1Department of Vascular Surgery, Academic Medical Center, University of Amsterdam, 1100 DE Amsterdam; 2Department of Anesthesiology and Intensive Care, St. Antonius Hospital, 3430 EM Nieuwegein; and 3Department of Surgery, University Hospital Maastricht, University of Maastricht, 6202 AZ Maastricht, The Netherlands
Submitted 27 February 2003 ; accepted in final form 23 June 2003
| ABSTRACT |
|---|
|
|
|---|
microcirculation; capillaries; blood pressure; regional blood flow; vasoconstriction
Thus far the regulation of capillary blood pressure has been investigated in healthy and diseased subjects in the capillaries of the fingernail fold only, using a direct cannulation and a servo-nulling micropressure system (17). This direct method appeared to be a reliable technique to give valuable information about the (patho)physiology of microcirculatory perfusion (4, 23). Shore et al. (25) demonstrated that elevation of systemic blood pressure through exercise did not change capillary pressure in the hand and suggested that protective mechanisms minimize the transmission of changes in systemic blood pressure to the capillary bed, whereas an increase in venous pressure in the arm gave a pronounced rise in capillary pressure (18).
The regulation of capillary pressure in the foot is likely to be much more robust than in the hand to counteract the considerable changes in arterial and venous pressure on a change in posture. On the other hand, various diseases (arterial and venous insufficiency, diabetic microangiopathy, etc.) mainly affect, or are more pronounced in, the microcirculation of the foot (2, 22, 30). The regulatory mechanisms of capillary pressure in the foot have been investigated by Levick and Michel (14) by using a direct, static capillary pressure measurement technique. They showed that capillary pressure can rise up to 100 mmHg in standing position and that in the dependent extremity there is a tight control of capillary pressure probably by arteriolar vasoconstriction. Furthermore, they showed that capillary pressure approaches venous pressure in the dependent position (14). However, this work was performed only in two volunteers with a static measurement system and has never been confirmed by others. Jünger and colleagues (13, 28) have described the investigation of the capillary pressure in the foot in patients with venous insufficiency by using a dynamic micropressure system. Dynamic measurements allow for additional analysis of the capillary pulse pressure and capillary pressure waveform during the cardiac cycle and yield information about precapillary resistance (18, 26).
Knowledge about the regulation of the precapillary resistance in the foot may increase our understanding of the edema formation in patients suspected of capillary hypertension, e.g., venous insufficiency and diabetes mellitus, and the reappearance of postural vasoconstriction in the foot, e.g., after revascularization procedures that increase peripheral blood pressure. However, the (patho)physiological knowledge of capillary pressure regulation in health and disease is mainly derived from investigations performed in the fingers (21, 2426). Therefore, in this study we investigated the effect of postural changes on capillary pressure and perfusion and in the hallux in healthy subjects by means of capillary microscopy, laser Doppler fluxmetry (LDF), and a servo-nulling micropressure system.
| SUBJECTS AND METHODS |
|---|
|
|
|---|
Dynamic intracapillary blood pressure measurements were performed in the eponychium of the hallux of the left foot in the sitting and supine positions. LDF (PF 407, Periflux 4001, Perimed, Stockholm, Sweden; filter time 0.03 s) of the adjacent area, continuous blood pressure of the second toe (Finapres BP Monitor 2300, Ohmeda, Louisville, CO), and ECG were assessed simultaneously, to validate the capillary pressure. The laser Doppler was used to investigate total cutaneous perfusion (29), whereas the capillary red blood cell velocity was assessed to evaluate nutritive perfusion. Skin temperature of the toe (monitor 78342A, Hewlett-Packard, Amstelveen, The Netherlands) was monitored to evaluate a possible variability due to temperature changes (8, 14). All synchronous measurements (ECG, laser Doppler, temperature, capillary pressure, and continuous toe pressure) were sampled on-line and analyzed off-line by means of a data-acquisition and analysis system (AcqKnowledge III and MP 100WSW, Biopac System, Santa Barbara, CA). After this experiment, the brachial (Dinamap Plus; Criticon, Tampa, FL) and ankle pressures (highest of dorsal pedal artery and posterior tibial arteries at the level of the ankle) were measured with an 8-MHz Doppler probe (PV lab, Stöpler, Electric Diagnostic Instruments, Burbank, CA) and a cuff (12-cm width) just above the ankle. The toe pressure was measured on the hallux of the same foot as the capillary pressure by means of photoplethysmography (PV lab, Stöpler, Electric Diagnostic Instruments) and a digital cuff with a width depending on the diameter of the toe. A cuff width closest to 120% of the diameter of the hallux was chosen (cuff 1.5, 2.5, or 3.3 cm, Hokanson, Bellevue, WA) (5). The reproducibility of the brachial, ankle, and toe blood pressure measurements in our laboratory has been evaluated recently and appeared to be "good" (5). The reproducibility of the laser Doppler has been investigated previously by Lukkari-Rautiarinen et al. (16)
Additionally, peripheral venous blood pressure was measured in the great saphenous vein at the foot by means of a 22-gauge Venflon connected to a pressure transducer (monitor 78342A, Hewlett-Packard) in eight subjects in the same positions in which the capillary pressure measurements were performed.
