Department of Anesthesiology and Critical Care Medicine, The Johns Hopkins University School of Medicine, Baltimore, Maryland 21287-7834
| |
ABSTRACT |
|---|
|
|
|---|
Mechanical ventilation with positive end-expiratory pressure (PEEP) may prevent venous air embolism in the sitting position because cerebral venous pressure (Pcev) could be increased by the PEEP-induced increase in right atrial pressure (Pra). Whereas it is clear that there is a linear transmission of the PEEP-induced increase in Pra to Pcev while the dog is in the prone position, the mechanism of the transmission with the dog in the head-elevated position is unclear. We tested the hypothesis that a Starling resistor-type mechanism exists in the jugular veins when the head is elevated. In one group of dogs, increasing PEEP linearly increased Pcev with the dog in the prone position (head at heart level, slope = 0.851) but did not increase Pcev when the head was elevated. In another group of dogs, an external chest binder was used to produce a larger PEEP-induced increase in Pra. Further increasing Pra increased Pcev only after Pra exceeded a pressure of 19 mmHg (break pressure). This sharp inflection in the upstream (Pcev)-downstream (Pra) relationship suggests that this may be caused by a Starling resistor-type mechanism. We conclude that jugular venous collapse serves as a significant resistance in the transmission of Pra to Pcev in the head-elevated position.
right atrial pressure; jugular venous pressure; intracranial pressure; Starling resistor; chest binder
| |
INTRODUCTION |
|---|
|
|
|---|
MECHANICAL VENTILATION with positive end-expiratory pressure (PEEP) has been advocated as a means of preventing venous air embolism in the sitting position (7, 17). It is hypothesized that PEEP may decrease the incidence of venous air embolism by increasing right atrial pressure (Pra), which, in turn, increases cerebral venous pressure (Pcev) to a level greater than atmospheric pressure. Whereas PEEP may increase Pcev in prone dogs positioned with the head at heart level (14), PEEP up to 20 cmH2O has little effect on Pcev with the head in an elevated position (16). This attenuated effect of PEEP on Pcev in subjects in the head-elevated position could be due to the presence of jugular venous valves, distensible veins in the neck that disperse the effect of PEEP, or collapsible venous channels (Starling resistor effects) that offset the increase in Pra. Previously, our laboratory (16) hypothesized that PEEP may increase Pcev if PEEP increased to a level that caused Pra to exceed the hydrostatic gradient between the right atrium and cerebral veins created by head elevation.
This study was undertaken to determine the Starling resistor effect in the transmission of increased Pra to Pcev in the head-elevated position. We utilized PEEP alone and in combination with external chest compression to further increase PEEP-induced Pra to characterize the relationship between Pra and Pcev in the head-elevated position.
| |
MATERIALS AND METHODS |
|---|
|
|
|---|
The study was conducted in accordance with the National Institutes of Health guidelines for the use of experimental animals, and the protocols were approved by the Animal Care and Use Committee of The Johns Hopkins Medical Institutions.
Preparation
Twenty-four dogs were studied. Adult male beagle dogs (9-12 kg) were anesthetized with pentobarbital sodium (30 mg/kg iv) and maintained with intermittent intravenous administration of fentanyl (1-2 µg · kg
1 · h
1).
All dogs were paralyzed with pancuronium bromide (0.2 mg/kg iv), and
their lungs were mechanically ventilated via an endotracheal tube
(tidal volume 10 ml/kg). All animals were given supplemental anesthesia
(pentobarbital and fentanyl) in response to hypertension and
tachycardia. End-tidal CO2 was maintained between 30 and 35 mmHg throughout the experiment by adjusting respiratory rate. Arterial
blood gases were measured with a self-calibrating Radiometer electrode
system (ABL 3; Copenhagen, Denmark). Supplemental oxygen was
administered to maintain arterial PO2
between 100 and 150 Torr. Esophageal temperature was maintained at 38 ± 1°C with a heat lamp and heating pad.
