Journal of Applied Physiology Information on EB 2010
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 101: 707-714, 2006. First published May 11, 2006; doi:10.1152/japplphysiol.00154.2006
8750-7587/06 $8.00
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF) Free
Right arrow All Versions of this Article:
101/3/707    most recent
00154.2006v1
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (6)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Berger, N. J. A.
Right arrow Articles by Jones, A. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Berger, N. J. A.
Right arrow Articles by Jones, A. M.

Influence of acute plasma volume expansion on VO2 kinetics, VO2peak, and performance during high-intensity cycle exercise

Nicolas J. A. Berger,1 Iain T. Campbell,2 Daryl P. Wilkerson,1 and Andrew M. Jones1

1Department of Exercise and Sport Science, Manchester Metropolitan University, Alsager; and 2Department of Anaesthesia, Wythenshawe Hospital, Manchester, United Kingdom

Submitted 7 February 2006 ; accepted in final form 9 May 2006


    ABSTRACT
 TOP
 ABSTRACT
 METHODS
 RESULTS
 DISCUSSION
 ACKNOWLEDGMENTS
 REFERENCES
 
The purpose of this study was to examine the influence of acute plasma volume expansion (APVE) on oxygen uptake (VO2) kinetics, VO2peak, and time to exhaustion during severe-intensity exercise. Eight recreationally active men performed "step" cycle ergometer exercise tests at a work rate requiring 70% of the difference between the gas-exchange threshold and VO2max on three occasions: twice as a "control" (Con) and once after intravenous infusion of a plasma volume expander (Gelofusine; 7 ml/kg body mass). Pulmonary gas exchange was measured breath by breath. APVE resulted in a significant reduction in hemoglobin concentration (preinfusion: 16.0 ± 1.0 vs. postinfusion: 14.7 ± 0.8 g/dl; P < 0.001) and hematocrit (preinfusion: 44 ± 2 vs. postinfusion: 41 ± 3%; P < 0.01). Despite this reduction in arterial O2 content, APVE had no effect on VO2 kinetics (phase II time constant, Con: 33 ± 15 vs. APVE: 34 ± 12 s; P = 0.74), and actually resulted in an increased VO2peak (Con: 3.90 ± 0.56 vs. APVE: 4.12 ± 0.55 l/min; P = 0.006) and time to exhaustion (Con: 365 ± 58 vs. APVE: 424 ± 64 s; P = 0.04). The maximum O2 pulse was also enhanced by the treatment (Con: 21.3 ± 3.4 vs. APVE: 22.7 ± 3.4 ml/beat; P = 0.04). In conclusion, APVE does not alter VO2 kinetics but enhances VO2peak and exercise tolerance during high-intensity cycle exercise in young recreationally active subjects.

blood volume; endurance; O2 kinetics; performance


THERE IS POWERFUL EVIDENCE that the delivery of O2 to the working muscles is the principal determinant of the maximal O2 uptake (VO2max) attained during large muscle group exercise (22). For example, acute alterations of red cell mass caused by the withdrawal (9, 18, 54) and reinfusion (18, 55) of whole blood have consistently resulted in changes in VO2max that are proportional to changes in the hemoglobin concentration ([Hb]). An alternative method for altering [Hb], and thus the arterial O2 content, is through acute plasma volume expansion (APVE). However, the influence of the hypervolemia caused by APVE on VO2max is controversial, with reports of no changes (38, 39, 46, 57), and even increases (15, 16, 42) in VO2max appearing in the literature. The possibility of an unchanged or increased VO2max with APVE (which reduces [Hb]) might seem intuitively paradoxical. However, it has been demonstrated that APVE increases stroke volume (SV) and thus cardiac output (Q) by the Frank-Starling mechanism (30, 31, 38, 42, 46, 57). This effect is apparently capable of offsetting the reduced [Hb] with APVE such that muscle O2 delivery is preserved, or even enhanced, during maximal-intensity exercise (21, 30, 31). The extent to which APVE can increase Q and VO2max appears to depend on the training status of the subjects (endurance-trained subjects already have an enlarged plasma volume; Ref. 12) and the volume of fluid infused (15, 16, 42, 57).

The influence of APVE on exercise tolerance is similarly ambiguous. APVE has been reported to reduce (15, 38, 39), improve (16, 43), or have no effect on (46, 57) time to exhaustion during endurance exercise. Whether APVE results in an enhanced endurance exercise capacity might be related to the interaction of the possible positive effects of APVE on VO2max and the possible negative effects of APVE on muscle lactate production and blood buffering capacity (15, 16, 43). One factor that has not been considered as a possible explanation for the changes in endurance performance invoked by APVE is the magnitude of the "O2 deficit" incurred across the transition from rest to exercise. A lower muscle O2 delivery caused by a reduced [Hb] with APVE could increase the O2 deficit and impair exercise performance by increasing the "anaerobic" contribution to energy transfer, with consequently greater perturbation to intracellular homeostasis (e.g., decreased muscle phosphocreatine concentration and pH; increased inorganic phosphate and lactate accumulation). On the other hand, an increased Q with APVE could result in an unchanged (or reduced) O2 deficit and an enhanced VO2max, potentially enhancing exercise performance.

In this respect, it is noteworthy that the rate at which pulmonary [and, by inference (23), muscle] VO2 rises after the onset of constant-work-rate exercise (i.e., the VO2 "kinetics," an important determinant of the O2 deficit) has been reported to be significantly faster after only 4–7 days of endurance exercise training in previously sedentary subjects (20, 47, 64). This adaptation has been reported to occur more rapidly than the increase in muscle oxidative capacity, and it has been speculated that this could be related to an enhanced cardiovascular response to exercise (47). One of the earliest adaptations to endurance training is a rapid expansion of the plasma volume; a 12–20% increase in plasma volume has been reported after just 4–8 days of intense training (12–14, 24, 25). Therefore the early speeding of VO2 kinetics noted with endurance training might be related, at least in part, to adaptations in Q and muscle O2 availability resulting from the training-induced hypervolemia. Surprisingly, the influence of APVE on VO2 kinetics and the O2 deficit has not been specifically investigated.

