Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 90: 1481-1488, 2001;
8750-7587/01 $5.00
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (9)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hamilton, D. R.
Right arrow Articles by Tyberg, J. V.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hamilton, D. R.
Right arrow Articles by Tyberg, J. V.
Vol. 90, Issue 4, 1481-1488, April 2001

Static and dynamic operating characteristics of a pericardial balloon

Douglas R. Hamilton, Gwyneth Devries, and John V. Tyberg

Departments of Medicine and Physiology/Biophysics, University of Calgary, Calgary, Alberta, Canada T2N 4N1


    ABSTRACT
TOP
ABSTRACT
INTRODUCTION
METHODS
RESULTS
DISCUSSION
APPENDIX A
APPENDIX B
REFERENCES

Previously, we developed a balloon transducer to measure the constraint of the pericardium (i.e., pericardial pressure) on the surface of the heart. It was validated physiologically in that it was shown to measure a pressure equal to the difference between the left ventricular end-diastolic pressure measured before and after pericardiectomy at the same left ventricular volume. To define its static operating characteristics, we loaded the balloon nonuniformly with weights that covered fractions of the balloon surface and found that the balloon accurately recorded the average stress if the stress was applied over at least 23% of its surface. To test its performance when curved, we placed it in large and small cylinders (minimum diameter 31 mm) and found that the balloon accurately recorded the stress. To define its dynamic operating characteristics, we applied sinusoidal stresses and found that its frequency response was limited only by that of the connecting catheter. When better dynamic response is required, we introduce a micromanometer-tipped catheter to obtain a unity-gain frequency response that is flat to 200 Hz.

pericardium; pericardial pressure; transducer; frequency response; epicardial stress


    INTRODUCTION
TOP
ABSTRACT
INTRODUCTION
METHODS
RESULTS
DISCUSSION
APPENDIX A
APPENDIX B
REFERENCES

A CENTURY AGO, Barnard (5) concluded that the pericardium is a significant constraint to filling of the heart. Many early investigators also observed that the parietal pericardium exerts a significant stress on the epicardium, but various transducers and catheters used to measure this constraint have yielded conflicting results (14, 17, 20, 24, 30).

Scalar terms such as "pressure" have been used to describe the stresses that the pericardium imposes on the epicardial surface. If one considers the tangential stress (shear stress) at the interface of these two structures to be minor, then the remaining radial stress might be considered to be scalar in nature, because the total vector stress on the epicardium will be normal to both surfaces, emulating liquid behavior over small elemental areas. The same situation can exist if a sufficient amount of liquid is present in the pericardial space to separate the epicardial and pericardial surfaces such that the distribution of radial stresses behaves hydrostatically (25).

Attempts have been made to measure pericardial pressure directly by using open-end catheters (4, 14, 20, 30), air-filled balloons (9, 17, 27), and liquid-filled balloons (12, 25). As measured by these devices, pericardial pressure has ranged from zero to nearly the cavitary pressure of the chamber being investigated, indicating the need for a standard in transducer design and calibration.

In 1985, Smiseth et al. (25) showed that pericardial pressure was strikingly dependent on the method of measurement used. They confirmed that the conventional open-ended catheters used to measure pericardial constraint in earlier studies registered a negligible pressure; however, they also showed that a balloon adapted from Holt et al. (12) recorded a hemodynamically significant pressure. (Since that time, the design and specifications of the balloon have not been changed.) The pressures measured from these flat balloons in surgical patients (7, 10, 29) were later shown to follow the blood volume-induced changes in right atrial pressure, in both direction and magnitude. As Tyberg et al. (28) originally proposed, the magnitude of pericardial constraint may be determined by comparing the (vertical) shift in the left ventricular (LV) end-diastolic pressure-volume relationships before and after pericardiectomy. This rationale for determining the true magnitude of pericardial constraint has been adopted by several other investigators (2, 3, 11).

The purpose of this investigation was to provide a systematic description of the fabrication technique and the static and dynamic operating characteristics of the balloon transducer used in several previous studies (6, 10, 15, 25, 29). In addition, we will describe a simple modification of the balloon that provides higher frequency response and fewer motion-induced artifacts.