With the dog in the supine position, catheters were placed in the
femoral arteries for monitoring mean arterial blood pressure (MABP) and
obtaining blood-gas samples. A 7-Fr catheter was advanced through the
right femoral vein and positioned at the right atrium for measurement
of Pra. A catheter was placed via the other femoral vein for fluid
administration. In one group of 12 dogs, jugular venous pressure was
measured at two different locations [upper jugular (Puj) and
lower jugular (Plj)]. In these dogs two 4.0-Fr (18-gauge)
catheters were inserted nonocclusively into the midportion of the left
jugular vein. One catheter was directed 5 cm cephalad for measurement
of Puj (tip at angle of mandible, ~20 cm from the right atrium), and
the other catheter was directed 5 cm caudally for measurement of Plj
(tip at the level of omocervical vein, ~10 cm from the right atrium)
(Fig. 1).
|
The dog was then turned prone, and the head was stabilized in a head holder with the external auditory meatus positioned at right atrial level. The superior sagittal sinus was exposed at the level of the coronal suture and cannulated in the direction of the confluence of sinuses. This catheter was used for the monitoring of Pcev. In another group of 12 dogs, a 22-gauge catheter was inserted into the cisterna magna for measurement of cerebrospinal fluid pressure (CSFP). In these dogs, an external chest binder (Dura-cuff CritiKon, range 38-50 cm) was applied to augment the increase in Pra during PEEP ventilation. All animals were well hydrated with lactated Ringer and 5% albumin solution to maintain Pra at ~3.0-5.0 mmHg.
Experimental Protocol
Part I. We investigated the effects of increasing Pra with PEEP on external Puj and Plj and Pcev in the prone position with the head at the level of the right atrium and with the head elevated 25 cm above the right atrium (from external auditory meatus to 5th intercostal space at the lower one-third of dorsoventral distance). With the dog in the prone position, with the head at heart level or in the head-elevated position, all transducers were zeroed at the level of the right atrium. Measurements of Pcev, Puj, Plj, and Pra were recorded at PEEP = 0 and then after the addition of 5, 10, 15, 20, 25, 30, and 35 cmH2O by placing the expiratory tubing from the endotracheal tube under varying depths of water. Each PEEP increment lasted for 1-2 min; PEEP = 0 was established for 1-2 min between each increment to determine the change between PEEP = 0 and each increment of PEEP. After obtaining all data, we repeated the protocol with the dog positioned with its head elevated 25 cm above the level of the right atrium with the head supported by a head holder.
Part II. We investigated the effects of further increasing Pra during PEEP on Pcev. Only two levels of PEEP, 17 and 34 cmH2O (12.5 or 25 mmHg), were studied. With the dog in the prone position with the head at heart level, measurements of Pcev, CSFP, and Pra were first recorded at PEEP = 0, with chest binder uninflated, with the chest binder inflated to 40 and 80 mmHg, and then after addition of 17 and 34 cmH2O PEEP with the chest binder unbound and bound. Similar studies were repeated with the head elevated 25 cm above the heart level as in part I. All transducers were zeroed at the level of the right atrium.
| |
RESULTS |
|---|
|
|
|---|
Part I
Throughout each protocol, blood-gas values were maintained within physiological limits. At baseline, arterial PCO2 was 35 ± 4 Torr, arterial PO2 was 120 ± 15 Torr, and pH was 7.395 ± 0.093, and these values were unchanged throughout the protocol.At baseline, MABP was similar between the head at heart level and the
elevated positions (135 ± 6 vs. 136 ± 5 mmHg). With the
head at heart level, increasing PEEP to 20 cmH2O decreased MABP. With the head elevated, the first significant decrease in MABP
occurred at PEEP of 25 cmH2O (Table
1). MABP continued to fall as PEEP was
elevated to 30 and 35 mmHg with the head at heart level or when the
head was in the elevated position (Table 1).
