1Department of Biomedical Engineering and 2Department of Chemical Engineering and Materials Science, University of California, Irvine, Irvine, California
Submitted 20 December 2007 ; accepted in final form 10 March 2008
| ABSTRACT |
|---|
|
|
|---|
asthma; inflammation; model; multicompartment
NO exchange in the lungs exhibits two distinguishing features that need to be considered for a proper interpretation of the exhaled signal. First, exhaled NO is produced in both the airway and alveolar regions of the lung (18, 20, 28, 30). Second, exhaled NO concentration is highly dependent on the exhalation flow (25, 30). In a disease such as asthma, inflammation and flow are spatially heterogeneous. As a result, the exhaled NO concentration may increase or decrease during the course of an exhalation even when flow is held constant. Thus far, mathematical models of NO exchange dynamics in the lungs have apportioned NO exchange into one airway and one alveolar compartment, each having homogeneous ventilation and NO production (4, 8, 19, 23, 26, 28, 31). Such models effectively simulate the flow dependence of exhaled NO but are unable to describe variations in NO concentration when flow is held constant.
While asthma has traditionally been considered to be a disease of the proximal/conducting airways (generations 0–16), recent studies have indicated significant inflammation of the distal/acinar airways and alveolar regions (generations 17–23) (6, 9, 10, 17). Imaging and multiple-breath washout studies have also demonstrated ventilation defects or heterogeneity in the proximal and distal regions of the lung (7, 32, 33, 35). Furthermore, heterogeneity in flow and NO production are likely consequences of heterogeneous inflammation. This study describes a mathematical model of NO exchange in the lungs that incorporates heterogeneity in ventilation and NO production in both the airway and alveolar regions of the lung. Using the simplest such model, we demonstrate that heterogeneity in ventilation and NO production significantly influences the exhaled NO profile in a pattern consistent with experimental observations in asthma.
| Glossary |
|---|
|
|
|---|
ANO

'awNO


III

1(t)
2(t)
1,0
2,0
1,
2,
III


1(t) and
2(t) (s)
| METHODS |
|---|
|
|
|---|
|
0z A(s)ds. The volume of the conducting airways (generations 0–16) in the Weibel model is approximately equal to 175 cm3. The linear dimension of the Weibel data was scaled by (181/175)1/3 to simulate a lung with a total airway volume Vaw = 181 cm3 that is similar to the group of asthmatic subjects included in this study (see below). For a given subject, Vaw (ml) is fixed at the subject's ideal body weight (pounds) plus age in years (3, 29). The total volume of the alveolar compartments VA was set equal to 2,500 ml to simulate a typical adult functional residual capacity (FRC).
The central airway compartment incorporates the first N generations of the airway tree with volume Vaw0. Distal to generation N, the airway tree is split into two compartments characterized by different flow dynamics. Thus the lower airway compartments incorporate the remaining 17 – N airway generations, but with different cross sections Ai and volumes Vawi (i = 1,2), while the alveolar region is divided into two compartments with volumes VA1 and VA2 and represents a functional division of the lungs into two regions (one well ventilated and the other poorly ventilated). A fraction
of the total cross-sectional area from the Weibel geometry is assigned to compartment 1, and the remainder (1 –
) to compartment 2 so that A1/A2 = Vaw1/Vaw2 = VA1/VA2 =
/(1 –
). The overall length of the airway tree, i.e., the sum of the lengths of compartment 0 and compartments 1 or 2, representing the distance from the oropharynx to the respiratory zone, is equal to that of the Weibel model (appropriately scaled). In this construction, N and
are free structural parameters whose determination is discussed below.
Ventilation.
Compartments 1 and 2 are allowed to empty at different time-dependent rates
1(t) and
2(t) with the constraint that the total exhalation flow at the mouth,
=
1(t) +
2(t), be constant. This choice makes possible the simulation of constant-flow exhalations commonly used to characterize exhaled NO while simultaneously incorporating the effects of ventilation heterogeneity. Then, the flow in compartment i (i = 1,2) is given by (2)
![]() | (1) |
![]() | (2) |
![]() | (3) |
i,0 and
i,
are the initial (t = 0) and steady-state or infinite time (t
) flows in compartment i, and
is a characteristic time constant. These parameters can be expressed in terms of airway resistance (Ri) and tissue elastance (Ei) of compartment i (2), which, in turn, are related to both the geometry (i.e., constriction status) of the airways and the material properties of lung tissue. Importantly, when the total flow
is strictly constant, compartments 1 and 2 are tightly coupled, and the system is characterized by a single time constant
= (R1 + R2)/(E1 + E2). This provides the most flexible structure that may be useful to simulate diseases other than asthma that may have a larger impact on the interstitial tissue. In the case of asthma, flow heterogeneity can be simulated by setting the elastance of the regions to be equal to each other, and then varying the resistance through each compartment. Thus we assume a constant total elastance (ET), or
= 2(R1 + R2)/(ET), consistent with previous reports simulating flow heterogeneity in asthma (27). Using this structure, it can be shown that
1,
=
2,
=
/2. Hence, we treat
1,0 and
as the independent free parameters while
2,0 is determined from the constraint above (Eq. 2). Therefore, the structure and ventilation of the multicompartment model for asthma is characterized by four independent parameters: N,
,
1,0, and
.
