Journal of Applied Physiology Information on EB 2010
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 102: 787-793, 2007. First published October 12, 2006; doi:10.1152/japplphysiol.00596.2006
8750-7587/07 $8.00
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF) Free
Right arrow All Versions of this Article:
102/2/787    most recent
00596.2006v1
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schwenke, D. O.
Right arrow Articles by Shirai, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schwenke, D. O.
Right arrow Articles by Shirai, M.

INNOVATIVE METHODOLOGY

Imaging of the pulmonary circulation in the closed-chest rat using synchrotron radiation microangiography

Daryl O. Schwenke,1 James T. Pearson,2 Keiji Umetani,4 Kenji Kangawa,1 and Mikiyasu Shirai3

1Department of Biochemistry, National Cardiovascular Center Research Institute, Suita, Osaka, Japan; 2Department of Physiology, and Monash Centre for Synchrotron Science, Monash University, Melbourne, Australia; 3Faculty of Health Sciences, Hiroshima International University, Hiroshima; and 4Japan Synchrotron Radiation Research Institute, Hyogo, Japan

Submitted 29 May 2006 ; accepted in final form 7 October 2006


    ABSTRACT
 TOP
 ABSTRACT
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 GRANTS
 ACKNOWLEDGMENTS
 REFERENCES
 
Structural changes of the pulmonary circulation during the pathogenesis of pulmonary arterial hypertension remain to be fully elucidated. Although angiography has been used for visualizing the pulmonary circulation, conventional angiography systems have considerable limitations for visualizing small microvessels (diameters < 200 µm), particularly within a closed-chest animal model. In this study we assess the effectiveness of monochromatic synchrotron radiation (SR) for microangiography of the pulmonary circulation in the intact-chest rat. Male adult Sprague-Dawley rats were anesthetized, and a catheter was positioned within the right ventricle, for administering iodinated contrast agent (Iomeron 350). Subsequently, microangiography of pulmonary arterial branches within the left lung was performed using monochromatic SR. Additionally, we assessed dynamic changes in vessel diameter during acute hypoxic (10% and 8% O2 for 4 min each) pulmonary vasoconstriction (HPV). Using SR we were able to visualize pulmonary microvessels with a diameter of <100 µm (the 4th generation of branching from the left axial artery). Acute hypoxia caused a significant decrease in the diameter of all vessels less than 500 µm. The greatest degree of pulmonary vasoconstriction was observed in vessels with a diameter between 200 and 300 µm. These results demonstrate the effectiveness of SR for visualizing pulmonary vessels in a closed-chest rat model and for assessing dynamic changes associated with HPV. More importantly, these observations implicate SR as an effective tool in future research for assessing gross structural changes associated with the pathogenesis of pulmonary arterial hypertension.

pulmonary microvessels; hypoxia; intact chest


STRUCTURAL AND FUNCTIONAL changes of the pulmonary circulation, particularly during the pathogenesis of pulmonary arterial hypertension (PAH), remain to be fully elucidated. Specifically, the small peripheral pulmonary arteries (<500 µm) are believed to be most susceptible to structural changes during, for example, chronic exposure to hypoxia (1, 6, 7, 15, 19, 32).

To date, most small-animal studies that have described the anatomic geometry of the pulmonary circulation have been limited to the use of in vitro or ex vivo preparations. While such data have aided our understanding concerning the pulmonary microcirculation, such invasive procedures ultimately disrupt the natural physiological milieu of the lung. Ideally, a technique of visualizing the pulmonary circulation within a closed-chest model, i.e., under intact neurohumoral regulation, is required to fully understand the structural and functional properties of the microcirculation in the normal lung as well as understand the dynamic changes that occur in pathological conditions (e.g., PAH).

Angiography has been used for visualizing the pulmonary circulation of laboratory animals. However, conventional angiography systems have considerable limitations in providing images of small blood vessels with diameters of <200 µm in vivo (30, 33). Shirai et al. (25) designed a unique X-ray TV system for directly visualizing pulmonary vessels in the cat with diameters 100–500 µm, although such measurements were only possible in open-chest animal models (24, 27). In the last decade, technological advances in microangiography have utilized monochromatic synchrotron radiation (SR) as a powerful X-ray source and, when coupled with a high-resolution and high-speed imaging system, provide the ability to study microvessels of various animal organs ex vivo and in vivo (18). Tanaka et al. (28) were able to visualize coronary vessels (>50 µm) in the exposed dog heart. Moreover, Yamashita et al. (33) used SR to study mouse coronary arteries in beating hearts in vivo, and Tokiya et al. (30) were able to observe the microvasculature of tumors (in vitro) with vessel diameters as small as 20–30 µm.

This study demonstrates for the first time the ability to clearly visualize pulmonary microvessels in an anesthetized closed-chest rat model using SR. Furthermore, we demonstrate the effectiveness and reliability of SR angiography to detect dynamic changes in vessel diameter during acute hypoxia [i.e., acute hypoxic pulmonary vasoconstriction (HPV)].


    MATERIALS AND METHODS
 TOP
 ABSTRACT
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 GRANTS
 ACKNOWLEDGMENTS
 REFERENCES
 
Animals.   Experiments were conducted on seven male Sprague-Dawley rats (8 wk old; body wt ~250–350 g). All rats were on a 12:12-h light-dark cycle at 25 ± 1°C and were provided with food and water ad libitum. All experiments were approved by the local Animal Ethics Committee and conducted in accordance with the guidelines of the Physiological Society of Japan.

