|
|
||||||||
1 Laboratoire de Physiopathologie Respiratoire, Service de Pneumologie, Groupe Hospitalier Pitié-Salpêtrière, Assistance Publique, Hôpitaux de Paris, 2 Unité Propre de Recherche de l'Enseignement Supérieur EA 2397, Université Pierre et Marie Curie Paris VI, 75013 Paris; and 3 Service de Physiologie Respiratoire et Sportive, Hôpital Charles Nicolle, Centre Hospitalier Universitaire, 76000 Rouen, France
| |
ABSTRACT |
|---|
|
|
|---|
The integrity of the central efferent motor pathways to the diaphragm can be assessed by using transcranial magnetic stimulation to measure the latency of the corresponding motor evoked potentials with surface electrodes. Because transcranial magnetic stimulation does not activate the diaphragm alone, signal contamination is a potential problem. To evaluate this issue, surface diaphragmatic motor-evoked potential latencies were compared with latencies recorded from diaphragm needle in 9 healthy volunteers. Surface latencies of muscles likely to contaminate the diaphragm signals (serratus anterior, pectoralis major, and tranversus abdominis) were also recorded. The latencies in response to nonfocal transcranial stimulation from surface electrodes were not significantly different from the needle ones (17 ± 1.3 vs. 17.2 ± 1.1 ms, respectively) but were significantly different from the latencies of the other muscles. In two cases, signal contamination appeared likely (serratus anterior in 1 case, abdominal muscles in 1 case). It is possible to reliably measure the latency of the diaphragm response to transcranial magnetic stimulation with adequately positioned surface electrodes.
cerebral cortex
| |
INTRODUCTION |
|---|
|
|
|---|
TRANSCRANIAL MAGNETIC STIMULATION provides a noninvasive and nonvolitional means to study the corticodiaphragmatic pathway in conscious humans (10, 19, 20, 25, 28, 35). In disease, this technique can identify the central origin of a diaphragmatic dysfunction, for example during stroke (8, 24), multiple sclerosis (9), amyotrophic lateral sclerosis (23), or spinal cord injury (12, 27). This technique thus has a major potential for the clinical investigation of the respiratory impact of central nervous system diseases.
The response of the diaphragm to transcranial magnetic stimulation is chiefly studied in terms of the corresponding motor-evoked potentials recorded by surface chest wall electrodes placed over the anatomical landmarks of the diaphragm. Being nonspecific, transcranial stimulation coactivates the diaphragm and several other muscles. The corresponding electrical activity is liable to be detected by "diaphragm" surface electrodes through volume conduction. Such signal contamination, well described with focal phrenic nerve stimulation techniques (16, 17) and cervical magnetic stimulation (15), could limit the use of transcranial magnetic stimulation as a diaphragm tool.
Modification of conventional diaphragm electrode placement [active
electrode in the 5th to 7th intercostal space on the anterior axillary
line, reference electrode either 5-6 cm apart on the relief of an
adjacent rib or extrathoracic (3, 14, 17, 21)] to a lower
and more medial site (Fig. 1) improves
the reliability of surface electrodes to measure phrenic nerve
conduction time (34). The main reason for this finding is
probably that, at this site, electrodes do not directly overlay muscles
frequently coactivated by phrenic stimulation or cervical magnetic
stimulation, such as the pectoralis major, serratus anterior, or
latissimus dorsi. It can be postulated that if contamination from these
muscles does not occur in response to stimulation techniques that can directly and strongly activate them, it should not occur in response to
transcranial stimulation. The pattern of muscle coactivation with
transcranial magnetic stimulation is, however, different from what it
is with cervical magnetic stimulation and theoretically includes
intercostal and abdominal muscles that do lay underneath diaphragm
surface electrodes at the modified recording site described above. The
present study was thus designed after a previous one by Verin et al.
(34) to evaluate, in a distinct set of subjects, how
costimulation of extradiaphragmatic muscles with the diaphragm by
transcranial magnetic stimulation could interfere with the measurement
of the cortex-to-diaphragm conduction time. Because concentric
intramuscular electrodes have a very limited sampling volume and hence
carry a low risk of signal contamination through volume conduction, we
compared surface recordings performed at a site optimized to record
phrenic nerve stimulation-induced diaphragm contractions with
concomitant recordings obtained from needles inserted in the diaphragm
and with recordings of possibly "contaminant" muscles (serratus
anterior, latissimus dorsi, and pectoralis major surface electrodes,
and abdominal muscles surface and needle electrodes).
|
| |
MATERIAL AND METHODS |
|---|
|
|
|---|
Subjects
After successful completion of the French legal procedure for biomedical research in human volunteers, nine subjects participated in the study (6 men, 3 women; age 24-39 yr; height 159-192 cm; weight 48-96 kg). They were informed in detail of the purpose of the study and methods used and gave written consent. They were studied while sitting on a chair with headrests, abdomen unbound. In each subject, the recordings were obtained from the handedness side.Measurements
Abdominal displacements. Changes in abdominal circumference were monitored with a mechanical strain gauge (Nihon Kohden, Tokyo, Japan) attached to an elastic belt placed at the level of the umbilicus.
