|
|
||||||||
1 Department of Chemical Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802; and 2 Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139
| |
ABSTRACT |
|---|
|
|
|---|
The ability to deliver proteins and peptides to the systemic circulation by inhalation has contributed to a rise in the number of inhalation therapies under investigation. For most of these therapies, aerosols are designed to comprise small spherical droplets or particles of mass density near 1 g/cm3 and mean geometric diameter between ~1 and 3 µm, suitable for particle penetration into the airways or lung periphery. Studies performed primarily with liquid aerosols have shown that these characteristics of inhaled aerosols lead to optimal therapeutic effect, both for local and systemic therapeutic delivery. Inefficient drug delivery can still arise, owing to excessive particle aggregation in an inhaler, deposition in the mouth and throat, and overly rapid particle removal from the lungs by mucocilliary or phagocytic clearance mechanisms. To address these problems, particle surface chemistry and surface roughness are traditionally manipulated. Recent data indicate that major improvements in aerosol particle performance may also be achieved by lowering particle mass density and increasing particle size, since large, porous particles display less tendency to agglomerate than (conventional) small and nonporous particles. Also, large, porous particles inhaled into the lungs can potentially release therapeutic substances for long periods of time by escaping phagocytic clearance from the lung periphery, thus enabling therapeutic action for periods ranging from hours to many days.
inhalation therapies; respiratory illness; aerosol particles
| |
INTRODUCTION |
|---|
|
|
|---|
DRUG DELIVERY TO THE LUNGS by inhalation has attracted tremendous scientific and biomedical interest in recent years. This trend accompanies a rise in respiratory illnesses, dramatized by an increase in asthma population in the United States of 46% between 1982 and 1993 (Centers for Disease Control and Prevention, Atlanta, GA). Of at least equal impact has been the development of many new biotherapeutics (primarily peptide and protein drugs) that in most cases can be delivered to humans only by intravenous injection, often with low patient compliance. To avoid needles, noninvasive delivery strategies have been extensively explored. Among these, inhalation delivery has proven especially attractive, since the epithelium of the human lungs is highly permeable and easily accessed by an inhaled dose (7, 15, 23, 24, 26, 30).
While promising, inhalation therapy is not yet optimized (22). In many
cases, the loss of efficiency or reproducibility that this lack of
optimization entails can preclude inhalation as a practical noninvasive
human therapy. Presently, this is true for many biotherapeutics
currently injected intravenously, like growth hormone, glucagon, or
1-antitrypsin, each of which
could possibly be delivered to humans by inhalation were the efficiency of inhalation therapy greater. Losses of inhaled therapeutic can be
attributed to a variety of factors; for example, inhaled aerosol particles must possess a very narrow range of "aerodynamic
diameters" (related to a particle's geometric diameter and mass
density) to pass through the filter of the mouth and throat. Even if
properly designed and produced, aerosol particles may be propelled with too high a velocity and consequently deposited in the mouth
and throat by inertia. Once in the lungs, particles must release the therapeutic substance at a desired rate and, in some cases, escape the
lungs' natural clearance mechanisms until their therapeutic payload
has been delivered.
To meet these challenges, new inhaler devices have been, and continue to be, developed. These fall in the categories of metered-dose inhalers, dry-powder inhalers, and nebulizers (14, 21, 32). When combined with optimized aerosol formulations, these new inhalers promise to significantly expand the use of inhalation therapy in humans (20).
Among the factors that can be adjusted to optimize the efficiency of aerosol formulations, particle chemistry and surface morphology (manipulated to reduce particle-particle aggregation or hygroscopicity) and particle solubility (altered to influence the rate of therapeutic release) are rather well documented (10, 11). Less well documented is the potential for major improvements in aerosolization efficiency by diminishing aerosol particle mass density and increasing particle size, as done in recent studies for select formulations (6, 35). The delivery of large, porous particles to the lungs may also permit exceptionally long-acting therapeutic delivery following inhalation, as further described in this review.
| |
THE AERODYNAMIC DIAMETER WINDOW |
|---|
To understand the rationale behind therapeutic aerosol particle design, it is helpful to briefly review the concept of aerodynamic diameter and its relation to the pattern of particle deposition in the lungs. Aerodynamic diameter is the geometric diameter a particle appears to possess on the basis of its in-flight speed, were it assumed to be spherical and to possess a mass density of 1 g/cm3; stated differently, the geometric diameter of a spherical particle possessing unit mass density (1 g/cm3) is equivalent to its aerodynamic diameter. Because many naturally occurring particles possess a mass density near this value and because sphericity is a tendency of nature based on surface energetic considerations, such a "base-case" particle has proven useful for discussing the sites and extent of aerosol particle deposition in the lungs as a function of particle size.