NO production.
NO production is characterized by specifying the steady-state NO concentrations CANO,1 and CANO,2 in the alveolar compartments and the maximum airway wall flux J'awNO,i in each airway compartment i (i = 0,1,2). J'awNO,i is obtained by using previously published values of the total airway flux (4, 21–24, 26, 31) and partitioning it between compartments in proportion to their volume:
![]() | (4) |

J'awNO,i. Such a partitioning results in uniform NO production per unit airway volume, and, in combination with the choice CANO,1 = CANO,2, is used to simulate a lung with homogeneous NO production.
Heterogeneous NO production is simulated in three different ways: 1) the airway flux in one of the compartments is specified to be a fraction f of the total flux, and the remaining fraction (1 – f) is partitioned equally between the other two compartments in proportion to their volume; 2) specifying a ratio r of alveolar NO concentrations (r
1), CANO,1 = r x CANO,2, but maintaining a constant volume-weighted alveolar concentration (
ANO = CANO,1 x VA1/VA + CANO,2 x VA2/VA); or 3) a combination of 1 and 2. Thus, for these simulations, NO production is specified by two free parameters (J'awNO,
ANO) in the homogeneous case and four free parameters (J'awNO, f,
ANO, r) in the heterogeneous case.
Governing equations.
The concentration of NO, C(t,z), at time t and axial location z within each compartment is governed by the following convection-diffusion equation (4, 23):
![]() | (5) |
![]() | (6) |
![]() | (7) |
is the total wall flux in the control volume.
Multiple-breath nitrogen washout.
Multiple-breath nitrogen washout (MBNW) is a lung function test used to examine ventilation heterogeneity in the proximal and peripheral airways (12, 14, 15, 35). Briefly, patients tidal-breathe pure O2, and the exhaled concentration of nitrogen is measured, tracking the nitrogen washout from the lungs (Fig. 2A). The normalized phase III slope for nitrogen is positive and progressively increases with each tidal breath (Fig. 2B). The phase III slope of each exhalation is normalized by the mean concentration of the gas over the region of analysis (typically 50–90% of the exhaled volume). Plotting the normalized phase III slope of nitrogen (
) as a function of functional residual capacity turnover (cumulative exhaled volume divided by functional residual capacity) allows quantification of regional ventilation heterogeneity.
|
for early breath numbers is controlled by diffusion and convection-dependent inhomogeneities (DCDI), while
for later breath numbers is controlled by convection-dependent inhomogeneities (CDI) (13–16, 34, 37). These models have been used to explain how the two distinct segments of the
plot represent inhomogeneities in different regions of the lung. Sacin is an index of ventilation inhomogeneity in the acinar airways, while Scond is an index of inhomogeneity in the conducting airways (see schematic in Fig. 2C). We first utilize the multicompartment model to simulate the exchange of nitrogen during a MBNW in order to determine model structural and ventilation parameters independent of the NO exchange parameters. The governing equation is identical to the NO exchange equation (Eq. 5) except the source term is removed. At the start of the washout, the fractional nitrogen concentration in the model is uniform and equal to the atmospheric concentration. During the simulation, tidal volume is assumed to be 1 liter, and flow is saw tooth at ±200 ml/s with a period of 10 s (corresponding to slow deep tidal breathing at a respiratory rate of 6 breaths/min). Boundary conditions during inspiration are adjusted by accounting for the dilution of nitrogen within the alveolar compartments. During expiration, nitrogen concentrations are held fixed at the end-inspiration value. The entire washout is simulated and Sacin and Scond are calculated (Fig. 2). Model-simulated Sacin and Scond are matched to experimentally observed Sacin and Scond in healthy and asthmatic subjects by adjusting the values of the four structural and ventilation parameters using nonlinear regression. Thus we can determine a physiological range for these parameters in healthy and asthmatic subjects. Once the structural and ventilation parameters are determined, we can then simulate the exchange of NO by making the source term nonzero and reverting to the initial and boundary conditions in Eq. 6.
