|
|
||||||||
1 Biomedical Research Department, Navy Experimental Diving Unit, Panama City, Florida 32407-7015; and 2 Diving and Environmental Physiology Department, Naval Medical Research Institute, Bethesda, Maryland 20889-5607
| |
ABSTRACT |
|---|
|
|
|---|
A mixed-gas model for rats was developed to further explore the role of
different gases in decompression and to provide a global model for
possible future evaluation of its usefulness for human prediction. A
Hill-equation dose-response model was fitted to over 5,000 rat dives by
using the technique of maximum likelihood. These dives used various
mixtures of He, N2, Ar, and O2 and had times at
depth up to 2 h and varied decompression profiles. Results
supported past findings, including 1) differences among the
gases in decompression risk (He < N2 < Ar) and
exchange rate (He > Ar
N2), 2)
significant decompression risk of O2, and 3) increased risk of decompression sickness with heavier animals. New
findings included asymmetrical gas exchange with gas washout often
unexpectedly faster than uptake. Model success was demonstrated by the
relatively small errors (and their random scatter) between model
predictions and actual incidences. This mixed-gas model for prediction
of decompression sickness in rats is the first such model for any
animal species that covers such a broad range of gas mixtures and dive profiles.
diving; hyperbaric; inert gases; mathematical modeling
| |
INTRODUCTION |
|---|
|
|
|---|
DURING THE LAST DECADE, DEVELOPMENT of human decompression procedures has been significantly aided by the use of probabilistic models for predicting decompression sickness (DCS; Ref. 25). By using techniques such as maximum likelihood, the probability of DCS can be expressed as a continuous function that includes variables such as depth, gas composition, and decompression profile. Unfortunately, although DCS is assumed to result from an excess of inert gas somewhere in the body, little is known about the properties of gases under high pressure in tissues (26) or about how bubbles develop and presumably lead to DCS (5, 23). Consequently, probabilistic modeling has generally been done empirically by fitting functions to a set of dives that allow risk prediction but have little, if any, physiological basis. As a result, most human predictive models do not extrapolate reliably to dive profiles much different from the original data, particularly to those that have high risk.
Use of animals offers the potential to improve prediction of DCS in humans. Large numbers of animal dives can be performed relatively easily and inexpensively over a broad range of DCS incidence rates. These data are often more suitable for modeling decompression risk than human data containing relatively few cases of DCS. However, much animal research has focused on investigating the pathophysiology of DCS or addressing basic scientific questions such as the role of bubbles in DCS rather than on helping to estimate human risk of DCS. Exceptions to this include the early use of goats to help develop decompression procedures for humans (4). A next major step is to develop a formal procedure for using animal decompression outcome to help predict human DCS.
Modeling efforts in our laboratory with small animals have demonstrated that prediction of risk of DCS can be improved by accounting for differences among gases in terms of 1) "relative potency" (RP), which defines the level of decompression risk on a per-unit-pressure basis, and 2) gas exchange rates (12-15). These previous models have generally dealt with specific types of dives such as saturation, gas switching, or dives with variable decompression. This report describes the next step of combining the different data sets and developing one general mixed-gas model for prediction of DCS in rats over a wide range of dive profiles with various mixtures of He, N2, Ar, and O2.
We believe that this is the first attempt to construct a model of such scope in terms of gases and types of dives. The rationale behind our work was that such a model should provide additional information about the role of different gases in decompression, thus increasing our understanding of the mechanisms of DCS. The hypothesis for this study was that such a model could be produced that would allow reliable predictions without significant bias with regard to the exact dive profile. This work was not done in anticipation of an increased use of mixed-gas diving in the US Navy. However, our work does provide a global model for possible future evaluation of its usefulness for human prediction. Recently, a similar effort using animal decompression outcome to predict human DCS was begun with sheep (2).
| |
METHODS |
|---|
|
|
|---|
Hill-equation dose-response models were fitted by the technique of maximum likelihood to a database of over 5,000 rat dives created by combining five sets of dives with very different profiles that were conducted over the last decade at the Naval Medical Research Institute (NMRI). The first four sets (data sets 1-4) had been analyzed separately earlier and previously reported (12-15); a fifth set (data set 5) represents new data that have not been modeled or described before. These dives, using various mixtures of He, N2, Ar, and O2, had times at depth up to 2 h and varied decompression profiles. A general mixed-gas model for prediction of decompression risk in rats was produced.
