Journal of Applied Physiology Millar Instruments
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 104: 1230-1231, 2008. First published November 29, 2007; doi:10.1152/japplphysiol.01226.2007
8750-7587/08 $8.00
This Article
Right arrow Full Text (PDF) Free
Right arrow All Versions of this Article:
104/4/1230    most recent
01226.2007v1
Right arrow Submit a response
Right arrow View responses
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ferguson, N. D.
Right arrow Articles by Slutsky, A. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ferguson, N. D.
Right arrow Articles by Slutsky, A. S.

POINT-COUNTERPOINT

Point:Counterpoint: High-frequency ventilation is/is not the optimal physiological approach to ventilate ARDS patients

Niall D. Ferguson1,2 and Arthur S. Slutsky1,3

1Interdepartmental Division of Critical Care Medicine and
the Department of Medicine, Division of Respirology
2University Health Network and the
3Keenan Research Center at the Li Ka Shing Knowledge
Institute of St. Michael's Hospital
University of Toronto, Toronto, Canada
e-mail: slutskya{at}smh.toronto.on.ca

POINT: HIGH-FREQUENCY VENTILATION IS THE OPTIMAL PHYSIOLOGICAL APPROACH TO VENTILATE ARDS PATIENTS

Before we can agree (or disagree) on whether high-frequency ventilation is the optimal physiological approach for ventilating patients with acute respiratory distress syndrome (ARDS), we must first define exactly what we mean by an optimal physiological approach. In this regard, we are not talking about restoring a "normal" physiological pattern of breathing nor even necessarily achieving "normal" blood gases. The goals of mechanical ventilation in ARDS have changed markedly over the last 10–15 years; we now define an optimal physiological approach as that which preserves "acceptable" gas exchange while simultaneously minimizing further lung injury caused by the ventilator, termed ventilator-induced lung injury (VILI; Ref. 4). This focus on VILI avoidance is justified by a wealth of preclinical data (briefly discussed below), along with several clinical trials demonstrating decreased mortality with lung-protective ventilation strategies (24, 28).

VILI occurs through various mechanisms, including oxygen toxicity, volutrauma, atelectrauma, and biotrauma (4, 27). Relatively early research documented oxygen toxicity—the deleterious effects of high levels of oxygen on lung tissue (14). Volutrauma refers to lung injury arising from pulmonary overdistension (5). ARDS is a heterogeneous disease; the least damaged (most compliant) regions of lung receive a disproportionate fraction of the inspired volume and are at particularly high risk of volutrauma. There is surfactant deficiency and alveolar instability resulting in repetitive alveolar collapse (atelectasis) and reopening, which generates shear forces that accentuate lung injury: so-called atelectrauma (20). Limiting alveolar collapse (by adequate positive end-expiratory pressure [PEEP]) can mitigate atelectrauma (13, 23, 25, 27, 30). These three mechanisms of ventilator-induced lung injury can all contribute to biotrauma with release of inflammatory mediators [e.g., interleukins, tumor necrosis factor (TNF)-{alpha}, ...; Refs. 4, 26]. These mediators can translocate into the circulation (15, 2527), potentially contributing to multi-organ dysfunction, the major cause of ARDS mortality. As demonstrated below, high-frequency oscillation (HFO) addresses all of these major mechanisms of injury while providing adequate gas exchange; hence, from a physiological perspective, it is the ideal way to ventilate patients with ARDS.

HFO is a subtype of high-frequency ventilation that provides pressure oscillations around a relatively constant mean airway pressure, delivering very small tidal volumes (VT) at high respiratory rates (frequencies) of 3–15 Hz. The key to the lung protective potential of HFO are these very small VT. Not only will they directly limit tidal overdistension and volutrauma, but equally importantly they facilitate the safe use of higher mean airway pressures to mitigate atelectrauma. With minimal tidal excursions, the mean airway pressure on HFO can be thought of as being similar to positive-end expiratory pressure (PEEP) on conventional ventilation. CO2 removal is achieved through a number of mechanisms including bulk convection, convective streaming, pendelluft, cardiogenic mixing, and diffusion (21). Because cyclic alveolar stretch is minimal, volutrauma can be avoided even when the mean airway pressure is set to higher levels than can be reasonably set with PEEP on conventional ventilation. Indeed, to the extent that these higher mean airway pressures are able to recruit previously atelectatic lung, the potential for volutrauma may be further decreased by increasing the size of the "baby lung," (7) and the potential for oxygen toxicity may be reduced as lower FIO2s are required.