Experimental exhaled NO tracings. Experimental exhaled NO profiles were examined from a previous study investigating the effect of exercise-induced bronchoconstriction on exhaled NO in adults with mild asthma (24). This study enrolled nine subjects with mild exercise-induced bronchoconstriction who managed their symptoms with β-agonists (e.g., Albuterol) only. An inclusion criteria was >10% decrease in FEV1 following the exercise challenge (10 min running on treadmill at 80% of maximum heart rate). The study focused on a single exhalation with a preexpiratory breathhold to characterize airway and alveolar NO parameters, but we also collected exhaled NO at a constant exhalation flow of 50 ml/s according to the guidelines of the American Thoracic Society, both before and after exercise challenge. Details of all nine subjects have been previously reported (24). The protocol was approved by the Institutional Review Board at the University of California, Irvine, and written informed consent was obtained for each subject. Six subjects were able to adequately complete the constant-flow exhalation at a target flow of 50 ml/s both pre- and post-exercise challenge, and these subjects can be summarized by the following indexes (mean ± SD): age, 30 ± 7 yr; height, 1.7 ± 0.12 m; weight, 78 ± 10 kg; Vaw, 178 ± 18 ml; FVC, 89 ± 14%predicted; FEV1, 78 ± 18%predicted; FEV1/FVC, 63 ± 11%; %change in FEV1 following exercise challenge, 25 ± 17%. We did not previously present or analyze the NO tracings (NO concentration as a function of time or exhaled volume) at a constant flow of 50 ml/s.
For exhaled NO tracings, the fractional exhaled NO concentration, FENO, is plotted as a function of exhaled volume (Vex) normalized by an estimate of the subject's airway (dead space) volume (Vaw). In other words, the abscissa is airway volume turnover. The airway volume is estimated by the subject's ideal body weight in pounds plus age in years (3, 29) and thus accounts for variation in size of the subjects. The profile can then be characterized by three indexes consistent with previous reports (4, 30): 1) the fractional concentration of phase III at a constant exhalation flow (FENO,
), defined as the mean concentration over the window 2 < Vex/Vaw < 3; 2) the normalized phase III slope (
IIINO), defined as the slope of the exhaled concentration over the window 2 < Vex/Vaw < 3 divided by FENO,
; and 3) the rise volume (V90NO), defined as the number of exhaled airway volumes needed to reach 90% of FENO,
. In a similar fashion, the mean exhalation flow,
III, and normalized phase III slope of the flow,
III
, can also be defined over the window 2 < Vex/Vaw < 3.
| RESULTS |
|---|
|
|
|---|

and
IIINO are not statistically different from zero (–0.037 ± 0.031 and 0.0067 ± 0.056, respectively), and V90NO is 1.3 ± 0.26 (Fig. 4C).
|
|

,
IIINO, and V90NO after exercise challenge are 23 ± 8.1 ppb, 0.035 ± 0.044, 0.12 ± 0.066, and 1.8 ± 0.2, respectively, which are all statistically different from baseline. Of note,
IIINO is statistically different from zero (positive), but 
is not (Fig. 4, D and E).
Ventilation and structural parameters.
MBNW simulations allow for quantification of the model ventilation and structural parameters. Reported values of Sacin and Scond for both asthmatic and normal subjects were used to generate ventilation and structural parameters for four cases: healthy (Sacin = 0.068, Scond = 0.033), proximal airway heterogeneity (Sacin = 0.068, Scond = 0.060), peripheral airway heterogeneity (Sacin = 0.18, Scond = 0.033), and both proximal and peripheral heterogeneity (Sacin = 0.18, Scond = 0.06) (5, 35–37). We determined optimal values of ventilation and structural parameters (N,
,
1,0, and
) for each of the three cases above (Table 1) using nonlinear regression to obtain the desired values of Scond and Sacin. These simulations were performed before simulating NO exchange. In addition, with the assumption of equal elastances in the two compartments, the steady-state flows in each compartment are equal. Figure 5, A–C, shows the flow through each airway compartment as a function of time for each condition (healthy, abnormal Sacin, abnormal Scond, and abnormal Sacin and Scond). In each case, the flow through compartment 1 is always higher than that in compartment 2, and thus compartment 1 represents the better ventilated region of the lung.
|
|
ANO (3 ppb) where chosen on the basis of reports in the literature for healthy and asthmatic subjects as well as to achieve FENO,50 similar to that observed in our group of asthmatic subjects. The goal of the simulations was not to precisely replicate the experimental tracings but rather to simulate the major features (e.g.,
IIINO).