Animal Use
The experimental animal protocols for all the four past sets of experiments as well as for the new previously unreported data (data set 5) were reviewed and approved by the in-house Animal Care and Use Committee at NMRI before any experiments. The Committee used the animal use guidance required at the time of review by the Department of the Navy, which was the current version of the "Guide for the Care and Use of Laboratory Animals," Institute of Laboratory Animal Resources, National Research Council, DHHS publ. nos. (NIH) 78-23, 85-23, 86-23.Animal numbers were one of many details carefully reviewed by the NMRI committee, and statistical justification was required to support all animal requests. In the case of decompression modeling, large numbers of dives are often required to produce parameter estimates with the precision needed to resolve differences in risk or gas exchange. Discussion regarding selection of the specific number of animals used is contained in some of the past reports (12-15). Similar studies involving large numbers of rodents continue to be approved at NMRI, as evidenced by the most recently conducted experiments comparing the decompression risk of He and H2 (16).
Data Used for Modeling
The five sets of rat dives used in model development are summarized in Table 1.
|
Experimental Protocols
Our experimental procedures for conducting decompression experiments with rats have been described previously (12-15). Therefore, only a brief general discussion of the methods is provided here, followed by a more detailed description of procedures associated with data set 5, which has not been previously reported and thus needs to be described.Male albino rats (Rattus norvegicus, Sprague-Dawley strain) weighing ~200-300 g were obtained from a local supplier and housed in the Institute's animal care facility for at least 1 wk before use. The animals were allowed access to food and water up until immediately before the dive began.
General diving procedures. Five animals were placed in a cylindrical cage, which was then loaded into a small-animal hyperbaric chamber. The chamber was compressed at a rate of 1.8 atmospheres absolute (ATA)/min to depth. Gas mixtures were made by serially adding air, O2, or one of the inert gases (N2, He, or Ar) during compression, with the precise amounts depending on the intended composition. For dives in which N2 was to be absent in the dive mixture, the chamber was flushed with an appropriate amount of O2 over a 5-min period before compression to remove all N2 (13).
The composition of the chamber atmosphere was analyzed when final depth was first reached and at 10- to 15-min intervals thereafter at depth. A Beckman F3 paramagnetic O2 analyzer and a Beckman 865 infrared CO2 analyzer (Fullerton, CA) were used for O2 and CO2 analysis, respectively. The inert gases were measured by use of a UTI 100C mass spectrometer (Uthe Technology International, Sunnyvale, CA). Chamber temperature was kept at 28.0 ± 0.5°C throughout the exposure by means of a temperature controller (Yellow Springs Instrument, Yellow Springs, OH). Animals were kept at depth for up to 2 h and then decompressed rapidly (<10 s to the surface) or slowly (1.8 ATA/min), with up to one stop lasting up to 40 min, back to surface. Rats were then observed for 30 min for signs of DCS, as described previously (13). Briefly, these signs consisted of walking difficulties, abnormal breathing patterns, forelimb and/or hindlimb paralysis, rolling in the cage, convulsions, and death. Animals were scored as having DCS only when one or more of these symptoms developed. For the gas-switching experiments (data set 3), the chamber atmosphere was switched to a different gas mixture at depth, 5-35 min allowed, and animals then decompressed rapidly to the surface. In terms of gas switching, data set 3 is unique among the data used here. Throughout the dive and postdecompression period, the animals were exercised by rotating the cage at a perimeter speed of ~3 m/min to ensure that all animals sustained a similar level of activity and to facilitate DCS scoring. After the 30-min postdive period, all surviving animals were euthanized by inhalation of CO2. After death, animals were weighed on a triple-beam balance to the nearest gram.Inert-gas decompression dives (data set 5).
These dives involved various inert-gas mixtures (20.9% O2)
using N2, He, and Ar. Most animals were held at depth for
1 h before being decompressed slowly (1.8 ATA/min) to a prescribed
stopping depth and held there for up to 40 min. Animals were then
rapidly (<10 s) decompressed to the surface. The exception to
these profiles was one group of animals, dived on Ar-O2, in
which the time at depth was varied from 10 to 120 min before rapid
decompression to the surface. These latter dives provided data from a
type of profile that had been done previously with air and
He-O2 (data set 2) but not with
Ar-O2. The exact dive profiles that were performed are
given in the leftmost column of Table 2.