|
At baseline, Pcev was higher in the head at the heart-level position
compared with the head-elevated position, 7.6 ± 0.5 vs. 2.3 ± 0.8 mmHg (transmural). With the head at the heart-level position, Pcev
increased progressively with the increase in PEEP, and the rise was
greatest at a PEEP of 35 cmH2O. In this position, an
increase in PEEP to only 10 cmH2O increased Pcev (Table 1). In contrast, Pcev was not altered by increasing PEEP, despite a similar
magnitude in the increase of Pra by PEEP (Table 1). For each individual
animal, a linear regression was performed between Pra and Pcev. The
average slope of this relationship in the head at the heart-level
position (slope of 0.851 with an intercept at 2.1 mmHg, r = 0.820) was significantly greater than the slope in the head-elevated
position (slope of 0.254 with an intercept at 21.2 mmHg, r = 0.310) (Fig. 2).
|
In the head at the heart-level position, there was no difference among
Pcev, Puj, Plj, and Pra. As a result of increasing PEEP, there was a
linear increase in Pcev, Puj, and Plj in concert with the increase in
Pra (Table 1; Fig. 3A). However, in
the head-elevated position, the PEEP-induced increased Pra was
transmitted upward in a decreasing order. With the sagittal sinus
located at the highest level from the heart, the pressure (Pcev) was
not significantly increased (Fig. 2B). Puj measured at the
second highest level did not significantly increase until PEEP
increased to 25 cmH2O (Pra = 11.7 ± 0.9 mmHg) (Table 1;
Fig. 3B), whereas Plj, measured at the lowest level, increased
significantly at a PEEP of only 10 cmH2O (Pra = 7.5 ± 0.1 mmHg). The average vertical distances from the levels at which Pcev,
Puj, and Plj were measured to the level of the right atrium were 28.1 ± 0.5, 19.7 ± 0.3, and 9.8 ± 0.9 cm, respectively.
|
Part II
Application of the chest binder is more effective in raising Pra than that of PEEP alone in both positions (Table 2). In the head at the heart-level position, application of the chest binder during PEEP ventilation caused a further increase in Pcev and CSFP. In the head-elevated position, with application of a chest-binder pressure at 80 mmHg alone without PEEP, Pra increased to 18.0 ± 2.0 mmHg; with this pressure, both Pcev and CSFP increased significantly. With PEEP alone, either at 17 or 34 cmH2O, Pcev was not changed (Table 2). When the relationship between Pcev and Pra was analyzed, it was similar to that obtained in the part I study, with a slope of 0.22 and r = 0.31 (Fig. 4C). An increase in both Pcev and CSFP was not noted until Pra was increased to
20 mmHg at a PEEP of 17 and 34 cmH2O and when combined
with a chest-binder pressure of 40 and 80 mmHg. The relationship
between Pcev and Pra is shown in Fig. 4D with a slope of 0.73 and r = 0.68, which was significantly different compared with
Fig. 4C. In the head at the heart-level position, the
relationship was not different from that of PEEP alone without the
chest binder.
|
|
| |
DISCUSSION |
|---|
|
|
|---|
In the head at the heart-level position, application of PEEP produced a relatively linear increase in Pra and Pcev; however, in the head-elevated position, even a very high level of PEEP (35 cmH2O) did not increase Pcev, despite a similar increase in Pra. In the head-elevated position, the transmission of PEEP-induced increased Pra was in a decreasing order along the jugular vein according to the vertical distance from the right atrium. In both positions, chest-binder inflation further increased Pra, regardless of PEEP level. In the head-elevated position, only when Pra was increased to >20 mmHg by combination of PEEP and chest-binder inflation did Pcev increase.