The principal purpose of this study was to investigate the influence of APVE on pulmonary VO2 kinetics during severe-intensity upright cycle ergometer exercise. A secondary purpose was to examine the effect of APVE on VO2peak and exercise tolerance. To mimic the early effects of endurance training on plasma volume, we recruited active but not specifically trained subjects and used a moderate level of plasma volume expansion (7 ml/kg). We hypothesized that APVE would result in 1) a speeding of the VO2 kinetics; 2) an increased VO2peak; and, therefore, 3) an enhanced exercise performance.


    METHODS
 TOP
 ABSTRACT
 METHODS
 RESULTS
 DISCUSSION
 ACKNOWLEDGMENTS
 REFERENCES
 
Subjects.   Eight healthy men (age 27 ± 4 yr; height 1.84 ± 0.05 m; body mass 83.7 ± 5.0 kg; means ± SD) volunteered and gave written, informed consent to participate in this study, which had received approval from the local Research Ethics Committee. The subjects were occasionally active in recreational sports activities but were not highly trained. They were fully familiar with the exercise testing procedures employed in the study. The subjects were instructed to arrive at the laboratory at the same time of day (±1 h), having performed no heavy exercise during the previous 24 h, and having consumed no food, caffeine, or alcohol during the previous 3 h.

Procedures.   The subjects attended the laboratory on four occasions over a 4-wk period to perform exercise tests on the cycle ergometer. The first visit was used to establish VO2max and to estimate the gas-exchange threshold (GET). On each of the three subsequent visits, subjects completed a single bout of severe-intensity exercise to the limit of tolerance: "control" bouts were completed on two occasions, whereas the exercise trial was preceded by APVE on the remaining occasion. The APVE and control bouts were presented to the subjects in random order and were each separated by 7–10 days. It has been reported that control plasma volume is reestablished within 7 days of APVE (14). The APVE trial was completed only once because of ethical concerns over the physiological effects of repeated cannulation and plasma volume expansion.

All testing was performed on an electronically braked cycle ergometer (Lode Excalibur Sport, Groningen, The Netherlands) in a well-ventilated laboratory at a temperature of 20–22°C. During the first visit to the laboratory, the ergometer was adjusted so that each subject was comfortable, and the settings were recorded and replicated during all subsequent exercise tests. After measurement of height and body mass, subjects performed a "ramp" incremental exercise test to determine VO2max and GET. This test consisted of 3 min of pedaling against no external resistance, followed by a continuous ramped increase in work rate of 30 W/min until the limit of tolerance. The pedal rate selected by each of the subjects in this test (typically 80–85 rpm) was employed during all subsequent tests. All gas-exchange and ventilatory variables were averaged and displayed over 10-s intervals. The VO2max was determined as the highest VO2 measured over 30 s, and the GET was determined using the V-slope method (6). The work rate corresponding to 70% "{Delta}" (i.e., 70% of the difference between GET and VO2peak, i.e., "severe" exercise; Ref. 49) was calculated by linear regression of VO2 vs. work rate with account taken of the lag in VO2 relative to work rate that exists during ramp incremental exercise (58).

On each of the three subsequent laboratory visits and prior to the commencement of the "step" exercise tests, the subjects rested for 10 min before blood samples from a prewarmed fingertip were collected into heparinized microhematocrit tubes (Hawksley and Sons, Sussex, UK) and microcuvettes (HemoCue AB, Ängelholm, Sweden) for the determination of hematocrit (Hct; Hawksley 1560 Microhematocrit reader) and hemoglobin (B-Hemoglobin photometer, HemoCue AB), respectively. Blood pressure was measured using a manual sphygmomanometer, and mean arterial pressure (MAP) was subsequently determined as the diastolic pressure plus one-third of the pulse pressure. In both the control and experimental conditions, subjects then lay in the prone position for 35 min. In the experimental condition, a hand vein was cannulated and an infusion pump was programmed to administer 7 ml/kg body mass of a clinical plasma volume expander (Gelofusine; Braun, Sheffield, UK) over a 30-min period. The subjects then moved to the cycle ergometer and sat at rest for 10 min, after which blood samples were again collected and blood pressure was measured. The subjects then performed a single severe-intensity exercise bout to the limit of tolerance. In each case, the test commenced with 3 min of pedaling against no external resistance after which the work rate was abruptly increased to the target work rate. Subjects were given strong verbal encouragement throughout the exercise test, and the time to exhaustion was recorded to the nearest second. Within 30 s of the completion of the exercise test, a final set of blood samples for determination of Hct and [Hb] were collected, and blood pressure was again measured. Immediately before the onset of loaded exercise, every 2 min throughout exercise, and immediately upon the cessation of exercise, fingertip blood samples were collected into capillary tubes for the determination of blood lactate concentration by using a semiautomated analyzer (YSI 1500, Yellow Springs Instruments, Yellow Springs, OH).

Pulmonary gas exchange and ventilation were measured breath by breath with subjects wearing a nose clip and breathing through a low-dead space (90 ml), low-resistance (0.75 mmHg·l–1·s–1 at 15 l/s) mouthpiece and impeller turbine assembly (Jaeger Triple V). The inspired and expired gas volume and gas concentration signals were continuously sampled at 100 Hz, the latter using paramagnetic (O2) and infrared (CO2) analyzers (Jaeger Oxycon Pro, Hoechberg, Germany) via a capillary line connected to the mouthpiece. The gas analyzers were calibrated before each test with gases of known concentration, and the turbine volume transducer was calibrated by using a 3-liter syringe (Hans Rudolph, Kansas City, MO). The volume and concentration signals were time aligned by accounting for the delay in the capillary gas transit and the analyzer rise time relative to the volume signal. VO2, CO2 production, and minute ventilation were calculated by using the algorithms of Beaver et al. (5) and displayed breath by breath. Heart rate (HR) was measured every 5-s using short-range radio telemetry (Polar S610, Polar Electro Oy, Kempele, Finland). O2 pulse was calculated as Q/HR.