Figure 6A shows that when NO production is homogeneous (equal volume-weighted airway flux, equal alveolar concentrations), ventilation heterogeneity has only a small effect on the exhaled NO profiles. The healthy case results in a slightly negative phase III slope for NO (
IIINO = –0.002), FENO,50 = 29.5 ppb, and V90NO = 0.675. When a greater degree of heterogeneity is present in either the conducting airways (abnormal Scond), the peripheral region (abnormal Sacin), or both (abnormal Sacin and Scond), there is essentially no change to the exhalation profile.
|
IIINO is near zero for all three cases, but V90NO is increased when the NO flux is weighted in the poorly ventilated compartment 2 (V90NO = 0.8) and decreased when the NO flux is weighted in the central compartment (V90NO = 0.55).
Figure 6C shows the effect of heterogeneous alveolar NO concentrations, which are modest. When the volume-weighted mean alveolar concentration is held constant (3 ppb), but the alveolar concentration is larger in the slow (and smaller) emptying compartment (CANO,1 = 0.94, CANO,2 = 7.5),
IIINO becomes positive, V90NO increases (0.75), and there is a small 3.4% increase in FENO,50 (30.4 ppb). When the fast (and larger) emptying compartment has a larger concentration (CANO,1 = 4.14, CANO,2 = 0.52), the trends are the opposite:
IIINO remains slightly negative, V90NO decreases (0.625), and FENO,50 decreases slightly (1.9% to 29 ppb).
Figure 6, D and E, shows the combined effects of heterogeneity in ventilation and NO production. Although there are many possible combinations, we focused on five illustrative cases that are consistent with the pathophysiology of asthma. Figure 6D combines lower airway ventilation heterogeneity (abnormal Sacin) with either an increased NO airway flux or an increased alveolar concentration in the slower-emptying branch of the model (compartment 2). Figure 6E combines proximal ventilation heterogeneity (abnormal Scond) with an increased NO flux in either the central compartment or the slow-emptying compartment. Figure 6E also includes a simulated tracing for abnormal Sacin and Scond with an increased flux and alveolar concentration in the slow-emptying branch. The latter case simulates global ventilation and inflammation heterogeneity.
Peripheral ventilation heterogeneity with enhanced alveolar NO tends to create a positive
IIINO (0.013) with a small increase in FENO,50 (30.3 ppb). In contrast, peripheral ventilation heterogeneity with enhanced lower airway NO flux significantly right-shifts the profile (V90NO increases to 0.95), enhances
IIINO further (0.017), but decreases FENO,50 by 8.9% (26.9 ppb). Proximal ventilation heterogeneity with NO airway flux weighted in the central compartment significantly enhances FENO,50 (39.8 ppb) and reduces V90NO (0.525). When the NO flux is weighted in the peripheral compartment 2, FENO,50 is reduced by 10.4% and right-shifted (V90NO = 0.875). The most significant effect is observed when both proximal and peripheral ventilation are abnormal, and both the NO airway flux and alveolar concentration are enhanced in compartment 2. For this case, FENO,50 is reduced by 11% (26.2 ppb), and the profile is significantly right-shifted (V90NO = 1.18) with a significant positive
IIINO (0.04).
| DISCUSSION |
|---|
|
|
|---|
Effect of ventilation and NO production heterogeneity. The primary aim of the present study is to illustrate the effect of spatial heterogeneity in ventilation and NO production on exhaled NO dynamics using a simple model. Our results show that the exhaled NO profile is strongly affected by the interplay between structure, ventilation (flow), and NO production.
Both experimental and simulated exhaled NO tracings can be characterized by two phases: 1) a dynamic phase, corresponding to phases I and II of the classic tracing from an inert gas such as N2, in which the exhaled concentration is changing rapidly with time or exhaled volume (characterized by V90NO); and 2) a nearly steady-state phase, corresponding to phase III of an inert gas profile, in which the exhaled concentration approaches a constant (or plateau) value (characterized by FENO,
and
IIINO). The dynamic phase is due to three factors. First, the initial airway compartment that is emptied (Vex/Vaw < 1) has a steep axial gradient of NO beginning with inspired air of zero NO at the mouth and increasing with z-position due to the increased residence time during inspiration. Second, the flow in each compartment is changing in time with a characteristic time constant,
, that captures the resistance of the alveolar and airway regions (Table 1 and Fig. 5). Third, while the airway flux is assumed constant for flows > 50 ml/s, the axial (z position) gradient in NO concentration, which describes axial diffusion of NO (see Eq. 1), is changing in time.
