|
|
||||||||
Departments of 1 Orthopedics, 3 Surgery, 4 Internal Medicine, and 5 Pathology, College of Medicine, National Cheng Kung University, Tainan, Taiwan 704; and 2 Department of Marine Resources, National Sun Yat-Sen University, Kaohsiung, Taiwan 804 Republic of China
| |
ABSTRACT |
|---|
|
|
|---|
Our new oropharyngeal intubation wedge made from a plastic 3-ml syringe has been used successfully for the expansion of the oropharyngeal cavity and visualization of vocal cords for endotracheal intubation in the rat. All the animals we used tolerated the intubation and ventilation procedures in a series of experiments. After the proper setting of the respirator, vital signs were maintained within normal range. The postmortem examination and measurements in the upper airway confirmed that the endotracheal tube was properly sited and also demonstrated the precise size of the device that should be used. The main advantages of this method include low cost, simplicity, and reliability. Furthermore, because no expensive, elaborate, difficult-to-operate, or hard-to-get special equipment is needed, this technique can be used in every laboratory.
endotracheal intubation; Rattus species; experimental techniques
| |
INTRODUCTION |
|---|
|
|
|---|
ENDOTRACHEAL INTUBATION CAN easily be performed on most medium-sized experimental animals, such as rabbits and dogs, under general anesthesia with an infant-sized laryngoscope (no. 2-3) and endotracheal tube (no. 3-4). However, in smaller animals, such as rats, the intubation technique is more difficult because the rat has a much smaller inlet for an endotracheal tube. Most methods of endotracheal intubation require elaborate, specially designed equipment (1, 3, 5, 6, 8-11) that is not always available, is usually expensive, and always requires considerable practice before sufficient skill for successful intubation without complications is acquired. Here we report a simple method that requires only a specially designed oropharyngeal intubation wedge made from a 3-ml plastic syringe, a readily available piece of equipment. The technique requires little effort to master and has a very high success rate. In addition, the rat can be intubated in any position without having to be anchored to the operating table, and its vital signs can be maintained easily to avoid complications during intubation.
| |
MATERIALS AND METHODS |
|---|
|
|
|---|
The experimental protocol was reviewed and approved by the National Science Council of the Republic of China and the College of Medicine, National Cheng Kung University.
Specially designed oropharyngeal intubation wedge.
Our method of intubating the rat trachea relies on the use of a
specially designed oropharyngeal intubation wedge made from the barrel
of a standard 3-ml plastic syringe (Becton Dickinson, Singapore). The
roof of the wedge is 1 cm long, the bottom is 2.5 cm long, and the
wedge angle is 25° (Fig. 1). The
fingerholds of the syringe remain and can be used to manipulate the
head and neck of the rat after insertion and fixation of the wedge to
the oropharyngeal cavity (Fig. 2).
|
|
Animal preparation and intubation procedure.
The rats were anesthetized with Pentothal (sodium thiopentone, Abbot,
Sydney, Australia; 50 mg/kg ip) and placed in supine position without
fixation to the operating table. The mouth of the anesthetized animal
was opened by hand or mosquito clamp. Next, the oropharyngeal
intubation wedge was inserted with the bottom touching the rat's
tongue and the roof touching its palate. The tip of the wedge was
inserted to the level of the epiglottis and vallecula (Fig.