    METHODS
TOP
ABSTRACT
INTRODUCTION
METHODS
RESULTS
DISCUSSION
APPENDIX A
APPENDIX B
REFERENCES

Balloon fabrication. The pericardial balloon is fabricated by using a 7 cm × 4 cm flat Silastic sheet (0.25 mm thick; compound AR131; Armet Industries, Concord, Ontario, Canada) wrapped around a 14-cm length of medical grade Silastic tubing (1.58 mm ID; 3.18 mm OD; Dow Corning, Midland, MI, catalogue no. 602-285). The tubing has three 2.0 mm × 1.5 mm holes, spaced 5.0 mm apart, cut into its side starting 7.5 mm from the end (see Fig. 1). The Silastic sheet is then wrapped around the tubing, and the opposing surfaces are bonded by using silicone adhesive (Dow Corning, catalog no. 891). The fabrication procedure is standardized by using a metal mold (schematic diagram available from the National Auxiliary Publications Service) that allows the balloon to be cured under slight pressure (10 mmHg). This method standardizes the internal volume and geometry. The opposing surfaces to be bonded are cured at 50°C for 24 h and then removed from the mold and left to stand at room temperature and out-gas for another 24 h. The edges of the balloon are trimmed to standard dimensions (30 mm × 30 mm; a smaller, 14- × 12-mm balloon has also been fabricated). The advantages of using Silastic sheets and silicone adhesive are the long shelf life after fabrication, nonreactivity to body tissues (8), flexibility, and resistance to fatigue and repetitive gas sterilizations. For most experiments, the balloon is attached to a length of 7-Fr angiographic catheter material, cut as short as convenient. Recently boiled room-temperature water is introduced into the balloon, and air bubbles are purged. Operating volumes range from 0.70 to 0.90 ml.


View larger version (16K):
[in this window]
[in a new window]
 
Fig. 1.   Schematic diagrams of the pericardial balloon. A, connecting tubing; B, transducing contact area (x × y); C, border (width = z) to prevent buckling; and D, side ports cut in tubing to communicate with balloon. For the balloon described in this study, x = 30, y = 30, and z = 5 mm. For atrial studies in large animals and for ventricular studies in cats and large-animal neonates, a smaller balloon (x = 12, y = 14, z = 5 mm) has also been fabricated.

To minimize distortion due to catheter motion and to increase frequency response, we introduce a 3-Fr micromanometer-tipped catheter (model PR-249 3F Mikro-tip catheter, Millar Instruments, Houston, TX) through the connecting catheter into the balloon (the micromanometer-tipped catheter remains within the connecting catheter, thus preventing exposure to direct compression). Because the micromanometer-tipped catheter is susceptible to baseline drift, the connecting catheter is also attached to a conventional strain-gauge pressure transducer (model P23 Db, Statham-Gould, Oxnard, CA), which allows an accurate measurement of mean pressure. The mean pressure of the micromanometer-tipped catheter is corrected to be equal to that measured through the 7-Fr catheter.

Static calibration: Uniform stress application. For convenience and reproducibility, we designed a compact balloon calibrator to apply stresses normal to the balloon surface using a thin, unstressed, compliant Silastic membrane (Fig. 2). The thin membrane (the same material used in the pericardial balloon) was attached to a Plexiglas cylinder (12.7 cm OD; 11.4 cm ID) so that it was unstressed but did not present any fold or redundancy to the balloon or to its supporting end plate. The other end of the cylinder was sealed with a Plexiglas end plate (15.2 cm, diameter; 1.27 cm, thickness). By placing the Silastic membrane over the pericardial balloon, which lay on the flat end plate, the desired configuration was achieved. The end plate was held against the thin membrane by use of three brass screws. A small trough was machined into the end plate, permitting passage of the tubing for connection to a pressure transducer. The pressure inside the calibrator could be manipulated and measured through a side port. Because the Plexiglas was clear, it was possible to observe the balloon to ensure its proper position. The end plate had several small holes drilled through its surface to allow air to escape. This ensured that the only stress applied to the balloon was through contact with the Silastic membrane and the supporting end plate. To permit testing under negative pressure, an alternate end plate was fabricated. This end plate had only one hole, which allowed air to escape during positive pressurization; the hole was then sealed and the pressure in the test chamber was lowered to expose the balloon to negative stresses. Details of the calibration procedure are given in APPENDIX A.


View larger version (32K):
[in this window]
[in a new window]
 
Fig. 2.   Exploded-parts view of the static balloon calibration device showing the Plexiglas pressure chamber (A), Silastic membrane (B), membrane support ring (C), and balloon support disk (D).

Static calibration: Nonuniform stress application. A benchtop experiment was performed to investigate whether the pericardial balloon would accurately record an average stress, even if the load had been applied nonuniformly. The effects of nonuniform loading were examined by placing rectangular blocks of different areas (1.0, 2.1, 4.0, 6.1, and 8.0 cm2) at the center of the balloon's transducing contact surface (see Fig. 1) while the balloon was lying on a flat surface. These blocks were loaded with weights that were adjusted to apply identical stresses (i.e., force per area of the block). Arbitrarily, we chose stresses equal to 18 mmHg (23,940 dynes/cm2 = 24.4 gm/cm2) and 32 mmHg (42,560 dynes/cm2 = 43.4 gm/cm2). For example, to achieve a stress equivalent to 32 mmHg, the 2.1 cm2 block was loaded with 91.1 (43.4 × 2.1) gm, the 4.0 cm2 block was loaded with 173.6 (43.4 × 4.0) gm, and so on. The pressures measured by the balloon were plotted against the areas of the blocks when so loaded. If the measured pressure was proportional to the area of the balloon surface that was covered by the loaded block, it was concluded that the balloon had spatially integrated (i.e., averaged) the applied stress appropriately.

