|
|
||||||||
Departments of 1 Medicine, 2 Environmental Health Sciences, and 3 Anesthesiology, Johns Hopkins University, Baltimore, Maryland 21224
| |
ABSTRACT |
|---|
|
|
|---|
Altered perfusion
of the bronchial mucosal plexus relative to the adventitial plexus may
contribute to geometric changes in the airway wall and lumen. We
studied bronchial perfusion distribution in sheep by using fluorescent
microspheres at baseline and during intrabronchial artery challenge
with methacholine chloride (MCh; n = 7). Additionally,
we measured airway resistance (Raw) during MCh with control or
increased perfusion (n = 9). Raw with MCh was
significantly greater for high than control flow. Microspheres in
histological sections lodged predominantly in the mucosa (60%), and
this was not altered by MCh. However, more microspheres lodged in
airways >1-mm in diameter during MCh and increased perfusion than MCh
and control flow. In airways
1 mm in diameter, fewer microspheres
lodged during control than increased flow. If the number of
microspheres represents regional agonist access to airway smooth
muscle, then the differences observed in Raw can be explained by the
distribution of agonist. During challenge, there was greater MCh
delivery to larger airways during increased flow and less delivery to
smaller airways during control flow. The results demonstrate the
effects of axial perfusion distribution on Raw.
methacholine chloride; microspheres; sheep; bronchial blood flow; airway vasculature; airway hyperreactivity
| |
INTRODUCTION |
|---|
|
|
|---|
THE COMPLEX ANATOMY OF THE vasculature supplying the subcarinal airways has been known for many years. The unique arrangement of parallel vascular plexuses of the bronchial circulation was described by Miller (10). However, the precise route for blood flow through this vasculature is still unknown. Although the bronchial artery supplies the vessels of the outer adventitial plexus as well as the inner mucosal plexus, it is not clear whether changes in flow, vasodilation, or airway smooth muscle constriction alter perfusion distribution within the airway wall. The concept that adventitial engorgement and edema might alter airway-parenchymal tethering has been proposed (12). However, our laboratory's previous work demonstrated that neither a general increase in the airway wall area (4) or specific increase in adventitial area due to edema fluid (17), nor vascular congestion (3), altered airway luminal area or airway resistance (Raw). However, engorgement and edema of mucosal vessels have been suggested to encroach on the airway luminal space, thereby causing airway obstruction (12). Additionally, it is not clear whether the responsivity of vessels located in the adventitial plexus differs from that of mucosal vessels. Selective vasodilation of one bed may result in specific airway functional changes. Thus knowledge of the blood flow distribution is important. Fluorescent microspheres are a useful tool to study both spatial and quantitative distribution of blood flow. Glenny et al. (6) have used the technique extensively to chart the spatial distribution of pulmonary blood flow under a variety of experimental conditions. The technique also has been used to measure blood flow to airways (2). In the present study, we used fluorescent microspheres and morphometric techniques to determine the perfusion distribution of the bronchial artery within the normal airway wall and during experimentally controlled changes in bronchial blood flow, vasodilation, and airway smooth muscle constriction. We tested the hypothesis that, in sheep, methacholine, a bronchial vasodilator and airway smooth muscle constrictor, would shift the blood flow distribution within the airway wall to the mucosa and thereby contribute to enhanced Raw.
| |
METHODS |
|---|
|
|
|---|
Experimental preparation.
The Johns Hopkins Animal Care and Use Committee approved our study
protocol. Anesthesia was induced in sheep (25-35 kg) with intramuscular ketamine (30 mg/kg) and subsequently maintained with
pentobarbital sodium (20 mg · kg
1 · h
1). A
tracheotomy was performed, the sheep were paralyzed with pancuronium
bromide (2 mg iv), and the lungs were mechanically ventilated
(10-12 ml/kg) at a rate (12-15 breaths/min) sufficient to
maintain normal blood gases. Positive end-expiratory pressure (5 cmH2O) was applied. The left thorax was opened at the fifth intercostal space, and heparin (20,000 U) was administered. The esophageal and thoracic tracheal branches of the bronchoesophageal artery were ligated as previously described (18). The
bronchial branch of the bronchoesophageal artery was isolated,
cannulated, and perfused (0.6 ml · min
1 · kg
1) with
autologous blood withdrawn from the descending aorta and pumped through
a variable-speed roller pump (Gilson, Middleton, WI).