|
Data Analysis
Hill-equation dose-response models predicting the probability of DCS in rats were fitted to the five data sets individually and in combination by the technique of maximum likelihood (8). The goal was to produce one general mixed-gas model based on all five data sets together. The model used here is adapted from models previously used with the individual data sets 1-4 (12-15). Many of the details of modeling used here have been described previously but are repeated below, where necessary, for clarification.Parameter values of the model were adjusted to maximize the log likelihood (LL) of the model by use of a modified Marquart nonlinear estimation algorithm (17). The likelihood ratio (LR) test was used to evaluate the significance of estimated parameters on the basis of improvement in fit (11). The shape of the likelihood surface near the converged parameters was used to estimate the precision of the parameter values. All DCS cases were treated equally, with no allowance in the model for grades in severity. The only accommodation for differences in response was to model all DCS cases (including fatalities) and then to repeat the modeling with only cases of death.
The dose-response model used for this analysis was the Hill equation
|
(1) |
The dose in Eq. 1 represents a measure of decompression stress and was defined in a manner similar to previous reports (12-15) on the basis of the traditional idea of total gas supersaturation. In the present experiments, the gases contributing to the decompression response are He, N2, Ar, and O2; CO2 is ignored. Here, O2 is treated as an inert gas, adding to the risk of DCS. Although other ways of modeling a potential effect of O2 exist, no one method appears to offer a clear advantage (19, 22). This issue is discussed further later in the text.
To allow for possible differences among gases, each partial
pressure is multiplied by a RP value that weights each gas according to
risk on a per-unit-pressure basis. The resulting equation for dose (in
ATA) is
|
(2) |
|
The Pti of He, N2, Ar, and O2 in the
animal were calculated on the basis of single exponential kinetics,
assuming a single compartment (i.e., whole rat) even though real
tissues may need a more complex model (10, 18). After a
step change in partial pressure of one gas at time 0 (t0), the Pti of the gas at time t
can be described by the following equation for t > t0
|
(3) |
The calculation for Pti becomes more complicated during actual dives in which the ambient gas partial pressures change in a nonstepwise manner (e.g., during compression or decompression). The solution, as previously described in Ref. 16, was to treat each dive as a series of partial pressure ramps that describe the pressure history of the dive. Partial pressures of individual gases at the beginning and ending of each ramp were estimated by multiplying the chamber pressure by the percentage of each gas as measured. For calculation purposes, each ramp was subdivided into a number of smaller time intervals, and Eq. 3 was used to successively compute Pti values at each interval along each ramp until decompression was completed. This procedures was performed for each of the gases that was being considered, in this case He, N2, Ar, and O2.
Separate TCs for the uptake and washout of each gas allowed for the
possibility of asymmetry in gas kinetics. This was implemented by
comparing Pti to Pami for each gas and adding
the parameter
TCi to
TCi when Pti0 > Pami in Eq. 3 (i.e., during washout).
This situation generally occurred some time after decompression began,
although this was not the case for those instances in which the dive
gas was switched to a different mixture before decompression.
Gas kinetics in Eq. 3 assume that at equilibrium the partial pressures in the animal become equal to those in the chamber. This assumption avoids the difficult task of choosing a more complicated model on the basis of inadequate knowledge of tissue-blood relationships. Although Eq. 3 models gas kinetics in the rat, it is important to emphasize that gas uptake and washout were not actually measured. Consequently, what is being modeled is the animal response to decompression and the effect of the estimated gas partial pressures on decompression risk. The TCs that are being estimated define the rates of change in processes that affect the probability of DCS or death, although interpretation in terms of gas kinetics is made in this report.
The partial pressures of the gases are reported in atmospheres absolute. To estimate the RP values, one of the potencies had to be fixed so that the other potencies could be calculated in relation to it. The RPN 2 value was arbitrarily set to 1.0 so that the P50 is expressed in terms of the partial pressure of N2 in atmospheres absolute. The effect of this weighting calculation was to convert exposures of He, Ar, and O2 into equivalent N2 exposures.