Electromyograms. Surface recordings were obtained at four locations [lower chest (Sant); posterior (Spost), upper chest (Ssup), and abdominal wall (Sinf)] by using pairs of skin-taped silver cup electrodes filled with conductive paste (Fig. 1). Spost lay directly over the anterior insertions of the latissimus dorsi and serratus anterior. Ssup lay over the muscle mass of the pectoralis major. Sinf aimed at recording the activity from both the obliquus externus and internus muscles, as well as activity of the deeper tranversus abdominis muscle. The contribution of the above muscle groups to the signals recorded by the corresponding electrodes was ascertained by the presence of bursts of electromyographic activity during tonic voluntary contractions.
Intramuscular recordings were obtained by using bipolar concentric needle electrodes (diameter 0.3 mm, length 25 mm, sampling surface 0.03 mm2; Medelec, Old Woking, UK). One needle electrode was placed in the hemidiaphragm (Fig. 1) adjacent to the lower pair of surface electrode (Nant) following the technique described by Bolton et al. (2) and slightly modified. In brief, the needle was inserted in the intercostal space at the upper border of the lower rib and slowly advanced at an upward angle of 45° with continuous auditory and visual monitoring of the signal until the activity from motor units discharging rhythmically with inspiration could be heard and seen. Then the subjects were asked to breathe in slowly but strongly while protruding their abdominal wall. If necessary, the electrode was further advanced so as to record an optimal burst of activity during this predominantly diaphragmatic inspiration. The intradiaphragmatic location of the electrode was checked from electrical phrenic nerve stimulation in the neck. Because, at this site, fibers from the tranversus abdominis muscle can possibly be intermingled with diaphragmatic insertions, the signal recorded by Nant was also checked during voluntary expiratory efforts. Expulsive efforts with the glottis closed were associated with bursts of electromyographic activity, but Nant consistently remained silent during expiratory efforts with the glottis opened. A mild to moderate degree of abdominal muscle activity thus did not result in contamination of the diaphragmatic signal detected by Nant. A second needle electrode was inserted in the abdominal muscles (Ninf), immediately beside the abdominal wall pair of surface electrodes (Fig. 1) and perpendicularly to the skin, and slowly advanced for 2-3 cm. The appropriate placement of Ninf was assessed during voluntary expiratory efforts from functional residual capacity, expulsive maneuvers with the glottis closed, and during voluntary in-drawing of the abdominal wall (4). Of note, at both intramuscular recording sites, the amplitude of the cardiac artifact appeared reduced compared with the corresponding surface site by at least a factor of 3. All signals were fed to a Nihon Kohden Neuropack Sigma electromyograph (Nihon Kohden, Tokyo, Japan), with a 10-kHz sampling rate and a 20 Hz to 5 kHz bandwidth. They were stored on an Apple Macintosh computer for subsequent analysis (PowerLab, AD instruments, Hastings, UK).Stimulations
All the stimulations were carried out by using a Magstim 200 stimulator (Magstim, Whitland, Dyfed, UK) equipped with either a 90-mm circular coil (peak magnetic field 2.5 T) or a double 70-mm figure-eight coil (peak magnetic field 2 T) at the maximal output of the stimulator. Stimulations were delivered at relaxed end-expiration as judged from the abdominal circumference trace, with the glottis closed. For each of the techniques used (Fig. 2), 10 consecutive stimulations were performed.
|
Cervical magnetic stimulation with the 90-mm coil was performed to measure phrenic nerve conduction time (26, 34). Nonfocal transcranial magnetic stimulation was delivered by using the same coil positioned over the vertex in the position that was associated with the most ample motor-evoked potential from Nant. Focal transcranial magnetic stimulation was performed according to the technique described by Maskill et al. (19). In brief, the coil was first centered over a spot located 3 cm lateral and 2 cm anterior of the vertex in the 10- to 20-electroencephalogram electrode placement system, and its position was then optimized according to the amplitude of the motor evoked potential from Nant.
Data Analysis
Terminology. The peripheral motor responses to cervical magnetic stimulation and the motor potentials evoked by transcranial magnetic stimulation were analyzed in terms of their latency, which was defined as the time elapsed from the stimulus to the first departure of the signal from baseline. Individual values were obtained from averaging seven to nine accepted stimulations (see Quality criteria). The results below are the mean values ± SD, with indication of the range in brackets.