A more quantitative idea of aerodynamic diameter can be gathered by imagining a spherical particle falling under gravity through air; so long as the characteristic particle size is substantially larger than the mean free path of the surrounding air molecules, it can be shown that the particle will settle with a velocity (v)
|
),
this gives
|
(1) |
and the square of their geometric diameter
(d2). If we
consider the heuristic definition of aerodynamic diameter provided
above, it is possible to rewrite Eq. 1
in terms of the particle's aerodynamic diameter, as
|
(2) |
a = 1 g/cm3, and where we have defined
the aerodynamic diameter
(da) by the
relationship
|
(3a) |
|
(3b) |
will settle with a velocity that depends only on its aerodynamic diameter da,
i.e., is dependent on size and mass density through the specific
relation of Eq. 3. Modifications to
Eq. 3 arise for nonspherical particles
(10); these modifications can include more than a single aerodynamic
coefficient, particularly in the case of nonisotropic particles (e.g.,
cylinders), wherein the particles translate with a preferred
orientation.
Because gravitational settling constitutes one of the principal mechanisms of aerosol particle deposition in the lungs, the concept of aerodynamic diameter becomes a useful intrinsic particle property with which to discuss a particle's expected lung deposition performance following inhalation. Moreover, as shown by Landahl (17) in his landmark study of aerosol particle deposition in the lungs, the second principal mechanism of particle deposition in the lungs, inertial impaction, also depends uniquely on da (see Fig. 1, reproduced from Ref. 9). Aerodynamic diameter has thus been used for several decades to quantify an aerosol particle's inherent propensity to deposit in the lungs, essentially independently of its shape, mass density, and (in principle) geometric size.
|
Numerous experimental (2, 5, 12, 19) and theoretical (3, 9, 13) studies have demonstrated that particles of mean aerodynamic diameter of 1-3 µm deposit minimally in the mouth and throat and maximally in the lung's parenchymal (i.e., alveolar or "deep-lung") region. Tracheobronchial deposition, generally not desired for an inhalation therapy, is maximized for aerodynamic diameter between ~8 and 10 µm. Particles possessing an aerodynamic diameter smaller than ~1 µm (although greater than several hundred nanometers) are mostly exhaled, and particles larger than ~10 µm have little chance of making it beyond the mouth.
The aerodynamic diameter window of 1-3 µm has also proven optimal for inhalation drug delivery. By using liquid aerosols (whence aerodynamic and geometric diameters coincide) Clay et al. (4) found that optimal bronchodilation in human asthmatics occurred after inhalation of 1.8-µm-diameter (terbutaline) droplets, relative to droplets of 4.6 or 10.3 µm in diameter (all other factors held constant). Johnson et al. (16) and Ruffin et al. (28), respectively, showed that liquid aerosols comprising 3.3-µm (salbutamol) and 1.5-µm (isoproterenol) droplets also produced greater bronchodilation in human asthma patients than did droplets substantially larger than 3 µm. Also, Zanen et al. (37, 38) in two separate studies found that 2.8-µm aerosols of salbutamol and ipratropium bromide produce greater bronchodilation than droplets of larger or smaller size (although little difference was seen between the 1.5- and 2.8-µm ipratropium bromide aerosols). The aerodynamic diameter window of 1-3 µm has also been shown to be optimal for systemic delivery in dogs after inhalation of leuprolide acetate (liquid) aerosols (1).
Given that most published studies of particle size effect on therapeutic efficacy have used approximately spherical aerosol particles of mass density near unity (1 g/cm3) and considering that manipulation of aerodynamic diameter by particle mass density has tended to be viewed as hard to achieve (10, 11), the aerodynamic diameter window of 1-3 µm has become associated in many published research articles with an intrinsic geometric diameter window in the same range (1-3 µm) (1, 30). This partly explains why therapeutic aerosol particles are primarily designed today with geometric diameters in the range of 1-3 µm, even though aerosol particles of much larger size (and lower mass density) can be encountered in the environment and often enter into the lungs. This latter point is reflected in the following list of airborne particles (note that increasing particle size generally coincides with diminishing mass density, in accordance with the relationship indicated by Eq. 3) (25, 33): pollen (10-100 µm), natural fog (2-80 µm), coal dust (3-30 µm), and metal fumes (0.01-100 µm).
| |
THE BIOAVAILABILITY QUESTION |
|---|
To further clarify the optimal characteristics sought in an "ideal" therapeutic aerosol formulation, we review one of the major driving forces for the expanding use of inhaled therapies; namely, to replace injectables with an easy-to-use, affordable, noninvasive delivery technology.