Because rat weight has been shown to have a significant effect on
the decompression outcome, a weight correction term for dose was
included in the model, as previously done, with a power function
(13). Animal weight (Wt), normalized to a weight (260 g)
close to the average weight of all animals (252 g), was raised to an
exponent denoted as the weight factor (WtF). Consequently, the final
expression for dose was
|
(4) |
The next step was to perform an LR test to determine whether the data
sets were statistically combinable
|
(5) |
In summary, this model 1) predicts the probability of DCS in
rats subjected to dives with mixtures of He, N2, Ar, and
O2; 2) assumes that the decompression response
is dependent on the degree of supersaturation of these gases in the
animal; and 3) is used to estimate the parameters governing
the location and shape of the dose-response curve, the values of RP,
TC, and
TC for the individual gases, and the exponent correcting for
animal weight.
| |
RESULTS |
|---|
|
|
|---|
Data Set 5
Table 2 presents results from data set 5, which is the only set that has not been reported previously. For a given gas mixture/depth profile, incidence of both DCS and death generally declined with increasing decompression time. For the Ar-O2 dives in which time at depth was varied (last group shown in Table 2), the incidence of both DCS and death generally increased with time at depth until leveling out sometime after 30 min.Summary of All Data (5 Data Sets)
Table 3 summarizes the decompression results from the 5,474 dives from rats that were used in this report. Overall incidence was 54.7% for DCS and 34.0% for death. Mean incidence for each of the five individual data sets ranged from 41.6 to 60.3% for DCS and 19.9 to 46.4% for death. Rat weights after diving ranged from 184 to 331 g with an overall mean ± SD of 252 ± 19 g; mean weights for the individual data sets are given in Table 3.
|
Model Parameters
Model parameters were estimated separately for DCS and death with the model described by Eqs. 1-4. Only parameters found to be significant at the 0.05 level are reported in Tables 4 and 5. For DCS, only data sets 1 and 4 were found combinable by LR testing; for death, data sets 2 and 5 and data sets 4 and 5 were shown combinable. Thus, by this test, most of the data sets are best modeled separately. However, our experience has shown that it is often very difficult to pass the LR test despite apparent similarity of data. Given that the primary goal of this work was to produce one general mixed-gas model based on all the data, we proceeded with fitting the model to the combined five data sets. Potential problems related to combinability will be discussed later.
|
|
Reported results include those with the model fitted to all of the data combined as well as fitted separately to each of the five individual data sets. Because of the unique aspects of the gas-switching experiments (data set 3, Ref. 15), modeling results are also given for the combined data after exclusion of data set 3 (noted as data sets 1, 2, 4, 5 in Tables 4 and 5). Current parameter estimates agree closely with previously reported results for the individual data sets (12-15), with the exception of data sets 1 and 2, which had been fitted earlier with a somewhat different model. This would be expected but represents a good check of the new computer code and database structure that were written to allow analysis of the combined data. We note that the previous models included only one TC for both uptake and washout of each gas, thus forcing symmetrical gas exchange.
P50 values and exponents. For all the individual data sets except data set 2, P50 values were greater for death than for DCS, reflecting the higher dose of decompression stress required to cause death. With the exception of data set 3 (gas switching), exponents were also greater for death vs. DCS, indicating a steeper response slope for death. For the model fitted to the combined data, with and without data set 3, the P50 was similar for DCS and death, although the exponent was greater for death.
Potencies. As was previously reported (12-15), large differences in potency for causing DCS or death were seen here among gases, although the magnitude of the differences varied somewhat with the specific data set. Helium potency was estimated for the individual data sets at ~10-20% less than that of N2 for both DCS and death, although it was somewhat lower for data set 3. Ar potency for both responses was estimated to be up to ~55% greater than that of N2, and O2 was shown to introduce significant decompression risk with a potency up to 90% (DCS) or 50% (death) of that of N2. Potencies for the combined data, with and without data set 3, agreed with the values estimated from individual data sets.
Predictive response curves (Fig. 1) based on the combined-data model illustrate both the differences in potencies among the inert gases (He < N2 < Ar) and the model agreement with the saturation data (data set 1). As would be expected, the observed fit to the data is not nearly as good as that previously reported for a model developed for only the saturation data (13). We also emphasize that, although only a few data points are plotted for graphing purposes, the predictive curves are based on the model fitted to all the data. For example, the three data points for Ar in Fig. 1 represent all of the dives using Ar-O2 from data set 1. We did not include the 90- and 120-min time at depth dives at 4.79 ATA from data set 5 because these animals had mean weights considerably greater that those in data set 1 and the 240 g used to generate the predictive curve. This weight difference in itself would have produced substantial deviation from the prediction, thus confounding the comparison in Fig. 1.