Quality criteria. Peripheral motor responses and motor evoked potentials were retained for analysis when they met the following three criteria: 1) absence of obvious electrical interference, attested to by a clear return of the electromyographic signal to baseline after the stimulus artifact and before the muscle response; 2) absence of contamination by electrocardiographic complexes; and 3) concomitance with clear abdominal expansion, taken as the mechanical witness of a diaphragm response.
Statistics.
Statistical analysis was performed by using the StatView 5.0 software
(SAS Institute, Cary, NC) on an Apple Macintosh computer. Latencies of
the motor-evoked potentials recorded at the various sites were compared
by using a nonparametric Friedman analysis of variance followed by the
Wilcoxon rank test. Differences were considered significant when the
probability of a type I error was
0.05.
Contamination. Contamination of the signal recorded at Sant from rib cage muscle was considered present if, in two or more of the stimulations retained for analysis, 1) the latency of the Sant motor-evoked potential was shorter than the Nant one by >0.75 ms [a conservative value since needle electrodes can provide latencies longer than their surface counterparts by up to 2 ms (7, 18)]; 2) the Sant latency was closer to the Ssup or Spost latencies than to the Nant one. Conversely, contamination from abdominal muscle was considered present if the latency of the Sant motor-evoked potential was longer than the Nant one and closer to the Sinf latency than to the Nant latency.
Additional Studies in Patients
In addition to the above protocol in healthy volunteers, we report and use the results of transcranial magnetic stimulation performed for clinical purpose in 1) five patients with unilateral phrenic nerve paralysis, defined as an abolished electromyographic response to cervical magnetic stimulation (neuralgic amyotrophy, n = 1; brachial plexus avulsion extended to C4, n = 2; complication of cardiac surgery, n = 1; idiopathic, n = 1); 2) four patients with bilateral phrenic nerve paralysis, defined as an abolished electromyographic response to cervical magnetic stimulation on both sides. In these patients, only a Sant signal was obtained. Only nonfocal stimulation was performed.| |
RESULTS |
|---|
|
|
|---|
Cervical Magnetic Stimulation
The latency of the motor response recorded at Sant was 5.4 ± 0.8 ms (4.3-6.5 ms), consistent with usual values in our laboratory (26, 34). The latencies of the motor responses recorded at Ssup and Spost were 3.7 ± 1.1 (2-5.6 ms) and 4.1 ± 0.4 ms (3.5-4.7 ms), respectively, and were consistently shorter than the latency recorded at Sant (P = 0.01 and P = 0.008, respectively). The latency of the motor response recorder by the intramuscular electrode Nant was 5.9 ± 0.8 ms (5-6.7 ms) (P = 0.008 with Sant).Nonfocal Transcranial Magnetic Stimulation
The average latency of the motor-evoked potential recorded at Sant was 17 ± 1.3 ms (15.6-19.1 ms), similar to data obtained in our laboratory with the same technique (28). The latencies of the motor-evoked potentials recorded at Ssup (8 subjects) and at Spost (all subjects) were consistently shorter than the latencies recorded at the other sites [12.4 ± 1.8 ms (10.1-15.7 ms) and 13.8 ± 1.5 ms (11.5-15.9 ms), respectively; P = 0.01 with Sant]. The latencies of the motor-evoked potentials recorded by the abdominal surface electrodes Sinf (7 subjects) were longer [19.1 ± 1.9 ms (15.6-20.4 ms)] than the latencies recorded at the other sites (P = 0.03 with Sant).The average latency of the motor-evoked potential recorded by the lower chest needle electrode Nant was 17.2 ± 1.1 ms (15.7-18.7 ms). It was significantly shorter than the latency of the motor-evoked potential recorded at the abdominal needle electrode Ninf [19.7 ± 1.4 ms (17.2-21.5 ms); P = 0.02].
The latencies of the motor-evoked potentials recorded at Sant tended to be slightly shorter than the latencies measured from the corresponding needle electrode Nant. Similarly, the latencies of the motor-evoked potentials recorded by the abdominal surface electrodes Sinf tended to be slightly shorter than the latencies measured from the corresponding needle electrode Ninf, but these differences did not reach statistical significance.
Focal Transcranial Magnetic Stimulation
Focal transcranial magnetic stimulation elicited a motor-evoked potential at Sant in seven subjects [16 ± 1 ms (14.3-16.8 ms)], whereas no response could be recorded at this site in two subjects. A motor-evoked potential was simultaneously recorded at Spost in five cases [12.5 ± 0.8 ms (10.1-14.9 ms)], at Ssup in four cases [11.9 ± 2.1 ms (11.7-13.7 ms)], and at Sinf in four cases [19.3 ± 3.4 ms (16.1-24 ms)].Focal transcranial magnetic stimulation elicited a motor-evoked potential at the diaphragm needle electrode Nant in the same seven subjects [16.5 ± 1.3 ms (13.9-17.6 ms)]. Here again, the motor-evoked potential latencies measured at the surface electrodes Sant tended to be slightly shorter than the latencies measured at the corresponding needle electrode Nant, without statistical significance.