Intravenous (iv) injection, the primary route of protein therapeutic administration, is painful, and patient compliance is often low as a consequence; several excellent reviews have documented the case for pulmonary administration as a practically viable alternative (22, 30, 34). Relative to oral administration, pulmonary delivery exposes the administered drug to a less harsh environment, and the permeability of the alveolar epithelium is high. Compared with the sites of transdermal, nasal, vaginal, buccal, or ocular delivery, the exposed surface area of the lungs is extremely large, estimated to approximate the area of a tennis court (22).
The efficiency of drug delivery by a noninvasive route can be expressed in terms of bioavailability (B) defined as
|
(4) |
|
(5) |
|
Together with the question of appropriate pharmacokinetics, the
question of bioavailability is central to the viability of a systemic
inhalation therapy. Given a required dose to be administered to the
systemic circulation, as well as the acceptable dose variability and
upper limit on the amount of mass that can be inhaled into the lungs at
any one time without unwanted side-effects such as coughing (e.g.,
~20 mg), a practical lower limit is placed on B, below which
inhalation is an unacceptable alternative to iv injection. This value
may be, for example, 1, 10, or 30%, depending on the drug and therapy,
with the understanding that an increase in B value above this
theoretical minimum will always tend to benefit the therapy by
decreasing cost and likely increasing reproducibility. In the case of
insulin, widely studied for its role in the chronic treatment of
diabetes, reproducibility must be especially high to avoid hypoglycemic
shock. Sufficient bioavailability and reproducibility have, however,
been observed in human insulin trials (29) to justify hopes that an
inhalation insulin therapy may soon reach the commercial US market.
Calcitonin, interferons, parathyroid hormone, and leuprolide are also
in human clinical trials for systemic action after inhalation. On the
other hand, proteins such as glucagon (used to treat hypoglycemic
coma),
1-antitrypsin (used for
the treatment of emphysema), or growth hormone (used for the treatment
of growth deficiency), while attractive molecules for inhalation, have
not yet reached the human trial stage.
A second key element to inhalation therapy concerns pharmacokinetic profile following administration. Lacking control over delivery by a long-lived, controlled-release particle, the systemic delivery rate of drugs from the lungs depends strongly on molecular size and structure, as indicated by the varied plasma absorption times listed in Table 1. A drug's intrinsic absorption profile may, however, not perfectly suit the required therapy, as is the case for sustained release of insulin for diabetic patients (29). A sustained-release inhaled therapeutic particle might serve to change the pharmacokinetic plasma profile, making it more suitable to the particular therapy. Sustained release from an inhaled therapeutic particle may also help to improve the bioavailability of very large proteins, such as IgG (Table 1), that absorb extremely slowly into the systemic circulation from the lungs. To the extent that the low bioavailability of slowly absorbing macromolecules can be attributed to long residence time in the alveolar fluid before absorption, during which time activity is lost by enzymatic degradation or aggregation, a controlled-release form of the drugs might again be beneficial. By controlling the release of a drug from an inhaled particle such that it approximates the rate of absorption into the bloodstream, the overall bioavailability of the drug might be increased without necessarily altering the pharmacokinetic profile. Hence, whether its purpose is to control the pharmacokinetic profile or to protect a protein over the time period of its absorption, controlled release from an aerosolized particle into the lungs over periods ranging from minutes to, perhaps, many days may be desirable.