Raw.
In the first series of nine sheep, the effects of methacholine chloride
(MCh; Sigma Chemical, St. Louis, MO) on Raw were studied during control
bronchial blood flow and when bronchial blood flow was increased to
maintain a constant perfusion pressure despite bronchial vasodilation.
This series was performed to determine whether a functional difference
would be observed during a constant infusion of MCh delivered at two
different blood flows. Conducting Raw was measured by the method of
forced oscillation (7). A gas volume of ~30 ml was
oscillated for 1.5 s at a frequency of 9 Hz after each tidal
breath. Airway pressure was measured at a sidearm of the tracheal
cannula, and a flow signal was obtained from a pneumotachograph
positioned between the oscillator and the cannula. Oscillatory signals
were analyzed with an on-line computer that measured pressures at
points of peak flow. An average Raw was obtained over 8-10
oscillatory cycles. Baseline Raw measured in this manner in
anesthetized sheep typically results in a value of 1.0 to 2.0 cmH2O · l
1 · s. Airway
reactivity was determined by measuring Raw before and during
intrabronchial artery infusions of 0.5, 1, 2, and 5 µg/ml of MCh
(2.6 × 10
6, 5.1 × 10
6, 1.0 × 10
5, 2.6 × 10
5 M, respectively) at
a constant infusion rate of 1 ml/min (Harvard Instruments, Holliston,
MA) during two bronchial blood flow conditions. We obtained
concentration-response information while infusing each MCh
concentration directly into the bronchial artery at control blood flow
(0.6 ml · min
1 · kg
1).
However, because MCh is known to cause bronchial vascular dilation (19) and, in our system, decreases in bronchial artery
perfusion pressure, bronchial blood flow was next increased (high flow) by setting the roller pump to a level that produced a bronchial inflow
pressure equal to the bronchial artery pressure recorded at baseline
before the first MCh infusion. Steady-state Raw was measured again
after an additional 2-min MCh infusion. Then the MCh infusion was
stopped, blood flow was set to baseline level, and vascular resistance
and Raw returned to prechallenge values. This sequence was repeated for
each MCh concentration. In previous experiments, we confirmed that
steady-state airways constriction is achieved within 2 min of agonist
delivery (19).
Blood flow distribution.
To determine the blood flow distribution within subcarinal airways
served by the bronchial artery, fluorescent microspheres (15.5 µm;
E-Z Trac, Interactive Medical Technologies, North Hollywood, CA) were
infused directly into the bronchial artery in another series of seven
sheep. After vortexing, 2 × 106 (1 × 106 spheres/ml) fluorescent microspheres suspended in
0.01% Tween in normal saline followed by a 1-ml saline flush were
infused (1 ml/min; Harvard Instruments) through a side port of the
blood perfusion circuit immediately upstream from the bronchial
arterial cannula. MCh (2 µg/ml; 1 ml/min) was infused directly into
the bronchial artery through a side port of the blood perfusion
circuit upstream from the site of microsphere infusion. Four
different fluorescent-colored (fluorescein, 9-aminoacridine, eosin Y,
pyronin B) microspheres were randomized for use during four
experimental conditions: 1) control perfusion (0.6 ml · min
1 · kg
1),
2) MCh infusion with an increased blood flow (to match
control perfusion pressure), 3) MCh infusion, and
4) increased blood flow alone. The first three protocols
were randomized; however, the increased-flow protocol was performed
after the MCh with increased flow, so flow conditions could be matched.
Because our laboratory has previously demonstrated that microspheres
can have a vasodilatory effect on the bronchial vasculature
(13), a 15- to 30-min recovery time was allowed after each
microsphere infusion so that bronchial artery pressure could recover to
baseline level after each injection. Relative microsphere distribution
was determined by examining thick (20-µm) sections of the
airway segments prepared histologically. Fluorescent spheres contained
in sections of airways were counted and the mucosal and adventitial
distribution was determined.
