ADDITIONS AND CORRECTIONS TO

Volume 82, May 1997

Pages 1542-1558: A. De Lorenzo, A. Andreoli, J. Matthie, and P. Withers. "Predicting body cell mass with bioimpedance by using theoretical methods: a technological review." The authors noticed several mistakes that do not affect the results but should be corrected nevertheless. On p. 1545: the calculation of fc following modeling was incorrect; hence, the corrected fc values are reprinted below in Table 2. On p. 1553: in Fig. 14, the correct fc values are 124 kHz predialysis and 71 kHz postdialysis; for Table 6, n should be 48, not 73. On p. 1554, left column: line 10, the mean reported for fc should be changed from ~60 kHz to 44 kHz; line 15, the range should read "from 32 to 65 kHz" instead of "from 43 to 110 kHz." On p. 1554, right column: line 29, a mean increase of Cm reported as 64% should read 50%.    

Table  2.   Cole modeling characteristics of TBK and dilution study groups
TBK
Dilution, Men
Men Women Combined

n 63 10 73 14
r of fit 0.9978 ± 0.001 0.9974 ± 0.001 0.9978 ± 0.001 0.9970 ± 0.001
RE, Omega 582.09 ± 47.86 742.81 ± 44.56 604.13 ± 72.81 577.71 ± 44.87
RI, Omega 1,109.04 ± 138.72 1,504.73 ± 209.42 1,163.20 ± 202.79 1,020.42 ± 81.33
Cm, nF 2.32 ± 0.43 1.27 ± 0.26 2.18 ± 0.55 2.24 ± 0.30
 alpha 0.70 ± 0.02 0.68 ± 0.03 0.70 ± 0.03 0.68 ± 0.01
fc, kHz 41.86 ± 6.06 58.41 ± 11.94 44.13 ± 9.15 45.86 ± 4.31
Td, ns 20.66 ± 8.46 32.40 ± 9.43 22.26 ± 9.49  -3.27 ± 4.37

Values are means ± 1 SD. n, No. of subjects; r, correlation of fit; RE and RI, Cole model electrical resistance terms used to predict volume of ECW and ICW, respectively; Cm, membrane capacitance; alpha , exponent; fc, characteristic frequency; Td, time delay.






This Article
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Search for Related Content


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online