Barriers that must be surmounted to achieve high bioavailability and proper pharmacokinetic profile naturally differ with drug but generally include 1) loss of drug owing to filtration of aerosolized dose in the inhaler, mouth, or throat; and 2) clearance of drug from the lungs before drug action. The fact that particles of mean diameter of 1-3 µm are both prone to aggregation and can be rapidly phagocytosed in the deep lungs by alveolar macrophages makes these barriers intrinsically problematic for conventional aerosol particles. For example, by using conventional aerosol particles of 1- to 3-µm size, current inhalers deliver ~10-20% of inhaled drug to the lungs (32). Clearance of drug from the lungs after deposition can include enzymatic degradation, mucocilliary clearance, and phagocytosis. The first of these can be important for molecules like vasoactive intestinal polypeptide (34). Mucocilliary clearance is especially important in the upper and central airways (22), but phagocytosis of slowly soluble particles may be the most significant mechanism of clearance from the deep lungs (6); Gehr et al. (8), for example, report that approximately one-third of polystyrene particles are immediately phagocytosed after inhalation into the lungs of hamsters. This rapid clearance acts against the potential benefits of an inhaled particle with controlled-release features, rendering sustained release of drugs into or from the lungs hard to achieve with current inhalation aerosol particles.
| |
ADVANTAGE OF LARGE AND POROUS AEROSOL PARTICLES |
|---|
A new type of inhalation aerosol has recently been identified that may help to address limitations of the current inhalation therapies (6). This aerosol is formed by particles possessing low mass density and, consequently, large size, such that the particles' mean aerodynamic diameter fits into the window of 1-3 µm. The advantage of large size and low mass density is twofold: first, increased particle size results in decreased tendency to aggregate; hence, in combination with low mass density, this leads to more efficient aerosolization in a given air field; second, since phagocytosis of particles by macrophages diminishes with increasing particle size beyond ~2-3 µm (27, 31), very large particles deposited in the pulmonary region may escape clearance by alveolar macrophages and, therefore, permit drug release for longer periods of time and more efficiently.
To clarify the potential for large and porous aerosols to increase systemic bioavailability as well as to provide sustained-release capability in the lungs, Edwards et al. (6) encapsulated insulin into a biodegradable copolymer commonly used in biodegradable sutures and in controlled-release, implantable or injectable depot systems (18). Poly(lactic-co-glycolic) acid polymer particles were prepared with encapsulated insulin in two forms: a small, nonporous (conventional) aerosol particle and a large, porous (novel) aerosol particle of similar da (2.15 µm). Relative bioavailability of the conventional aerosol particle after aerosolization as a dry powder into the lungs of rats was 12%, and the release time was ~4 h. Figure 2 shows that insulin release into the systemic circulation from the large and porous aerosol particle lasted ~96 h, with similar inhalation and subcutaneous release profiles. The relative bioavailability (cf. Eq. 5) of the large and porous insulin particle was 87.5%, about seven times greater than that of the small and nonporous insulin particle.
|
One reason for the relatively high bioavailability of the inhaled large-particle insulin is more efficient delivery of drug to the lung as a consequence of less powder aggregation (6). An increase in the size of aerosol particles results in a reduced fractional surface area (or likelihood) of particle-particle contact in a dry powder (or liquid suspension) and thus in less tendency to aggregate. This diminished aggregation means that less energy is required to aerosolize particles or that particles are more efficiently aerosolized with a given energy of aerosolization.
However, perhaps the predominant cause of the sustained insulin delivery is the role of large particle size in discouraging phagocytosis. In a parallel study (6), the lungs of rats were lavaged both immediately after inhalation and 48 h after inhalation, with an aim to determine the location of the two types of insulin particles in the alveolar fluid. Similar numbers of porous and nonporous particles were inspired into the rat lungs by administering identical masses of porous and nonporous particles into the trachea.1 Immediately after inhalation, 30 ± 3% of macrophages contained insulin particles in the case of rat lungs into which small and nonporous particles had been inspired, compared with 8 ± 2% of macrophages containing large and porous particles. After 48 h, 17.5 ± 1.5% of macrophages contained three or more small and nonporous particles compared with 4 ± 1% of macrophages containing three or more large and porous particles. Figure 3B shows two alveolar macrophages 48 h after inhalation of the small and nonporous insulin particles. Each macrophage contains numerous particles. Figure 3C shows several alveolar macrophages 48 h after inhalation of the large and porous insulin particles. The macrophages surround a large, porous particle without, however, engulfing it; other particles can be seen along the periphery of the macrophages. The lower extent of particle phagocytosis in the case of the large and porous therapeutic particles accompanies a relatively low inflammatory response as well. These results support the findings of in vitro experimental studies, cited above (27, 31), that show a trend of diminished particle phagocytosis with increasing particle size beyond ~3 mm.
