temperature is defined as an advance of the trough (batyphase) and the peak (acrophase) of the rhythm. While the peak of temperature occurred at changeable times all over the recovery, we observed that the reentrainment of the trough began from D5 in Pbo subjects but still remained partial the last day of the study (trough at 0900), whereas it was complete from D2 in Mlt subjects (trough at 0700) and began from D3 to the end of the treatment in SRC subjects. Thus the resynchronization of oral temperature seemed to be faster under Mlt and to a less degree under SRC than with Pbo, at least for the batyphase of the rhythm of temperature.
| DISCUSSION |
|---|
|
|
|---|
We did not observe any sleep disturbances during the baseline night, indicating absence of a first-night effect (1). This was expected as our subjects spent 5 days and nights in Texas for synchronization before the day and night baseline period began. The sleep measures were in agreement with literature data for the range of ages of the subjects (12).
Our subjects experienced the deleterious effects of jet lag combined with sleep deprivation. The sleep architecture of Pbo subjects was disturbed during the first recovery night, with a greater duration of SWS at the expense of REM sleep (14). Indeed, REM sleep tends to be predominant at the end of the night, but, due to a phase advance of sleep rhythms, our Pbo subjects woke up before getting the full amount of REM sleep. Hence, Pbo subjects were sleepy during the first recovery daytime, in accordance with data from previous studies (35).
The SWS and REM sleep debt mounted during the flight and the first recovery day but was totally reestablished after the 3 following nights, so that overall sleep architecture was normalized from the fifth recovery day with an absence of sleepiness after D6, as shown by SLT. This is consistent with the mean reentrainment shift rate for the sleep-wake cycle, which is
1 h/day after an eastbound flight (5), or 7 days for a 7-h eastbound flight as in our study. The Pbo subjects also demonstrated that the resynchronization of rhythms on D5 was complete for Mlt and partial for cortisol (25) and central temperature, in accordance with previous data (13, 15).
We used 5 mg Mlt per dose in accordance with the protocol for alleviating jet lag proposed by Arendt et al. (4): when going east, intake of one 5-mg capsule of Mlt on the departure day and, if necessary, on the flight, at 1800 local time, and on arrival at local bedtime (22002300) for 4 days. In any case, a dose >5 mg (10 mg daily) would not have been fully cleared from the circulation after an 8-h sleep (11) and a lower dose would have been less effective in alleviating jet lag-related sleep disorders (32).
In our study, Mlt improved subjective measures of sleep and sleepiness, in accordance with literature data (3). Self-reports showed that our Mlt subjects fell asleep earlier and slept longer than did our Pbo subjects. Looking at objective sleep measurements, it has been reported that Mlt shortened SOL and SWS duration (37), without modifying REM sleep duration but sometimes lengthening it (8). By contrast, in our Mlt subjects, SOL was not shortened, and SWS was increased at the expense of REM sleep. This discrepancy could be explained, in part, by the high individual variability in the pharmacokinetics of Mlt, which may give rise to marked differences in sensitivity (2). Moreover, the hypnotic effects of Mlt on the sleep EEG are short lived, even though Mlt levels are high at the time of sleep onset (9). Sleep onset is known to take place during the descending phase of temperature after acrophase occurred. In our Mlt subjects as in the other groups, the acrophase of the temperature rhythm was not clearly reentrained, which may also explain why SOL was not shortened. Last, our subjects were somewhat sleep deprived for
33 h (time between the end of the last baseline night and the beginning of the first recovery night), as we prohibited them from sleeping during the flight. As for our Pbo subjects, there was a significant sleep debt, which may account for the fact that, despite the intake of Mlt, SWS increased during the first 2 recovery nights, resulting in a decrease in REM sleep. In fact, under jet lag conditions, there is little evidence for a phase-shifting action of Mlt on objective markers of human circadian rhythms (28) such as sleep. SLT showed that our Mlt subjects were sleepy until the last intake of Mlt (D3), whereas VAS showed that they were sleepy up to D1.
In contrast to literature data (32), Mlt failed to decrease sleepiness in our subjects. It should be borne in mind that Mlt improves vigilance and alertness after jet lag in non-sleep-deprived subjects. In our subjects, the sleepiness may have stemmed more from the sleep deprivation than a residual hypnotic effect of Mlt, as saliva and thus plasma levels of Mlt of our Mlt subjects were comparable to those of the SRC and Pbo subjects (30 pg/ml in saliva, measured at 0700) (25).
The alerting effect of SRC was particularly evident as the subjects could sleep for the 7 h 30 min allotted sleep time and so were not sleep deprived (20). Nevertheless, this alerting effect was not observed on the morning of the first recovery day, when sleep latencies and the feeling of sleepiness were higher than in baseline conditions, although motor activity was maintained. This could be accounted for by the kinetics of SRC (Fig. 1): the minimal efficacy level of caffeine was probably not reached at SLT time (0900), 1 h after SRC intake. As soon as the treatment was stopped, subjects were as sleepy as in the baseline condition, consistent with the fact that the subjective (VAS) and objective (SLT) efficacy of 300 mg SRC is lost 913 h after intake.
The alerting effect of SRC seemed to induce some residual effects on recovery sleep, indicated by less SWS rebound in N1N2 and increased nighttime wakefulness in N1 (plus
25 min; not significant) compared with Pbo and Mlt subjects. Moreover, sleep logs showed that SRC subjects woke up earlier, slept less, and complained of more awakenings than did the Mlt group during N1. In addition, the rebound in SWS was postponed to N6 at the beginning of SRC withdrawal, whereas WASO fell on N5, the night after last intake (D5, see Fig. 2) and continued to be low until the end of the study. These observations suggest that subjects were sleep deprived under SRC. Caffeine levels in saliva samples were measured three times per day (0700, 1200, 2200) throughout the study (25). At 2200, i.e., 14 h after intake, salivary SRC was 2 µg/ml, corresponding to a plasma level of 2.7 µg/ml, based on a saliva-to-plasma ratio of 0.74 (30). This level was higher than the plasma level of caffeine effectiveness (2.5 µg/ml, see Fig. 1) and may possibly explain the disturbances of sleep in the recovery period.
| CONCLUSION |
|---|
|
|
|---|
| ACKNOWLEDGMENTS |
|---|
|
|
|---|
GRANTS
This study was supported by Nestec S.A., Lausanne, Switzerland.
| FOOTNOTES |
|---|
The costs of publication of this article were defrayed in part by the payment of page charges. The article must therefore be hereby marked "advertisement" in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.
| REFERENCES |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
P. C. Zee Circadian Rhythm Sleep Disorders ACCP Sleep Med Brd Rev, January 1, 2009; 4(0): 63 - 76. [Full Text] [PDF] |
||||
![]() |
N. Buscemi, B. Vandermeer, N. Hooton, R. Pandya, L. Tjosvold, L. Hartling, S. Vohra, T. P Klassen, and G. Baker Efficacy and safety of exogenous melatonin for secondary sleep disorders and sleep disorders accompanying sleep restriction: meta-analysis BMJ, February 18, 2006; 332(7538): 385 - 393. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| Visit Other APS Journals Online |