3). The wedge was easily fixed firmly in
the oropharyngeal cavity by natural pressure from the incisors: the inner surface of the edge of the syringe to the lower incisors and the
outer to the upper incisors. No additional fixation was needed. The
oropharyngeal intubation wedge was held in a thumb and index finger
pinch while the other fingers held the rat's head (Fig. 2). This
allowed the animal to be manipulated freely. An ordinary table lamp was
an adequate light source when the light was concentrated on the ventral
area of the rat's neck near the pharyngoepiglottic region. With the
tip of the oropharyngeal intubation wedge in the vallecula, elevating
the tip by depressing the fingerholds allowed the experimenter to
observe the epiglottis and larynx with the help of the light from the
table lamp. The movement of the vocal cords, the most significant sign
of the entrance of the trachea, could easily be seen. The wedge and
light source provided an excellent view, including a distinct contrast
between the white vocal cords and the red surrounding tissue. A
16-gauge intravenous catheter (45 mm length; 20-mm hub; 1.7-mm ID) with a 70-mm-long wire stylet with a 30-mm hub (Insyte, Becton Dickinson, Sandy, UT) was used as the endotracheal tube. After the 5-mm-long, sharp tip of the stylet was cut off, the end of the catheter with the
stylet was then inserted through the oropharyngeal wedge directly into
the entrance of the trachea. The stylet was then withdrawn, and the
catheter was advanced into the trachea 2-3 cm farther (Fig.
4). The oropharyngeal intubation wedge
was then removed, and the catheter was tied to the incisors or sutured
to the surrounding area. The catheter hub was connected to the
respirator, and the expansion and collapse of the chest confirmed that
the catheter was in the trachea.
|
|
Monitoring of the vital signs and measurement of the size of the airway. No new animals were used or killed for this study. Our data are taken from three different evoked-potential experiments unrelated to the cardiopulmonary mechanism. From the 86 Sprague-Dawley or Wistar rats used in these experiments, we randomly chose 18. Before the final procedure of each of these primary evoked-potential experiments, the intubation procedures we describe here were performed and the animals' vital signs were monitored. The ventilation was controlled with an IPPB Respirator UR-100 (Shin-Ei Industry, Tokyo, Japan) that was set at a tidal volume of 5 ml/kg and respiratory rate of 40 breaths/min with 100% O2 and 0.5 l/min flow rate. A femoral artery was also cannulated with a 22-gauge catheter for continuous monitoring of heart rate and blood pressure and sampling for blood-gas analysis. The data of these vital signs were collected immediately and 30 min after the mechanical ventilation. The rats were otherwise undisturbed during the 30 min. Next, the final phases of the evoked-potential experiments, all of which required postmortem analysis, were completed.
After completion of the primary evoked-potential experiment, and after a lethal overdose of Pentothal, each of the 18 animals was dissected. The length of the oropharynx and trachea and the diameter of the trachea were measured. The length of the oropharynx and trachea was defined as the sum of the distance from the upper incisors to the vocal cords plus the distance from the vocal cords to the bifurcation of the trachea. All measurements were made with a caliper (Mitsutoyo, Tokyo, Japan).| |
RESULTS |
|---|
|
|
|---|
A total of 18 adult Sprague-Dawley or Wistar rats, weighing between 300 and 530 g, used in three experiments investigating evoked potential and using this intubation technique for ventilation or anesthesia were reviewed. No rat died or suffered any respiratory problem from intubation to extubation, and all withstood the surgical procedures of the experiments.
The intubation procedure was simple and quick. In particular, the insertion of the endotracheal catheter into the trachea was very easy because the oropharyngeal intubation wedge and the light penetrating from the ventral area of the neck allowed a clear, direct view of the epiglottis and vocal cords (the entrance of the trachea). With the endotracheal catheter in place, the rat could be ventilated or could undergo general anesthesia by administration of inhalative anesthetics. The time required to complete the intubation was <30 s, and the total ventilation duration was >3 h, without difficulty in extubation or recovery. The procedure was also simplified by the fact that the rat's upper airway after application of the oropharyngeal intubation wedge could be manipulated easily, which provided a very versatile approach to the entrance of the trachea.