Anesthesia and surgical preparation.   Rats were anesthetized with pentobarbital sodium (60 mg/kg ip). Supplementary doses of anesthetic were periodically administered (~15 mg·kg–1·h–1 ip). Throughout the surgery, body temperature was maintained at 37°C using a rectal thermistor coupled with a thermostatically controlled heating pad.

The trachea was cannulated and the lungs ventilated with a rodent ventilator (SN-480–7, Shinano, Tokyo, Japan). The inspirate gas was enriched with O2 (~50% O2), and the ventilator settings were adjusted [tidal volume ~3.5 ml; frequency ~70 breaths/min; these settings were previously shown to maintain arterial PCO2 normocapnic]. A 20-gauge BD Angiocath catheter (Becton Dickinson), with the tip at a 30° angle, was inserted into the jugular vein and advanced into the right ventricle for administering contrast agent as well as intermittently measuring right ventricular pressure (RVP).

The rat was securely fastened to a clear Perspex surgical plate, which had a single window directly beneath the thorax area. The surgical plate was then fixed in a vertical position in front of the beam pathway so that the synchrotron beam would pass perpendicular to the sagittal plane from anterior to posterior through the rat thorax, with the aid of the window in the Perspex plate, and ultimately to a SATICON X-ray camera described below (Fig. 1).


Figure 1
View larger version (12K):
[in this window]
[in a new window]

 
Fig. 1. Simplified schematic diagram showing the experimental setup for pulmonary microangiography in a closed-chest rat model using monochromatic synchrotron radiation at the SPring-8 facilities in Hyogo, Japan.

 
Microangiographic system.   The pulmonary circulation was visualized using SR microangiography at the SPring-8 BL28B2 beam line facility, Hyogo, Japan. The microangiographic system has previously been described in detail (11, 30).

SR has a broad and continuous spectrum from the infrared to the X-ray regions. A single-crystal monochromator selects a single energy of SR, and the X-rays of a very narrow energy bandwidth (an energy bandwidth of 0.02–0.03 keV) are used for imaging. This SR system comprises a monochromatic 33.2-keV X-ray source, just above the iodine K-edge energy for maximal contrast. The monochromatic X-ray beam from the synchrotron source is highly collimated. Furthermore, the small size of the X-ray source and the very long source-to-object distance ensures that image size distortion is avoided (i.e., measurement of vessel diameter does not change at different depths within the lung). The distance between the X-ray source and object was 4,610 cm, and the distance between the object and detector was ~20 cm. Therefore, the magnification scale is 1.004; i.e., no significant magnification can be assumed.

X-rays transmitted through a subject are detected by an X-ray detector (Hitachi Denshi Techno-System, Tokyo, Japan) incorporating a SATICON X-ray pickup tube (Hamamatsu Photonics, Shizuoka, Japan). X-rays absorbed in the photoconductive layer of the tube are directly converted into electron-hole pairs. Charge carriers generated by X-rays are transported across the photoconductive layer by an electric field. A charge-density pattern is then formed on the photoconductive layer surface. The electrostatic image on the surface is read out by a scanning beam of low-velocity electrons to produce a video signal.

The biomedical imaging SATICON X-ray camera has a resolution of 1,050 scanning lines and can record images at a maximum speed of 30 frames/s for up to 30 s. The shutter open time used in this study was 2.6–3.0 ms/frame. The detector features a 9.5-µm equivalent pixel size projected onto the input area and an input field size of 9.5 x 9.5 mm. High-resolution images were stored in a digital frame memory system with 1,024 x 1,024 pixel format and 10-bit resolution.

Experimental protocol.   The rat was positioned in front of the beam line so that the upper segment of the left lobe was positioned in front of the SATICON X-ray camera in alignment with the 9.5 x 9.5 mm imaging field (i.e., between the 2nd and 3rd rib; see Fig. 2). Subsequently, baseline heart rate (HR) and RVP data were collected. Immediately before vessel imaging, the three-way stopcock on the right ventricle catheter was opened to a clinical autoinjector (Nemoto Kyorindo, Tokyo, Japan), which was used to inject a single bolus of contrast agent (Iomeron 350; Eisai, Tokyo, Japan) at high speed (0.4 ml at 0.4 ml/s) so as to provide a concentrated dose of agent within the pulmonary vasculature during the first second of the 2-s period of imaging, thus ensuring optimal visualization of the pulmonary microvessels using angiography. For each 2-s period of scanning, 100 frames were recorded. Rats were given at least 10 min to recover from each injection of contrast agent. Regular inspection between contrast injections confirmed that the pulmonary vasculature was clear of agent within this period of time. However, it is possible that not all of the contrast agent had been expelled by the rat, since some residual agent has been observed in the kidney of rats 10 min after administration (G. A. Eppel, M. Shirai, K. Umetani, and J. T. Pearson, unpublished observations).


Figure 2
View larger version (54K):
[in this window]
[in a new window]

 
Fig. 2. Schematic drawing of the arterial circulation of the left lung in a rat. The square box represents the position of the 9.5 x 9.5-mm imaging window used for microangiography of the pulmonary microvessels.

 
X-ray flux at the position of the sample (subject) was ~1 x 1010 photons·mm–2·s–1 at an energy of 33.2 keV. Therefore, the dose of radiation is 1.4 mGy per one frame at an exposure time of 2 ms, resulting in a total dose of 140 mGy in one scan of 100 consecutive frames. The dose value is ~2 times higher than that in clinical coronary angiographic imaging. However, it is possible to reduce the number of images per scan by half to be acceptable for repeated scans in the future.