The mechanism by which PEEP increases CSFP with the head at heart level has been well studied in animal models. With normal lung and chest wall compliances, approximately one-half of the applied airway pressure is transmitted intrathoracically (2). Huseby et al. (11) showed that PEEP increased CSFP by increasing Pra and pleural pressure. Luce et al. (14) showed that PEEP increased CSFP primarily by increasing superior vena caval pressure and decreasing cerebral venous outflow. Because there is a close correlation between CSFP and pleural pressure, they (14) concluded that the acute changes in CSFP caused by PEEP were mediated by pleural pressure. These studies indicate that pressure transmission occurs primarily through venous channels.
With the animal in the head-elevated position, our previous studies in dogs (16) and human subjects (12) demonstrated that PEEP had no effect on Pcev. The reason for this failure of PEEP to increase Pcev is unclear; however, it has been hypothesized that the presence of jugular venous valves located at the thoracic inlet may mechanically prevent transmission of the increased Pra via the jugular veins. Another possibility is that the PEEP-induced increased Pra may not be high enough to overcome the closing pressure of the collapsed jugular veins.
The evidence that transmission of intrathoracic pressure to the jugular veins is blocked by valves at the thoracic inlet comes from the studies of Fisher et al. (5) and Guerci et al. (6) in both humans and animals. Although a retrograde flow of blood was prevented by the competent jugular venous valves during sudden forceful coughing in humans (transvalvular pressure gradients of 52 mmHg), the closure of the valves should only be momentary because the outflow from the brain must continue, and these valves will remain open. Furthermore, the animal studies were carried out either in in vivo static conditions or during cardiopulmonary resuscitation in fibrillated dogs. There was no flow in each condition. These conditions contrast sharply with studies of PEEP in living animals and earlier human studies with regular coughing. In the study of Huseby et al. (11) on the effects of PEEP on intracranial pressure in dogs, they found the magnitude of intracranial pressure changes depended on the changes in the PEEP-induced increase in venous pressure. No mention was made concerning the presence of jugular venous valves. In earlier human studies by Myerson et al. (15), a two- to fourfold increase in jugular venous pressure was found during regular coughing, straining, and even during loud talking. Luce et al. (14), studying the mechanism by which PEEP increased CSFP in dogs, found that CSFP could be increased immediately and parallels the rise in superior vena cava pressure. In the present study with the animal in the head-elevated position, we have further shown that Plj, measured beyond the jugular venous valves, could be elevated in parallel with PEEP-induced increases in Pra. As these studies have demonstrated that the jugular venous valves do not prevent the pressure transmission, it is likely that these jugular venous valves are inconsequential.
With the assumption that the entire increase in Pra is transmitted
through the jugular venous channel, collapse of jugular veins, when the
head is elevated, could be the main resistance to pressure transmission
upward. One mechanism by which the surrounding pressure of a vascular
system can affect blood flow is based on the vascular waterfall model
of the pulmonary circulation (13). This model suggests that, if
extravascular pressure exceeds intravascular pressure within a
collapsible segment, there must be a point at which the surrounding
pressure will exactly equal the intravascular pressure. Under these
conditions, blood flow through the vascular segment proximal to that
point will be proportional to the arterial inflow pressure minus the
surrounding pressure. As long as the outflow pressure remains less than
surrounding pressure, the outflow pressure will have no effect on
altering flow through the vascular segment. However, when outflow
pressure is equal to or higher than surrounding pressure, it (outflow
pressure) becomes the back pressure for flow. Similarly, in the brain,
it has been demonstrated that the vein collapses when it is elevated
above the heart because the surrounding pressure is greater than the
pressure inside the vein, thus creating a Starling resistor effect. In
a Starling resistor, defined as an easily collapsible vascular segment
submitted to an external pressure, blood flow will start when upstream
pressure is large enough to cause the pressure inside the collapsed
segment (intravascular pressure) to exceed the external pressure
(extravascular pressure) and thus open the vessels. The Starling
resistor upstream pressure at which the vessels collapse is often
referred to as the closing pressure. With relatively constant flow,
such as in a living subject, the upstream pressure remains almost
constant at this level, despite small changes in downstream pressure.