Focal transcranial magnetic stimulation elicited a response at Ninf in only five subjects [19.7 ± 2.8 ms (15.9-23.4 ms); P = 0.04 with Nant].
Contamination
Contamination of the signal recorded at Sant by a signal arising from rib cage muscles occurred, according to our convention (see MATERIALS AND METHODS), in two of nine subjects with nonfocal transcranial magnetic stimulation (from upper rib cage muscles in one case and from abdominal muscle in the other case). One case of contamination was observed with focal stimulation. Figure 3 shows the recordings obtained in response to nonfocal transcranial magnetic stimulation in one subject where there was no contamination. Figure 4 shows the comparison between the Nant and the Sant trace in all subjects, also in response to nonfocal stimulation.
|
|
Patients with Phrenic Nerve Paralysis
Among the five patients with unilateral phrenic paralysis, the Sant electrode on the paralyzed side remained silent in response to nonfocal transcranial magnetic stimulation in four cases. In the remaining one, a motor-evoked potential was present, with a 19.2-ms latency that was markedly longer than the latency measured at the nonparalyzed side (16.1 ms). This suggested that the response recorded at the paralyzed side took its origin in the abdominal muscles.Among the four patients with bilateral diaphragm paralysis, the electrode at Sant was silent on both sides in two cases. In the two other ones, a motor-evoked potential could be observed on both sides. However, its latency was always above 20 ms, and it was associated with a decrease in abdominal circumference; both elements suggest again that the response recorded took its origin in the abdominal muscles.
| |
DISCUSSION |
|---|
|
|
|---|
Mostly because of a difficult experimental design, this study concerns a relatively small number of subjects, which certainly limits the extent of the conclusions that can be drawn from it. However, it suggests that surface electrodes placed on the lower chest in such a way as to reliably measure the latency of the motor response of the diaphragm to phrenic nerve stimulation can also give access to a reliable measure of the latency of the diaphragm motor potential evoked by transcranial magnetic stimulation in the majority of cases. This is reassuring regarding the interpretation of studies, published or to come, that rely on the combination of transcranial magnetic stimulation with surface electrodes to diagnose central diaphragm dysfunction.
Comparison with Previous Data
The latencies of the motor evoked potentials recorded at Sant match those previously reported (28). Being obtained without the facilitating effect of an underlying contraction (28), they are expectedly longer than in other studies (6, 10, 35).Signal Contamination
Relevance and reality of the problem. All electrical signals within the body are radiated in all directions from their source. A pair of electromyographic electrodes placed on the skin can thus record signals arising not only from the muscle that lies immediately under it, but, theoretically, from anywhere in the body (cross talk). The degree of cross talk at a given recording site is a matter of the spatial summation of signals that are produced close to the electrodes and of signals that are coming from far away. It involves the initial amplitudes of the contributing signals, which depend on the mass of the corresponding muscles, their activation, and the degree of synchronization of their contracting fibers. Indeed, close-to-synchronous mass action potentials are a major source of cross talk, with the electrocardiographic complex being the best example. Cross talk also involves the initial frequency content of the signals, because a signal will lose power and do more so in the high- than in the low-frequency range in proportion to the distance between its source and the recording electrodes. Reduction of the distance between differentially recorded electrodes reduces signal power and acts as a high-pass filter. It thus decreases the risk of cross talk. Similarly, the orientation of the recording electrodes relative to muscle fiber direction can affect the power spectrum of the recorded signal (30) and, therefore, modify the pattern of cross talk (29).