Following baseline imaging, rats were randomly exposed to two levels of acute hypoxia (8% O2 and 10% O2 in N2), each for 4 min. There was a period of 10–15 min between each hypoxic test. During acute hypoxia, HR and RVP data were continuously recorded until the third minute, after which recording of RVP was stopped, and the catheter was switched from the pressure transducer to the clinical injector for imaging. Lung microangiography was performed on the hypoxic lung after the fourth minute of each level of hypoxia.

Data acquisition and analysis.   The RVP signal was detected using a Deltran pressure transducer (Utah Medical Products), amplified, and then sampled at 500 Hz with a DAQ pad data-recording system (National Instruments 6052E, Austin, TX) using DAQ-Universal 2004 custom software (courtesy of Geoff Head, Baker Heart Institute). HR was derived from the right ventricular systolic peaks.

During the 2-s period of image collection, pulmonary vessels pulsated, and vessel caliber fluctuated, due to the mechanical forces associated with systole and diastole. Consequently, only individual frames recorded at, or near, end systole were used for assessing and comparing pulmonary vessel diameter between baseline and hypoxic conditions. It was possible to identify the image at, or near, end systole by splitting the RVP signal and relaying one of the signals to an oscilloscope (the other signal was directed to the DAQ pad). A separate Hamamatsu charge-coupled device (CCD) camera (Hamamatsu Photonics) was synchronized with the angiography SATICON X-ray pickup camera so that for every angiogram image recorded, a corresponding image of the oscilloscope was also captured as a separate tiff file. At a heart rate between 350 and 400 beats/min and at 30 frames/s there were 5.8–6.7 beats/s, equivalent to approximately 5–6 frames within each cardiac cycle. Therefore it was possible to select an image at, or very close to, end systole.

One frame per scan (one scan = 100 frames) was selected for image enhancement and analysis. Where possible, two to four vessels of each branching generation (2nd to 4th generation) were analyzed to ensure that a wide variety of vessel sizes was selected for measurement from each imaging scan. A total of 80 vessels was measured from seven rats, during normoxia and then again for each level of hypoxia. Six clearly identifiable vessels had a diameter <100 µm; 28 vessels had a diameter between 100 and 200 µm; 22 vessels had a diameter between 200 and 300 µm; 12 vessels had a diameter between 300 and 500 µm; and 12 vessels had a diameter >500 µm.

Image analysis.   The computer-imaging program Image Pro-plus (version 4.1, Media Cybernetics) was used to enhance contrast and the clarity of angiogram images. To enhance images, a temporal subtraction operation was performed for flat-field correction using summation results of 10 consecutive frames acquired before contrast-agent injection. The summation image taken before injection was subtracted from a single raw image taken after injection to eliminate the superimposed background structure (Fig. 3). The pixel intensities of the raw image were first multiplied by a factor of 10. When the contrast between the foreground (vessels) and background is increased by averaging the background, boundary segmentation best clarifies the objects of interest.


Figure 3
View larger version (43K):
[in this window]
[in a new window]

 
Fig. 3. Illustration of the computer-aided process for temporal subtraction for flat-field correction. The summation of 10 images taken before injection (summated background) was subtracted from a single raw image taken after injection (raw image). The resultant image (final image) has the superimposed background structure eliminated. Note the 100-µm-thick wire has also been eliminated in the subtracted image.

 
Image Pro-plus was also used to evaluate the vessel internal diameter. A 100-µm-thick tungsten filament, which had been placed directly across the corner of the detector's window, appeared in all recorded images and was subsequently used as a reference for calculating vessel diameter (µm). The line-profile function of Image Pro-Plus was used to measure changes in pixel intensity (brightness) along manually drawn segments perpendicular to the vessel, which span 10–40 pixels on either side of the vessel (see Fig. 4C). The first edge of the vessel was determined as the pixel at which intensity decreased below that of the preceding 10–40 pixels (depending on space between vessels). The opposite criterion was applied to ascertain the distal edge of the vessel. This boundary segmentation procedure was performed at two different points along the length of the vessel, and the average of the two values was used for data collation. To assess reproducibility, the procedure for measuring vessel width was repeated by a second observer.


Figure 4
View larger version (84K):
[in this window]
[in a new window]

 
Fig. 4. Typical microangiogram images (after temporal subtraction) showing the branching pattern of small pulmonary arteries (1st to 4th generation) during normoxia (i.e., baseline) (A) and in response to acute hypoxia (10% O2) (B). The arrows in B point to branches of the pulmonary vessels that have constricted in response to hypoxia. Line profiles (depicting pixel intensity) of the transected vessel from A [normoxia (N)] and B [acute hypoxia (H)], illustrating the measurement of vessel width, are presented in C. In this particular example, hypoxia caused an ~25% decrease in vessel caliber.

 
All numerical data are presented as means ± SE. One-way ANOVA (factorial) was used to test for differences in vessel diameter during normoxia compared with acute hypoxia. A P value ≤ 0.05 was predetermined as the level of significance for all statistical analysis.