The breath-by-breath data from the step exercise tests were used to estimate the VO2 kinetics. The data were first manually filtered to remove outlying breaths, defined as breaths deviating by more than three standard deviations from the preceding five breaths. The data were subsequently interpolated to provide second-by-second values, and, for each individual, the data sets from the control condition were time aligned and averaged.

The first 20 s of data after the onset of exercise (i.e., the phase I response) were deleted and a nonlinear least-square algorithm was used to fit the data as described in the following biexponential equation:

Formula
where VO2(t) represents the absolute VO2 at a given time t; VO2baseline represents the mean VO2 in the final 2 min of the baseline period; Ap, TDp, and {tau}p represent the amplitude, time delay, and time constant, respectively, describing the fundamental or primary increase in VO2 above baseline; and As, TDs, and {tau}s represent the amplitude, time delay, and time constant describing the development of the VO2 slow component, respectively. An iterative process was used to minimize the sum of the squared errors between the fitted function and the observed values. The asymptotic value (As) of the exponential term describing the VO2 slow component may represent a higher value than is actually reached at the end of the exercise and therefore the actual amplitude of the VO2 slow component at the end of exercise was used and defined as As.

The most appropriate approach for the computation of the O2 deficit during high-intensity exercise that invokes a VO2 slow component response is unclear (59) and so, in the present study, the O2 deficit over just the "primary" phase of the response was calculated by using the formula (TDp + {tau}p)/60·Ap.

Statistical analysis.   The results are presented as means ± SD. Analysis of variance was used to determine the significance of any differences between the hematological variables at rest and during exercise in the control and APVE conditions. When an overall difference was found, post hoc Bonferroni-adjusted paired t-tests were used to examine significant differences among means. Paired t-tests were used to examine differences between the APVE and control conditions with respect to VO2 kinetics, VO2peak, and time to exhaustion. Statistical significance was accepted when P was less than 0.05.


    RESULTS
 TOP
 ABSTRACT
 METHODS
 RESULTS
 DISCUSSION
 ACKNOWLEDGMENTS
 REFERENCES
 
The VO2max of the subjects measured during the ramp incremental test was 4.06 ± 0.42 l/min (48.7 ± 6.6 ml·kg–1·min–1), and the highest work rate attained was 379 ± 37 W. The GET occurred at a mean VO2 of 2.05 ± 0.41 l/min or 50 ± 6% VO2max. The work rate equivalent to 70% {Delta} was 303 ± 33 W.

The influence of APVE on [Hb] and Hct is illustrated in Fig. 1. APVE resulted in an 8% reduction in [Hb] [preinfusion (pre): 16.0 ± 1.0 vs. postinfusion (post): 14.7 ± 0.8 g/dl; P < 0.001] and Hct (pre: 44 ± 2 vs. post: 41 ± 3%; P < 0.01), but there was no significant difference in the control condition for either [Hb] (pre: 15.8 ± 0.9 vs. post: 15.5 ± 0.8 g/dl; P = 0.20) or Hct (pre: 43 ± 1 vs. post: 43 ± 2%; P = 0.51). Exercise was associated with a hemoconcentration in both conditions, but [Hb] remained significantly lower at the end of exercise after APVE [control (Con): 17.3 ± 0.9 g/dl vs. APVE: 16.0 ± 1.5 g/dl; P < 0.05; Fig. 1]. The mean change in plasma volume, calculated by the methods of Dill and Costill (17), was 14%. MAP was not significantly different between the conditions on first measurement (Con: 95 ± 7 vs. APVE: 97 ± 10 mmHg; P = 0.66), after the rest or infusion period (Con: 96 ± 12 vs. APVE: 99 ± 4 mmHg; P = 0.56), or immediately after exercise (Con: 115 ± 15 vs. APVE: 117 ± 12 mmHg; P = 0.60).


Figure 1
View larger version (10K):
[in this window]
[in a new window]
 
Fig. 1. Mean ± SD hemoglobin concentration (top) and hematocrit (bottom) in the control condition (open bars) and after acute plasma volume expansion (solid bars) before and after infusion, and postexercise. *Significantly different from control condition (P < 0.05); {dagger}significantly different from preinfusion (P < 0.001); §significantly different from postinfusion (P < 0.05); £significantly different from preinfusion (P < 0.01); $significantly different from postinfusion (P < 0.01). Hematocrit values were not corrected for trapped plasma or for peripheral sampling.

 
The model parameters describing the VO2 kinetic response to exercise are shown in Table 1, and the VO2 responses of a representative subject in the control and APVE conditions are shown in Fig. 2. APVE had no significant effect on baseline VO2 or on the parameters describing the primary phase of the VO2 response (TDp, {tau}p, or Ap). Of particular importance with reference to the purpose of the present study was that the group mean {tau} was almost identical between the two conditions (Con: 33 ± 15 vs. APVE: 34 ± 12 s; P = 0.74). The 95% confidence interval surrounding the estimate of {tau}p was 4 ± 2 s for Con and 5 ± 3 s for APVE. The magnitude of the O2 deficit incurred over the primary phase of the response did not differ between the Con and APVE conditions (Table 1). The model parameters describing the VO2 slow component response were also not significantly different between the two conditions (Con: 0.63 ± 0.16 vs. APVE: 0.86 ± 0.39 l/min; P = 0.12).