Static calibration: Stress applied over a curved surface. Bending a balloon might introduce Laplacian stresses on the membranes, thereby exaggerating the recorded pericardial pressure. The calibration was verified by placing the pericardial balloon within different Plexiglas cylinders (internal diameters 31, 38, and 50 mm) and inflating a thin-walled cylindrical balloon (i.e., a condom) to compress it against the inside wall of the cylinder (see Fig. 3). The surfaces were flushed with water, and the condom was inflated to different measured pressures. According to the pleural-pressure measurement technique developed by Lai-Fook et al. (16, 31), the stress that the condom exerted on the inner surface of the cylinder was measured by use of a pressure transducer (Model P23 Db, Statham-Gould) connected by a liquid-filled tubing to a hole in the wall of the cylinder at the same hydrostatic level as the pericardial balloon. The pressure measured by the pericardial balloon was compared with the condom pressure and that measured by the wall transducer. Later, the unconstrained condom was inflated and the distending pressure was plotted as a function of condom diameter (measured using vernier calipers), to allow estimation of the transmural pressures required to achieve condom diameters equal to the inside diameters of the cylinders.


View larger version (27K):
[in this window]
[in a new window]
 
Fig. 3.   Schematic diagrams of the curved-surface calibration apparatus. A cylindrical balloon (condom) was inflated within Plexiglas cylinders of 31, 38, or 50 mm ID. After all surfaces were moistened with water, the pericardial balloon was placed between condom and cylinder and, on the opposite side, a liquid-filled tubing was connected to a pressure transducer. Pressures recorded by using the pericardial balloon and the liquid-filled tubing were compared with the inflation pressure.

Dynamic calibration. To determine the balloon's frequency response, we constructed a dynamic calibration chamber using a high-fidelity speaker (model SW6025G Alpha Sub-Woofer, Heco-Hennel and, Germany). The speaker was driven by two 100-W, direct-current coupled amplifiers arranged in a class-B push-pull configuration (model SM-100, OPAMP Labs, Los Angeles, CA), which amplified a sinusoidal input signal (model 180 LF sweep generator, Wavetek, San Diego, CA). The static calibrator was modified to accommodate the speaker, which imposed a time-varying pressure onto the membrane overlying the pericardial balloon (schematic diagram available from the National Auxiliary Publications Service). The oscillating chamber pressure was measured by using a micromanometer-tipped catheter (model PR-279 8F Mikro-tip, Millar Instruments) introduced through a side port. The signal from the sweep generator was compared with the pressure measured in the chamber by using specially designed circuitry to create an error signal that was used for negative feedback to the power amplifier of the speaker. This sinusoidal pressure-generating system kept total harmonic distortion of the chamber-pressure waveform to <5% over frequencies ranging from 2 to 200 Hz (peak sinusoidal pressures up to 20 mmHg). The calibration chamber was designed to be pressurized to 60 mmHg (i.e., the mean chamber pressure could be 40 mmHg on which a ±20 mmHg sinusoidal pressure could be modulated). To measure the stresses effectively being imposed on the balloon by the membrane, a load cell (diaphragm diameter 25 mm; model P23-BB venous pressure transducer, Statham, Hato Rey, Puerto Rico) was placed flush with the surface of the balloon-support end plate, immediately beneath the position to be occupied by the balloon. The load-cell output was also measured with the balloon in place to assess the dynamic effect of the presence of the balloon. If the relation of chamber pressure to load-cell "pressure" (i.e., stress) was unaffected by the presence of the balloon, it was concluded that the balloon did not alter the dynamic characteristics of the system and balloon pressure would track chamber and load-cell pressures. The pressure recorded from the balloon and that from the load cell were compared with the chamber pressure in terms of amplitude and phase lag.


    RESULTS
TOP
ABSTRACT
INTRODUCTION
METHODS
RESULTS
DISCUSSION
APPENDIX A
APPENDIX B
REFERENCES

Static calibration: Uniform stress application. More than 90% of the balloons fabricated using the mold were found to pass the static calibration procedures. A typical calibration plot is shown in Fig. 4, which illustrates the linearity of these devices. The difference between the calibrator and balloon pressure never exceeded 1 mmHg over the range of pressures. When properly calibrated, 10 mold-fabricated balloons were found to have volumes of 0.775 ± 0.054 ml (means ± SD) at which they were unstressed.


View larger version (26K):
[in this window]
[in a new window]
 
Fig. 4.   Pericardial balloon pressure vs. static calibration chamber pressure. The calibration chamber pressure was varied from -40 to +50 mmHg. A linear balloon response is indicated. This balloon contained 0.85 ml of water.

Static calibration: Nonuniform stress application. Figure 5 shows the results of the nonuniform loading test. When rectangular blocks of different sizes were loaded with weights such that stresses equivalent to 32 or 18 mmHg were applied, the pressures recorded from the balloon were proportional to the areas of the blocks. When a block smaller than 23% of the transducing contact surface (e.g., 11%) was used, the balloon underestimated the applied stress. However, the balloon transducer accurately recorded the average stress when that stress was applied over at least 23% (2.1/9.0) of its transducing contact surface.