    RESULTS
 TOP
 ABSTRACT
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 GRANTS
 ACKNOWLEDGMENTS
 REFERENCES
 
Baseline.   Using SR, we were able to clearly visualize pulmonary microvessels in the left lung of an intact-chest rat. Figure 4A shows the branching pattern of the pulmonary artery from the main axial artery of the left lobe to the fourth generation of branching (within the 9.5 x 9.5-mm imaging window). Vessel caliber tended to decrease according to each generation of branching, as well as the distance away from the main axial artery toward the periphery. In general, the axial artery was ~1,200 µm at the point of branching in Fig. 4A. Thereafter, the first primary branch was ~600–800 µm, and the second branch was ~400–600 µm. By the fourth generation of branching, vessel caliber was sometimes <100 µm in diameter (the 100-µm-diameter tungsten wire was the reference). The smallest vessels that could be clearly measured were ~80 µm. These vessels, however, were not visible (or the vessel edges were too opaque to be accurately detected by segmentation) during acute exposure to hypoxia and so were excluded from analyses for the acute hypoxic response (see below).

Responses to acute hypoxia.   Rats were exposed to 10% and 8% O2, each for 4 min with time to recover in between each hypoxic test. The changes in HR and systolic RVP in response to acute hypoxia are presented in Table 1. Hypoxia did not alter HR, but it did significantly increase systolic RVP (40–50% increase). Since systolic RVP is a reflection of systolic pulmonary arterial pressure (PAP), the observed increase in systolic RVP indicates that HPV was likely to have occurred. This assumption was confirmed by microangiography.


View this table:
[in this window]
[in a new window]

 
Table 1. Changes in HR and systolic RVP in response to two levels of acute hypoxia (10% and 8% O2) in anesthetized rats

 
Acute hypoxia caused a significant decrease in the internal diameter of all vessels <500 µm (Figs. 4 and 5). The magnitude of constriction tended to increase as vessel caliber decreased, except for those vessels with a diameter of 100–200 µm (Fig. 5). The greatest degree of pulmonary vasoconstriction was observed in vessels with a diameter between 200 and 300 µm. These vessels were generally of the third to fourth generation of branching. In addition, there was no significant difference in the magnitude of hypoxic pulmonary vasoconstriction for 10% O2 and 8% O2 for all vessel sizes.


Figure 5
View larger version (11K):
[in this window]
[in a new window]

 
Fig. 5. The relationship between vessel size and the magnitude of pulmonary vasoconstriction (% decrease in vessel diameter) in response to 2 levels of acute hypoxia (10% and 8% O2) in a closed-chest rat model (n = 7). *Significant response to acute hypoxia (P < 0.05). There was no significant difference in the magnitude of response between 10% and 8% O2.

 
Evaluation of accuracy of measurement.   To estimate a margin of error for accurately detecting the edge of any given vessel containing pure contrast agent, we assessed the variability in our measurements of the width (in pixels) of the reference wire (known diameter of 100 µm). From one individual image frame, we measured wire width at 40 random points along its length. The mean width of this reference wire was 12.99 pixels (SD ±1.12). This equates to an average pixel size of 7.69 µm (95% confidence interval of 7.496–7.908 µm). Consequently, the 100-µm tungsten wire could accurately be measured to within ~5 µm (range of 97.4–102.7 µm).

Measurement of the reference wire represents ideal X-ray absorption and contrast. In this study, however, the iodine contrast agent was injected into the right ventricle so that the iodine concentration within the pulmonary circulation would have been diluted, which is likely to have attenuated X-ray absorption and potentially the accuracy of measuring vessel width. In an earlier preliminary study phantom vascular images were recorded to assess the relationship between X-ray absorption and iodine concentration (K. Umetani, unpublished observations). Using the same experimental set-up as described in MATERIALS AND METHODS, eight tubes with an internal diameter of 200 µm were filled with various concentrations of iodinated contrast material ranging from pure agent (370 mg/cm3 iodine, Nihon Schering) to distilled water (i.e., 0 mg/cm3). In addition, a 5-mm-thick aluminum mask was overlaid to simulate signal attenuation by the animal body.

The widths of tubes containing an iodine concentration between 370 and 32 mg/cm3 could be accurately measured with a small margin of error; e.g., the width of the tube containing 32 mg/cm3 iodine was measured at 40 points and had a 95% confidence interval of 196.84–203.26 µm. This is a similar margin of error as that obtained for multiple measurements of the tungsten reference wire (described above).

These results show that measurements of 200 µm in diameter can be made precisely for those vessels with an iodine concentration of >32 mg/cm3. Moreover, it seems reasonable to suppose that measurements of ~100 µm in diameter can be made with the required precision for those vessels with an iodine concentration of 64 mg/cm3 or greater.

In our study, therefore, even though the bolus contrast agent was diluted within the right ventricle, the iodine concentration within the pulmonary arteries was likely to have been sufficient to detect well-defined edges for those vessels as small as ~100 µm.

One limitation of this study is that it was not possible to make multiple measurements across vessels ~80–150 µm in diameter because of the short length of these peripheral branches. Nevertheless, on the basis of the boundary segmentation procedure used, intra- and interobserver analyses were highly reproducible for each vessel determination. A total of 40 vessels from various branching generations was assessed by two different observers. Regression analysis indicated that the measurements from both observers were highly correlated (y = –4.829 + 0.997x, r2 = 0.979) and had an average difference of 9 ± 2 µm (for 100- to 200-µm vessels) to 14 ± 7 µm (for 300- to 500-µm vessels).


    DISCUSSION
 TOP
 ABSTRACT
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 GRANTS
 ACKNOWLEDGMENTS
 REFERENCES
 
This study demonstrates, for the first time, the ability to visualize the pulmonary circulation in a closed-chest rat model and the dynamic changes associated with HPV using SR microangiography.