View this table:
[in this window]
[in a new window]
 
Table 1. Parameters of the VO2 kinetic response to severe-intensity cycle exercise with and without acute plasma volume expansion VO2

 

Figure 2
View larger version (24K):
[in this window]
[in a new window]
 
Fig. 2. O2 uptake (VO2) response of a representative subject to severe-intensity cycle exercise in the control condition (top) and after acute plasma volume expansion (APVE; middle). Gray curves represent the model fits to the data with the residuals to the model fits shown at the foot of each panel. The horizontal dotted line represents the maximum O2 uptake as measured during a preliminary ramp incremental test. The responses to the control and APVE conditions are superimposed in the bottom. Note the similar kinetic response profiles, but the higher end-exercise VO2 and the extended time to exhaustion after APVE.

 
Compared with the control condition, APVE resulted in a small but statistically significant 6% increase in the highest (end-exercise) VO2 attained (Con: 3.90 ± 0.56 vs. APVE: 4.12 ± 0.55 l/min; P = 0.006; Fig. 3). However, the end-exercise VO2 values attained in the control and APVE step tests did not differ significantly from the VO2max value attained during the initial ramp incremental exercise test (4.06 ± 0.42 l/min). The time to exhaustion was not significantly different between the first and second control tests (360 ± 68 and 369 ± 56 s, respectively; P = 0.57); however, the time to exhaustion was 16% greater after APVE compared with the average time to exhaustion in the control condition (Con: 365 ± 58 vs. APVE: 424 ± 64 s; P = 0.04; Fig. 2).


Figure 3
View larger version (11K):
[in this window]
[in a new window]
 
Fig. 3. Mean ± SD VO2 response to severe-intensity cycle exercise in the control condition (open bars) and after APVE (solid bars). Note that VO2 was unchanged during submaximal exercise and was significantly higher (P < 0.01) at the end of exercise with APVE despite the significantly lower hemoglobin concentration in this condition.

 
Blood lactate concentration was not significantly different between the two conditions at baseline (Con: 1.0 ± 0.3 vs. APVE: 1.1 ± 0.4; P = 0.67), 2 min of exercise (Con: 2.3 ± 0.4 vs. APVE: 2.1 ± 0.6; P = 0.50), 4 min of exercise (Con: 4.9 ± 0.8 vs. APVE: 4.9 ± 1.0; P = 0.98), 6 min of exercise (Con: 6.1 ± 0.7 vs. APVE: 7.2 ± 1.1; P = 0.20), or the end of exercise (Con: 7.1 ± 1.5 vs. APVE: 8.2 ± 1.8; P = 0.19). The HR responses to exercise in the control and APVE conditions are shown in Fig. 4. There were no significant differences between the conditions at baseline or at any time point during exercise including the end-exercise value (Con: 184 ± 9 vs. APVE: 183 ± 10 b/min; P = 0.77). Similarly, the O2 pulse was not significantly different between the control and APVE conditions across the exercise transient (Fig. 5). However, the maximal O2 pulse was 7% higher after APVE (Con: 21.3 ± 3.4 vs. APVE: 22.7 ± 3.4 ml/beat; P = 0.04; Fig. 5).


Figure 4
View larger version (5K):
[in this window]
[in a new window]
 
Fig. 4. Mean ± SD heart rate (HR) response to severe-intensity cycle exercise in the control condition ({lozenge}) and after acute plasma volume expansion ({blacklozenge}).

 

Figure 5
View larger version (7K):
[in this window]
[in a new window]
 
Fig. 5. Mean ± SD O2 pulse (i.e., VO2/HR) response to severe-intensity cycle exercise in the control condition ({lozenge}) and after APVE ({blacklozenge}). The maximum O2 pulse was significantly higher after APVE (P < 0.05).

 

    DISCUSSION
 TOP
 ABSTRACT
 METHODS
 RESULTS
 DISCUSSION
 ACKNOWLEDGMENTS
 REFERENCES
 
The principal findings of this study were that APVE (at 7 ml/kg body mass; ~500–650 ml) had no effect on VO2 kinetics (and thus the O2 deficit) but resulted in significant enhancements of VO2peak and exercise tolerance during severe-intensity constant-work-rate cycle ergometer exercise in healthy, recreationally active subjects. These effects occurred despite a significant reduction in [Hb] and Hct after APVE and indicate that the reduction in arterial O2 content achieved with APVE did not adversely influence VO2 kinetics, VO2peak, or the performance of high-intensity exercise.

Influence of APVE on [Hb] and Hct.   APVE resulted in an 8% reduction of [Hb] and Hct (equivalent to a 14% expansion of the plasma volume; Ref. 17), both before and after exercise (Fig. 1). The magnitude of the effects observed are entirely consistent with the results of previous studies in which similar volumes of fluid were infused (15, 16, 30, 57). Also, these effects are similar to those observed after a few days of intense endurance training in previously untrained subjects where plasma volume is typically elevated by 12–20% (12–14, 24, 25, 27). Our experimental design was therefore successful in artificially reproducing the physiological expansion of the plasma volume that occurs shortly after the commencement of an endurance training program.

Influence of APVE on VO2 kinetics.   To our knowledge, this is the first study to directly investigate the influence of APVE on VO2 kinetics and the O2 deficit after the onset of high-intensity constant-work-rate exercise. The rate at which VO2 rises after the onset of exercise is finite and might be limited in different situations either locally by an inertia of the oxidative metabolic enzymes in the contracting myocytes, or systemically by the delivery of O2 to its sites of utilization (32, 37). If O2 delivery represents an important limitation to VO2 kinetics, then the reduced [Hb] brought about by APVE might be hypothesized to result in a slower VO2 response after the onset of exercise. The fact that VO2 kinetics was not influenced by APVE in the present study therefore suggests either that 1) muscle O2 delivery does not limit VO2 kinetics during severe-intensity upright cycle exercise in healthy young subjects or 2) adjustments in muscle blood flow, or in muscle O2 extraction, across the exercise transient were sufficient to negate the effect of the reduced arterial O2 content.