Holt (9) demonstrated in dogs that, when a vein was held above heart level, atrial pressure had to be increased by several centimeters of
water before there was any rise in peripheral venous pressure. Holt
(10) further showed in humans that, with the subject in the sitting
position, the elevated cephalic vein partially collapsed at the point
at which it entered the upper end of the thorax, and the venous
pressure was not a function of Pra. Jugular veins collapse when
elevated above the heart, such as in the sitting position. These veins
will then behave as a Starling resistor. In part I of this
study, with PEEP elevated to 35 cmH2O, sagittal sinus
pressure (Pcev), which could be referred to as the upstream pressure
(as explained in the Starling resistor model), was not affected by the
increase in Pra (the downstream pressure) up to 13 mmHg.
Jugular venous pressure, however, measured at the level of the mandible
(20 cm above the right atrium and ~8 cm below the level of the
sagittal sinus) increased when Pra was increased to 10 mmHg. Similarly,
jugular venous pressure measured at an even lower level (Plj; 10 cm
above the right atrium) increased when Pra increased to only 7.5 mmHg.
These data suggest that the jugular veins collapsed at the thoracic
inlet. From part II of our study, it is clear that Pcev could
be elevated when Pra was increased to
20 mmHg by the addition of a
pressurized chest binder to augment the Pra increase. These results
suggest that the back pressure to overcome the closing pressure is
~20 mmHg.
In the sitting position, or head-elevated position, in humans, cerebral venous blood exits through the internal jugular veins, emissary veins, and vertebral venous plexus. Epstein et al. (4) demonstrated in monkeys in the erect position that cerebral venous blood drains primarily from the vertebral venous system with little from the jugular veins and that the proportion of outflow depended on the airway pressure. Eckenhoff (3) explained that cerebral venous outflow is a dynamic state: during expiration, high-intrathoracic pressure causes a major proportion of blood to drain via the vertebral plexus; during inspiration, low-intrathoracic pressure causes blood to drain freely from both the jugular veins and vertebral plexus. During forced expiration, such as during heavy lifting, or when the chest is splinted, high-intrathoracic pressure stops the return of blood via the jugular veins. All cerebral venous blood then flows into the vertebral plexus and out into other venous beds. The vertebral venous plexus has been described as an enormous, valveless, thin-walled vascular bed contained within the spinal canal that courses between and parallel to the bodies of the vertebrae (1). Blood is free to flow in and out of these veins as directed by pressure gradients. Because these venous plexus do not directly connect to the superior vena cava, they are not subjected to immediate intrathoracic pressure variations. These two unique characteristics, its large capacitance and its indirect connection with the superior vena cava, may also partially explain why pressure transmission is less effective in the head-elevated position. Because the proportion of cerebral venous blood draining through the vertebral plexus was not investigated in this study, it is difficult to determine how much of the increased Pra was transmitted via this route.
Hibino and Matsmura (8), studying the effect of PEEP on Pcev in the
seated dog, noted that the effect is variable. The effects of PEEP
depend largely on the route of cerebral venous blood outflow: PEEP
increases Pcev only when blood flows in the noncollapsed vertebral
vessels, whereas, when blood flows primarily in the collapsed jugular
veins, Pcev frequently decreased further. Contrary to their finding,
our laboratory's previous study (16) in dogs in the head-elevated
position demonstrated that, despite the low initial Pcev (less than
4.0 mmHg), PEEP up to 20 cmH2O (Pra = 6 mmHg) did
not elevate Pcev, but compression of the jugular veins (20 mmHg) did so
rapidly and significantly. This indicates that the jugular veins may
have collapsed but that blood flow did not cease.