Transcranial magnetic stimulation is not capable of selectively activating the precise motor cortical area governing the contraction of a given muscle, particularly if the area in question is small. The coactivation of various muscles is thus unavoidable and occurs under the form of close-to-synchronous mass action potentials. This makes cross talk at the level of surface electrodes an obvious risk, either from muscles layered beneath the electrodes or from more distant ones through volume conduction. To use transcranial magnetic stimulation as a tool to study the cortical command of a given muscle, it is thus necessary to reckon with the question of cross talk. This issue does not seem to have been addressed in a systematic manner regarding the diaphragm, although several transcranial magnetic studies have been published. In a comparison of the responses of the diaphragm and of hypothenar muscles to cervical and transcranial magnetic stimulation, Zifko et al. (35) mentioned, in two subjects, the concordance between motor-evoked potentials recorded from a surface diaphragm electrode and from an intramuscular electrode. Conversely, Gea et al. (6) found dissimilarities between the motor-evoked potentials recorded from a diaphragm esophageal electrode and from surface electrodes, and raised signal contamination as a possible explanation for their results. Another explanation of this discrepancy could lie in the fact that esophageal electrodes and surface electrodes record electrical activity arising from different sources, namely the crural and the costal diaphragm, respectively. At this point, it is important to clearly separate two issues. One is the interpretation of the whole motor-evoked potential recorded at Sant as reflecting the activity of the diaphragm, which implies that unwanted signals be insufficiently strong to cause a deflection at the recording site. This is clearly not an easy question to address, and the design of the present study does not allow us to answer it. The second issue, which is specifically addressed by our study, is the interpretation of the latency of the said motor-evoked potential as a reflection of the cortex-to-diapragm conduction time.Possibility to measure a reliable diaphragmatic motor-evoked potential latency. Our study shows that, in normal individuals, this possibility exists in the majority of cases. It is mainly supported by the concordance between the latencies measured at Sant and at the corresponding intramuscular site. This argument relies namely on the main assumption that concentric needle electrodes inserted in the diaphragm at Nant do not pick up close-to-synchronized mass action potentials from the intercostal or abdominal muscles. Several arguments support this contention. The first argument lies in the major reduction in amplitude of the cardiac artifact recorded by the intramuscular electrodes compared with that observed on surface recordings (see MATERIALS AND METHODS). In regard to the intercostal muscles, the absence of electromyographic activity at Nant during voluntary expiration makes a contribution of intercostal muscles to the recorded signal unlikely (2, 32). This does not rule out cross talk due to an intercostal close-to-synchronized mass action potential, but the very existence of such potentials in response to transcranial magnetic stimulation is questionable in view of a probably very small motor cortical representation. The small muscle mass involved sets a limit to the power of the corresponding signal, if any. Of note, the observations made in our patients with unilateral phrenic nerve palsy (absence of response to transcranial magnetic stimulation on the paralyzed side in four of five cases; late response of probable abdominal origin in one case) are reassuring about a putative contribution of intercostal muscles to the signal recorded at the Sant site. In regard to the abdominal muscles as a source of cross talk, the absence of electromyographic activity at Nant during voluntary expiration is again reassuring. However, contrary to what is the case with intercostal muscle, the possibility to evoke a close-to-synchronized mass action potential in abdominal muscles from transcranial stimulation is a certitude (11, 22), and the muscle mass involved can confer a non-negligible power to this signal. The fact that the latencies measured by the abdominal intramuscular electrode Ninf were longer than the latencies measured by the diaphragmatic intramuscular electrode Nant in all but one case suggests that the activation of abdominal muscles follows that of the diaphragm. Hence, abdominal muscle activity should not contribute to the first detectable deflection of the signal measured with surface electrodes over the eighth intercostal space. Here again, the observations made in the four patients with bilateral diaphragm paralysis that we studied are reassuring (absence of response to transcranial magnetic stimulation in two cases; latency of a response of obvious abdominal origin far longer than the expected diaphragm latency in the two others).
The recording technique used is probably important to our results. Indeed, the location chosen for the surface electrode Sant provides maximal proximity to the diaphragm together with maximal distance from interfering upper rib cage muscle, and the small interelectrode distance should reduce the risk of cross talk from distant muscles. We have previously shown that, compared with the traditional diaphragm recording technique, these modifications could suppress contamination from thoracic muscles in response to cervical magnetic stimulation (13, 15, 16, 34). In regard to the abdominal muscles, one additional explanation of the small amount of cross talk between the Sant and Sinf electrode could lie in differences in the relative direction of the muscle fibers respective to the interelectrode axis. Indeed, the fibers of the obliquus internus are oriented upward and midward and those of the transversus abdominis run downward and midward, and are not parallel with the diaphragm fibers. The spatial relationship between the abdominal fibers and the Sant interelectrode axis and between the diaphragm fibers and the Sant interelectrode axis should thus be different. This factor is known to modify the power spectrum of the signal recorded, which in turn can influence its distant transmission.Responses of Extradiaphragmatic Muscles
To our knowledge, the responses to transcranial magnetic stimulation of the serratus anterior and pectoralis major have not been described before. The latencies that we measured at the corresponding recording sites (namely Spost for the latissimus dorsi and serratus anterior, and Ssup for the pectoralis major) appear reasonable in view of the location of the concerned muscles and of published data about neck muscles [6.5 ms with transcranial electrical stimulation (5) and 7 and up to 9.4 ± 0.6 mswith nonfocal stimulation (1) and focal stimulation (33), respectively]. Of note, the latencies of the motor-evoked potentials recorded at Spost and Ssup (13.8 ± 1.5 and 12.4 ± 1.8 ms, respectively) in our subjects are close to the latencies of diaphragm responses facilitated by an underlying contraction (13.5 ms on average in Ref. 35). As a result, the risk of signal contamination interfering with the determination of the latency of diaphragm motor-evoked potentials should increase with diaphragmatic facilitation if it occurs without an identical facilitation at the level of the coactivated muscles. The possibility to obtain a diaphragm response independently of facilitation (28) is thus not only important to keep transcranial magnetic stimulation a nonvolitional test but also to increase the reliability of the derived information.Of note, in our study, the coactivation with the diaphragm of possibly contaminating muscles was inconsistent, particularly with focal transcranial magnetic stimulation. This indicates that it is probably, at times, possible to obtain a pure or close to pure diaphragm motor-evoked potential.