|
Gas exchange: Single data sets. For the individual data sets, gas uptake and washout rates were generally the same, although there were large differences among the three inert gases. The TC for He was estimated at ~3-6 min, although it was considerably greater for data set 3. If equilibration is considered to occur in four TCs, then He saturation or washout would occur in ~10-25 min. In contrast, gas exchange for N2 and Ar was generally considerably slower, with saturation estimated at ~50-80 min. The major exception to these findings was data set 5, which included many long decompression dives that might be expected to improve the estimation of gas washout. Interestingly, for this data set, N2 washout for DCS was estimated to be much faster than N2 uptake. For prediction of death, N2 uptake and washout for data set 5 were symmetrical and much faster than with the other data. For all five individual data sets, the O2 TC was indistinguishable from zero and therefore was fixed at this value during model estimation (the TC for O2 was actually fixed at 0.00001 to avoid the calculation problems associated with using zero). O2 in the animal would thus be expected to equilibrate almost immediately with a change in chamber PO2.
Gas exchange: Combined data. In the DCS model for the combined five data sets, gas uptake rates were indistinguishable from washout rates for He and N2 but not for Ar. With the exception of Ar, these results agree closely with the results from the individual data sets in terms of both symmetrical gas exchange and magnitude of the TCs. However, for death, significant differences in rate of gas uptake and washout were predicted for all three inert gases on the basis of the five-data-set model. Although the uptake rates for death were similar to those for DCS, He washout for death was approximately twice as slow as uptake, and N2 and Ar washout were approximately twice as fast as uptake. These asymmetrical gas kinetics for death differ from the symmetrical gas exchange estimated for the separate data sets and are also observed when the data is modeled after data set 3 is omitted.
Predictive curves illustrate both the differences in gas exchange rates among the three inert gases (Figs. 2 and 3) and the model agreement with the variable time-at-depth data (data set 2; Fig. 2). We note that, in Fig. 2, only one point for Ar is plotted. The Ar data from the additional variable-time-at-depth dives in data set 5 were not included because these were done at 4.79 ATA vs. the 6.30 ATA used in Fig. 2. The 6.30 ATA was selected for display because all the data for He and N2, in which time at depth was varied (data set 2), were at this depth. Consequently, most of the Ar data could not be used in Fig. 2, although, as we pointed out above, all the data were used to estimate model parameters.
|
|
Weight correction. Inclusion of a weight correction (the parameter WtF) in the model produced a significant improvement in fit for both DCS and death in all data sets except data set 5. However, the magnitude of WtF varied somewhat with the data set. A significant weight correction was also found with the combined data, with or without data set 3. This correction results in a greater probability of DCS and death in heavier animals.
Effectiveness of the Model
The ability of the model, on the basis of all five data sets, to describe the wide range of dive profiles with various mixtures of He, N2, Ar, and O2 was examined. This was done by plotting the difference (residual), between model prediction and observed incidence vs. total decompression time for each different dive profile. All the data were used, with the observed values being the mean incidence rates of the specific dive profiles. A different symbol is used on the graphs for each of the five data sets (Fig. 4) and for each of the three inert gases (Fig. 5) to allow visual comparison. Animal weight was set at 260 g for all predictions. For data set 3 in Fig. 4, total decompression time is calculated, for graphing purposes only, as starting immediately at the end of the 5-min switch to a different gas. Thus the profiles in this data set have total decompression times of 0, 10, 20, 30, or 40 min.
|
|
We emphasize that actual incidence data also have their own associated
errors (not shown on graphs), which are based on the binomial
distribution and are affected by the sample size. Although this data
error will limit interpretation of the residuals, we point out that
nearly all of the model predictions are within 40% of the observed
incidence for DCS and within 30% for death. The ability of the model
to predict that well over such a range of gas mixtures and dive
profiles is, in our opinion, quite remarkable and agrees with past
results when only two gases (He and H2) were being modeled
(16). This degree of error is all the more surprising given the nearly 150-g range in rat weight and its relatively large
effect on risk of DCS (~1% increase in DCS with each additional gram
of rat weight; Ref. 13). More importantly, the scatter of
points around zero illustrates that the model predicts DCS or death
without significant bias and generally equally well regardless of total
decompression time. The five symbols for the data sets and the three
symbols for the inert gases also appear to be randomly distributed
about zero, suggesting the absence of systematic model distortion with
respect to data set or inert gas. Also important is the fact that the
mean value of the residuals, for each of the individual data sets and
gases, is ~0, with the actual means ranging from
0.05 to 0.01.
| |
DISCUSSION |
|---|
|
|
|---|
The mixed-gas model developed here for prediction of DCS in rats is the first such model for any animal species that covers such a broad range of gas mixtures and dive profiles. The success of this model is demonstrated by 1) the relatively small errors, in view of the variety of the data, between model predictions and actual incidences and 2) the random distribution of these errors relative to total decompression time, gas mixture, and data set. Our results, based on over 5,000 dives, agree with many of the findings from past modeling of four subsets of these data (12-15), including prediction of 1) differences among the gases in potency for causing DCS and exchange rate, 2) significant decompression risk of O2, and 3) increased risk of DCS with heavier animals. New results include the prediction of asymmetrical gas exchange with gas washout often unexpectedly faster than gas uptake.