None of the 18 rats randomly selected for this study showed any
significant change in vital signs from the beginning of the intubation
procedure until 30 min after the ventilation. All parameters were stable and within normal range (Table
1).
|
The postmortem examination showed the endotracheal catheter to be at
the correct site, with the tip at about the junction of the middle and
distal third of the trachea. The catheter was patent in all examined
rats. The individual body weights and oropharynx and trachea
measurements are shown in Fig. 5. Because
the measurements were made from a curved surface, precision was
impossible. The average length of the oropharynx was 3.03 ± 0.25 cm (range 2.8-3.5 cm) and of the trachea was 3.58 ± 0.43 cm
(range 3.0-4.5 cm). The ranges of the oropharynx and trachea
lengths are narrow and show no statistically significant correlation
with body weight. From these data and the actual results in these
experiments, the oral intubation wedge we used was suitable to all the
rats, regardless of size or weight.
|
| |
DISCUSSION |
|---|
|
|
|---|
The choice of animal to use in experiments cannot be made just to meet the goals and designs of the experiment. Several factors in many curricula limit the choice, such as expense, lack of adequate facilities and equipment, and limited experience with different kinds of animals. In addition, the ethical concerns of individual researchers and animal rights advocates have caused those involved in animal study generally to avoid using primate species (4) and even domestic animals such as dogs and cats. It is not surprising, then, that the rat's appearance in scientific experiments is increasing. A review of the Journal of Orthopaedic Research from 1982 to 1999 showed the rat and rabbit are the two most frequently used in animal studies. It seems reasonable to focus some research on techniques and devices that might introduce greater simplification and speed in animal studies, might free the animal subjects of unintentionally caused pain, and might significantly reduce the meaningless deaths of animals used in surgical procedures (2).
Thet's experience (8), as well as the development of many other methods (1, 3, 5, 6, 9-11), clearly shows that a 90% success rate could not be obtained by Stark et al.'s (7) blind intubation technique for the rat. A reliable intubation probably can be achieved with a variety of devices, such as a fiber-optic, miniature, or human laryngoscope; a head-mounted, mirror-reflected, adjustable-focus light; a surgical microscope; a fiber-optic illuminator with an attached flexible light guide; an otoscope with an incorporated light source; or some other special and expensive device (1, 3, 5, 6, 8-11). However, one of these devices may be not available in every laboratory, so we think that a simple and inexpensive method of intubation under direct vision is warranted.
Our newly designed oropharyngeal intubation wedge overcomes all the mentioned problems associated with other intubation devices. First, it is made from a common 3-ml syringe, which is cheap and available almost everywhere. Second, using the wedge is easy. Third, when inserted, it does not overstimulate the mucous wall of the upper airway. During intubation procedures requiring more time or insertion of a fiber-optic light source into the pharyngeal cavity, an abundance of mucus may be produced and cover the laryngeal cavity. This mucus may interfere with visualization and insertion of an endotracheal tube into the trachea. This problem is never encountered with the oropharyngeal intubation wedge because the procedure requires a very short time and because only the endotracheal catheter will touch the pharyngeal wall. Fourth, the subsequent expansion of the oropharyngeal cavity is both reliable and static. Fifth, because the rat does not need to be fixed to the operating table, it can be manipulated into any position suitable for observation of the cavity. Direct visibility of the epiglottis and the movement of the vocal cords are guaranteed by both the ability to adjust the rat's neck and the light from the ventral aspect of the neck. The blind method offers none of these advantages, and few of them are available with the other ingenious intubation devices reported. Sixth, the procedures in this technique seem natural and cause less distress to the animal subject's respiration than other intubation methods. Finally, even if the intubation cannot be accomplished smoothly and quickly by the beginner, the airway will be kept properly open by the oropharyngeal intubation wedge, and the rat will not die meaninglessly.
The endotracheal tubes used for the rats in our study were 14- to 16-gauge intravenous catheters; 16 gauge is preferred in most studies (1, 3, 5-11), and a plastic catheter from 45 to 60 mm long is recommended. The results in our study closely correlated with the suggestions of other researchers. From vocal cords to bifurcation, the trachea in rats weighing 300-530 g was 3.58 mm on average (range 3.0-4.5 mm). The variations in length correlated well with body weight. The 70- to 90-mm long malleable gauge wire needle within the plastic catheter is used as a stylet after the sharp end is cut off at the same length level or 1-2 mm shorter than the plastic catheter (8, 11). The wire provides stiffness and aids in direction control. However, the stylet should be withdrawn once the catheter crosses the vocal cords to avoid any inadvertent trauma to the trachea.
