Department of Pharmacology, Midwestern University, Downers Grove, Illinois 60515
| |
ABSTRACT |
|---|
|
|
|---|
The inherent electrical
resistance of the rat vaginal wall rises markedly near the beginning of
estrus and then falls again to low levels for the remainder of the
ovarian cycle. Accordingly, special instruments have been developed to
measure such resistances (within seconds) on simply inserting a small
probe fitted with a pair of recording electrodes into the vagina (i.e.,
the MK-10A impedance checker and the EC40 estrus cycle monitor). As
described herein, these two instruments are far more convenient for
monitoring individual cycles than more laborious methods in which
vaginal smears are inspected for changes in numbers of cornified (C), nucleated (N), and leukocytic (L) cells. However, they are also expensive and their use has essentially remained uncited in the literature. Thus we sought to determine whether a simple, inexpensive electrical meter (with resistance-measuring capacity), as commonly used
by professional electricians, would serve the same purpose. We chose a
standard multifunctional meter (model 22-178, RadioShack) and attached
leads to it fabricated from the internal wiring of a shielded
audiocable (model 42-2387A, RadioShack), one male terminal of which was
used as a vaginal probe. In rats from which vagina smears
revealed cell numbers in the order of C > N > L (typical of
early estrus) electrical resistances were high, 488 ± 130 k
(18 rats). In rats from which vagina smears revealed all other possible
cell distributions, electrical resistances (combined) were much lower
(P < 0.05), 124 ± 23 k
(32 rats). Thus
readily accessible, inexpensive electrical meters may be useful in
assessing the status of estrus in female rats, either to improve
reproductive efficiencies and/or for other purposes involving
experiments in which such information is desirable.
estrus; female rat; tissue
| |
INTRODUCTION |
|---|
|
|
|---|
IT HAS BEEN KNOWN FOR SEVERAL years that the various stages of the ovarian cycle can be identified from vaginal smears in most animals, including rats (6). However, the detailed preparation and tedious assessment of vaginal cytologic features in smears is very time consuming. Thus the discovery that the inherent electrical resistance of the vaginal wall changes predictably during the different phases of the ovarian cycle is not only highly useful to laboratory research with female animals in general but also to the animal breeding industry (10). Such resistance measurements take only seconds to obtain and are much less amenable to subjective interpretation on the part of the technical operator than the more conventional vaginal smear methodology. Unfortunately, the instrumentation previously described to make such resistance measurements in the rat (1, 3, 4) is complex and difficult to fabricate in the laboratory. Two instruments have been manufactured specifically for rat and made commercially available in ready-to-use forms [i.e., the MK-10A impedance checker (Muromachi Kikai, Tokyo, Japan) and the EC40 estrus cycle monitor (Fine Science Tools, Foster City, CA)]. But they are relatively expensive. This may explain why these two instruments plus the primary publications describing their initial use (3, 4) have essentially remained uncited in the biomedical literature. As yet, there is no simple and inexpensive form of such instrumentation readily available to the average laboratory for routine use with rats. Thus one goal of this project was to test a typical, inexpensive, locally available electrical resistance meter for its ability to detect changes in vaginal wall resistances during estrus compared with vaginal smear measurements in female laboratory rats. Another goal was to determine whether the same meter would detect the very marked fall in rat vaginal resistance measurements known to occur after ovariectomy (4).
| |
METHODS |
|---|
|
|
|---|
Animals.
Sexually mature female Sprague-Dawley rats (~250-300 g) from
Harlan (Indianapolis, IN) were used in the two studies (plus preliminary work) described below. All were fed food (standard rat
chow) and water ad libitum under a 12:12-h light-dark cycle. They were
all housed individually in solid plastic cages (46 × 23 × 20 cm; with 46 × 23-cm wire grid tops) containing heat-dried, ground corncob as bedding, which was changed weekly. This type of
individual housing was maintained for at least 4 wk in a
well-ventilated room (
10 fresh-air changes/h) before experimentation
in an attempt to randomize the rats' ovarian cycles (7,
8). In addition, a number of them were ovariectomized at least 2 wk before use in the second study. Except in a few instances, all rats
were lightly anesthetized with ketamine (40 mg/kg) and xylazine (4 mg/kg) given intraperitoneally immediately before experimental use to
satisfy animal care-and-use concerns that might arise in an initial
project of this type.
Instrumentation.