View larger version (14K):
[in this window]
[in a new window]
 
Fig. 5.   Results of nonuniform loading experiment. Balloon pressure is plotted vs. the percent area of the balloon covered by rectangular blocks (1.0, 2.1, 4.0, 6.1, and 8.0 cm2) placed at the center of the balloon, each loaded to a stress (force/area of the block) equivalent to 32 (circles) or 18 (triangles) mmHg. Because (except for the smallest block) all the recorded pressures were proportional to the areas, we concluded that the balloon spatially integrated (averaged) the applied stress appropriately when stress was applied over at least 23% (2.1/9.0) of the total area.

Static calibration: Stress applied over a curved surface. Figure 6 shows that, when the pericardial balloon was placed within cylinders of various sizes, the recorded pressure increased 1:1 with the inflation pressure of the condom. The X-axis offset can be approximately accounted for by the fact that the unconstrained condom required pressure to attain the diameters of the cylinders: 1, 5, and 10 mmHg for the 31-, 38-, and 50-mm cylinders, respectively. The figure also shows that the balloon recorded a pressure that was equal to that recorded through an open side hole at the same level (16). These results confirm that the pericardial balloon measures radial stress accurately when confined within spaces with radii of curvature similar to the pericardial space. (Although there is an unexplained ~1 mm difference between pressures recorded using the balloon and the side hole when the 50-mm cylinder was used, we concluded that this did not represent an effect of curvature because it only occurred in the largest cylinder.)


View larger version (27K):
[in this window]
[in a new window]
 
Fig. 6.   Effects of radius of curvature on balloon calibration. Using the apparatus shown in Fig. 3, we compared the pressures recorded by using the pericardial balloon (filled symbols, solid line) and the liquid-filled tubing (open symbols, dashed line) with the inflation pressure of the condom when using cylinders of 31 (circles), 38 (triangles), or 50 (squares) mm ID. The condoms required pressures of 1, 5, and 10 mmHg (note x-intercepts) to achieve diameters of 31, 38, and 50 mm. We concluded that, if the balloon is placed on a 1-dimensionally curved surface with a radius of curvature as small as 15.5 mm, it still measures contact stress accurately.

Dynamic calibration. In Fig. 7 (top), the amplitude ratio (pericardial balloon pressure/chamber pressure) is plotted against the frequency of the sinusoidal input function. A typical second-order, underdamped response with a peak resonance and a 180° phase shift at ~25 Hz is seen (the falloff was linear when amplitude ratio and frequency were plotted on logarithmic scales). Because there was always a 1:1 relationship between the chamber pressure and the load-cell "pressure" (data not shown), it was clear that the calibrator membrane did not modify the time-varying chamber pressure. The frequency response of the 7-Fr catheter itself (data not shown) was also determined and found to be virtually identical to that of the pericardial balloon. Because the frequency response of the high-fidelity balloon was flat to 200 Hz (only data to 100 Hz shown), we concluded that the limitation in the frequency response of the pericardial balloon was determined by the catheter. As shown in Fig. 7, bottom, the phase response for the pericardial balloon shifted from 0 to 180°. Typical of a second-order resonant system, a 90° phase shift occurred at the frequency at which there was maximum resonance.


View larger version (16K):
[in this window]
[in a new window]
 
Fig. 7.   Dynamic calibrations of the regular and high-fidelity pericardial balloons. Top: amplitude ratio (pericardial balloon pressure/chamber pressure) is plotted against frequency of the sinusoidal input function. For the regular balloon (larger circles), a typical second-order, underdamped response with a peak resonance at ~25 Hz is seen (the falloff is linear when plotted log-log). For the high-fidelity balloon (smaller circles), the amplitude ratio is ~1 at all frequencies <100 Hz. Bottom: phase response for the regular pericardial balloon shifted from 0 to 180° with a phase shift of 90° corresponding to the peak resonance. Over this frequency range, there was no phase shift when using the high-fidelity balloon (data not shown).


    DISCUSSION
TOP
ABSTRACT
INTRODUCTION
METHODS
RESULTS
DISCUSSION
APPENDIX A
APPENDIX B
REFERENCES

The simple tests reported in this paper demonstrate that the pressure recorded from a flat, liquid-filled, pericardial balloon transducer accurately reflects the stress applied to its surface. This is true not only when a static stress is applied uniformly to the balloon but also when the stress is applied over as little as 23% of its area. It is also true when the balloon is deformed by placing it on a surface more curved than the free wall of the canine LV. Although the frequency response of the standard balloon transducer is limited by that of the connecting catheter, the standard balloon can be modified by inserting a micromanometer-tipped catheter inside the balloon, extending its frequency response to 200 Hz, and reducing its susceptibility to catheter motion-induced artifacts. Therefore, in addition to the fact that the balloon transducer records a pressure equal to the constant-volume shift in LV end-diastolic pressure (28), these results indicate that there is no reason to doubt that the balloon transducer can be used to measure epicardial radial stress (i.e., "pericardial pressure") reliably throughout the cardiac cycle.