Heterogeneous flow with uniform NO production had only a minimal impact on the exhalation profile of NO. When total flow is held constant, the contribution of the airways to the exhaled concentration is directly related to the residence time of the air within the airway compartment (recall the airway flux in each compartment is an amount of NO per unit time). At early times in Fig. 6 (Vex/Vaw < 0.5), the exhaled NO signal represents the contribution of the central airways (compartment 0). Since the volume and flow, and hence residence time, in this compartment are identical for the three cases, the tracings overlap. At later times the exhaled air consists of a mixture from compartments 1 and 2, whose effective residence time is a flow-weighted combination of residence times in the individual compartments. Differences between the three cases for 0.5 < Vex/Vaw < 3 represent the temporal variation of flows in compartments 1 and 2, and hence effective residence time, in this period (see Fig. 5). Once flow in each compartment is constant (Vex/Vaw > 3), the effective residence time of exhaled air also remains constant, and any further changes in the exhaled concentration with time or exhaled volume are due to changes in the axial gradient.
In contrast to ventilation, NO production heterogeneity had a significant impact on exhaled NO profiles. Different airway fluxes were assigned to different compartments while holding the total airway flux constant. A compartment with a higher flux compared with the homogeneous case could represent a locally inflamed region. This condition resulted in significant alterations to the plateau concentration of NO. When the higher flux was localized to the central airway compartment, the plateau concentration was significantly increased. In contrast, when the higher flux was localized in one of the lower compartments, the plateau concentration was reduced to varying degrees. When the total NO flux is homogeneously distributed, the magnitude of the source term (J'awNO,i/Vaw, flux of NO per unit airway volume) in Eq. 1 is identical in all three airway compartments. When the fraction of the flux assigned to a particular compartment is larger than its fraction of the total airway volume, the source term is disproportionately increased in this compartment and results in a higher NO flux within that compartment. Since the total flux is held constant, this increase is offset by corresponding decreases in the fluxes in the other compartments. However, the contribution of a compartment to the overall exhaled NO depends both on the NO source within that compartment and the flow through it. For example, a compartment with a large source term but zero flow would not contribute to the exhaled NO.
To explain the effect of different spatial flux distributions, we define a flow-weighted average NO source for the whole airway tree as the sum of the source terms in each compartment weighted by the exhalation flow in each compartment:
'awNO = 
(J'awNO,i/Vawi) x (
i/
). When the NO flux is homogeneously distributed (J'awNO,i/Vawi = constant), this quantity is equal to 2 x J'awNO/Vaw, i.e. two times the flux per unit volume of the airway tree. The factor of 2 accounts for the serial nature of the flow between the lower and central compartments.
First consider the case when 70% of the total flux is localized in the central compartment. As the volume of the central compartment (51 ml) represents only 28% of the total airway volume, the flux per unit volume is increased by 150%. Since all the exhaled air passes through this compartment (
=
1 +
2), there is a net increase of 150% in the contribution of the central compartment to
'awNO. This increase is offset by corresponding decreases of the contributions from compartments 1 and 2. However, the net effect is a 46% increase in
'awNO compared with the homogeneous case. In contrast, when 70% of the flux is localized in compartments 1 or 2, similar calculations show that
'awNO is reduced by 11% and 14%, respectively. Thus the magnitude of the decrease depends on the relative flux per unit volume and flows in each compartment. This reasoning does not precisely explain the magnitude of change in FENO,50 when the NO flux is spatially heterogeneous. For instance, when the higher flux is localized in the central compartment, FENO,50 increases by 35% while
'awNO increases by 46%. This is a result of neglecting axial diffusion in defining the effective NO source. Axial diffusion would tend to make the spatial NO concentrations more homogeneous and thus reduce the magnitude of changes compared with the homogeneous case. Nonetheless, this reasoning provides an intuitive explanation of the direction of changes in FENO,50 when the NO flux is spatially heterogeneous.
Distributing the total alveolar concentration heterogeneously has only a modest impact on the exhalation NO profile in these simulations due primarily to the relative contribution (1–8 ppb) of the alveolar NO to FENO (
30 ppb). However, if an inflamed peripheral region (higher alveolar NO concentration) empties slower, the exhaled NO concentration will tend to increase with exhaled volume, creating a positive
IIINO.