Intravital capillary microscopy. The capillaries of the hallux nail fold were visualized by means of a capillary microscope with motor focusing in combination with a video circuitry as described before (4, 30). Capillaries were punctured while visualized by use of a x10 objective (PL Fluotar, 10/0.30 Leitz, Wetzlar, Germany) and a digital camera (Tm-6CN Pulnix America, Sunnyvale, CA), giving a total magnification on a monitor (PM 931, Ikegami, Maywood, NJ) of
x310 (screen 180 x 136 mm = 0.58 x 0.44 mm skin area). The images were stored on videotape for off-line analysis afterward. Capillary diameter (in µm), capillary density (in mm2), and capillary red blood cell velocity (RBCV; in µm/s) during the capillary pressure measurement were assessed as described before (Cap-Image software, Zeintl, Biomedical Engineering, Heidelberg, Germany) (4, 32).
Capillary pressure. Capillary pressure was measured by a direct servo-nulling method. The principles of the measurement technique, circuit description, and calibration have been evaluated and described in detail before for the fingers but are essentially the same for the measurements in the toes (4). In short, the capillary loops were punctured in the apex with micropipettes (tip diameter varying between 3 and 4 µm), filled with a 2 M NaCl solution (with 10E/ml heparin to prevent plugging), connected to the servo-nulling micropressure system (900A World Precision Instruments, Sarasota, FL). The apparatus contains an electrical circuit and an air circuit, which regulates the pressure inside the pipette so that it equals the pressure outside the tip. The electrical circuit is formed by a Wein bridge oscillator, which generates a 1,000-Hz (sinusoidal voltage) constant carrier current through the microelectrode. An influx of blood into the capillary would change the impedance of the pipette. A pressure control driver will automatically adjust the microelectrode tip impedance to a change in pressure outside the tip of the pipette (4, 6).
The cuticle and upper layer of the stratum corneum of the epidermis were removed to facilitate puncturing of the capillaries. The position of the tip of the pipette was adjusted so that flow through the capillary was visually unobstructed and a synchronous waveform was received (Fig. 1). A measurement was regarded valid when the capillary pulse pressure waves were in phase with the waveforms of the ECG, toe pressure, and laser Doppler while capillary flow was unobstructed for at least 5 s. The mean systolic, diastolic, and mean pressures were derived from the valid interval. The reproducibility of the capillary pressure measurement in two capillaries in the same digit was evaluated in fingers. The reproducibility using the present setup was expressed as the standard deviation of the difference between two paired measurements (n = 10) and was found to be small: 2.8 mmHg.
|
Furthermore, the capillary pulse pressure amplitude (CPPA), which can be used as a measure of the precapillary resistance, and the toe pulse pressure amplitude (TPPA) was defined as the pressure difference between the diastolic and systolic values (18). After the investigation, any remaining shards were removed by wiping with a paper tissue, and the puncture area was disinfected.
Statistics. The results are expressed in means with standard deviations after testing for skewness. Statistical analysis of possible differences between the sitting and supine positions in all measurements was evaluated by using the paired t-test. Power analysis revealed that 13 patients are required to refute the null hypotheses that the mean sitting and supine capillary pressures were not the same (minimum difference 8 mmHg, SD = 8 mmHg, power 0.8, and P < 0.05; two-sided, paired analyses). With 13 volunteers, the minimal size of differences that could be detected (to exclude type 2 errors) was, for ankle pressure, 7 mmHg; for toe pressure, 16 mmHg; for the mean toe pressure by Finapres, 15 mmHg; for capillary density, 11; for RBCV, 0.04 mm/s; for capillary diameter, 2 µm; for temperature, 2°C; and for LDF, 0.16 V.
| RESULTS |
|---|
|
|
|---|
|
Capillary pressure in the sitting position was significantly higher than in the supine position (see Table 1 and Fig. 3). The same was true for the toe, ankle, and venous pressures, whereas brachial pressures and skin temperature did not change significantly during the investigation. However, the rise in systolic capillary pressure (mean 32 mmHg) was significantly (P = 0.001) less than the rise in systolic ankle and toe pressures (both mean 57 mmHg, see Table 1) but less than the rise in venous pressure (mean 41 mmHg). There was a significant difference between the arterialcapillary blood pressure fall between supine and sitting position (56 and 81 mmHg, respectively). Capillary systolic pressure rose to up to 100 mmHg in the sitting position. However, the remaining microcirculatory parameters (CPPA, capillary density, RBCV, capillary diameter, LDF) did not change significantly on the change in posture, indicating that capillary volume flow and total skin flow did not alter substantially by the change in posture (Table 1).