Although significant advances in the treatment of pulmonary disorders have been made in recent decades, the underlying mechanisms governing the pathogenesis of PAH remain to be fully elucidated. Before the underlying mechanisms can be examined, however, meticulous information concerning the normal pulmonary vessels is essential to accurately assess the changes in pulmonary arteries in experimental pulmonary hypertension. Yet, ever since the pioneering work of Reid and colleagues (5, 7, 8, 13, 14, 17), there has been a paucity of studies describing the anatomic and structural features of the normal pulmonary vasculature.

One of the primary characteristics of PAH is vascular remodeling and medial thickening of thin muscular-walled vessels (100–300 µm), as well as the formation of new muscle around nonmuscular or partially muscular vessels (50–150 µm) (8, 13, 14, 20). The irreversible remodeling of the pulmonary vasculature (3, 31) decreases the caliber of the pulmonary vessels and causes a sustained increase in PAP. Additionally, sustained hypoxia, which occurs in numerous pulmonary disorders, can cause adverse structural changes in the pulmonary vascular bed, such as pruning of small vessels, contributing to an increase in vascular resistance (5, 7, 16), although more recent evidence suggests that angiogenesis is also occurring in the chronic hypoxia rat lung (9). Ultimately PAH increases the workload of the heart and is, therefore, closely associated with heart failure and increased mortality.

In this study, we were able to clearly visualize pulmonary vessels, with a diameter as small as 80 µm. Although smaller vessels exist within the pulmonary vascular bed, we were unable to clearly detect the border of these vessels, suggesting that the resolution limit of the pulmonary microvessels in this study was close to 80 µm. Determining the exact spatial resolution limit in vivo is difficult in a vessel because of the possibility of nonuniform constrictions or uneven iodine contrast distribution within the smaller vessels, which would increase the signal-to-noise variability between neighboring pixels of any single image.

To enhance the ability to measure vessel diameter in our study, we performed temporal subtraction whereby the summation of 10 consecutive preinjection frames was subtracted from a single postinjection raw image. Only a single postinjection image could be used for subtraction because a summated image would be blurred because of movement of pulmonary vessels (by heart palpitations) during iodine injection. Studies that use vessels that remain static during iodine injection, however, can summate images after contrast injection, as well as before. The final subtracted image not only eliminates background structures but also eliminates uneven iodine distribution and magnifies the contrast between vessel and background. Indeed, such image enhancement allows visualization of vessels <50 µm, and as small as 20–30 µm, within the microvasculature of tumors (in vitro), exposed heart (28), liver (12), and brain (11, 29) of experimental animals.

In our study, we were limited to measuring vessels with a diameter ≥80 µm in the rat lung. Despite this limitation, the vessels that are most susceptible to pathological disorders have an internal diameter >100 µm, i.e., resistance vessels that are at least partially muscular (8). Therefore, the results of our study demonstrate the suitability of SR microangiography for visualizing the small peripheral pulmonary vessels that are normally susceptible to adverse alterations in various pathological conditions.

An advantage of the superior definition achieved with SR is the ability to visualize the pulmonary microvessels within a natural physiological milieu (i.e., within the intact chest), a technique not previously possible with conventional X-ray systems. Conventional X-ray systems with a small focal spot have previously used an X-ray direct-conversion type VIDICON camera as a two-dimensional high-resolution detector (22, 26). This type of X-ray system, however, has limitations when providing images of blood vessels with a diameter <50 µm (even in vitro) because images cannot be magnified without focal spot blurring. Furthermore, polychromatic light from conventional X-ray systems will scatter differently according to wavelength. In addition, a conventional angiography system incorporating an X-ray image intensifier and a video camera is not intended for detection of small vessels of 200 µm diameter or less because it is designed for large-field digital angiographic imaging based on a 1024 x 1024-pixel format.

In contrast to conventional systems, SR is characterized by high brilliance and extreme collimation (28), allowing enhanced sensitivity to contrast material and superior image quality in terms of spatial and density resolution because divergence and scatter of X-ray photons are eliminated. The collimation is possible because of bending magnets in the synchrotron storage ring that maintain beam trajection and minimize X-ray dispersion. Consequently, this allows vessels at different depths to be measured without magnification artifacts.

One concern expressed about this angiography approach is the unlikelihood that a non-synchrotron source with similar spatial and temporal resolution will be available in the immediate future for conventional bench-top X-ray systems. The SPring-8 facility is currently the largest synchrotron source available, but access to synchrotron sources is available in many regions of the world. Therefore, most research groups will have sufficient access to be able to conduct intensive experiments.

HPV in the rat.   In this study we were also able to assess dynamic changes in vessel caliber during acute hypoxia, i.e., the well-documented HPV phenomenon. We showed that all vessels with a diameter <500 µm constricted in response to hypoxia and that those vessels with a diameter of 200–300 µm showed the greatest magnitude of HPV.

HPV has been reported to preferentially occur in vessels with an internal diameter of ~150–300 µm in cats, and rabbits (10, 26, 27) and up to <600 µm in dogs (2). During hypoxia, as PAP increases, vessels larger than 300–500 µm are likely to be subjected to a higher distending pressure (assuming no change in cardiac output), suggesting that constriction of larger vessels (i.e., >500 µm) may be underestimated by a high distending pressure. However, Shirai et al. (27) demonstrated that, when the increase in PAP during hypoxia is prevented, the magnitude of vasoconstriction tends to be accentuated, albeit slightly, equally for all pulmonary vessel sizes in the cat.