|
The potential of large, porous particles for inhalation of a variety of drugs is presently being explored. In addition to insulin and testosterone (6), promising results in animals have recently been obtained with long-lasting formulations of estradiol (35), for hormone therapy, and albuterol (35), for asthma. In the estradiol study, particles were produced by spray drying, comprising estradiol and combinations of lung surfactant (dipalmitoylphosphatidylcholine), human albumin, and lactose. Large, porous particles with a mean geometric diameter of 10 µm and bulk (tapped) density 0.09 g/cm3 were prepared, as were nonporous particles possessing a mean geometric diameter of 3 µm and bulk (tapped) density 0.48 g/cm3. After being inspired as an aerosol into the lungs of rats, the large, porous particles produced elevated systemic levels of estradiol for 5 days, whereas the small nonporous particles produced elevated systemic estradiol levels for only 1 day (35). Relative bioavailability in the case of the large, porous estradiol particles was ~87%. In the albuterol study, large, porous particles prepared, again, by spray drying with albuterol and a combination of dipalmitoylphosphatidylcholine, albumin, and lactose resulted in sustained bronchodilation in guinea pigs for ~1 day, at relatively low inhaled albuterol doses, compared with several hours in the case of small, non-sustained-release aerosol particles.
Whereas considerable work remains to clarify the potential bioavailability and efficiency gains that can be achieved after inhalation of large, porous aerosol formulations in humans, the results to date suggest that such particles may play a role in the development and optimization of new inhalation therapies in the future.
| |
FOOTNOTES |
|---|
1
Due to the relatively inefficient
aerosolization properties of the nonporous particles, based on in vitro
and in vivo measurements using particles of similar size and porosity
(6), approximately twice the porous powder mass is estimated to have
entered the lungs relative to nonporous powder mass. At the same time,
the larger size of the porous particles resulted in fewer particles per
powder mass; this can be seen as follows: if 1 and 2 denote porous and
nonporous particles, respectively; N
is the number of particles; d is the
particle diameter; and
is the particle mass density, the porous
powder mass can be represented as
N1(1/6)
1d13
and the nonporous powder mass as
N2(1/6)
2d23.
Accounting for the lesser amount of aerosolized nonporous mass entering
the lungs, and noting Eq. 3a, gives
the relation
N1/N2 ~ 2d2/d1.
Using d1 = 6.8 µm, and d2 = 4.4 µm (6), the ratio of porous to nonporous particle numbers
entering the lungs is near unity
(N1/N2 ~ 1.3).
Address for reprint requests: D. A. Edwards, Advanced Inhalation Research, Inc., 840 Memorial Drive, Cambridge, MA 02139.
| |
REFERENCES |
|---|
|
|
|---|
1.
Adjei, L.,
and
J. Garren.
Pulmonary delivery of peptide drugs: effect of particle size on bioavailability of leuprolide acetate in healthy male volunteers.
Pharm. Res.
7:
565-569,
1990[Medline].
2.
Altschuler, B.,
L. Yarmus,
E. D. Palmes,
and
N. Nelson.
Aerosol deposition in the human respiratory tract.
Am. Med. Assoc. Arch. Industr. Health
15:
293-303,
1957.
3.
Clark, A. R.,
and
M. Egan.
Modelling the deposition of inhaled powdered drug aerosols.
J. Aerosol Sci.
25:
175-186,
1994.
4.
Clay, M. M.,
D. Pavia,
and
S. W. Clarke.
Effect of aerosol particle size on bronchodilation with nebulized terbutaline in asthmatic subjects.
Thorax
41:
364-368,
1986
5.
Davies, C. N.,
J. Heyder,
and
M. C. Subba Ramu.
Breathing of half-micron aerosols. I. Experimental.
J. Appl. Physiol.
32:
591-600,
1972
6.
Edwards, D. A.,
J. Hanes,
G. Caponnetti,
J. Hrkach,
A. Ben-Jebria,
M.-L. Eskew,
J. Mintzes,
D. Deaver,
N. Lotan,
and
R. Langer.
Large porous particles for pulmonary drug delivery.
Science
276:
1868-1871,
1997
7.
Folkesson, H. G.,
B. R. Westrom,
and
B. W. Karlsson.
Permeability of the respiratory tract to different-sized macromolecules after intratracheal instillation in young and adult rats.
Acta Physiol. Scand.
139:
347-354,
1990[Medline].
8.