The most significant changes in the exhaled NO profile are observed when both NO production and ventilation are heterogeneous. This physiological condition might occur if an inflamed region enhances the production of NO, but also results in bronchoconstriction, thus reducing ventilation. The underlying mechanisms are the same as that discussed for isolated heterogeneity in flow and NO production; that is, the plateau concentration will depend on the relative weighting of the total airway NO flux per unit volume and flow within the airway compartments. Since ventilation is also heterogeneous, there is a larger range of residence times, and thus a larger range of plateau concentrations. For example, when Scond is abnormal, only 5% of the flow (2.5 ml/s) at steady state is in compartment 2 (Table 1). Hence, when 70% of the total airway NO flux is placed in this compartment, the result is a significant decrease in the plateau concentration (Fig. 5D).
All of the experimental asthmatic profiles in Fig. 3 have a positive
IIINO postexercise, resulting in a delay in the appearance of NO (increased V90NO) and decrease in FENO,50. Our model indicates this scenario is consistent with ventilation heterogeneity in either the proximal or peripheral airway combined with enhanced NO airway flux in the slower emptying compartment relative to the remaining lung. The enhanced heterogeneity in NO production may be due to the enhanced rate of ventilation during exercise, which would preferentially washout NO stores in well-ventilated airways, resulting in a higher NO flux in the poorly ventilated region. Note that these observations cannot be explained with single-path models that utilize a single airway compartment and a single homogeneous alveolar region.
The multicompartment model represents the simplest generalization of the existing two-compartment model of pulmonary NO exchange (4, 23, 28) that could incorporate ventilation heterogeneity by considering two airway compartments that empty at different rates. This model for asthma is characterized by four independent structural and ventilation parameters (N,
,
, and
1,0), whose values were chosen to generate reasonable values for Sacin and Scond in healthy and asthmatic lungs. The set of values for the structural and ventilation parameters are not unique but do represent values that are physiological. Thus, although a different set of ventilation and structural parameters could have been chosen, the simulations represent a realistic prediction of how ventilation and NO production heterogeneity can impact the exhaled NO profile. Further, the results indicate that incorporating information about ventilation heterogeneity obtained from multiple-breath nitrogen washout into models of NO exchange dynamics may improve the interpretation of exhaled NO profiles. Although beyond the scope of the present study, future studies may describe a more rigorous approach to determine the structural and ventilation parameters for each subject on the basis of nonlinear regression techniques to fit the model MBNW profiles to experimental tracings. A similar approach might be employed to determine unique and subject-specific values for the five NO production parameters.
In conclusion, we have developed the first model of pulmonary NO exchange that incorporates heterogeneity in ventilation and NO production. Model simulations suggest that the combination of ventilation and NO production heterogeneity may significantly affect the magnitude and shape of exhaled NO profiles in patterns that are consistent with experimental observations in mild asthmatic subjects following an exercise challenge. This result confounds the interpretation of the plateau NO concentration. Hence, characterizing NO exchange dynamics with region-specific alveolar NO concentrations and airway flux of NO in the multicompartment model may provide more useful physiological information than either plateau concentration alone, or an airway flux and alveolar concentration from the single-path, two-compartment model.
| GRANTS |
|---|
|
|
|---|
| ACKNOWLEDGMENTS |
|---|
|
|
|---|
| FOOTNOTES |
|---|
The costs of publication of this article were defrayed in part by the payment of page charges. The article must therefore be hereby marked "advertisement" in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.
* V. Suresh and D. A. Shelley contributed equally to this study. ![]()
| REFERENCES |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
L. L. Karlsson, Y. Kerckx, L. E. Gustafsson, T. E. Hemmingsson, and D. Linnarsson Microgravity decreases and hypergravity increases exhaled nitric oxide J Appl Physiol, November 1, 2009; 107(5): 1431 - 1437. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Kerckx and A. Van Muylem Axial distribution heterogeneity of nitric oxide airway production in healthy adults J Appl Physiol, June 1, 2009; 106(6): 1832 - 1839. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Verbanck, Y. Kerckx, D. Schuermans, C. de Bisschop, H. Guenard, R. Naeije, W. Vincken, and A. Van Muylem The effect of posture-induced changes in peripheral nitric oxide uptake on exhaled nitric oxide J Appl Physiol, May 1, 2009; 106(5): 1494 - 1498. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||