In the present study, we investigated the Starling resistor effect in determining the effect of PEEP on Pcev in dog in the head-elevated position. We demonstrated that PEEP up to 35 cmH2O had no effect on Pcev but effectively elevated jugular venous pressure (depending on the level at which the pressure was measured). When the PEEP-induced increase in Pra was further increased with a chest binder, and when it exceeded the closing pressure of the collapsed jugular veins, PEEP then increased Pcev. These findings can be interpreted, in clinical settings, to mean that PEEP may be beneficial in preventing venous air entrainment for cervical spine surgery (where the site of surgery is not as highly located as the head from the heart) in the sitting position.
The results of this and previous studies from our laboratory indicate that PEEP is ineffective in raising Pcev for prophylaxis of venous air embolism in the head-elevated position. Even a very high level of PEEP (35 cmH2O) does not raise Pcev, and this level of PEEP may result in a marked reduction in systemic arterial blood pressure and cardiac output such that cerebral blood flow may be reduced. Acute elevation of Pcev may be best achieved in the clinical setting with manual compression of the jugular veins or with a carefully regulated neck-cuff occluder.
| |
ACKNOWLEDGEMENTS |
|---|
This study was supported by National Institute of Neurological Disorders and Stroke Grant NS-20020.
| |
FOOTNOTES |
|---|
Address for reprint requests and other correspondence: T. J. K. Toung, 600 N. Wolfe St., Meyer 8-134, Baltimore, MD 21287-7834.
Received 15 August 1997; accepted in final form 25 October 1999.
| |
REFERENCES |
|---|
|
|
|---|
1.
Batson, O. V.
The vertebral vein system.
Am. J. Roentgenol.
78:
195-212,
1957.
2.
Chapin, J. C.,
J. B. Downs,
M. E. Douglas,
E. J. Murphy,
and
B. C. Ruiz.
Lung expansion, airway pressure transmission, and positive end-expiratory pressure.
Arch. Surg.
114:
1193-1197,
1979[Abstract].
3.
Eckenhoff, J. E.
The physiologic significance of the vertebral venous plexus.
Surg. Gynecol. Obstet.
131:
72-78,
1970[ISI][Medline].
4.
Epstein, H. M.,
H. W. Linde,
A. R. Crampton,
I. S. Ciric,
and
J. E. Eckenhoff.
The vertebral venous plexus as a major cerebral venous outflow tract.
Anesthesiology
32:
332-338,
1970[ISI][Medline].
5.
Fisher, J.,
F. Vaghaiwalla,
J. Tsitlik,
H. Levin,
J. Brinker,
M. Weisfeldt,
and
F. Yin.
Determinants and clinical significance of jugular venous calve competence.
Circulation
65:
188-196,
1982
6.
Guerci, A. D.,
A.-Y. Shi,
H. Levin,
J. Tsitlik,
M. L. Weisfeldt,
and
N. Chandra.
Transmission of intrathoracic pressure to the intracranial space during cardiopulmonary resuscitation in dogs.
Circ. Res.
56:
20-30,
1985
7.
Hewer, A. J. H.,
and
V. Logue.
Methods of increasing the safety of neuroanesthetics in the sitting position.
Anaesthesia
17:
476-481,
1962[ISI][Medline].
8.
Hibino, H.,
and
M. Matsmura.
Cerebral venous sinus pressure in seated dogs: impact of PEEP, cervical venous compression, and abdominal compression.
Anesthesiology
63:
184-189,
1985[ISI][Medline].
9.
Holt, J. P.
The collapse factor in the measurement of venous pressure.
Am. J. Physiol.
134:
292-299,
1941.
10.
Holt, J. P.
The effect of positive and negative intrathoracic pressure on peripheral venous pressure in man.
Am. J. Physiol.
139:
208-211,
1943.
11.
Huseby, J. S.,
E. G. Pavlin,
and
J. Butler.
Effect of positive end-expiratory pressure on intracranial pressure in dogs.