Although we and others have filled pericardial balloons with water or saline (7, 12), other pericardial investigators have filled their balloons with air (3, 11, 24), following the precedent of those who used balloons to measure pleural or esophageal pressure (13, 19). Any fluid (air, water, oil, etc.) can be used, but, because of compressibility, air-filled balloons perform somewhat less well than water-filled balloons in terms of nonuniform loading and, because of viscosity, oil-filled balloons perform less well in terms of frequency response (data not shown). However, as discussed in detail in APPENDIX B, liquids with bloodlike specific gravities are very advantageous because they allow accurate assessments of transmural pressure, regardless of the position of the balloon.

Conventional static calibration techniques (18) load the balloon with a uniform stress distribution. We developed a more rigorous test in which loading was applied nonuniformly, probably much less uniformly than could occur within the pericardium. We applied equal, known stresses over varying fractions of the transducing surface of the balloon. We reasoned that, if a given stress were applied over half the surface, for example, the proper response would be one-half the pressure that would be registered if that same stress had been applied uniformly over the entire surface. We found that the balloon performed this spatial integration very well, probably because of its construction. The loaded rectangular block would have caused Laplacian stresses to develop in both surfaces. If those stresses had not been opposed, a pressure less than the predicted pressure would have been recorded from the balloon. Because the measured pressure was equal to the predicted pressure, those Laplacian stresses must have been opposed by the rigidity of the borders of the balloon, which caused pressure to increase to the predicted level. [The borders of a pericardial balloon must be rigid enough so they resist the buckling that would tend to occur because of the tension in the Silastic membranes created by nonuniform loads, yet be thin enough to be flexible (1, 18).]

It has been suggested that, because of the curvature of the LV surface, the balloon must record an artifactually high pressure, even though it had been calibrated to be accurate when flat (21). The surface of the LV is hemiellipsoidal and, therefore, curved in two directions. We made several attempts to create a test chamber with an elliptical surface. However, we abandoned the effort because we were unable to specify the applied stress unequivocally, because of the complexity of the stresses. We then chose an alternative strategy: to demonstrate that the balloon performed accurately in a cylindrical calibrator with a relatively extreme (albeit one-dimensional) curvature in which the imposed stresses could be defined (16). We observed that the balloon was accurate even in the cylinder with the smallest radius of curvature; 15.5 mm is less than either the short- or long-axis radius of curvature of the LV free wall of a 20-kg dog and much less than those dimensions in the adult human. Thus we conclude that there is no significant error due to curvature when the balloon transducer is used to measure pericardial pressure over the LV free wall.

Predictably, we found that the frequency response of the standard pericardial balloon was not better than that of the connecting 7-Fr catheter. Figure 7 indicates that the 20-Hz component of the pressure waveform was approximately doubled in magnitude. We also evaluated the output of the high-fidelity balloon to assess the frequency response required to measure the fastest events in the cardiac cycle (i.e., the early systolic peak approximately coinciding with the c wave). Using low-pass digital filters with sharp cutoffs, we filtered the pericardial pressure recorded from a dog with a heart rate of 94 min-1 and evaluated the attenuation of the peak. Excluding frequencies above 40, 30, 20, and 10 Hz (equivalent to excluding harmonics greater than ~25, 19, 13, and 6) resulted in respective attenuations of 2, 7, 24, and 44% (see Fig. 8). Because pericardial pressure does not change rapidly at end diastole, that pressure was not changed by even 10-Hz filtering and, thus, we conclude that the frequency response of the standard pericardial balloon transducer is sufficient to measure end-diastolic transmural pressure accurately. However, when faster events are to be studied, the high-fidelity adaptation of the transducer is satisfactory and convenient.


View larger version (21K):
[in this window]
[in a new window]
 
Fig. 8.   Left ventricular (LV; manometer-tipped catheter) and pericardial pressures (manometer-tipped catheter; i.e., the high-fidelity balloon). To estimate the frequency response required for accurate measurement of pericardial pressure at different times during the cycle, pressure was filtered by using digital low-pass filters with cutoff frequencies of 40, 30, 20, and 10 Hz. Pericardial pressure at end-diastole (vertical line) can be measured accurately by the conventional balloon, in that filtering the output of the manometer-tipped catheter to 10 Hz did not alter the end-diastolic value. However, to measure the high-frequency, early systolic peak in pericardial pressure accurately, the high-fidelity balloon is required (unfiltered pressure, 4.56; 40-Hz filter, 4.52; 30-Hz filter, 4.34; 20-Hz filter, 4.12; and 10-Hz filter, 3.77 mmHg).