In summary, our experience and the anatomic and physiological examinations in this study proved this new method of intubation using the oropharyngeal intubation wedge to be very low-cost, simple, safe, and effective.
| |
ACKNOWLEDGEMENTS |
|---|
We thank Bill Franke for proofreading and revising the English in the manuscript.
| |
FOOTNOTES |
|---|
This study was supported by National Science Council of the Republic of China Research Grant NSC 89-2320-B-006-063.
Address for reprint requests and other correspondence: N.-S. Wang, Dept. of Pathology, College of Medicine, National Cheng Kung Univ., No. 138 Sheng-Li Rd., Tainan, Taiwan 704, Republic of China.
The costs of publication of this article were defrayed in part by the payment of page charges. The article must therefore be hereby marked "advertisement" in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.
Received 8 February 2000; accepted in final form 1 June 2000.
| |
REFERENCES |
|---|
|
|
|---|
1.
Alpert, M,
Goldstein D,
and
Triner L.
Technique of endotracheal intubation in rats.
Lab Anim Sci
32:
78-79,
1982[ISI][Medline].
2.
Carlsson, B.
Ethical issues in animal experimentation
view of the animal rightist.
Acta Physiol Scand Suppl
554:
50-68,
1986[Medline].
3.
Costa, DL,
Lehmann JR,
Harold WM,
and
Drew RT.
Transoral tracheal intubation of rodents using a fiberoptic laryngoscope.
Lab Anim Sci
36:
256-261,
1986[ISI][Medline].
4.
Kamholz, SL,
Brewer RJ,
Grijalva G,
Burack J,
Del Rio MJ,
Vaynblatt M,
Lawson N,
Squinto S,
Fodor WL,
and
Norin AJ.
Laboratory studies in cross-species lung transplantation.
World J Surg
21:
951-955,
1997[ISI][Medline].
5.
Pena, H,
and
Cabrera C.
Improved endotracheal intubation technique in the rat.
Lab Anim Sci
30:
712-713,
1980[ISI][Medline].
6.
Proctor, E,
and
Fernando AR.
Oro-endotracheal intubation in the rat.
Br J Anaesth
45:
139-142,
1973
7.
Stark, RA,
Nahrwold ML,
and
Cohen PJ.
Blind oral tracheal intubation of rats.
J Appl Physiol
51:
1355-1356,
1981
8.
Thet, LA.
A simple method of intubating rats under direct vision.
Lab Anim Sci
33:
368-369,
1983[ISI][Medline].
9.
Tran, DQ,
and
Lawson D.
Endotracheal intubation and manual ventilation of the rat.
Lab Anim Sci
36:
540-541,
1986[ISI][Medline].
10.
Weksler, B,
Ng B,
Lenert J,
and
Burt M.
A simplified method for endotracheal intubation in the rat.
J Appl Physiol
76:
1823-1825,
1994
11.
Yasaki, S,
and
Dyck PJ.
A simple method for rat endotracheal intubation.
Lab Anim Sci
41:
620-622,
1991[ISI][Medline].
This article has been cited by other articles:
![]() |
J. Chen, Z. Chen, N. R. Chintagari, M. Bhaskaran, N. Jin, T. Narasaraju, and L. Liu Alveolar type I cells protect rat lung epithelium from oxidative injury J. Physiol., May 1, 2006; 572(3): 625 - 638. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Gou, T. Narasaraju, N. R. Chintagari, N. Jin, P. Wang, and L. Liu Gene silencing in alveolar type II cells using cell-specific promoter in vitro and in vivo Nucleic Acids Res., September 27, 2004; 32(17): e134 - e134. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Kastl, U. Kotschenreuther, B. Hille, J. Schmidt, H. Gepp, and W. Hohenberger Simplification of rat intubation on inclined metal plate Advan Physiol Educ, March 1, 2004; 28(1): 29 - 32. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| Visit Other APS Journals Online |