Practical Consequences and Conclusions
From the present observations, we submit that surface electrodes placed in the lowest accessible intercostal space close to the costo-chondral junction and <2 cm apart from one another are appropriate to determine the latency of the response of the diaphragm to transcranial magnetic stimulation in the absence of facilitation, namely under relaxation conditions. Two safeguards to detect possible signal contamination can be proposed. The first consists in checking that the considered potential is actually associated to a diaphragmatic contraction, as attested to by a mechanical indicator such as abdominal expansion. In the absence of such expansion, a motor-evoked potential should not be interpreted in terms of diaphragm response. The second safeguard consists of comparing the response obtained at the diaphragm recording site with that recorded by electrodes to 1) optimally pick up close-to-synchronous potentials arising from the latissimus dorsi and serratus anterior (e.g., 2 electrodes in the 5th to 6th intercostal space, on the posterior axillary line) and 2) record activity from the upper abdominal muscles (e.g., 2 electrodes at the intersection of the midclavicular line and of a horizontal line drawn between the costal margin and the ombilicus). A latency of the motor-evoked potential read at the lower anterior chest site <15 ms and not longer than the latency of the concomitant response at Spost should raise a strong suspicion of signal contamination from rib cage muscles. Similarly, a latency of the motor-evoked potential at Sant of >20 ms and not shorter than the latency of the concomitant response at the abdominal site should raise a strong suspicion of signal contamination from abdominal muscles. In rare occurrences, it is conceivable that an abnormal closeness between the latencies at the diaphragm site and at the abdominal site is due to the conduction delay affecting the path to the diaphragm but leaving intact that to the abdominal site. Study of the effects of inspiratory facilitation on the diaprhagm response should allow the investigator to distinguish this situation from a case of contamination.With this in mind, and the small size of the study acknowledged as a limitation, it should be possible to reliably diagnose and follow up central diaphragmatic dysfunction. However, large scale studies of transcranial magnetic stimulation are needed to better define normal values and to determine the occurence of signal contamination in the relevant population of patients, namely those with suspected central diaphragm abnormalities.
| |
ACKNOWLEDGEMENTS |
|---|
This study was supported by Association pour le Développement et l'Organisation de la Recherche en Pneumologie, Paris, France. Alexandre Demoule was a scholar of Assistance Publique-Hôpitaux de Paris (Médaille de l'Internat), Paris, France.
| |
FOOTNOTES |
|---|
Address for reprint requests and other correspondence: T. Similowski, Laboratoire de Physiopathologie Respiratoire, Service de Pneumologie et de Réanimation, Groupe Hospitalier Pitié-Salpêtrière, 47-83, Bd de l'Hôpital, 75651 Paris Cedex 13, France (E-mail: thomas.similowski{at}psl.ap-hop-paris.fr).
The costs of publication of this article were defrayed in part by the payment of page charges. The article must therefore be hereby marked "advertisement" in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.
First published October 11, 2002;10.1152/japplphysiol.00581.2002
Received 1 July 2002; accepted in final form 28 September 2002.
| |
REFERENCES |
|---|
|
|
|---|
1.
Berardelli, A,
Priori A,
Inghilleri M,
Cruccu G,
Mercuri B,
and
Manfredi M.
Corticobulbar and corticospinal projections to neck muscle motoneurons in man. A functional study with magnetic and electric transcranial brain stimulation.
Exp Brain Res
87:
402-406,
1991.
2.
Bolton, CF,
Grand'Maison F,
Parkes A,
and
Shkrum M.
Needle electromyography of the diaphragm.
Muscle Nerve
15:
678-681,
1992.
3.
Delhez, L.
Modalités, chez l'homme normal,de la réponse électrique des piliers du diaphragme à la stimulation électrique des nerfs phréniques par des chocs uniques.
Arch Int Physiol Biochim Biophys
72:
832-839,
1965.
4.
De Troyer, A,
Estenne M,
Ninane V,
Van Gansbeke D,
and
Gorini M.
Transversus abdominis muscle function in humans.
J Appl Physiol
68:
1010-1016,
1990.
5.