In addition to allowing the study of faster events, the insertion of a micromanometer-tipped catheter into the balloon minimizes motion-induced artifacts (i.e., "catheter-whip"). Although the connecting catheter might still generate such artifacts, the micromanometer in the balloon will not detect them because the mechanical impedance of the balloon is very low. We were able to demonstrate that "artifacts" generated in the catheter by tapping, which were conspicuous when measured using the external transducer, were undetectable using the micromanometer-tipped catheter. The problem of micromanometer baseline instability can be overcome by recording pressure through the lumen and adjusting the mean values to be equal either manually, before the data are recorded, or retrospectively, during analysis, as we did.

In conclusion, we have performed static and dynamic calibrations of a Silastic, liquid-filled, pericardial balloon transducer. Static performance was satisfactory, even when loading was markedly nonuniform or when the balloon was curved. Dynamic performance was limited only by the transmission characteristics of the connecting catheter. When higher frequency response is required or motion-induced artifacts are to be minimized, a convenient high-fidelity modification is available.


    APPENDIX A. DETERMINATION OF BALLOON VOLUME
TOP
ABSTRACT
INTRODUCTION
METHODS
RESULTS
DISCUSSION
APPENDIX A
APPENDIX B
REFERENCES

Recently boiled room-temperature water is introduced into the balloon, and all air bubbles are purged. The balloon is positioned in the calibration chamber, and chamber pressure is increased to 5 mmHg to expel the free air from the space between the membrane and the end plate. The calibration chamber pressure is then returned to atmospheric pressure. Zero balloon volume is established when liquid is withdrawn until the balloon surfaces form a dimple over the side ports of the internal tubing (suction of approximately -5 mmHg is required for this to occur). The chamber pressure is increased to ~30 mmHg, and the volume of liquid introduced into the balloon is adjusted until the balloon pressure equals the chamber pressure within ±0.5 mmHg. The balloon volume is fixed at the value determined by the previous step, and balloon error is measured over chamber pressures ranging from -40 to +50 mmHg. If the balloon error is found to be >1 mmHg, the balloon is considered flawed and is discarded.


    APPENDIX B. COMPARISON OF AIR- AND LIQUID-FILLED BALLOONS
TOP
ABSTRACT
INTRODUCTION
METHODS
RESULTS
DISCUSSION
APPENDIX A
APPENDIX B
REFERENCES

Assuming that blood has a specific gravity of 1 gm/cm3, that the hydrostatic equivalent of LV diameter is equal to 4 mmHg (5.44 cmH2O = 4 mmHg) and that the true transmural LV end-diastolic pressure is 2 mmHg at every point on its circumference, Fig. 9 shows that air- and liquid-filled balloons yield different values of transmural pressure, depending on the position of the balloon. If absolute LV intracavitary pressure is assumed to be 10 mmHg at the mid-LV reference plane, the absolute pressure must be 8 mmHg at the top of the cavity and 12 mmHg at the bottom, because of the weight of the blood. An air-filled balloon at the top of the LV (A in Fig. 9) would record 6 (8 - 2) mmHg, at the midplane (B) 8 (10 - 2) mmHg, and at the bottom (C) 10 (12 - 2) mmHg. On the other hand, a liquid-filled balloon would record 8 mmHg at every location. This is because the siphon effect of the column of water contained in the connecting catheter automatically adds or subtracts an appropriate hydrostatic correction after the transducer has been zeroed at the mid-LV reference plane. Because it is difficult to ascertain the position of the balloon precisely and at all times, it is difficult to correct the measurements from an air-filled balloon and, thus, to achieve accurate estimations of transmural pressure at any time in the cardiac cycle.


View larger version (28K):
[in this window]
[in a new window]
 
Fig. 9.   Comparison of air- and liquid-filled balloons in terms of assessing transmural pressure (Ptm). The schematic diagram shows the position of balloons placed above (A), beside (B), or below (C) the LV. Assuming that LV intracavitary pressure is 10 mmHg at the level of the mid-LV reference plane, the table shows that the air-filled balloon would give three different estimates of LV Ptm depending on balloon position. However, because of the hydrostatic effect of the liquid-filled catheter, measurements from a liquid-filled balloon would yield the same Ptm from any position. Pp, pericardial pressure.


    ACKNOWLEDGEMENTS

We thank Cheryl Meek, Rozsa Sas, and Gerald Groves for technical assistance and Dr. I. Belenkie for criticism. Dr. Jiun-Jr Wang provided frequency-response analysis of pericardial pressure.


    FOOTNOTES

The study was supported by operating grants from the Alberta Heart and Stroke Foundation (Calgary, Alberta) to J. V. Tyberg. J. V. Tyberg is a Medical Scientist of the Alberta Heritage Foundation for Medical Research (Edmonton, Alberta), which also supported the study with an Establishment Grant.

Address for reprint requests and other correspondence: J. V. Tyberg, Medicine and Physiology/Biophysics, Univ. of Calgary Health Sciences Centre, 3330 Hospital Dr. NW, Calgary, Alberta, Canada T2N 4N1 (E-mail: jtyberg{at}ucalgary.ca).