Several studies have used a severe level of hypoxia (i.e., ~8% O2) to elicit significant pulmonary vasoconstriction in the rat, rabbit, and cat (10, 21, 22, 27). In this study, we tested severe hypoxia (8% O2) and moderate hypoxia (10% O2) expecting that the magnitude of pulmonary vasoconstriction may be dependent on the severity of hypoxia. Yet the vascular responses to 10% and 8% O2 were similar (assessed by angiography and right ventricular systolic pressure). Shirai et al. (27) also assessed the response of the pulmonary vasculature of the cat lung to moderate (10% O2) and severe (5% O2) hypoxia using angiography. They reported that the magnitude of vasoconstriction was greater for 10% O2 compared with 5% O2, only if the hypoxia was global (i.e., whole body). If the hypoxic stimulus was restricted to just the lung (i.e., regional hypoxia), the magnitude of vasoconstriction was proportional to the degree of hypoxia (i.e., greatest for 5% O2). Hypoxia is a potent activator of pulmonary sympathetic nerve activity (SNA), especially when the inspired level of O2 is below 8% O2 (23, 27). Shirai et al. (27) were able to subsequently demonstrate that the vasoconstrictor effect of global hypoxia was attenuated by a sympathetic beta-receptor-mediated vasodilator effect. Although cats were used in that study (27), the importance of a beta-receptor-mediated vasodilator effect for modulating HPV has also been demonstrated in the rat (4, 5).

In our study, we exposed rats to global hypoxia. It is reasonable, therefore, to speculate that the response to 8% O2 (severe hypoxia) comprised a strong neural response (i.e., a potent increase in a sympathetic beta-receptor-mediated vasodilatation) that countered the local humoral vasoconstrictive response of hypoxia on the pulmonary vasculature. In contrast, the response to 10% O2 (moderate hypoxia) may have comprised mainly the local vasoconstrictive response of hypoxia (without eliciting a significant increase in SNA).

Limitations of this study.   In the SR imaging system, the smallest-diameter vessel seen for the measurements is primarily determined by the concentration of iodinated contrast material. The iodine concentration depends on the type and dose of the contrast material, the injection technique, and the dilution curve and the vessel site under study. One of the limitations of this study was the inability to inject contrast agent directly into the pulmonary circulation of the left lung. Instead, the contrast agent was injected into the right ventricle. Therefore, not all of the contrast agent was delivered into the left lung, and, furthermore, the contrast agent would have been diluted, at least to some extent, by venous return. However, the rate at which contrast agent was injected (0.4 ml at 0.4 ml/s) is approximately equivalent to cardiac output of an anesthetized rat (~24 ml/min). Therefore, even if the bolus dose were diluted by as much as 1:5 in the right ventricle during ejection (equivalent to an iodine concentration of 70 mg/cm3), the preliminary phantom study indicates that vessel edge detection should be accurate and reproducible for vessels as small as 100–200 µm.

Because of the fact that only one frame could be used for measuring vessel caliber, and that the iodine contrast agent was diluted, it was not possible to find an image frame whereby the pulmonary vessels were completely filled with contrast agent. Consequently, this often resulted in images with less-than-perfect contrast. Nevertheless, as mentioned above, despite this limitation, it was still possible to enhance a single image for the purpose of accurately measuring vessel caliber >80 µm.

In this study we could not view the circulation of the whole lung but rather were restricted to a relatively small field of view (FOV) of 9.5 x 9.5 mm. Before the 1990s, video cameras consisted of a pickup tube to capture images. However, advances in technology have meant that pickup tubes have largely been replaced by a CCD. Some pickup tubes cameras, such as the X-ray SATICON camera used at SPring-8, are still used for special purpose applications in scientific and industrial fields. The pickup tube is a glass cylinder maintained under vacuum; the front end of the tube is a flat plate, the inside of which is coated with a photosensitive material. The FOV limit is imposed by the diameter of the glass cylinder, a standard size of 1 in. The 28B2 experimental beam line at SPring-8 produces an X-ray beam of approximately 150 by 100 µm at the sample. Therefore it is not possible to use a larger detector at this specific beam line without increasing the distance between the source and subject significantly. It is anticipated that an X-ray direct-conversion type solid-state image sensor will be available in the near future for special purpose applications (e.g., scientific). This type of sensor will be able to remove restrictions on the FOV, while retaining temporal and spatial resolution at so-called long beam lines with larger beam dimensions.

In summary, we have demonstrated the effectiveness of SR for visualizing pulmonary vessels in a closed-chest rat model and for assessing dynamic changes associated with HPV. Despite some limitations, the observations from this study unlock a wide range of possibilities for using SR in pulmonary microangiography. Of particular importance is the application of SR in future studies for assessing gross structural changes in pulmonary vessel density, and changes in microvessel diameter, associated with the pathogenesis of PAH.


    GRANTS
 TOP
 ABSTRACT
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 GRANTS
 ACKNOWLEDGMENTS
 REFERENCES
 
This study was supported in part by the Program for Promotion of Fundamental Studies in Health Sciences of the National Institute of Biomedical Innovation (NIBIO) and also in part by a Grant-in-Aid for Scientific Research (no. 16659210). We acknowledge financial support from the Access to Major Research Facilities Programme, which is a component of the International Science Linkages Programme (Australian Government).


    ACKNOWLEDGMENTS
 TOP
 ABSTRACT
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 GRANTS
 ACKNOWLEDGMENTS
 REFERENCES
 
The synchrotron radiation experiments were performed at the BL28B2 in the SPring-8 with the approval of the Japan Synchrotron Radiation Research Institute (Proposal No. 2004BO464-NL2-NP).