With regard to the first possibility, several studies have examined the effect of interventions designed to either reduce muscle O2 delivery [using, for example, hypoxia (19, 45), altered body position or perfusion pressure (41, 44, 63), beta-blockade (35), and blood letting (9)], or to enhance muscle O2 delivery [using, for example, hyperoxia (45, 61), prior exercise models (8, 56), and human recombinant erythropoietin (RhEPO) treatment (11, 62)], with equivocal results. The consensus view is that VO2 kinetics are principally regulated by intracellular mechanisms but that muscle O2 availability might represent an additional limitation in some circumstances (depending on a combination of factors including the exercise intensity, the exercise modality, and the characteristics of the subjects studied; Ref. 37). It is therefore possible that a small reduction in muscle O2 delivery caused by APVE did not impact on VO2 kinetics because muscle O2 delivery exceeded the capacity of the muscle to extract O2 in the control condition, as suggested by the results of several previous investigations (2, 23, 63).

With regard to the second possibility, it was evident that neither HR nor O2 pulse were altered across the exercise transient after APVE (Figs. 4 and 5). Another explanation for the unaltered VO2 kinetics after APVE is therefore that SV (and hence Q and muscle blood flow) was increased across the exercise transient in the APVE condition so that muscle O2 delivery was not appreciably different from the control condition (16, 30, 42) and/or that muscle O2 extraction was enhanced. Accordingly, Calbet et al. (10) have recently reported a significantly increased leg blood flow and O2 extraction with APVE so that muscle O2 delivery and uptake were unchanged relative to the control condition during submaximal exercise. The available evidence therefore indicates that 5–8% reductions in [Hb] caused either by APVE (present study) or by blood letting (9) do not measurably impact on VO2 kinetics, whereas reductions in muscle perfusion pressure (brought about by altering body position; Refs. 33, 41, 44; but see also Ref. 63) or in O2 driving pressure from the muscle capillary to the mitochondrion (achieved in hypoxia; Refs. 19, 34) have the potential to slow VO2 kinetics. Presumably these latter interventions result in more substantial reductions in muscle O2 availability that cannot be easily negated by compensatory increases in muscle blood flow.

In the present study, APVE was induced "artificially," i.e., through intravenous infusion of fluid. However, a similar effect occurs physiologically after the commencement of an endurance exercise training program. Indeed, increases in plasma volume of 400–600 ml or more have been measured after the completion of just a few training sessions and linked to improvements in markers of aerobic fitness (12–14, 25, 27). Interestingly, VO2 kinetics also appear to adapt remarkably quickly to endurance training with a speeding of the primary VO2 response being manifest within 4–7 days of the commencement of training (20, 47, 64). Phillips et al. (47) reported that this speeding of VO2 kinetics occurred before any measurable increase in citrate synthase activity (a key mitochondrial enzyme) and suggested that alterations in cardiovascular regulation ultimately manifesting in an increased leg blood flow might have been responsible for the effects observed. Plasma volume expansion has been demonstrated to enhance SV and Q (30, 31, 38, 42, 46, 57), and therefore hypervolemia might be hypothesized to contribute, in part, to the early speeding of VO2 kinetics observed soon after the commencement of endurance exercise training, assuming that any increase in Q translated into an increased leg blood flow and O2 delivery (see Limitations). However, there was no evidence to support this hypothesis in the present study because VO2 kinetics and the O2 deficit were unchanged after APVE. Therefore, the speeding of the VO2 kinetics observed during the first 4–7 days of endurance training must be explained by other factors such as a better local matching of blood flow to metabolic rate (36) and/or upregulation of the key rate-limiting enzymes for oxidative metabolism (7). The available evidence suggests that a significant increase in muscle capillarity is not evident until after some 10–21 days of training (1, 26, 32), indicating that changes in the muscle microcirculation are not responsible for the early speeding of the VO2 kinetics that has been reported. Interestingly, in contradiction to Phillips et al. (47), Burgomaster et al. (7) have recently reported a 38% increase in maximal citrate synthase activity after 3 days of high-intensity training. These data suggest that an increased muscle oxidative capacity might play an important role in the rapid enhancement of the VO2 response dynamics caused by endurance training.

After the onset of exercise above the GET, pulmonary VO2 rises toward the "initially anticipated" steady-state requirement for the work rate (3); however, after some 2–3 min, a secondary component of the VO2 response emerges (60). This VO2 "slow component" reduces metabolic efficiency by elevating VO2 above the expected value (for all work rates above the GET); for all work rates above the so-called "critical power," VO2 is set on a trajectory toward its maximum (49). For this reason, and because its development is associated both with a metabolic acidosis and a continued decline in intramuscular phosphocreatine concentration (51), the VO2 slow component has been assumed to be inextricably linked to the fatigue process (48). In the present study, however, exercise tolerance was enhanced despite there being no significant alteration in the amplitude of the VO2 slow component. The relationship between the magnitude of the VO2 slow component and exercise tolerance is clearly not straightforward and will depend, in part, on the extent to which experimental interventions influence the amplitude of the primary phase of the response and/or the VO2peak (Refs. 8, 9, 61, 62; present study).