Histology. After each sheep was exsanguinated, the right middle lobe was removed, inflated with 100-150 ml of 4% formaldehyde in 0.1 M phosphate buffer (pH 7.4), and then submerged in 500 ml of the same fixative overnight. The next day, the fixed lobe was cut transversely into three regions (superior, medial, and inferior). Each region was then cut into twenty to twenty-five 1- to 2-cm cubes, washed overnight in buffer to remove the formaldehyde, and infiltrated overnight in a mixture of 50% distilled H2O-50% OCT followed by an additional 18- to 24-h infiltration in 100% OCT. Tissue blocks were oriented in a cryomold so that large airways would be cut in cross section and then frozen in liquid nitrogen-cooled methylbutane for 15 s. Twenty-six alternating 20-µm cryostat sections (comprising ~1.0-mm airway length) of each block were collected on glass slides. The colors, location (internal or external to airway smooth muscle), and number of microspheres within the airway wall in each complete 1-mm length of airway sample were determined by fluorescent microscopy by using an Olympus BX60 microscope equipped with a U-M61002 D/F/TR709 multiwavelength fluorescent filter cube. The basement membrane perimeter was measured by using NIH Image software, and the maximum airway diameter was calculated. An effort was made to count ~45 airways/sheep.
Analysis. All data are presented as means ± SE. Concentration-response relationships were analyzed by two-way analysis of variance with the Scheffé's correction for post hoc comparisons. Microsphere measurements for all airways were pooled for each protocol and also analyzed by two-way analysis of variance with the Scheffé's correction for post hoc comparisons. Significance was accepted at P < 0.05.
| |
RESULTS |
|---|
|
|
|---|
Baseline bronchial artery pressure for the entire group of 16 sheep (body weight 31 ± 1 kg) that were studied was 107 ± 6 mmHg at control bronchial blood flow (19 ± 1 ml/min). Bronchial vascular resistance, estimated as the steady-state inflow
pressure/control flow, resulted in an average 5.8 ± 0.4 mmHg · ml
1 · min. In the first series,
baseline Raw averaged 1.0 ± 0.2 cmH2O · l
1 · s. MCh
administration directly into the bronchial artery caused concentration-dependent vasodilation. After the highest MCh
concentration, bronchial artery pressure decreased to 60 ± 6 mmHg
at control flow, and, to maintain constant pressure, bronchial blood
flow was increased to a maximal flow of 46 ± 3 ml/min. The
concentration-dependent effects of MCh on Raw during the two blood flow
conditions are shown in Fig. 1. Despite a
constant infusion of MCh, the increase in Raw was greater for the
high-blood flow condition at each MCh concentration (P < 0.0001).
|
The average total number of fluorescent microspheres lodged in the
airway wall during control flow conditions is presented in Fig.
2. Increasing airway size was correlated
with an increase in the total number of lodged microspheres (r
= 0.45; P = 0.0001), suggesting that vascularity
contributes to airway wall mass, which increases in proportion to
airway size (11). The actual number of airways counted per
airway size category is inserted within each bar. When the four
experimental conditions are compared, there was a significant
difference in the average total number of microspheres among the four
conditions. The mean number of microspheres was 30 ± 2, 42 ± 3, 25 ± 2, and 32 ± 2 for the control, MCh + high-flow, MCh, and high-flow alone conditions respectively. Most
interestingly, the number of microspheres measured in airway walls
during the MCh + high-flow condition was significantly greater than in airways during MCh (P < 0.0001). Furthermore,
there are significant differences between the MCh + high-flow and
the high-flow alone conditions (P = 0.02) and between
the control and the MCh + high-flow conditions (P = 0.0008). Surprisingly, there was no difference in the average number
of microspheres in the airways between the control flow condition and
during either the MCh treatment (P = 0.53) or the
high-flow condition (P = 0.93).