As discussed earlier, gas kinetics were extrapolated here, as well as in our previous models, from rate constants estimated from changes in DCS risk rather than determined from direct measurement of gas uptake and washout. The simplistic approach we have taken here and in previous studies (12-15) avoids using more complicated models based on unproven assumptions about blood-tissue exchange. Experience has demonstrated that very different models can often predict the response to decompression equally well. For example, in the case of rats, little effect on predictability has been observed when 1) using alternate ways for correcting for rat weight or 2) omitting the 1-ATA subtraction in the dose (13). A term for the small constant contribution of the metabolic gases (venous PO2 and PCO2 and water vapor pressure) to decompression risk has sometimes been included in past modeling efforts by others. However, its importance to predictive ability has not been clearly demonstrated. For instance, a recent probabilistic modeling exercise with human decompression data (21) has shown that, when the specific values chosen for the metabolic gases were varied, there was no significant effect on predictability of DCS.
Our approach of modeling the rat response and treating all gases, including O2, as a potential risk factor without using a physiologically based model is consistent with our past work. Again as before, we did not incorporate any link to bubble formation or growth into our overpressure model. Although a dose-response relationship has been reported for human decompression and Doppler bubble detection (7), symptoms of DCS in humans have never been shown to be well correlated with Doppler measurements (3). Watt and Lin (24) agree to the poor correlation of intravascular bubbles and DCS in animals.
A major difference with the rat model developed here, compared with the earlier models, is that this model allows for asymmetrical gas kinetics, which were predicted for all three inert gases for death but only for Ar for DCS. Until about 20 years ago, inert-gas elimination during decompression had been assumed to simply be the reverse of inert-gas uptake, both of which could be described by the same exponential function. However, a number of studies have since suggested that gas washout may be slower with decompression, owing in part, at least, to cardiovascular changes or bubble development (6, 9). Indeed, we have estimated that washout of He and H2 is over an order of magnitude slower than uptake in rats after very deep dives (20-50 ATA), although the explanation for this extreme slowing is unclear (16). The need for kinetics that reflect slower tissue washout has recently led to use of decompression models with a combination of both linear and exponential rate functions (21). Consequently, in the present model, for the combined data, the slower washout of He predicted for rat death, relative to uptake, was not surprising. However, the faster washout predicted for N2 and Ar was unexpected and, to the best of our knowledge, unreported before.
Because asymmetry in gas exchange was generally not predicted for the individual data sets, the issue arises concerning data set combinability and its effect on parameter estimates of the model for the combined data, particularly gas exchange TCs. As was stated earlier, we had proceeded with modeling the combined five data sets, although LR testing had shown that most of the data was not combinable. Despite our opinion that the formalism of the LR test produces a very conservative test that is often very difficult to pass, an important question remains whether merging of the data caused model distortion. Such distortion may have incorrectly led to prediction of asymmetry, including faster washout of some of the gases. We had concluded above that the random distribution of errors with respect to data set and inert gas suggested the absence of model distortion. We also indicated that all of the parameter estimates for the combined model, with the exception of the TCs, agreed well with the estimates for the individual data sets. However, the modeling differences with data set 3, with its relatively long He TC, and data set 5, with its asymmetrical N2 kinetics (DCS) or relatively short N2 TC (death), make these two data sets suspect for causing problems when combined with other data. Nevertheless, results argue against this. First, as discussed earlier, parameters for the combined model, with and without data set 3, agreed closely except for the Ar TC. Second, a similar comparison of the combined model, with and without data set 5, also produced good agreement, although this was not presented in Tables 4 and 5.