Influence of APVE on VO2peak and exercise tolerance.   APVE resulted in a 6% increase in the highest VO2 attained during the exercise test despite the simultaneous 8% reduction in [Hb] caused by the procedure. Because VO2max during large muscle group exercise such as cycle ergometry is believed to be principally dependent on muscle O2 delivery (22), these results suggest that APVE enabled the attainment of a higher maximal Q (and thence muscle O2 delivery) that more than compensated for the reduced arterial O2 content. There was a significantly higher maximum O2 pulse after APVE (Fig. 5). According to the Fick principle, Q/HR = SV x C(a-v)O2, where C(a-v)O2 is the arterial-mixed venous O2 content difference. Therefore, the increased maximum O2 pulse observed after APVE might have resulted from an increased SV. At the same maximum HR (as was observed in the present study; Fig. 4), the increased SV would increase the maximum Q. There is substantial evidence that SV is increased by APVE as a result of increased preload and diastolic filling that enhances ventricular emptying by the Frank-Starling mechanism (30, 31, 38, 40, 42, 46, 57). In this light, our results appear to be consistent with the study of Krip et al. (42) in which a 10% expansion of the plasma volume resulted in a 9% increase in SV and Q and a 7% increase in VO2max.

The MAP measured shortly after the termination of exercise was not significantly different between the two conditions in the present study, suggesting that any increase in Q was counterbalanced by a reduction in total peripheral resistance. There might be little scope for further redistribution of Q toward the working muscles during high-intensity exercise of the type investigated in the present study (52), and it is unclear what proportion of the increased Q might have been directed to the exercising muscles relative to other vascular beds. The latter will depend, in part, on possible changes in norepinephrine spillover across the legs relative to these other vascular beds. Calbet et al. (10) reported that leg vascular conductance was increased by APVE, although the mechanism(s) responsible for this effect were unclear. When the work of breathing was reduced by use of a proportional-assist ventilator during maximal-intensity exercise, Q was reduced but leg blood flow and VO2 were increased as a consequence of a reduction in muscle sympathetic nerve activity (and therefore leg vascular resistance) at similar MAP (28, 29). In a similar fashion, it is possible that APVE might reduce the output of the pulmonary reflexes (through as yet undefined mechanisms), leading to less vasoconstriction in the exercising limb, and enabling exercise to be continued longer and a higher VO2 to be attained.

The increased maximum O2 pulse after APVE could also be explained by an increased maximal C(a-v)O2. However, this might be considered unlikely because muscle O2 extraction would be near maximal during high-intensity exercise of this type (10, 28). Indeed, any increase in intracapillary spacing of erythrocytes after APVE might be predicted to reduce muscle O2 diffusing capacity (38, 54). On the other hand, APVE would be expected to reduce blood viscosity and this might, in turn, enable a faster blood flow through the muscle capillaries such that O2 extraction is preserved, as shown by Calbet et al. (10). It is, however, difficult to know what effect systemic changes in Hct might have on capillary Hct and hemodynamics. For example, Sarelius (53) reported that neither capillary red blood cell flux nor velocity were different in hamster cremaster muscles when the systemic Hct was reduced to either 49 or 32% of normal and concluded that tissue O2 delivery from capillaries cannot be predicted from measured changes in systemic O2 transport capacity.

The influence of APVE on VO2max is equivocal, with previous studies reporting either no change (10, 38, 39, 46, 57) or enhancements (15, 16, 42) of VO2max after APVE. The divergent results might be explained by an interaction of the magnitude of the plasma volume expansion and the training status of the subjects (15, 16, 42, 57). It is possible that a particularly large reduction in [Hb] caused by a substantial expansion of the plasma volume (i.e., >700 ml) might exceed the potential for compensatory alterations in SV and Q to maintain muscle O2 delivery, such that VO2max is reduced. Aerobic exercise training results in a physiological hypervolemia (12), and therefore endurance athletes might be especially sensitive to a reduction in VO2max if plasma volume undergoes substantial "additional" expansion using artificial means (16, 30, 57). Clearly, the potential for APVE to enhance VO2max depends on striking a delicate balance between the potentially negative effects of a reduced [Hb] and the potentially positive effects of an increased SV. It appears logical that lesser trained subjects, such as those used in the present study, would stand to benefit more from larger blood volume loading than would better trained subjects in whom the plasma volume is already elevated (12). Previous studies indicate that the infusion of fluid volumes of ~250–500 ml might positively impact on VO2max and exercise performance in untrained subjects (15, 16, 42, 43), whereas volumes of greater than ~650 ml might have a detrimental effect (16, 38, 39). The present study demonstrates that positive effects on aerobic function are still possible when fluid volumes of ~500–650 ml are infused in recreationally active subjects.

APVE resulted in a 59-s (16%) increase in the time to exhaustion. This is consistent with some (16, 43), but not all (15, 38, 39, 46, 57), previous studies. During exhaustive exercise 6–7 min in duration, the VO2max is recognized to be an important determinant of performance (4). Therefore, because APVE did not influence the magnitude of the O2 deficit in the "fundamental" phase of the response, we presume that the increased exercise tolerance after APVE was secondary to the enhanced VO2peak (Fig. 2). During severe-intensity constant-work-rate exercise, there is evidence that the termination of exercise coincides with the attainment of a VO2 that is close to the VO2max attained during incremental exercise (49, 50, 56, 61). Muscle energy turnover continues to rise with time during high-intensity constant-work-rate exercise (51). Once the energy supplied through oxidative phosphorylation reaches its maximum rate, there is therefore likely to be a more rapid fall in the concentration of muscle high-energy phosphates and a greater accumulation of metabolites that have been linked to the fatigue process (i.e., hydrogen ions and inorganic phosphate). The increased VO2peak with APVE presumably delayed these effects and so enabled a prolongation of exercise performance.

We have recently examined the effect of blood withdrawal (which reduced [Hb] by 5%; Ref. 9) and RhEPO treatment (which increased [Hb] by 7%; Ref. 62) on the physiological responses to severe-intensity exercise in subjects of similar fitness to those of the present study. Blood withdrawal reduced VO2peak by 4% and time to exhaustion by 14% (9), whereas RhEPO treatment increased VO2peak by 7% and time to exhaustion by 22% (62). Although APVE reduced [Hb] to a greater extent than did blood withdrawal, the effects on VO2peak and time to exhaustion were similar to those reported after RhEPO treatment. This striking observation underlines the importance of both [Hb] and the total blood volume in the determination of VO2peak and endurance exercise performance (21, 38).