|
When we analyzed the airways dichotomously as small (
1 in mm
diameter) and large (>1 mm in diameter) airways, thereby evaluating similar size groups, overall the large airways had a significantly greater number of spheres than small airways (P = 0.0001). Figure 3 shows the average total
number of microspheres for each treatment. Within airways
1 mm in
diameter, only MCh treatment caused a significant decrease in the total
number of microspheres relative to MCh + high flow
(P = 0.008) and high flow (P = 0.01)
but did not achieve statistical significance relative to control
(P = 0.07). The total number of microspheres was
indistinguishable from control after MCh + high flow
(P = 0.41) and high flow (P = 0.42). For airways >1 mm in diameter, the total number of
microspheres lodged during MCh + high flow were significantly
greater than control (P = 0.0007), MCh
(P = 0.004), and high flow alone (P = 0.0007). The total number of microspheres counted for control conditions was not different from MCh (P = 0.99) or
high flow (P = 0.99).
|
In addition, we analyzed the distribution of fluorescent microspheres lodged within the airway wall during the four conditions. The percentage of spheres located within the mucosal region of the airway wall relative to the total number of spheres lodged in a specific airway (%mucosal) was 69 ± 1, 69 ± 2, 69 ± 2, and 62 ± 2% for the control, MCh + high-flow, MCh, and high-flow alone conditions, respectively (P = 0.01). The high-flow condition demonstrated a small difference from both control (P = 0.04) and MCh + high flow (P = 0.05).
When the airways are analyzed dichotomously as small and large airways
and the treatment is held constant, the large airways demonstrated a
small but significant increase in the percentage of microspheres lodged
in the mucosa relative to small airways (P = 0.004). As
observed in Fig. 4, the distribution of
microspheres is predominantly mucosal and does not differ substantially
across treatment in either airway size category. In the large airways, there were no significant differences among treatment groups
(P > 0.33). Furthermore, in the small-airway groups,
only the high-flow condition showed a small decrease in the
distribution relative to MCh + high flow (P = 0.002). None of the treatments differed from control (P > 0.12).
|
| |
DISCUSSION |
|---|
|
|
|---|
A role for the airway circulation in contributing to or modulating airflow obstruction is not clear. Several investigators have demonstrated that increases in airway blood flow contribute to the passive washout of airway smooth muscle agonists (8, 19). However, others have suggested that hyperemia and vascular engorgement contribute to airway narrowing (5). The purpose of the present study was to document the bronchial blood flow distribution within the airway wall during basal conditions as well as during agonist challenge. The overall goal was to determine whether shifts in perfusion distribution could explain changes in airway function. Our results demonstrate that increases in Raw during intravascular MCh challenge were significantly greater when bronchial blood flow was increased. Furthermore, our data demonstrate that changes in bronchial perfusion alone did not change the distribution of microspheres within the airway wall to either the large or small airways. Intrabronchial artery infusion of MCh alone caused a decrease in the number of microspheres to the small airways, whereas the combination of MCh and high flow increased the number of microspheres to the large airways.
The physical setup of these experiments and the fact that MCh dilates
the bronchial vasculature as it constricts airway smooth muscle allowed
us to compare the steady-state effects of a constant infusion of MCh at
two different bronchial blood flow settings. At each of four MCh
concentrations, the increases in Raw were significantly greater during
the high flow at constant bronchial perfusion pressure condition than
during the control flow with decreased perfusion pressure condition.
However, our microsphere data demonstrated that the blood flow
distribution within the airway wall always remained unchanged. Although
small airways (
1 mm in diameter) had slightly less mucosal perfusion
than larger airways (>1 mm in diameter), in general, distribution of
blood flow was predominantly to the mucosa (>60%). Furthermore,
during each of the four experimental conditions (control flow, MCh + high flow, MCh + control flow, high flow), an approximately
equivalent parallel perfusion distribution (i.e., within the wall at
any given axial location) with 15.5-µm microspheres was
obtained. We interpret this result as demonstrating that the
physical effects of blood flow could not account for the differences
observed in Raw during the challenge protocols.