Gandevia, SC,
and
Applegate C.
Activation of neck muscles from the human motor cortex.
Brain
111:
801-813,
1988.
6.
Gea, J,
Espadaler JM,
Guiu R,
Aran X,
Seoane L,
and
Broquetas JM.
Diaphragmatic activity induced by cortical stimulation: surface versus esophageal electrodes.
J Appl Physiol
74:
655-658,
1993.
7.
Horning, MR,
Kraft GH,
and
Guy A.
Latencies recorded by intramuscular needle electrodes in different portions of a muscle: variation and comparison with surface electrodes.
Arch Phys Med Rehabil
53:
206-211,
1972.
8.
Khedr, EM,
El Shinawy O,
Khedr T,
Aziz Ali YA,
and
Awad EM.
Assessment of corticodiaphragmatic pathway and pulmonary function in acute ischemic stroke patients.
Eur J Neurol
7:
323-330,
2000.
9.
Lagueny, A,
Arnaud A,
Le Masson G,
Burbaud P,
Deliac P,
and
Marthan R.
Study of central and peripheral conductions to the diaphragm in 22 patients with definite multiple sclerosis.
Electromyogr Clin Neurophysiol
38:
333-342,
1998.
10.
Lissens, MA.
Motor evoked potentials of the human diaphragm elicited through magnetic transcranial brain stimulation.
J Neurol Sci
124:
204-207,
1994.
11.
Lissens, MA,
De Muynck MC,
Decleir AM,
and
Vanderstraeten GG.
Motor evoked potentials of the abdominal muscles elicited through magnetic transcranial brain stimulation [letter].
Muscle Nerve
18:
1353-1354,
1995.
12.
Lissens, MA,
and
Vanderstraeten GG.
Motor evoked potentials of the respiratory muscles in tetraplegic patients.
Spinal Cord
34:
673-678,
1996.
13.
Luo, YM,
Johnson LC,
Polkey MI,
Harris ML,
Lyall RA,
Green M,
and
Moxham J.
Diaphragm electromyogram measured with unilateral magnetic stimulation.
Eur Respir J
13:
385-390,
1999.
14.
Luo, YM,
Lyall RA,
Lou Harris M,
Rafferty GF,
Polkey MI,
and
Moxham J.
Quantification of the esophageal diaphragm electromyogram with magnetic phrenic nerve stimulation.
Am J Respir Crit Care Med
160:
1629-1634,
1999.
15.
Luo, YM,
Polkey MI,
Johnson LC,
Lyall RA,
Harris ML,
Green M,
and
Moxham J.
Diaphragm EMG measured by cervical magnetic and electrical phrenic nerve stimulation.
J Appl Physiol
85:
2089-2099,
1998.
16.
Luo, YM,
Polkey MI,
Lyall RA,
and
Moxham J.
Effect of brachial plexus co-activation on phrenic nerve conduction time.
Thorax
54:
765-770,
1999.
17.
Markand, ON,
Kincaid JC,
Pourmand RA,
Moorthy SS,
King RD,
Mahomed Y,
and
Brown JW.
Electrophysiologic evaluation of diaphragm by transcutaneous phrenic nerve stimulation.
Neurology
34:
604-614,
1984.
18.
Maryniak, O,
Yaworski R,
and
Hayes KC.
Intramuscular recording in neurodiagnostic studies.
Am J Phys Med Rehabil
68:
186-191,
1989.
19.
Maskill, D,
Murphy K,
Mier A,
Owen M,
and
Guz A.
Motor cortical representation of the diaphragm in man.
J Physiol
443:
105-121,
1991.
20.
Murphy, K,
Mier A,
Adams L,
and
Guz A.
Putative cerebral cortical involvement in the ventilatory response to inhaled CO2 in conscious man.
J Physiol
420:
1-18,
1990.
21.
Newsom Davis, J.
Phrenic nerve conduction in man.
J Neurol Neurosurg Psychiatry
30:
420-426,
1967.
22.
Plassman, BL,
and
Gandevia SC.
Comparison of human motor cortical projections to abdominal muscles and intrinsic muscles of the hand.
Exp Brain Res
78:
301-308,
1989.
23.
Similowski, T,
Attali V,
Bensimon G,
Salachas F,
Mehiri S,
Arnulf I,
Lacomblez L,
Zelter M,
Meininger V,
and
Derenne JP.
Diaphragmatic dysfunction and dyspnoea in amyotrophic lateral sclerosis.
Eur Respir J
15:
332-337,
2000.
24.
Similowski, T,
Catala M,
Rancurel G,
and
Derenne JP.
Impairment of central motor conduction to the diaphragm in stroke.
Am J Respir Crit Care Med
154:
436-441,
1996.
25.