The most likely explanation for the predicted asymmetry of the combined model is that the merged data provided the range in dive profiles, not available in the individual data sets, necessary to resolve uptake and washout rates. This reasoning is supported by the narrow spectrum of dives within each of the data sets. Clearly data sets that were primarily designed to look at differences in gas uptake (data set 2) and gas washout (data sets 4 and 5) might be expected to be limited in their ability to estimate both aspects of gas exchange. Data set 1 (saturation dives followed by rapid decompression) should provide little kinetic information, although data set 3 (gas switching) might be expected to contain data helpful to describe both gas uptake and washout. However, we again stress that we are modeling the rat response to decompression and not gas kinetics, and we propose that the risk of DCS may become uncoupled from the gas load under certain circumstances, as suggested previously with regard to rats (16). Indeed, the comparison of the time course of predicted bubble evolution with predicted DCS risk in humans has indicated that gas-phase dynamics may not fully explain persistent DCS risk (1).
Until recently, only inert gases have been included in estimation of risk of human decompression; O2 has generally been ignored. O2 was assumed to be metabolized so rapidly during decompression that it had little effect on bubble formation and, presumably, on DCS. The present results support our previous findings (12, 14) that O2 can substantially add to the risk of DCS in rats, although this effect diminishes very quickly during decompression. Recently, two very different probabilistic models have predicted that elevated PO2 levels contribute to DCS risk in humans, although less than the equivalent amount of N2 (19). One model treated O2 as we did, as an inert gas adding to the decompression load, although a threshold was included that limited the contribution of O2 to pressures above a certain level. The other model allowed the PO2 to alter the N2 washin-washout kinetics, acknowledging the ability of PO2 to affect central and peripheral circulation. Interestingly, both models predicted risk for various human profiles similarly, demonstrating the inability to distinguish these very different approaches to defining the role of O2 in decompression. These results again emphasize the limitations of decompression modeling and raise the issue of often-unneeded model complexity. No further improvement in fit was seen in that study (19) when a combination of the two effects was employed. In another report (22), the effect of O2 was implemented similarly into a bubble model for predicting human DCS after N2 and/or He dives. The best fit in that case was obtained by including a combined O2 effect via the direct contribution to the bubble as a gas and vasoconstriction induced by hyperoxia. Despite concerns raised in these and other studies that O2 should not be used blindly without concern for potentially contributing to the risk of DCS, O2 is still deemed very useful during decompression (19). The advantage of using high-O2 mixtures was evident during the recent development of decompression procedures for the US Navy's upgraded 1.3-ATA PO2 rebreather, in which significant reduction in decompression times was achieved (20).
| |
FOOTNOTES |
|---|
Address for reprint requests and other correspondence: R. S. Lillo, Biomedical Research Dept., Navy Experimental Diving Unit, 321 Bullfinch Rd., Panama City, FL 32407-7015 (E-mail: lillors{at}nedu.navsea.navy.mil).
The costs of publication of this article were defrayed in part by the payment of page charges. The article must therefore be hereby marked "advertisement" in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.
Received 27 March 2000; accepted in final form 28 June 2000.
| |
REFERENCES |
|---|
|
|
|---|
1.
Ball, R,
Himm J,
Homer LD,
and
Thalmann ED.
Does the time course of bubble evolution explain decompression sickness risk?
Undersea Hyperb Med
22:
263-280,
1995[Medline].
2.
Ball, R,
Lehner CE,
and
Parker EC.
Predicting risk of decompression sickness in humans from outcomes in sheep.
J Appl Physiol
86:
1920-1929,
1999
3.
Bayne, CG,
Hunt WS,
Johanson DC,
Flynn ET,
and
Weathersby PK.
Doppler bubble detection and decompression sickness: a prospective clinical trial.
Undersea Biomed Res
12:
327-332,
1985[ISI][Medline].
4.
Boycott, AE,
Damant GCC,
and
Haldane JS.
Prevention of compressed air illness.
J Hyg Lond
8:
342-443,
1908.
5.
Burkard, ME,
and
Van Liew HD.
Simulation of exchanges of multiple gases in bubbles in the body.
Respir Physiol
95:
131-145,
1994[ISI][Medline].
6.
D'Aoust, BG,
Swanson HT,
White R,
Dunford R,
and
Mahoney J.
Central venous bubbles and mixed venous nitrogen in goats following decompression.
J Appl Physiol
51:
1238-1244,
1981
7.
Eckenhoff, RG,
Olstad CS,
and
Carrod G.
Human dose-response relationship for decompression and endogenous bubble formation.
J Appl Physiol
69:
914-918,
1990
8.
Edwards, AWF
Likelihood. London: Cambridge Univ. Press, 1972.
9.
Hills, BA.