The costs of publication of this article were defrayed in part by the payment of page charges. The article must therefore be hereby marked "advertisement" in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.

Received 18 February 2000; accepted in final form 22 November 2000.


    REFERENCES
TOP
ABSTRACT
INTRODUCTION
METHODS
RESULTS
DISCUSSION
APPENDIX A
APPENDIX B
REFERENCES

1.   Agostoni, E. Mechanics of the pleural space. Physiol Rev 52: 57-128, 1972[Free Full Text].

2.   Applegate, RJ, Santamore WP, Klopfenstein HS, and Little WC. External pressure of undisturbed left ventricle. Am J Physiol Heart Circ Physiol 258: H1079-H1086, 1990[Abstract/Free Full Text].

3.   Assanelli, D, Lew WYW, Shabetai R, and LeWinter MM. Influence of the pericardium on right and left ventricular filling in the dog. J Appl Physiol 63: 1025-1032, 1987[Abstract/Free Full Text].

4.   Banchero, N, Schwartz PE, Tsakiris AG, and Wood EH. Pleural and esophageal pressures in the upright body position. J Appl Physiol 23: 228-234, 1967[Free Full Text].

5.   Barnard, HL. The functions of the pericardium. J Physiol (Lond) 22: 43-47, 1898.

6.   Belenkie, I, Dani R, Smith ER, and Tyberg JV. Ventricular interaction during experimental acute pulmonary embolism. Circulation 78: 761-768, 1988[ISI][Medline].

7.   Boltwood, CM, Skulsky A, Drinkwater DC, Lang S, Mulder DG, and Shah PM. Intraoperative measurement of pericardial constraint: role in ventricular diastolic mechanics. J Am Coll Cardiol 8: 1289-1297, 1986[Abstract].

8.   Boyd, IA, and Pathak CL. The comparative toxicity of silicone rubber and plastic tubing. Scott Med J 9: 345-351, 1964[Medline].

9.   Freeman, GL, and LeWinter MM. Determinants of intrapericardial pressure in dogs. J Appl Physiol 60: 758-764, 1986[Abstract/Free Full Text].

10.   Hamilton, DR, Dani RS, Semlacher RA, Smith ER, Kieser TM, and Tyberg JV. Right atrial and right ventricular transmural pressures in dogs and humans. Effects of the pericardium. Circulation 90: 2492-2500, 1994[ISI][Medline].

11.   Hoit, BD, Dalton N, Bhargava V, and Shabetai R. Pericardial influences on right and left ventricular filling dynamics. Circ Res 68: 197-208, 1991[Abstract].

12.   Holt, JP, Rhode EA, and Kines H. Pericardial and ventricular pressure. Circ Res 8: 1171-1180, 1960[Abstract].

13.   Hoppin, FG, Green ID, and Mead J. Distribution of pleural surface pressure in dogs. J Appl Physiol 27: 863-873, 1969[Free Full Text].

14.   Kenner, HM, and Wood EH. Intrapericardial, intrapleural, and intracardiac pressures during acute heart failure in dogs studied without thoracotomy. Circ Res 19: 1071-1079, 1966[Abstract].

15.   Kingma, I, Smiseth OA, Frais MA, Smith ER, and Tyberg JV. Left ventricular external constraint: relationship between pericardial, pleural and esophageal pressures during positive end-expiratory pressure and volume loading in dogs. Ann Biomed Eng 15: 331-346, 1987[ISI][Medline].

16.   Lai-Fook, SJ, Price DC, and Staub NC. Liquid thickness vs. vertical pressure gradient in a model of the pleural space. J Appl Physiol 62: 1747-1754, 1987[Abstract/Free Full Text].

17.   Mann, D, Lew W, Ban-Hayashi E, Shabetai R, Waldman L, and LeWinter MM. In vivo mechanical behavior of canine pericardium. Am J Physiol Heart Circ Physiol 251: H349-H356, 1986.

18.   McMahon, SM, Permutt S, and Proctor DF. A model to evaluate pleural surface pressure measuring devices. J Appl Physiol 27: 886-891, 1969[Free Full Text].

19.   Milic-Emili, J, Mead J, Turner JM, and Glauser EM. Improved technique for estimating pleural pressure from esophageal balloons. J Appl Physiol 19: 207-211, 1964[Abstract/Free Full Text].

20.   Morgan, BC, Guntheroth WG, and Dillard DH. Relationship of pericardial to pleural pressure during quiet respiration and cardiac tamponade. Circ Res 16: 493-498, 1965[Abstract].

21.   Nakamoto, T, Li K, Santamore WP, and Johnston WE. Inherent sensitivity of pericardial balloon catheters to surface curvature (Abstract). FASEB J 3: A1174, 1989.

22.   Scott-Douglas, NW, Traboulsi M, Smith ER, and Tyberg JV. Experimental instrumentation and left ventricular pressure-strain relationship. Am J Physiol Heart Circ Physiol 261: H1693-H1697, 1991[Abstract/Free Full Text].