However, the results showing total numbers of microspheres delivered to the different sized airways during the four experimental conditions (Fig. 3) does offer a plausible explanation for the differences in Raw reported. First, the number of microspheres lodged in the larger airways (>1 mm in diameter) was significantly elevated only during the MCh + high-flow condition. This finding may explain the increased Raw in this hemodynamic state because Raw is more dependent on large than small airways (14). Increased delivery to these larger airways might lead to increased airway smooth muscle constriction. Furthermore, increased flow alone did not increase the total number of microspheres lodged in this size of airways, suggesting that increased flow and higher than normal perfusion pressures resulted in shunt flow that bypassed 15.5-µm vessels and did not recruit new vessels as did the vasodilator MCh. Although we did not measure shunt flow, this is an interpretation of our results. In retrospect, it would have been useful to measure the concentration of microspheres reaching the left heart as an index of shunt flow. We did not see fluorescent microspheres lodged in the pulmonary capillaries.
In the smaller airways (
1 mm in diameter), the only condition that
resulted in a significant change in the number of microspheres lodged
was during MCh alone. Thus there was a significant decrease in the
delivery of the airway smooth muscle agonist to the smaller airways
only during MCh delivery at control flow. The decreased perfusion
pressure likely was responsible for the decreased numbers of
microspheres during MCh at control flow. However, it appears that the
vasculature of the smaller airways remained fully recruited during the
other three conditions because the number of microspheres did not
differ among control, MCh + high flow, and high flow alone. Thus
the results showing Raw greater during MCh challenge and high flow than
MCh challenge and control flow were due to the combined effects of
increased MCh delivery to larger airways during high flow and decreased
delivery of MCh to smaller airways during control flow. This statement
assumes that MCh delivery to airway smooth muscle can be deduced from
the lodging of 15.5-µm microspheres in precapillary arterioles of the
airway vasculature as well as that the measure of Raw includes these
sizes of airways. Although our hypothesis suggested that parallel
redistribution within the airway wall would be associated with
differences in Raw, only the axial redistribution manifested itself
with these experimental protocols.
Consistent with these observations, Scuri et al. (16) showed proportionate changes in blood flow to mucosal and deep wall vessels treated with intravenous acetylcholine. However, in their study, blood flow measurements were made 10 min after an intravenous bolus injection of acetylcholine. Thus it is not clear that changes in regional blood flow observed with lodged microspheres represented steady-state or recovery measurements. Interestingly, these authors reported that mucosal flow comprised 72% of total airway blood flow to large extraparenchymal (mainstem bronchi) airways. This value is close to that observed in the larger airways (>1 mm in diameter) in the present study (Fig. 4).
Although 15-µm radiolabeled microspheres have long been used to measure regional organ blood flow (15), the availability of fluorescent microspheres has allowed for precise determination of regional distribution when combined with quantitative morphometry (6). Luchtel et al. (9) explored and reported on a variety of tissue fixation techniques to maximize visualization of microspheres. In our preliminary studies, 20-µm-thick sections were the maximum thickness that allowed clear visualization of microspheres lodged within subcarinal airways and their location (internal or external to airway smooth muscle). The standard 15-µm-sized microspheres lodge in precapillary arterioles and have been used extensively to measure airway blood flow (1).