To measure the inherent electrical resistance of the inner lining of
the vaginal wall, we chose to use one of several typical digital
multimeters commonly employed by professional electricians to measure
resistances (as well as voltages and currents) in various types of
electrical circuits. The meter we chose (model 22-178, RadioShack,
Forth Worth, TX) is portable, battery operated, and measures
resistances over a wide range, from ohms to kiloohms to megaohms with
an accuracy of ± 1% at the kiloohm level. Yet, it is only a
small fraction of the total cost required to purchase one of the two
currently available special instruments described above in the
Introduction. For a vaginal probe, we used one of the male terminals
(plugs) of a typical inexpensive shielded audiocable (model 43-2837A,
RadioShack), the internal wiring of which was cut and fitted with
solderless banana plugs to allow contact with the meter. Such a
terminal consists of three smooth-metal conductors separated by two
rings of nonmetallic material serving as isolators (Fig.
1). Preliminary experiments revealed
that, of these three conductors (shown in Fig. 1 as the tip, middle,
and base of the terminal), electrical resistance values for the inner
vaginal wall recorded between the middle and base were the most stable over time (several seconds) after insertion of the terminal into the
vagina. Thus this combination was used in all subsequent studies. Furthermore, stability of resistance readings appeared to be influenced very little by the order in which the cable wiring (leads) from the
middle and base segments of the terminal were connected to the negative
and positive jacks of the meter. However, in all the experiments
described below, the banana plug for the base lead was always plugged
into the negative jack (the center jack of the 3 on the meter) and the
banana plug for the middle lead was always plugged into the positive
jack (the jack on the right side of the meter). A third jack on the
meter (left side) was never used because it is not intended for
resistance measurements.
|
Studies.
Two studies were performed, one in which the relationship of vaginal
electrical resistance measurements to vaginal smear cell numbers was
examined in sexually mature female rats (Fig.
2) and a second in which vaginal
electrical resistance measurements were obtained from ovariectomized
female rats and compared with those obtained in parallel from intact
rats (see Fig. 4). In both studies, the vaginal probe described
above was inserted for ~30 s. In the first study, a vaginal smear was
obtained from each rat immediately after the probe was removed. Each
smear was stained and fixed on a glass slide with Kwik-Diff reagents
(Shandon, Pittsburgh, PA) and then examined under a
microscope for cell types and relative numbers (Figs. 2 and
3). Cells were identified as
either nucleated (N), cornified (C), or leukocytic (L) (Fig. 3) by
criteria described in detail previously (6). Aided
by a standard, multikeyed laboratory counter (model 02-670-13, Fisher
Scientific), cells were counted in enough fields of vision (selected at
random at a magnification = ×40) from each smear to provide a
total of at least 100 cells per smear. Numbers of each cell type were
then expressed as percentage (mean ± SE) of the total number
counted. In a few of the rats from the second study (3 ovariectomized
and 3 intact), vaginal resistances were recorded twice, once while the
rats were conscious and again (5-10 min later) while they were
under the same light anesthesia applied to all the other rats in that
study. In both studies, all resistance measurements were summarized as
means ± SE per experimental group and analyzed for statistically
significant differences at P < 0.05.
|
|
| |
RESULTS |
|---|
|
|
|---|
In our first study, we found that the inherent electrical
resistance levels of the inner vaginal wall as measured with the meter
described in METHODS were clearly highest in those rats in
which the major vagina smear cell type was C, as opposed to either N or
L (Fig. 2). In addition, if these same rats were further separated
according to the complete order of vaginal smear cell numbers, then the
highest resistance levels were limited to those in which that cell
order was C > N > L (resistances = 488 ± 130 k
; 18 rats) as opposed to C > L > N (resistances = 163 ± 32 k
; 6 rats; P < 0.05). Similar
separation of rats in which the major cell type was either nucleated
(N > C > L vs. N > L > C) or leukocytic (L > C > N vs. L > N > C) did not produce statistically
significant differences. Rather, the above-mentioned highest average
resistance level of 488 ± 130 k
for the 18 rats with the smear
cell order of C > N > L was higher than the overall average
resistance level associated with all other cell orders combined in this
study (124 ± 23 k
; 32 rats; P < 0.05). The three major cell types as observed in this study are
illustrated in Fig. 3.