Limitations.   The main purpose of the present study was to examine the influence of APVE on pulmonary VO2 kinetics during large muscle group exercise (upright cycling). However, whereas our results might be interpreted in the light of previously published studies to indicate that muscle blood flow and/or O2 extraction were enhanced after APVE (such that VO2 across the transient was preserved and VO2peak was enhanced), neither variable was directly measured in the present study. The measurement of SV, Q, muscle blood flow, and O2 extraction is technically challenging during upright cycle exercise, and it is possible that the highly invasive nature of these measurements could adversely affect the fidelity of the pulmonary VO2 signal. The potential mechanism(s) for the effect of APVE on VO2peak therefore awaits further investigation. Another limitation to our study was that subjects were not blinded to the experimental intervention. However, we are confident that the performance test was reliable (<3% difference in time to exhaustion between the first and second control bouts) and that subjects gave a maximum effort on all occasions (end-exercise HR and blood lactate concentration were not significantly different between the APVE and control conditions).

In conclusion, despite causing a significant reduction in systemic [Hb], APVE (at 7 ml/kg body mass) did not alter VO2 kinetics but did result in an increased VO2peak and an extended time to exhaustion during severe-intensity cycle exercise in recreationally active young men. The lack of effect of APVE on VO2 kinetics suggests that muscle O2 delivery does not limit oxidative metabolism in the transient phase of exercise of this type and/or that alterations in Q (mediated through an increased SV) or its distribution, or increased muscle O2 extraction, are able to compensate for the reduced arterial O2 content. The increased VO2peak, maximum O2 pulse, and exercise tolerance with APVE observed in the present study confirm the results of several previous studies and indicate that APVE enables an increased muscle blood flow and/or O2 extraction that is sufficient to surmount the potentially negative effects of reduced [Hb] on muscle O2 transport.


    ACKNOWLEDGMENTS
 TOP
 ABSTRACT
 METHODS
 RESULTS
 DISCUSSION
 ACKNOWLEDGMENTS
 REFERENCES
 
Present address for N. J. A. Berger, D. P. Wilkerson, and A. M. Jones: School of Sport and Health Sciences, University of Exeter, St. Luke’s Campus, Heavitree Road, Exeter, EX1 2LU, UK.


    FOOTNOTES
 

Address for reprint requests and other correspondence: A. M. Jones, School of Sport and Health Sciences, Univ. of Exeter, St. Luke’s Campus, Heavitree Rd., Exeter, EX1 2LU, UK (e-mail: a.m.jones{at}exeter.ac.uk)

The costs of publication of this article were defrayed in part by the payment of page charges. The article must therefore be hereby marked "advertisement" in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.