Gehr, P.,
M. Geiser,
V. Im Hof,
S. Schurch,
U. Waber,
and
M. Baumann.
Surfactant and inhaled particles in the conducting airways: structural, stereological, and biophysical aspects.
Microsc. Res. Tech.
26:
423-436,
1993[Medline].
9.
Gerrity, T. R.,
P. S. Lee,
F. J. Hass,
A. Marinelli,
P. Werner,
and
R. V. Lourenco.
Calculated deposition of inhaled particles in the airway generations of normal subjects.
J. Appl. Physiol.
47:
867-873,
1979
10.
Gonda, I.
Physicochemical principles in aerosol delivery.
In: Topics in Pharmaceutical Sciences 1991, edited by D. J. A. Crommelin,
and K. K. Midha. Stuttgart, Germany: Medpharm Scientific, 1992, p. 95-115.
11.
Gonda, I.
Targeting by deposition.
In: Pharmaceutical Inhalation Aerosol Technology, edited by A. J. Hickey. New York: Dekker, 1992, p. 61-82.
12.
Heyder, J.,
L. Armbruster,
J. Bebhart,
E. Grein,
and
W. Stahlhofen.
Total deposition of aerosol particles in the human respiratory tract for nose and mouth breathing.
J. Aerosol Sci.
6:
311-328,
1975.
13.
Heyder, J.,
and
G. Rudolf.
Mathematical models of particle deposition in the human respiratory tract.
J. Aerosol Sci.
15:
697-707,
1984.
14.
Hickey, A. J.,
and
R. M. Evans.
Aerosol generation from propellant-driven metered dose inhalers.
In: Inhalation Aerosols, edited by A. J. Hickey. New York: Dekker, 1996, p. 417-439.
15.
Hubbard, R. C.,
M. A. Casolaro,
M. Mitchell,
S. E. Sellers,
F. Arabia,
M. A. Matthay,
and
R. G. Crystal.
Fate of aerosolized recombinant DNA-produced alpha-I-antitrypsin: use of the epithelial surface of the lower respiratory tract to adminster proteins of therapeutic importance.
Proc. Natl. Acad. Sci. USA
86:
680-684,
1984.
16.
Johnson, M. A.,
S. P. Newman,
R. Bloom,
N. Talee,
and
S. W. Clarke.
Delivery of albuterol and ipratropiumbromide from two nebulizer systems in chronic stable asthma.
Chest
96:
6-10,
1989
17.
Landahl, H. D.
On the removal of air-borne droplets by the human respiratory tract. I. The lung.
Bull. Math. Biophys.
12:
43-56,
1950.
18.
Langer, R.
Polymer controlled drug delivery systems.
Accounts Chem. Res.
26:
537-542,
1993.
19.
Muir, D. C. F.,
and
C. N. Davies.
The deposition of 0.5 µm diameter aerosols in the lung of man.
Ann. Occup. Hyg.
10:
161-174,
1967.
20.
Niven, R.
Delivery of biotherapeutics by inhalation aerosol.
Crit. Rev. Ther. Drug Carrier Syst.
12:
151-173,
1995[Medline].
21.
Niven, R. W.
Atomization and nebulization.
In: Inhalation Aerosols, edited by A. J. Hickey. New York: Dekker, 1996, p. 273-312.
22.
Patton, J.
Mechanisms of macromolecule absorption by the lung.
Adv. Drug Delivery Res.
19:
3-36,
1996.
23.
Patton, J. S.,
H. J. Fuchs,
J. A. Moore,
H. Gustafson,
G. A. Keller,
and
A. L. Daugherty.
Pulmonary delivery of peptide and protein drugs.
Proc. Int. Symp. Control. Rel. Bioact. Mater.
17:
214-215,
1990.
24.
Patton, J. S.,
P. Trinchero,
and
R. M. Platz.
Bioavailability of pulmonary delivered peptides and proteins:
-interferon, calcitonins and parathyroid hormones.
J. Contr. Rel.
28:
79-85,
1994.
25.
Phalen, R. F.
Inhalation Studies: Foundations and Techniques. Boca Raton, FL: CRC Press, 1984.
26.
Richardson, J.,
T. Bourchard,
and
C. C. Ferguson.
Uptake and transport of exogenous proteins by respiratory epithelium.
Lab. Invest.
35:
307-314,
1976[Medline].
27.