Although our study design involved intrabronchial vascular delivery of agonist, we believe the results have implications for aerosol challenge also. Whereas inhaled contractile agonists may reach airway smooth muscle by direct diffusion from airway lumen to smooth muscle, it is likely that a substantial fraction is taken up in transit by the airway mucosal vasculature as well as the pulmonary capillaries of the peripheral lung. Thus some fraction of the inhaled agonist can be carried in the blood to other sites. We showed previously that the increase in airways resistance induced with an intravenous agonist challenge can be almost completely prevented if the bronchial artery is obstructed (20). These results were interpreted to suggest that agonist in the pulmonary capillaries recirculates to the systemic bronchial circulation where it more directly reaches airway smooth muscle. Consequently, some of aerosolized agonist reaching the lung periphery recirculates to affect both bronchial smooth muscle and bronchial blood flow. From the perspective of study design, we wanted to examine the possibility that blood flow distribution within the airway wall could affect airway function. To study whether this mechanism is operative, we delivered the agonist directly to the bronchial artery where we could control the delivery precisely. Although the study of blood flow distribution within the airway wall after aerosol challenge is of interest, given the lack of precision of aerosol delivery, we opted to study the plausibility of our hypothesis in a preparation that could be controlled more tightly. Our results show that, in a controlled preparation, both vascular resistance and driving pressure can affect the overall airway smooth muscle effect. On the basis of the results of this study, both of these factors could affect intravascular axial delivery of agonist but ultimately could also affect clearance of agonist from airway smooth muscle. Each of these factors contribute to the complexity of the measurement of airways reactivity.
In summary, we have challenged subcarinal airways with an agent that
constricts airway smooth muscle and dilates vascular smooth muscle.
These dual properties of MCh enabled us to measure Raw at two
physiological bronchial blood flow levels that bracket the normal in
vivo response. Because of the enhanced Raw observed during the
high-flow condition, we evaluated perfusion distribution by examining
histological sections after injecting fluorescent microspheres. The
radial perfusion distribution within the airway wall was unaltered by
any of the experimental conditions. However, larger airways (>1 mm)
demonstrated increased numbers of fluorescent microspheres during MCh
challenge and high flow, whereas smaller airways (
1 mm in diameter)
showed decreased numbers of microspheres during MCh challenge alone
compared with control. We assumed that the quantification of
fluorescent microspheres represented the availability of agonist to
smooth muscle within the airways measured and that the determination of
Raw included these airways. Thus the difference in airway reactivity
was related to the delivery of both more agonist to larger airways
during high flow and less agonist to smaller airways during control
flow. The results demonstrate the influence of perfusion distribution
on the measured physiological end point of Raw.
| |
ACKNOWLEDGEMENTS |
|---|
This work was supported by National Heart, Lung, and Blood Institute Grants HL-58577 and HL-10342.
| |
FOOTNOTES |
|---|
Address for reprint requests and other correspondence: E. M. Wagner, Johns Hopkins Asthma and Allergy Center, Div. of Pulmonary and Critical Care Medicine, 5501 Hopkins Bayview Circle, Baltimore, MD 21224 (E-mail: wagnerem{at}jhmi.edu).
The costs of publication of this article were defrayed in part by the payment of page charges. The article must therefore be hereby marked "advertisement" in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.
First published January 18, 2002;10.1152/japplphysiol.00721.2001
Received 10 July 2001; accepted in final form 3 January 2002.
| |
REFERENCES |
|---|
|
|
|---|
1.
Baile, EM,
Sotres-Vega A,
and
Par PD.
Airway blood flow and bronchovascular congestion in sheep.
Eur Respir J
7:
1300-1307,
1994.
2.
Bernard, SL,
Glenny RW,
Polissar NL,
and
Luchtel DL.
Distribution of pulmonary and bronchial blood supply to airways measured by fluorescent microspheres.
J Appl Physiol
80:
430-436,
1996.
3.
Blosser, S,
Mitzner W,
and
Wagner EM.
Effects of increased bronchial blood flow on airway morphometry, resistance, and reactivity.
J Appl Physiol
76:
1624-1629,
1994.
4.
Brown, R,
Mitzner W,
and
Wagner E.
Interaction between airway edema and lung inflation on responsiveness of individual airways in vivo.
J Appl Physiol
83:
366-370,
1997.
5.
Gilbert, IA,
Winslow CJ,
Lenner KA,
Nelson JA,
and
McFadden ER.
Vascular volume expansion and thermally induced asthma.
Eur Respir J
6:
189-197,
1993.
6.
Glenny, RW,
Bernard S,
and
Brinkley M.
Validation of fluorescent-labeled microspheres for measurement of regional organ perfusion.
J Appl Physiol
74:
2585-2597,
1993.
7.