J. Appl. Physiol.
44:
25-27,
1978
12.
Iwabuchi, T.,
E. Sobata,
M. Suzuki,
S. Suzuki,
and
M. Yamashita.
Dural sinus pressure as related to neurosurgical positions.
Neurosurgery
12:
203-207,
1983[ISI][Medline].
13.
Lopez-Muniz, R.,
N. L. Stephens,
B. Bromberger-Barnea,
S. Permutt,
and
R. L. Riley.
Critical closure of pulmonary vessels analyzed in terms of Starling resistor models.
J. Appl. Physiol.
24:
625-635,
1968
14.
Luce, J. M.,
J. S. Huseby,
W. Kirk,
and
J. Butler.
Mechanism by which positive end-expiratory pressure increases cerebrospinal fluid pressure in dogs.
J. Appl. Physiol.
52:
231-235,
1982
15.
Myerson, A.,
and
J. Loman.
Internal jugular venous pressure in man.
Arch. Neurol. Psychiatry
27:
836-846,
1931.
16.
Toung, T.,
Y. K. Ngeow,
D. L. Long,
M. C. Rogers,
and
R. J. Traystman.
Comparison of the effects of positive end-expiratory pressure and jugular venous compression on canine cerebral venous pressure.
Anesthesiology
61:
169-172,
1984[ISI][Medline].
17.
Voorhies, R. M.,
R. A. R. Fraser,
and
A. V. Poznak.
Prevention of air embolism with positive end-expiratory pressure.
Neurosurgery
12:
502-506,
1983.
This article has been cited by other articles:
![]() |
N. H. Secher, T. Seifert, and J. J. Van Lieshout Cerebral blood flow and metabolism during exercise: implications for fatigue J Appl Physiol, January 1, 2008; 104(1): 306 - 314. [Abstract] [Full Text] [PDF] |
||||
![]() |
J Gisolf, J. J van Lieshout, K van Heusden, F Pott, W. J Stok, and J. M Karemaker Human cerebral venous outflow pathway depends on posture and central venous pressure J. Physiol., October 1, 2004; 560(1): 317 - 327. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. A. Dawson, N. H. Secher, M. K. Dalsgaard, S. Ogoh, C. C. Yoshiga, J. Gonzalez-Alonso, A. Steensberg, and P. B. Raven Standing up to the challenge of standing: a siphon does not support cerebral blood flow in humans Am J Physiol Regulatory Integrative Comp Physiol, October 1, 2004; 287(4): R911 - R914. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Pott, J. J. Van Lieshout, K. Ide, P. Madsen, and N. H. Secher Middle cerebral artery blood velocity during intense static exercise is dominated by a Valsalva maneuver J Appl Physiol, April 1, 2003; 94(4): 1335 - 1344. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. J. Van Lieshout, W. Wieling, J. M. Karemaker, and N. H. Secher Syncope, cerebral perfusion, and oxygenation J Appl Physiol, March 1, 2003; 94(3): 833 - 848. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. J. Brosnan, E. P. Steffey, R. A. LeCouteur, A. Imai, T. B. Farver, and G. D. Kortz Effects of body position on intracranial and cerebral perfusion pressures in isoflurane-anesthetized horses J Appl Physiol, June 1, 2002; 92(6): 2542 - 2546. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. J. Schmitt and T. M. Hemmerling Venous Air Emboli Occur During Release of Positive End-Expiratory Pressure and Repositioning After Sitting Position Surgery Anesth. Analg., February 1, 2002; 94(2): 400 - 403. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Georgiadis, S. Schwarz, R. W. Baumgartner, R. Veltkamp, and S. Schwab Influence of Positive End-Expiratory Pressure on Intracranial Pressure and Cerebral Perfusion Pressure in Patients With Acute Stroke Stroke, September 1, 2001; 32(9): 2088 - 2092. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| Visit Other APS Journals Online |