In our second study, we found that the same meter also detected the
marked lowering of vaginal wall resistance levels known to occur with
ovariectomy in the sexually mature female rat (Fig. 4). We did not collect smears from the
control rats with intact ovaries in this study. Control rats were
simply selected at random from individually housed rats at the same
time that we measured resistances in the ovariectomized rats. However,
the low average resistance level of the ovariectomized rats (Fig. 4) is
also notably less than any of the three average resistance levels of
the rats from our first study in which smears were collected and
inspected (shown in Fig. 2). In addition, resistance readings from a
few conscious rats in this second study did not differ significantly from readings recorded in the same rats under light anesthesia (the
latter readings equaled 97 ± 2% of the conscious readings, n = 6 rats).
|
| |
DISCUSSION |
|---|
|
|
|---|
The main findings from these experiments are as follows. First, in sexually mature female rats from which vaginal smears revealed cell numbers in the order of C > N > L (typical of early estrus), electrical resistances of the vaginal wall as measured by a commonly used inexpensive multimeter were much higher than in rats from which smears revealed N or L cells as the major cell type, or even cell numbers in the order of C > L > N (typical of late estrus). Second, ovariectomy, which has been shown previously to markedly reduce vaginal wall electrical resistance levels (4), did so as well in another study from this work as detected by the same meter. In addition, vaginal wall resistance measurements recorded in a select number of rats were not influenced by whether the animals were conscious or anesthetized. Thus readily accessible, ready-to-use, inexpensive electrical meters may be useful in assessing the status of estrus in female rats either to improve reproductive efficiencies and/or for other purposes involving experiments in which such information is desirable.
There are three topics related to this work that should be discussed in some detail.
First, the audiocable terminal employed as a vaginal probe in these experiments consisted of potentially three electrical conductors, illustrated in Fig. 1 from left to right as the tip, middle, and base of the terminal. As described in METHODS, preliminary experiments revealed that the stability of the vaginal wall resistance values was best when recorded between the base and middle conductors. The most likely reason that resistances were less stable when recorded with the tip (either tip to middle or tip to base) may relate to its irregular shape. Unlike the middle or base, the tip is not perfectly cylindrical but rather partially indented (Fig. 1). Thus contact of the tip with the vaginal wall could conceivably vary enough from moment to moment to influence resistance readings, especially if the smooth muscle of the wall should intermittently contract and relax at various times during the measurement.
Second, electrical resistance values for rat vaginal tissue as measured in the present work were much higher overall than those reported previously by others (1, 3, 4). This may be due to a specific difference in the electrical characteristics of the RadioShack instrument used in the present study compared with the instruments used in the previous studies. In particular, it may relate to the manner in which current is applied to the tissue from these instruments. To be capable of measuring the inherent resistance of any electrical circuit, an instrument must be able to deliver at least a small current to the circuit under a controlled voltage. For the meter used in the present work and all those used previously by others to measure tissue resistances in live subjects (1-5, 9), such currents and voltages are very low (i.e., in micoampere and millivolt ranges). They are not capable of exciting the tissues and/or being sensed by the subjects (9). However, the meter in this work (and any similar device that is commonly used by professional electricians) only delivers such current in one direction. All the other instruments previously used by the other above-mentioned laboratories to measure vaginal wall resistances (1-5) deliver a rapidly oscillating (alternating) current. Conceivably, tissue resistance to the passage of such current may be lower than when the current is only moving in one direction.
Third, results from this work also differ from those reported by the other laboratories studying rats in terms of when, within the ovarian cycle, the highest resistance values occur. As measured by the RadioShack meter in the present experiments, the highest resistances were linked to vaginal smear data associated mainly with early estrus, i.e., when the smear cell order is clearly C > N > L. Previously, others had reported peak resistances in rats even earlier, during proestrus (1, 3, 4), presumably when they found smears containing mostly nucleated cells. Although smear data were collected in those studies, actual cell numbers and related interpretations were not clearly presented (1, 3, 4). However, two other laboratories have reported similar differences in the location of peak electrical resistance values for vaginal tissue in guinea pigs (2, 5). In the first, peak resistances were said to occur in proestrus (2). Unfortunately, the actual vaginal smear data for the guinea pigs used in that study were not revealed (2). In a later (second) guinea pig study in which all smear cell data were presented in considerable detail, peak resistances occurred later than proestrus, indeed, well into late estrus (5). Although the primary instrumentation used to measure resistances in these two guinea pig studies was essentially the same, one noteworthy difference was discussed by the second group of investigators in terms of the distance separating the recording elements of the vaginal probes employed. This distance was only 1 mm in the second study (5) compared with 6 mm in the first (2). It is difficult to appreciate how a difference in this distance might influence when, within the ovarian cycle, peak resistances might be detected in the guinea pig vagina. However, it is precisely this same difference that separates the findings of the present experiments from all the previous results with rats discussed above (1, 3, 4). For the probe used in the present experiments (with rats) the distance separating the recording elements (middle to base sections of the terminal illustrated in Fig. 1) was even somewhat less than 1 mm, whereas in all the other rat studies (in which peak resistances were reported to occur in proestrus) that distance was typically 3-4 mm (1, 3, 4).