Rudt, S.,
H. Wesemeyer,
and
R. H. Muller.
In vitro phagocytosis assay of nano- and microparticles by chemiluminescence. IV. Effect of surface modification by coating of particles with poloxamine and Antarox CO on the phagocytic uptake.
J. Contr. Rel.
25:
123-138,
1993.
28.
Ruffin, R. E.,
M. B. Dolovich,
F. A. Oldenburg,
and
M. T. Newhouse.
The preferential deposition of inhaled isoproterenol and propanolol in asthmatic patients.
Chest
80:
904-907,
1986[Abstract].
29.
Service, R. F.
Drug delivery takes a deep breath.
Science
277:
1199-1201,
1997
30.
Smith, P. L.
Peptide delivery via the pulmonary route: a valid approach for local and systemic delivery.
J. Contr. Rel.
46:
90-106,
1997.
31.
Tabata, Y.,
and
Y. Ikada.
Effect of size and surface charge of polymer microspheres on their phagocytosis by macrophage.
J. Biomed. Mater. Res.
22:
837-842,
1988[Medline].
32.
Timsina, M. P.,
G. P. Martin,
C. Marriott,
P. Ganderton,
and
M. Yianneskis.
Drug delivery to the respiratory tract using dry powder inhalers.
Int. J. Pharmacol.
101:
1-13,
1994.
33.
Vincent, J. J.
Aerosol Science for Industrial Hygienists. New York: Pergamon, 1995.
34.
Wall, D. A.
Pulmonary absorption of peptides and proteins.
Drug Delivery
2:
1-10,
1995.
35.
Wang, J.,
A. Ben-Jebria,
and
D. A. Edwards.
Controlled-release inhalation aerosols.
In: Respiratory Drug Delivery. Buffalo Grove, IL: Interpharm, 1997, vol. VI, p. 187-192.
36.
Wigley, F. M.,
X. J. H. Londono,
S. H. Wood,
J. C. Shipp,
and
R. H. Waldman.
Insulin across respiratory mucosae by aerosol delivery.
Diabetes
20:
552-556,
1971[Medline].
37.
Zanen, P.,
L. T. Go,
and
J.-W. J. Lammers.
The optimal particle size for beta adrenergic aerosols in mild asthmatics.
Int. J. Pharmacol.
107:
211-217,
1994.
38.
Zanen, P.,
L. T. Go,
and
J.-W. J. Lammers.
The optimal particle size for parasympathicolytic aerosols in mild asthmatics.
Int. J. Pharmacol.
4:
111-115,
1995.
This article has been cited by other articles:
![]() |
O. V. Evgenov, D. S. Kohane, K. D. Bloch, J.-P. Stasch, G. P. Volpato, E. Bellas, N. V. Evgenov, E. S. Buys, M. J. Gnoth, A. R. Graveline, et al. Inhaled Agonists of Soluble Guanylate Cyclase Induce Selective Pulmonary Vasodilation Am. J. Respir. Crit. Care Med., December 1, 2007; 176(11): 1138 - 1145. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. C. Huang, A. Vieira, M. K. Yeh, and C. H. Chiang Pulmonary Anti-inflammatory Effects of Chitosan Microparticles Containing Betamethasone Journal of Bioactive and Compatible Polymers, January 1, 2007; 22(1): 30 - 41. [Abstract] [PDF] |
||||
![]() |
B. J. Hoeben, D. S. Burgess, J. T. McConville, L. K. Najvar, R. L. Talbert, J. I. Peters, N. P. Wiederhold, B. L. Frei, J. R. Graybill, R. Bocanegra, et al. In vivo efficacy of aerosolized nanostructured itraconazole formulations for prevention of invasive pulmonary aspergillosis. Antimicrob. Agents Chemother., April 1, 2006; 50(4): 1552 - 1554. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. K. Mandal Inhaled insulin for diabetes mellitus Am. J. Health Syst. Pharm., July 1, 2005; 62(13): 1359 - 1364. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Hochhaus New Developments in Corticosteroids Proceedings of the ATS, November 1, 2004; 1(3): 269 - 274. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Qi, G. Zhao, D. Liu, Z. Shriver, M. Sundaram, S. Sengupta, G. Venkataraman, R. Langer, and R. Sasisekharan Delivery of therapeutic levels of heparin and low-molecular-weight heparin through a pulmonary route PNAS, June 29, 2004; 101(26): 9867 - 9872. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| Visit Other APS Journals Online |