This lung-protective potential of HFO has been examined in numerous animal studies. In addition to older studies that demonstrated benefits of HFO versus traditional ventilation (i.e., with higher VT than currently used), the majority of more recent studies that have compared HFO with a lung-protective conventional strategy have continued to demonstrate the superiority of HFO on physiological (e.g., oxygenation, compliance), inflammatory (e.g., TNF-{alpha}, IL-6, neutrophil counts in broncho-alveolar lavage), and pathological evidence of lung injury (11, 12, 17, 19, 29). Thus there are strong animal data supporting the concept that HFO is better than conventional lung-protective ventilation.

These physiological advantages of HFO would be meaningless if HFO were not effective in humans. Clinically, HFO was first introduced in the neonatal ICU; whereas there are important differences in characteristics, pathology, and management between neonates with respiratory distress syndrome and adults with ARDS, some important inferences can still be drawn from this population. In general, randomized controlled trials (RCTs) that have employed a lung recruitment strategy in the HFO arm have shown better oxygenation and lung mechanics in the HFO group, with some showing significant improvement in outcomes (e.g., chronic lung disease; Ref. 10). Even with all the advances made in the care of neonatal respiratory distress in the last two decades, a cumulative meta-analysis continues to demonstrate benefit with HFO (1).

Adult HFO has been commercially available for only 10 years, so this body of literature is understandably smaller. The largest of two published RCTs comparing HFO with conventional ventilation showed an impressive trend toward decreased mortality with HFO (absolute risk difference 16%; R-R 0.72; 95% confidence interval 0.50–1.04; Ref. 3). The smaller RCT did not demonstrate a mortality trend in either direction, but these results are confounded by an almost 20% crossover rate and by large baseline differences favoring the control group (2). We readily admit that data from these trials are not definitive. There are methodological issues: small sample sizes and the use of now dated, potentially injurious conventional ventilation strategies in the control arms; they do, however, provide supporting data that are consistent with our physiological framework supporting HFO. It is important to point out that the purpose of this debate is not to demonstrate that HFO is better clinically, but rather that it represents the "optimal physiological" ventilatory approach that is currently available. Of course, the most important issue for patients is clinical outcomes, but unfortunately there are insufficient data in the literature to adequately address this point (if these existed, there would be no debate).

We stated earlier that the very small VTs on HFO are the cornerstone of this physiological framework. It is true, however, that VT is not routinely measured with currently available oscillators; as such, one might argue that the VTs on HFO are really not as small as we suggest. VT during HFO is inversely related to frequency (because of decreasing inspiratory time with increasing frequency; Ref. 22); however in adults, respiratory frequencies are often lower than those used in neonates (3–6 vs. 12–15 Hz). Work from our worthy opponent's laboratory questions whether delivered VTs are in fact small; Sedeek and colleagues (198) measured VTs of up to 4 ml/kg at high-pressure amplitudes and low frequencies in an ovine model. Unfortunately, for technical reasons, these VT measurements may be overestimated (8), but importantly they have prompted further investigation. HFO in adults can in fact be set to deliver very small VTs in adults, particularly when the strategy focuses on using the highest frequency possible (6). Recent work shows that HFO VTs in adult patients [measured using a hot-wire anemometer) are reassuringly small (1.1–2.5 ml/kg)(9)]. This is in accord with early data demonstrating that normocapnic levels of PaCO2 can be achieved with HFO using VTs averaging 1.5 ml/kg (16).

In summary, by allowing greater end-expiratory volume while simultaneously minimizing cyclic end-inspiratory stretch, HFO is theoretically better suited than any conventional ventilation strategy for avoiding ventilator-induced lung injury, an important contributor to the high mortality observed in ARDS patients. The strong physiological rationale, experimental data from animal studies, and encouraging clinical findings all point toward HFO being an ideal mode for lung-protection in patients with severe ARDS. All that awaits is clinical confirmation by a definitive RCT—an issue that we are currently in the process of addressing.