    FOOTNOTES
 

Address for reprint requests and other correspondence: D. O. Schwenke, Dept. of Physiology, School of Medical Sciences, University of Olago, Dunedin, New Zealand

The costs of publication of this article were defrayed in part by the payment of page charges. The article must therefore be hereby marked "advertisement" in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.


    REFERENCES
 TOP
 ABSTRACT
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 GRANTS
 ACKNOWLEDGMENTS
 REFERENCES
 

  1. Abraham AS, Kay JM, Cole RB, Pincock AC. Hemodynamic and pathological study of the effect of chronic hypoxia and subsequent recovery of the heart and pulmonary vasculature of the rat. Cardiovasc Res 5: 95–71, 1971.[Abstract/Free Full Text]
  2. Al-Tinawi A, Krenz GS, Rickaby DA, Linehan JH, Dawson CA. Influence of hypoxia and serotonin on small pulmonary vessels. J Appl Physiol 76: 56–64, 1994.[Abstract/Free Full Text]
  3. Barbera JA, Peinado VI, Santos S. Pulmonary hypertension in COPD: old and new concepts. Monaldi Arch Chest Dis 55: 445–449, 2000.[Medline]
  4. Brizzee BL, Walker BR. Chronic propranolol attenuates hypoxic pulmonary vasoconstriction in conscious rats. Respir Physiol 77: 55–64, 1989.[CrossRef][Web of Science][Medline]
  5. Fried R, Reid LM. Early recovery from hypoxic pulmonary hypertension: a structural and functional study. J Appl Physiol 57: 1247–1253, 1984.[Abstract/Free Full Text]
  6. Hislop A, Reid L. Changes in the pulmonary arteries of the rat during recovery from hypoxia-induced pulmonary hypertension. Br J Exp Pathol 58: 653–662, 1977.[Web of Science][Medline]
  7. Hislop A, Reid L. New findings in pulmonary arteries of rats with hypoxia-induced pulmonary hypertension. Br J Exp Pathol 57: 542–254, 1976.[Web of Science][Medline]
  8. Hislop A, Reid L. Normal structure and dimensions of the pulmonary arteries in the rat. J Anat 125: 71–83, 1978.[Web of Science][Medline]
  9. Howell K, Preston RJ, McLoughlin P. Chronic hypoxia causes angiogenesis in addition to remodelling in the adult rat pulmonary circulation. J Physiol 547: 133–145, 2003.[Abstract/Free Full Text]
  10. Ikai A, Shirai M, Nishimura K, Ikeda T, Kameyama T, Ueyama K, Komeda M. Maintenance of pulmonary vasculature tone by blood derived from the inferior vena cava in a rabbit model of cavopulmonary shunt. J Thorac Cardiovasc Surg 129: 199–206, 2005.[Abstract/Free Full Text]
  11. Kidoguchi K, Tamaki M, Mizobe T, Koyama J, Kondoh T, Kohmura E, Sakurai T, Yokono K, Umetani K.In vivo x-ray angiography in the mouse brain using synchrotron radiation. Stroke 37: 1856–1861 2006.[Abstract/Free Full Text]
  12. Kobayashi S, Hori M, Dono K, Nagano H, Umeshita K, Nakamori S, Sakon M, Osuga K, Umetani K, Murakami T, Nakamura H, Monden M. In vivo real-time microangiography of the liver in mice using synchrotron radiation. J Hepatol 40: 405–408, 2004.[CrossRef][Web of Science][Medline]
  13. Meyrick B, Fujiwara K, Reid L. Smooth muscle myosin in precursor and mature smooth muscle cells in normal pulmonary arteries and the effect of hypoxia. Exp Lung Res 2: 303–313, 1981.[Web of Science][Medline]
  14. Meyrick B, Hislop A, Reid L. Pulmonary arteries of the normal rat: the thick walled oblique muscle segment. J Anat 125: 209–221, 1978.[Web of Science][Medline]
  15. Meyrick B, Reid L. The effect of chronic hypoxia on pulmonary arteries in young rats. Exp Lung Res 2: 257–271, 1981.[Web of Science][Medline]
  16. Meyrick B, Reid L. The effect of continued hypoxia on rat pulmonary arterial circulation. An ultrastructural study. Lab Invest 38: 188–200, 1978.[Web of Science][Medline]
  17. Meyrick B, Reid L. Ultrastructural features of the distended pulmonary arteries of the normal rat. Anat Rec 193: 71–97, 1979.[CrossRef][Medline]
  18. Mori H, Hyodo K, Tanaka E, Mohammed MU, Yamakawa A, Shinozaki Y, Nakazawa H, Tanaka Y, Sekka T, Iwata Y, Handa S, Umetani K, Ueki H, Yokoyama T, Tanioka K, Kubota M, Hosaka H, Ishikawa N, Ando M. Small vessel radiography in situ with monochromatic synchrotron radiation. Radiology 201: 173–177, 1996.[Abstract/Free Full Text]
  19. Rabinovitch M, Gamble W, Nadas AS, Miettinen OS, Reid L. Rat pulmonary circulation after chronic hypoxia: hemodynamic and structural features. Am J Physiol Heart Circ Physiol 236: H818–H827, 1979.[Abstract/Free Full Text]
  20. Sasaki S, Kobayashi N, Dambara T, Kira S, Sakai T. Structural organization of pulmonary arteries in the rat lung. Anat Embryol (Berl) 191: 477–489, 1995.[Medline]
  21. Schwenke DO, Pearson JT, Mori H, Shirai M. Does central nitric oxide elicit pulmonary hypertension in conscious rats? Respir Physiol Neurobiol 153: 250–260, 2006.[CrossRef][Web of Science][Medline]
  22. Shirai M, Ikeda S, Min KY, Shimouchi A, Kawaguchi AT, Ninomiya I. Segmental differences in vasodilatation due to basal NO release in in vivo cat pulmonary vessels. Respir Physiol 116: 159–169, 1999.[CrossRef][Web of Science][Medline]
  23. Shirai M, Matsukawa K, Nishiura N, Kawaguchi AT, Ninomiya I. Changes in efferent pulmonary sympathetic nerve activity during systemic hypoxia in anesthetized cats. Am J Physiol Regul Integr Comp Physiol 269: R1404–R1409, 1995.[Abstract/Free Full Text]
  24. Shirai M, Pearson JT, Shimouchi A, Nagaya N, Tsuchimochi H, Ninomiya I, Mori H. Changes in functional and histological distributions of nitric oxide synthase caused by chronic hypoxia in rat small pulmonary arteries. Br J Pharmacol 139: 899–910, 2003.[CrossRef][Web of Science][Medline]
  25. Shirai M, Sada K, Ninomiya I. Effects of regional alveolar hypoxia and hypercapnia on small pulmonary vessels in cats. J Appl Physiol 61: 440–448, 1986.[Abstract/Free Full Text]
  26. Shirai M, Shimouchi A, Kawaguchi AT, Sunagawa K, Ninomiya I. Inhaled nitric oxide: diameter response patterns in feline small pulmonary arteries and veins. Am J Physiol Heart Circ Physiol 270: H974–H980, 1996.[Abstract/Free Full Text]
  27. Shirai M, Shindo T, Ninomiya I. beta-Adrenergic mechanisms attenuated hypoxic pulmonary vasoconstriction during systemic hypoxia in cats. Am J Physiol Heart Circ Physiol 266: H1777–H1785, 1994.[Abstract/Free Full Text]
  28. Tanaka A, Mori H, Tanaka E, Mohammed MU, Tanaka Y, Sekka T, Ito K, Shinozaki Y, Hyodo K, Ando M, Umetani K, Tanioka K, Kubota M, Abe S, Handa S, Nakazawa H. Branching patterns of intramural coronary vessels determined by microangiography using synchrotron radiation. Am J Physiol Heart Circ Physiol 276: H2262–H2267, 1999.[Abstract/Free Full Text]
  29. Tanaka E, Tanaka A, Sekka T, Shinozaki Y, Hyodo K, Umetani K, Mori H. Digitized cerebral synchrotron radiation angiography: quantitative evaluation of the canine circle of Willis and its large and small branches. Am J Neuroradiol 20: 801–806, 1999.[Abstract/Free Full Text]
  30. Tokiya R, Umetani K, Imai S, Yamashita T, Hiratsuka J, Imajo Y. Observation of microvasculatures in athymic nude rat transplanted tumor using synchrotron radiation microangiography system. Acad Radiol 11: 1039–1046, 2004.[CrossRef][Web of Science][Medline]
  31. Voelkel NF, Tuder RM. Hypoxia-induced pulmonary vascular remodeling: a model for what human disease? J Clin Invest 106: 733–738, 2000.[Web of Science][Medline]
  32. Widimsky J, Urbanova D, Ressl J, Ostadal B, Pelouch V, Prochazka J. Effect of intermittent altitude hypoxia on the myocardium and lesser circulation in the rat. Circ Res 7: 798–808, 1973.
  33. Yamashita T, Kawashima S, Ozaki M, Namiki M, Shinohara M, Inoue N, Hirata K, Umetani K, Yokoyama M. In vivo angiographic detection of vascular lesions in apolipoprotein E-knockout mice using a synchrotron radiation microangiography system. Circ J 66: 1057–1059, 2002.[CrossRef][Web of Science][Medline]