Goldman, M,
Kundson RJ,
Mead J,
Peterson N,
Schwaber JR,
and
Wolh ME.
A simplified measurement of respiratory resistance by forced oscillation.
J Appl Physiol
28:
113-116,
1970.
8.
Kelly, L,
Kolbe J,
Mitzner W,
Spannhake EW,
Bromberger-Barnea B,
and
Menkes H.
Bronchial blood flow affects recovery from constriction in dog lung periphery.
J Appl Physiol
60:
1954-1959,
1986.
9.
Luchtel, DL,
Boykin JC,
Bernard SL,
and
Glenny RW.
Histological methods to determine blood flow distribution with fluorescent microspheres.
Biotech Histochem
73:
291-309,
1998.
10.
Miller, W.S.
The Lung (2nd ed.). Springfield, IL: Thomas, 1947.
11.
Okazawa, M,
Muller N,
McNamara AE,
Child S,
Verburgt L,
and
Pare PD.
Human airway narrowing measured using high resolution computed tomography.
Am J Respir Crit Care Med
154:
1557-1562,
1996.
12.
Paré, PD,
Yager DC,
and
Godden DJ.
Airway edema.
In: The Lung: Scientific Foundations, edited by Crystal RG,
West JB,
Barnes PJ,
and Weibel ER.. Philadelphia, PA: Lippincott-Raven, 1997, p. 1355-1364.
13.
Pearse, DB,
Fessler H,
and
Wagner EM.
Polystyrene microspheres decrease bronchial artery resistance in anesthetized sheep.
Am J Physiol Heart Circ Physiol
269:
H1037-H1043,
1995.
14.
Pedley, T,
Schroter R,
and
Sudlow M.
Gas flow and mixing in the airways.
In: Bioengineering Aspects of the Lung, edited by West JB.. New York: Dekker, 1977, p. 163-265.
15.
Rudolf, AM,
and
Heyman MA.
The circulation of the fetus in utero: methods for studying distribution of blood flow, cardiac output and organ blood flow.
Circ Res
21:
163-184,
1967.
16.
Scuri, M,
McCaskill V,
Chediak AD,
Abraham WM,
and
Wanner A.
Effect of inhaled and intravenous acetylcholine on bronchial blood flow in anesthetized sheep.
J Appl Physiol
80:
341-344,
1996.
17.
Wagner, EM.
Effects of edema on small airway narrowing.
J Appl Physiol
83:
784-791,
1997.
18.
Wagner, EM,
and
Mitzner WA.
Effect of left atrial pressure on bronchial vascular hemodynamics.
J Appl Physiol
69:
837-848,
1990.
19.
Wagner, EM,
and
Mitzner WA.
Bronchial circulatory reversal of methacholine-induced airway constriction.
J Appl Physiol
69:
1220-1224,
1990.
20.
Wagner, EM,
and
Mitzner WA.
Contribution of pulmonary versus systemic perfusion of airway smooth muscle.
J Appl Physiol
78:
403-409,
1995.
This article has been cited by other articles:
![]() |
J. M. Dybas, C. J. Andresen, E. S. Schelegle, R. W. McCue, N. N. Callender, and A. C. Jackson Deep-breath frequency in bronchoconstricted monkeys (Macaca fascicularis) J Appl Physiol, March 1, 2006; 100(3): 786 - 791. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Savai, J. C. Wolf, S. Greschus, B. G. Eul, R. T. Schermuly, J. Hanze, R. Voswinckel, A. C. Langheinrich, F. Grimminger, H. Traupe, et al. Analysis of Tumor Vessel Supply in Lewis Lung Carcinoma in Mice by Fluorescent Microsphere Distribution and Imaging with Micro- and Flat-Panel Computed Tomography Am. J. Pathol., October 1, 2005; 167(4): 937 - 946. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Moldobaeva and E. M. Wagner Angiotensin-converting enzyme activity in ovine bronchial vasculature J Appl Physiol, December 1, 2003; 95(6): 2278 - 2284. [Abstract] [Full Text] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| Visit Other APS Journals Online |