REFERENCES

  1. Bollen CW, Uiterwaal CS, van Vught AJ. Cumulative metaanalysis of high-frequency versus conventional ventilation in premature neonates. Am J Respir Crit Care Med 168: 1150–1155, 2003.[Free Full Text]
  2. Bollen CW, van Well GT, Sherry T, Beale RJ, Shah S, Findlay GP, Monchi M, Chiche JD, Weiler N, Uiterwaal CS, van Vught AJ. High frequency oscillatory ventilation compared with conventional mechanical ventilation in adult respiratory distress syndrome: a randomized controlled trial. Crit Care 9: 430–439, 2005.[CrossRef]
  3. Derdak S, Mehta S, Stewart TE, Smith T, Rogers M, Buchman TG, Carlin B, Lowson S, Granton J, Multicenter Oscillatory Ventilation For Acute Respiratory Distress Syndrome Trial (MOAT) Study Investigators. High-frequency oscillatory ventilation for acute respiratory distress syndrome in adults: a randomized, controlled trial [see comment]. Am J Resp Crit Care Med 166: 801–808, 2002.[Abstract/Free Full Text]
  4. Dos Santos CC, Slutsky AS. The contribution of biophysical lung injury to the development of biotrauma. Annu Rev Physiol 68: 585–618, 2006.[CrossRef][Web of Science][Medline]
  5. Dreyfuss D, Saumon G. Ventilator-induced lung injury: lessons from experimental studies. Am J Resp Crit Care Med 157: 294–323, 1998.[Web of Science][Medline]
  6. Fessler HE, Derdak S, Ferguson ND, Hager DN, Kacmarek RM, Thompson BT, Brower RG. A protocol for high-frequency oscillatory ventilation in adults: results from a roundtable discussion. Crit Care Med 35: 1649–1654, 2007.[CrossRef][Web of Science][Medline]
  7. Gattinoni L, Pesenti A. The concept of "baby lung." Intensive Care Med 31: 776–784, 2005.[CrossRef][Web of Science][Medline]
  8. Gerstmann D. Major benefit of small tidal volumes during high-frequency ventilation. Crit Care Med 31: 328–329, 2003.[CrossRef][Web of Science][Medline]
  9. Hager DN, Fessler HE, Kaczka DW, Shanholtz CB, Fuld MK, Simon BA, Brower RG. Tidal volume delivery during high-frequency oscillatory ventilation in adults with acute respiratory distress syndrome. Crit Care Med 35: 1522–1529, 2007.[CrossRef][Web of Science][Medline]
  10. Henderson-Smart DJ. Elective high frequency oscillatory ventilation versus conventional ventilation for acute pulmonary dysfunction in preterm infants. Cochrane Database Syst Rev 2: 2006, 2006.
  11. Imai Y, Nakagawa S, Ito Y, Kawano T, Slutsky AS, Miyasaka K. Comparison of lung protection strategies using conventional and high-frequency oscillatory ventilation. J Appl Physiol 91: 1836–1844, 2001.[Abstract/Free Full Text]
  12. Muellenbach RM, Kredel M, Said HM, Klosterhalfen B, Zollhoefer B, Wunder C, Redel A, Schmidt M, Roewer N, Brederlau J. High-frequency oscillatory ventilation reduces lung inflammation: a large-animal 24-hour model of respiratory distress. Intensive Care Med 33: 1423–1433, 2007.[CrossRef][Web of Science][Medline]
  13. Muscedere JG, Mullen JB, Gan K, Slutsky AS. Tidal ventilation at low airway pressures can augment lung injury. Am J Resp Crit Care Med 149: 1327–1334, 1994.[Abstract]
  14. Nash G, Blennerhassett JB, Pontoppidan H. Pulmonary lesions associated with oxygen therapy and artificial ventilation. N Engl J Med 276: 368–374, 1967.[Web of Science][Medline]
  15. Ranieri VM, Suter PM, Tortorella C, De Tullio R, Dayer JM, Brienza A, Bruno F, Slutsky AS. Effect of mechanical ventilation on inflammatory mediators in patients with acute respiratory distress syndrome: a randomized controlled trial. JAMA 282: 54–61, 1999.[Abstract/Free Full Text]
  16. Rossing TH, Slutsky AS, Lehr JL, Drinker PA, Kamm R, Drazen JM. Tidal volume and frequency dependence of carbon dioxide elimination by high-frequency ventilation. N Engl J Med 305: 1375–1379, 1981.[Abstract]
  17. Rotta AT, Gunnarsson B, Fuhrman BP, Hernan LJ, Steinhorn DM. Comparison of lung protective ventilation strategies in a rabbit model of acute lung injury. Crit Care Med 29: 2176–2184, 2001.[CrossRef][Web of Science][Medline]
  18. Sedeek KA, Takeuchi M, Suchodolski K, Kacmarek RM. Determinants of tidal volume during high-frequency oscillation. Crit Care Med 31: 227–231, 2003.[CrossRef][Web of Science][Medline]
  19. Sedeek KA, Takeuchi M, Suchodolski K, Vargas SO, Shimaoka M, Schnitzer JJ, Kacmarek RM. Open-lung protective ventilation with pressure control ventilation, high-frequency oscillation, and intratracheal pulmonary ventilation results in similar gas exchange, hemodynamics, and lung mechanics. Anesthesiology 99: 1102–1111, 2003.[CrossRef][Web of Science][Medline]
  20. Slutsky AS. Lung injury caused by mechanical ventilation. Chest 116: 9S–15S, 1999.[CrossRef]
  21. Slutsky AS, Drazen JM. Ventilation with small tidal volumes. N Engl J Med 347: 630–631, 2002.[Free Full Text]
  22. Slutsky AS, Kamm RD, Rossing TH, Loring SH, Lehr J, Shapiro AH, Ingram RHJ, Drazen JM. Effects of frequency, tidal volume, and lung volume on CO2 elimination in dogs by high frequency (2–30 Hz), low tidal volume ventilation. J Clin Invest 68: 1475–1484, 1981.[Web of Science][Medline]
  23. Steinberg JM, Schiller HJ, Halter JM, Gatto LA, Lee HM, Pavone LA, Nieman GF. Alveolar instability causes early ventilator-induced lung injury independent of neutrophils. Am J Resp Crit Care Med 169: 57–63, 2004.[Abstract/Free Full Text]
  24. The Acute Respiratory Distress Syndrome Network. Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. N Engl J Med 342: 1301–1308, 2000.[Abstract/Free Full Text]
  25. Tremblay L, Valenza F, Ribeiro SP, Li J, Slutsky AS. Injurious ventilatory strategies increase cytokines and c-fos m-RNA expression in an isolated rat lung model. J Clin Invest 99: 944–952, 1997.[Web of Science][Medline]
  26. Tremblay LN, Slutsky AS. Ventilation-induced lung injury: from barotrauma to biotrauma. Proc Assoc Am Phys 110: 482–488, 1998.[Web of Science][Medline]
  27. Tremblay LN, Slutsky AS. Ventilator-induced lung injury: from the bench to the bedside. Intensive Care Med 32: 24–33, 2006.[CrossRef][Web of Science][Medline]
  28. Villar J, Kacmarek RM, Perez-Mendez L, Aguirre-Jaime A. A high positive end-expiratory pressure, low tidal volume ventilatory strategy improves outcome in persistent acute respiratory distress syndrome: a randomized, controlled trial. Crit Care Med 34: 1311–1318, 2006.[CrossRef][Web of Science][Medline]
  29. von der Hardt K, Kandler MA, Fink L, Schoof E, Dotsch J, Brandenstein O, Bohle RM, Rascher W. High frequency oscillatory ventilation suppresses inflammatory response in lung tissue and microdissected alveolar macrophages in surfactant depleted piglets. Pediatr Res 55: 339–346, 2004.[CrossRef][Web of Science][Medline]
  30. Webb HH, Tierney DF. Experimental pulmonary edema due to intermittent positive pressure ventilation with high inflation pressures. Protection by positive end-expiratory pressure. Am Rev Resp Dis 110: 556–565, 1974.[Web of Science][Medline]