Similowski, T,
Fleury B,
Launois S,
Cathala HP,
Bouche P,
and
Derenne JP.
Cervical magnetic stimulation: a new painless method for bilateral phrenic nerve stimulation in conscious humans.
J Appl Physiol
67:
1311-1318,
1989.
26.
Similowski, T,
Mehiri S,
Duguet A,
Attali V,
Straus C,
and
Derenne JP.
Comparison of magnetic and electrical phrenic nerve stimulation in assessment of phrenic nerve conduction time.
J Appl Physiol
82:
1190-1199,
1997.
27.
Similowski, T,
Straus C,
Attali V,
Duguet A,
Jourdain B,
and
Derenne JP.
Assessment of the motor pathway to the diaphragm using cortical and cervical magnetic stimulation in the decision-making process of phrenic pacing.
Chest
110:
1551-1557,
1996.
28.
Similowski, T,
Straus C,
Coic L,
and
Derenne JP.
Facilitation-independent response of the diaphragm to cortical magnetic stimulation.
Am J Respir Crit Care Med
154:
1771-1777,
1996.
29.
Sinderby, C,
Friberg S,
Comtois N,
and
Grassino A.
Chest wall muscle cross talk in canine costal diaphragm electromyogram.
J Appl Physiol
81:
2312-2327,
1996.
30.
Sinderby, CA,
Comtois AS,
Thomson RG,
and
Grassino AE.
Influence of the bipolar electrode transfer function on the electromyogram power spectrum.
Muscle Nerve
19:
290-301,
1996.
31.
Strohl, KP,
Mead J,
Banzett RB,
Loring SH,
and
Kosch PC.
Regional differences in abdominal muscle activity during various maneuvers in humans.
J Appl Physiol
51:
1471-1476,
1981.
32.
Taylor, A.
The contribution of intercostal muscles to the effort of respiration in man.
J Physiol
151:
390-402,
1960.
33.
Thompson, ML,
Thickbroom GW,
and
Mastaglia FL.
Corticomotor representation of the sternocleidomastoid muscle.
Brain
120:
245-255,
1997.
34.
Verin, E,
Straus C,
Demoule A,
Mialon P,
Derenne JP,
and
Similowski T.
Validation of improved recording site to measure phrenic conduction from surface electrodes in humans.
J Appl Physiol
92:
967-974,
2002.
35.
Zifko, U,
Remtulla H,
Power K,
Harker L,
and
Bolton CF.
Transcortical and cervical magnetic stimulation with recording of the diaphragm.
Muscle Nerve
19:
614-620,
1996.
This article has been cited by other articles:
![]() |
E. Z. Ross, A. V. Nowicky, and A. K. McConnell Influence of acute inspiratory loading upon diaphragm motor-evoked potentials in healthy humans J Appl Physiol, May 1, 2007; 102(5): 1883 - 1890. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Duguet, A. Demoule, J. Gonzalez, O. Remy-Neris, J. P. Derenne, and T. Similowski Predicting the recovery of ventilatory activity in central respiratory paralysis. Neurology, July 25, 2006; 67(2): 288 - 292. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. C. Glerant, N. Mustfa, W. D. Man, Y. M. Luo, G. Rafferty, M. I. Polkey, and J. Moxham Diaphragm electromyograms recorded from multiple surface electrodes following magnetic stimulation Eur. Respir. J., February 1, 2006; 27(2): 334 - 342. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. von Leupoldt and B. Dahme Cortical Substrates for the Perception of Dyspnea Chest, July 1, 2005; 128(1): 345 - 354. [Abstract] [Full Text] [PDF] |
||||
![]() |
W.D-C. Man, J. Moxham, and M.I. Polkey Magnetic stimulation for the measurement of respiratory and skeletal muscle function Eur. Respir. J., November 1, 2004; 24(5): 846 - 860. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Sharshar, N. S Hopkinson, S. Jonville, H. Prigent, R. Carlier, M. J Dayer, E. B Swallow, F. Lofaso, J. Moxham, and M. I Polkey Demonstration of a second rapidly conducting cortico-diaphragmatic pathway in humans J. Physiol., November 1, 2004; 560(3): 897 - 908. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Straus, C. Locher, M. Zelter, J.-P. Derenne, and T. Similowski Facilitation of the diaphragm response to transcranial magnetic stimulation by increases in human respiratory drive J Appl Physiol, September 1, 2004; 97(3): 902 - 912. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Verin, E. Ross, A. Demoule, N. Hopkinson, A. Nickol, B. Fauroux, J. Moxham, T. Similowski, and M. I. Polkey Effects of exhaustive incremental treadmill exercise on diaphragm and quadriceps motor potentials evoked by transcranial magnetic stimulation J Appl Physiol, January 1, 2004; 96(1): 253 - 259. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| Visit Other APS Journals Online |