|
|
| DISCUSSION |
|---|
|
|
|---|
In this study, systolic capillary pressure in the toe during sitting was found to be rather high (70 up to 100 mmHg), which is much higher than commonly known (19). Our results correspond with the static capillary pressure measurements using a manometric technique as performed by Levick and Michel (14), who found a capillary pressure of 67 mmHg when the hydrostatic pressure difference between heart and capillary was 80 mmHg and pressures up to 100 mmHg in the standing position. This increased pressure in the sitting position considerably influences the forces governing fluid movement across the capillary wall, because the capillary pressure is a crucial factor in this process and is bound to lead to interstitial edema formation. The fluid exchange across the capillary membrane of a single, short section of a capillary, as initially proposed by Starling (27), is dependent on the transmural pressure gradient (15, 19). An increase in hydrostatic pressure causes extravascular fluid accumulation and edema formation. This process is linearly related to the ortho- or hydrostatic pressure. An increase in mean capillary pressure from 32 to 63 mmHg theoretically increases the fluid passage across the capillary wall (fluid filtration rate rises from 0.1 to
0.4 µm2/µm3) (19). Under physiological situations, the orthostatic venous pressure is reduced by the calf muscle pump (12). This in turn might lower the capillary pressure and seems to be an essential factor in the prevention of edema formation, provided the venous valves are sufficient. Unfortunately, the effect of the calf muscle pump could not be evaluated in our setup, because even an isometric contraction of the calf muscle may cause movement artifacts that break the tip of the pipette.
The height difference between heart and toe was 79 cm, causing an orthostatic pressure equal to 58 mmHg, which corresponds with the increase in ankle and toe blood pressures (59 mmHg). Ubbink et al. (32) studied the effect of posture on skin capillary perfusion in the foot and concluded that postcapillary pressure appears to be an important factor in the regulation of capillary perfusion, because an increase in venous resistance mimics the effects of leg dependency. Previous investigations showed that microcirculatory perfusion in the foot changes on a change in posture, i.e., a reduced RBCF (20, 32), resulting in a decreased LDF (7, 30, 33) probably caused by arteriolar vasoconstriction. Surprisingly, these observations could not be confirmed in the present study. This may be explained by the difference in time frame between the postural change and measurement. Some suggest that the postural vasoconstriction mechanism is short-lived and flow returns to normal after a while. Usually the RBCV and LDF are directly measured in the sitting position after a stabilization period of a few minutes (9, 32), whereas the measurements in this study were performed after at least half an hour because of the preparation time needed and the difficulties of procedure. This might have reduced the magnitude of the response. However, the activation of a postural vasoconstriction response was obvious in our study because of the fact that CPPA was unaltered despite the increase in TPPA on dependency.
The present study showed direct evidence for arteriolar vasoconstriction. The pressure fall between artery and capillary increased significantly, whereas flow (RBCV and capillary diameter, and laser Doppler) remained unchanged (Table 1). This suggests that activation of the postural (arteriolar) vasoconstriction response apparently reduces the transmission of the digital arterial pressure to the capillaries (3, 10, 11). This is confirmed by an increase in the pre- to postcapillary resistance ratio [(PaPc)/(PcPv), where Pa, Pc, and Pv are arterial, capillary, and venous partial pressures], reflecting the distribution of resistance in the local circulation (14). We calculated this ratio from the systolic arterial toe, capillary, and venous foot pressures. The ratio in the sitting position (ratio 18) is much higher than in the supine position (ratio 4), which means an increase in precapillary (arteriolar) resistance in the sitting position. This would be in agreement with our hypothesis that arteriolar vasoconstriction mechanisms (probably mainly the venoarteriolar reflex) prevent transmission of the increase in arterial pressure to the capillaries (3, 11). Therefore the present observations indicate that flow regulation outweighs pressure regulation in the microcirculation.
The activation of arteriolar vasoconstriction mechanisms is confirmed by the absence of increase in CPPA. The CPPA is not changed despite the increased TPPA (Table 1). This shows that the pulsatility has been more damped out in the sitting position than in the supine position, indicating a precapillary vasoconstriction.
The mean capillary pressure increased in line with the increase in venous pressure. This is in agreement with previous observations showing that, with incremental elevation of venous pressure, pressure at the capillary apex approaches that in the veins (18, 32). After all, the postcapillary resistance is lower than the precapillary resistance. So changes in venous pressure (posture and breathing) can be easily transmitted to the capillary bed.
In summary, our results indicate that the systolic capillary blood pressure can rise substantially (up to 100 mmHg) on leg dependency but remains lower than the increase in toe systolic pressure. Apparently, activation of the peripheral vasoconstriction responses reduces the transmission of the arteriolar pressure to the capillaries and probably contributes as an edema-preventing factor. This technique seems suitable to provide valuable information about the pathophysiology of microvascular disorders in the foot.
| DISCLOSURES |
|---|
|
|
|---|
| ACKNOWLEDGMENTS |
|---|
|
|
|---|
| FOOTNOTES |
|---|
The costs of publication of this article were defrayed in part by the payment of page charges. The article must therefore be hereby marked "advertisement" in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.
| REFERENCES |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
K. Okazaki, Q. Fu, E. R. Martini, R. Shook, C. Conner, R. Zhang, C. G. Crandall, and B. D. Levine Vasoconstriction during venous congestion: effects of venoarteriolar response, myogenic reflexes, and hemodynamics of changing perfusion pressure Am J Physiol Regulatory Integrative Comp Physiol, November 1, 2005; 289(5): R1354 - R1359. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| Visit Other APS Journals Online |