This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
R. M. Muellenbach, C. Wunder, J. Brederlau, J. Villar, A. T. Rotta, S. Maruvada, G. Vento, M. Tana, C. Tirone, V. Vendettuoli, et al.
High-frequency ventilation is/is not the optimal physiological approach to ventilate ARDS patients.
J Appl Physiol, April 1, 2008; 104(4): 1236 - 1237.
[Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
N. Ferguson and A. Slutsky
Last Word on Point:Counterpoint: High-frequency ventilation is/is not the optimal physiological approach to ventilate ARDS patients
J Appl Physiol, April 1, 2008; 104(4): 1240 - 1240.
[Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
R. M. Kacmarek
Last Word on Point:Counterpoint: High-frequency ventilation is/is not the optimal physiological approach to ventilate ARDS patients
J Appl Physiol, April 1, 2008; 104(4): 1241 - 1241.
[Full Text] [PDF]


This Article
Right arrow Full Text (PDF) Free
Right arrow All Versions of this Article:
104/4/1230    most recent
01226.2007v1
Right arrow Submit a response
Right arrow View responses
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ferguson, N. D.
Right arrow Articles by Slutsky, A. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ferguson, N. D.
Right arrow Articles by Slutsky, A. S.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online
Copyright © 2008 by the American Physiological Society.