This article has been cited by other articles:


Home page
Am. J. Physiol. Lung Cell. Mol. Physiol.Home page
W. Lu, J. Wang, G. Peng, L. A. Shimoda, and J. T. Sylvester
Knockdown of stromal interaction molecule 1 attenuates store-operated Ca2+ entry and Ca2+ responses to acute hypoxia in pulmonary arterial smooth muscle
Am J Physiol Lung Cell Mol Physiol, July 1, 2009; 297(1): L17 - L25.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Renal Physiol.Home page
G. A. Eppel, D. L. Jacono, M. Shirai, K. Umetani, R. G. Evans, and J. T. Pearson
Contrast angiography of the rat renal microcirculation in vivo using synchrotron radiation
Am J Physiol Renal Physiol, May 1, 2009; 296(5): F1023 - F1031.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Lung Cell. Mol. Physiol.Home page
W. Lu, J. Wang, L. A. Shimoda, and J. T. Sylvester
Differences in STIM1 and TRPC expression in proximal and distal pulmonary arterial smooth muscle are associated with differences in Ca2+ responses to hypoxia
Am J Physiol Lung Cell Mol Physiol, July 1, 2008; 295(1): L104 - L113.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
D. O. Schwenke, J. T. Pearson, K. Kangawa, K. Umetani, and M. Shirai
Changes in macrovessel pulmonary blood flow distribution following chronic hypoxia: assessed using synchrotron radiation microangiography
J Appl Physiol, January 1, 2008; 104(1): 88 - 96.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF) Free
Right arrow All Versions of this Article:
102/2/787    most recent
00596.2006v1
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schwenke, D. O.
Right arrow Articles by Shirai, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schwenke, D. O.
Right arrow Articles by Shirai, M.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online
Copyright © 2007 by the American Physiological Society.