23.   Shabetai, R. Measuring pericardial constraint. J Am Coll Cardiol 7: 315-316, 1986[ISI][Medline].

24.   Shabetai, R. Pericardial and cardiac pressure. Circulation 77: 1-5, 1988[ISI][Medline].

25.   Smiseth, OA, Frais MA, Kingma I, Smith ER, and Tyberg JV. Assessment of pericardial constraint in dogs. Circulation 71: 158-164, 1985[ISI][Medline].

26.   Smiseth, OA, Refsum H, and Tyberg JV. Pericardial pressure assessed by right atrial pressure: a basis for calculation of left ventricular transmural pressure. Am Heart J 108: 603-605, 1983.

27.   Takata, M, Mitzner W, and Robotham JL. Influence of the pericardium on ventricular loading during respiration. J Appl Physiol 68: 1640-1650, 1990[Abstract/Free Full Text].

28.   Tyberg, JV, Misbach GA, Glantz SA, Moores WY, and Parmley WW. A mechanism for the shifts in the diastolic, left ventricular, pressure-volume curve: the role of the pericardium. Eur J Cardiol Suppl 7: 163-175, 1978.

29.   Tyberg, JV, Taichman GC, Smith ER, Douglas NWS, Smiseth OA, and Keon WJ. The relation between pericardial pressure and right atrial pressure: an intraoperative study. Circulation 73: 428-432, 1986[ISI][Medline].

30.   Tyson, GSJ, Maier GW, Olsen CO, Davis JW, and Rankin JS. Pericardial influences on ventricular filling in the conscious dog: an analysis based on pericardial pressure. Circ Res 54: 173-184, 1984[Abstract].

31.   Wiener-Kronish, JP, Gropper MA, and Lai-Fook SJ. Pleural liquid pressure in dogs measured using a rib capsule. J Appl Physiol 59: 597-602, 1985[Abstract/Free Full Text].


J APPL PHYSIOL 90(4):1481-1488
8750-7587/01 $5.00 Copyright © 2001 the American Physiological Society



This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
T. N. Hobson, J. A. Flewitt, I. Belenkie, and J. V. Tyberg
Wave intensity analysis of left atrial mechanics and energetics in anesthetized dogs
Am J Physiol Heart Circ Physiol, March 1, 2007; 292(3): H1533 - H1540.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
C. A. Gibbons Kroeker, S. Adeeb, J. V. Tyberg, and N. G. Shrive
A 2D FE model of the heart demonstrates the role of the pericardium in ventricular deformation
Am J Physiol Heart Circ Physiol, November 1, 2006; 291(5): H2229 - H2236.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
J. R. Mitchell, W. A. Whitelaw, R. Sas, E. R. Smith, J. V. Tyberg, and I. Belenkie
RV filling modulates LV function by direct ventricular interaction during mechanical ventilation
Am J Physiol Heart Circ Physiol, August 1, 2005; 289(2): H549 - H557.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
Z. Wang, F. Jalali, Y.-H. Sun, J.-J. Wang, K. H. Parker, and J. V. Tyberg
Assessment of left ventricular diastolic suction in dogs using wave-intensity analysis
Am J Physiol Heart Circ Physiol, April 1, 2005; 288(4): H1641 - H1651.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
D. R. Hamilton, R. Sas, and J. V. Tyberg
Atrioventricular nonuniformity of pericardial constraint
Am J Physiol Heart Circ Physiol, October 1, 2004; 287(4): H1700 - H1704.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
E. H. Hollander, G. M. Dobson, J.-J. Wang, K. H. Parker, and J. V. Tyberg
Direct and series transmission of left atrial pressure perturbations to the pulmonary artery: a study using wave-intensity analysis
Am J Physiol Heart Circ Physiol, January 1, 2004; 286(1): H267 - H275.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
C. A. G. Kroeker, N. G. Shrive, I. Belenkie, and J. V. Tyberg
Pericardium modulates left and right ventricular stroke volumes to compensate for sudden changes in atrial volume
Am J Physiol Heart Circ Physiol, June 1, 2003; 284(6): H2247 - H2254.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
T. D. Moore, M. P. Frenneaux, R. Sas, J. J. Atherton, J. A. Morris-Thurgood, E. R. Smith, J. V. Tyberg, and I. Belenkie
Ventricular interaction and external constraint account for decreased stroke work during volume loading in CHF
Am J Physiol Heart Circ Physiol, December 1, 2001; 281(6): H2385 - H2391.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
G. deVries, D. R. Hamilton, H. E. D. J. Ter Keurs, R. Beyar, and J. V. Tyberg
A novel technique for measurement of pericardial pressure
Am J Physiol Heart Circ Physiol, June 1, 2001; 280(6): H2815 - H2822.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (9)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hamilton, D. R.
Right arrow Articles by Tyberg, J. V.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hamilton, D. R.
Right arrow Articles by Tyberg, J. V.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online