| |
ACKNOWLEDGEMENTS |
|---|
The authors acknowledge the excellent secretarial assistance of Victoria Sears and the expert technical and photographic assistance of Ronald Warfield and Dr. Celeste Pearson of the Department of Pharmacology at Midwestern University.
| |
FOOTNOTES |
|---|
Address for reprint requests and other correspondence: J. D. Peuler, Midwestern Univ., Dept. of Pharmacology, 555 31st St., Downers Grove, IL 60515 (E-mail: jpeule{at}midwestern.edu).
The costs of publication of this article were defrayed in part by the payment of page charges. The article must therefore be hereby marked "advertisement" in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.
Received 26 June 2000; accepted in final form 22 March 2001.
| |
REFERENCES |
|---|
|
|
|---|
1.
Bartos, L.
Vaginal impedance measurement used for mating in the rat.
Lab Anim
11:
53-55,
1977
2.
Bartos, L,
and
Sedlacek J.
Vaginal impedance measurement used for mating in the guinea pig.
Lab Anim
11:
57-58,
1977
3.
Koto, M,
Miwa M,
Togashi M,
Tsuji K,
Okamoto M,
and
Adachi J.
A method for detecting the optimum day for mating during 4-day estrous cycle in the rat: measuring the value of electrical impedance of vagina.
Exp Anim
36:
195-198,
1987.
4.
Koto, M,
Miwa M,
Tsuji K,
Okamoto M,
and
Adachi J.
Change in the electrical impedance caused by cornification of the epithelial cell layer of the vaginal mucosa in the rat.
Exp Anim
36:
151-156,
1987.
5.
Lilley, KG,
Epping RJ,
and
Hafner LM.
The guinea pig estrous cycle: correlation of vaginal impedance measurements with vaginal cytologic findings.
Lab Anim Sci
47:
632-637,
1997[Medline].
6.
Long, JA,
and
Evans HM.
The oestrous cycle in the rat and its associated phenomena.
Mem Univ California
6:
1-148,
1922.
7.
McClintock, MK.
Estrous synchrony and its mediation by airborne chemical communication (Rattus norvegicus).
Horm Behav
10:
264-276,
1978[Medline].
8.
McClintock, MK.
Estrous synchrony: modulation of ovarian cycle length by female pheromones.
Physiol Behav
32:
701-705,
1984[Medline].
9.
Petran, M.
An instrument for the measurement of tissue resistance in the brain during neurosurgical procedure.
Physiol Bohemoslov
1:
256-258,
1960.
10.
Senger, PL.
The estrus detection problem: new concepts, technologies and possibilities.
J Dairy Sci
77:
2745-2753,
1994[Abstract].
This article has been cited by other articles:
![]() |
J. L. Miles, K. Huber, N. M. Thompson, M. Davison, and B. H. Breier Moderate Daily Exercise Activates Metabolic Flexibility to Prevent Prenatally Induced Obesity Endocrinology, January 1, 2009; 150(1): 179 - 186. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. M. Thompson, A. M. Norman, S. S. Donkin, R. R. Shankar, M. H. Vickers, J. L. Miles, and B. H. Breier Prenatal and Postnatal Pathways to Obesity: Different Underlying Mechanisms, Different Metabolic Outcomes Endocrinology, May 1, 2007; 148(5): 2345 - 2354. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. M. Khan, M. Hadman, C. Wakade, L. M. De Sevilla, K. M. Dhandapani, V. B. Mahesh, R. K. Vadlamudi, and D. W. Brann Cloning, Expression, and Localization of MNAR/PELP1 in Rodent Brain: Colocalization in Estrogen Receptor-{alpha}- But Not in Gonadotropin-Releasing Hormone-Positive Neurons Endocrinology, December 1, 2005; 146(12): 5215 - 5227. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| Visit Other APS Journals Online |