Effect of decompression per se on nitrogen elimination.
J Appl Physiol
45:
916-921,
1978
10.
Homer, LD,
Weathersby PK,
and
Survanshi S.
How countercurrent blood flow and uneven perfusion affect the motion of inert gas.
J Appl Physiol
69:
162-170,
1990
11.
Kendall, MG,
and
Stewart A.
The Advanced Theory of Statistics (4th ed.). London: Haffner, 1979, vol. 2, p. 38-180.
12.
Lillo, RS.
Effect of N2-He-O2 on decompression outcome in rats after variable time-at-depth dives.
J Appl Physiol
64:
2042-2052,
1988
13.
Lillo, RS,
Flynn ET,
and
Homer LD.
Decompression outcome following saturation dives with multiple inert gases in rats.
J Appl Physiol
59:
1503-1514,
1985
14.
Lillo, RS,
and
MacCallum ME.
Decompression comparison of N2 and O2 in rats.
Undersea Biomed Res
18:
317-331,
1991[ISI][Medline].
15.
Lillo, RS,
and
MacCallum ME.
Effect of inert gas switching at depth on decompression outcome in rats.
J Appl Physiol
67:
1354-1363,
1989
16.
Lillo, RS,
Parker EC,
and
Porter WR.
Decompression comparison of helium and hydrogen in rats.
J Appl Physiol
82:
892-901,
1997
17.
Marquart, DW.
An algorithm for least-squares estimation of non-linear parameters.
J Soc Ind Appl Math
11:
431-441,
1963.
18.
Novotny, JA,
Mayers DL,
Parsons YJ,
Survanshi SS,
Weathersby PK,
and
Homer LD.
Xenon kinetics in muscle are not explained by a model of parallel perfusion-limited compartments.
J Appl Physiol
68:
876-890,
1990
19.
Parker, EC,
Survanshi SS,
Massell PB,
and
Weathersby PK.
Probabilistic models of the role of oxygen in human decompression sickness.
J Appl Physiol
84:
1096-1102,
1998
20.
Survanshi, SS,
Parker EC,
Gummin DD,
Flynn ET,
Toner CB,
Temple DJ,
Ball R,
and
Homer LD.
Human Decompression Trial with 1.3 ATA Oxygen in Helium. Bethesda, MD: Naval Medical Research Institute, 1998. (NMRI Rep. 98-09)
21.
Thalmann, ED,
Parker EC,
Survanshi SS,
and
Weathersby PK.
Improved probabilistic decompression model risk predictions using linear-exponential kinetics.
Undersea Hyperb Med
24:
255-274,
1997[ISI][Medline].
22.
Tikuisis, P,
and
Nishi RY.
Role of Oxygen in a Bubble Model for Predicting Decompression Illness. North York, Ontario, Canada: Defence and Civil Institute of Environmental Medicine, 1994. (DCIEM No. 94-04)
23.
Van Liew, HD.
Simulation of the dynamics of decompression sickness bubbles and the generation of new bubbles.
Undersea Biomed Res
18:
333-345,
1991[ISI][Medline].
24.
Watt, DG,
and
Lin YC.
Doppler detection of thresholds for decompression-induced venous gas emboli in the awake rat.
Space Environ Med
50:
571-574,
1979.
25.
Weathersby, PK,
and
Homer LD.
Solubility of inert gases in biological fluids and tissues: a review.
Undersea Biomed Res
7:
277-296,
1980[ISI][Medline].
26.
Weathersby, PK,
Homer LD,
and
Flynn ET.
On the likelihood of decompression sickness.
J Appl Physiol
57:
815-825,
1984
This article has been cited by other articles:
![]() |
R. Arieli, P. Svidovsky, and A. Abramovich Decompression sickness in the rat following a dive on trimix: recompression therapy with oxygen vs. heliox and oxygen J Appl Physiol, April 1, 2007; 102(4): 1324 - 1328. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Arieli, O. Ertracht, I. Oster, A. Vitenstein, and Y. Adir Effects of nitrogen and helium on CNS oxygen toxicity in the rat J Appl Physiol, January 1, 2005; 98(1): 144 - 150. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. S. Lillo, J. F. Himm, P. K. Weathersby, D. J. Temple, K. A. Gault, and D. M. Dromsky Using animal data to improve prediction of human decompression risk following air-saturation dives J Appl Physiol, July 1, 2002; 93(1): 216 - 226. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| Visit Other APS Journals Online |