    REFERENCES
 TOP
 ABSTRACT
 METHODS
 RESULTS
 DISCUSSION
 ACKNOWLEDGMENTS
 REFERENCES
 

  1. Andersen P and Henriksson J. Capillary supply of the quadriceps femoris muscle of man: adaptive response to exercise. J Physiol 270: 677–690, 1977.[Abstract/Free Full Text]
  2. Bangsbo J, Krustrup P, Gonzalez-Alonso J, Boushel R, and Saltin B. Muscle oxygen kinetics at onset of intense dynamic exercise in humans. Am J Physiol Regul Integr Comp Physiol 279: R899–R906, 2000.[Abstract/Free Full Text]
  3. Barstow TJ and Molé P. Linear and nonlinear characteristics of oxygen uptake kinetics during heavy exercise. J Appl Physiol 71: 2099–2106, 1991.[Abstract/Free Full Text]
  4. Bassett DR and Howley ET. Limiting factors for maximum oxygen uptake and determinants of endurance performance. Med Sci Sports Exerc 32: 70–84, 2000.[Web of Science][Medline]
  5. Beaver WL, Wasserman K, and Whipp BJ. On-line computer analysis and breath-by-breath graphical display of exercise function tests. J Appl Physiol 34: 128–132, 1973.[Free Full Text]
  6. Beaver WL, Wasserman K, and Whipp BJ. A new method for detecting anaerobic threshold by gas exchange. J Appl Physiol 60: 2020–2027, 1986.[Abstract/Free Full Text]
  7. Burgomaster KA, Hughes SC, Heigenhauser GJ, Bradwell SN, and Gibala MJ. Six sessions of sprint interval training increases muscle oxidative potential and cycle endurance capacity in humans. J Appl Physiol 98: 1985–1990, 2005.[Abstract/Free Full Text]
  8. Burnley M, Doust JH, Ball D, and Jones AM. Effects of prior heavy exercise on VO2 kinetics during heavy exercise are related to changes in muscle activity. J Appl Physiol 93: 167–174, 2002.[Abstract/Free Full Text]
  9. Burnley M, Roberts CL, Thatcher R, Doust JH, and Jones AM. Influence of blood donation on O2 uptake on-kinetics, peak O2 uptake, and time to exhaustion during severe-intensity cycle exercise in humans. Exp Physiol 91: 499–509, 2006.[Abstract/Free Full Text]
  10. Calbet JAL, Radegran G, Boushel R, Sondergaard H, Saltin B, and Wagner PD. Plasma volume expansion does not increase maximal cardiac output or VO2max in lowlanders acclimatized to altitude. Am J Physiol Heart Circ Physiol 287: H1214–H1224, 2004.[Abstract/Free Full Text]
  11. Connes P, Perrey S, Varray A, Prefat C, and Caillaud C. Faster oxygen uptake kinetics at the onset of submaximal cycling exercise following 4 wk recombinant human erythropoietin (r-HuEPO) treatment. Pflügers Arch 447: 231–238, 2003.[CrossRef][Web of Science][Medline]
  12. Convertino AV. Blood volume: its adaptation to endurance training. Med Sci Sports Exerc 23: 1338–1348, 1991.[Medline]
  13. Convertino VA. Heart rate and sweat rate responses associated with exercise-induced hypervolemia. Med Sci Sports Exerc 15: 77–82, 1983.[Web of Science][Medline]
  14. Convertino VA, Brock PJ, Keil LC, Bernauer EM, and Greenleaf JE. Exercise training-induced hypervolemia: role of plasma albumin, renin, and vasopressin. J Appl Physiol 48: 665–669, 1980.[Abstract/Free Full Text]
  15. Coyle EF, Hemmert MK, and Coggan AR. Effects of detraining on cardiovascular responses to exercise: role of blood volume. J Appl Physiol 60: 95–99, 1986.[Abstract/Free Full Text]
  16. Coyle EF, Hopper MK, and Coggan AR. Maximal oxygen uptake relative to plasma volume expansion. Int J Sports Med 11: 116–119, 1990.[Web of Science][Medline]
  17. Dill DB and Costill DL. Calculation of percentage changes in volumes of blood, plasma, and red cells in dehydration. J Appl Physiol 37: 247–248, 1974.[Free Full Text]
  18. Ekblom B, Wilson G, and Astrand PO. Central circulation during exercise after venesection and reinfusion of red blood cells. J Appl Physiol 40: 379–383, 1976.[Abstract/Free Full Text]
  19. Engelen M, Porszasz J, Riley M, Wasserman K, Maehara K, and Barstow TJ. Effects of hypoxic hypoxia on O2 uptake and heart rate kinetics during heavy exercise. J Appl Physiol 81: 2500–2508, 1996.[Abstract/Free Full Text]
  20. Fukuoka Y, Grassi B, Conti M, Guiducci D, Sutti M, Marconi C, and Cerretelli P. Early effects of exercise training on on- and off-kinetics in 50-year-old subjects. Pflügers Arch 443: 690–697, 2002.[CrossRef][Web of Science][Medline]
  21. Gledhill N, Warburton D, and Jamnik V. Haemoglobin, blood volume, cardiac function, and aerobic power. Can J Appl Physiol 24: 54–65, 1999.[Web of Science][Medline]
  22. Gonzalez-Alonso J and Calbet JA. Reductions in systemic and skeletal muscle blood flow and oxygen delivery limit maximal aerobic capacity in humans. Circulation 107: 824–830, 2003.[Abstract/Free Full Text]
  23. Grassi B, Poole DC, Richardson RS, Knight DR, Erickson BK, and Wagner PD. Muscle O2 uptake kinetics in humans: implications for metabolic control. J Appl Physiol 80: 988–998, 1996.[Abstract/Free Full Text]
  24. Green HJ, Hughson RL, Thomson JA, and Sharratt MT. Supramaximal exercise after training-induced hypervolemia. I. Gas exchange and acid-base balance. J Appl Physiol 62: 1944–1953, 1987.[Abstract/Free Full Text]
  25. Green HJ, Jones LL, Hughson RL, Painter DC, and Farrance BW. Training-induced hypervolemia: lack of an effect on oxygen utilization during exercise. Med Sci Sports Exerc 19: 202–206, 1987.[Web of Science][Medline]
  26. Green HJ, Jones S, Ball-Burnett ME, Smith D, Livesey J, and Farrance BW. Early muscular and metabolic adaptations to prolonged exercise training in humans. J Appl Physiol 70: 2032–2038, 1991.[Abstract/Free Full Text]
  27. Green HJ, Jones LL, and Painter DC. Effects of short-term training on cardiac function during prolonged exercise. Med Sci Sports Exerc 22: 488–493, 1990.[Web of Science][Medline]
  28. Harms CA, Babcock MA, McClaran SR, Pegelow DF, Nickele GA, Nelson WB, and Dempsey JA. Respiratory muscle work compromises leg blood flow during maximal exercise. J Appl Physiol 82: 1573–1582, 1997.[Abstract/Free Full Text]
  29. Harms CA, Wetter TJ, McLaran SR, Pegelow DF, Nickele GA, Nelson WB, Hanson P, and Dempsey JA. Effects of respiratory muscle work on cardiac output and its distribution during maximal exercise. J Appl Physiol 85: 609–618.
  30. Hopper MK, Coggan AR, and Coyle EF. Exercise stroke volume relative to plasma-volume expansion. Med Sci Sports Exerc 64: 404–408, 1988.
  31. Horwitz LD and Lindenfeld J. Effects of enhanced ventricular filling on cardiac pump performance in exercising dogs. J Appl Physiol 59: 1886–1890, 1985.[Abstract/Free Full Text]
  32. Hughson RL. Regulation of VO2 on-kinetics by O2 delivery. In: Oxygen Uptake Kinetics in Sport, Health and Medicine, edited by Jones AM and Poole DC. London: Routledge, p. 185–211, 2005.
  33. Hughson RL, Cochrane JE, and Butler GC. Faster O2 uptake kinetics at onset of supine exercise with than without lower body negative pressure. J Appl Physiol 75: 1962–1967, 1993.[Abstract/Free Full Text]
  34. Hughson RL and Kowalchuk JM. Kinetics of oxygen uptake for submaximal exercise in hyperoxia, normoxia, and hypoxia. Can J Appl Physiol 20: 198–210, 1995.[Web of Science][Medline]
  35. Hughson RL and Smyth GA. Slower adaptation of VO2 to steady state of submaximal exercise with beta-blockade. Eur J Appl Physiol 52: 107–110, 1983.
  36. Jensen L, Bangsbo J, and Hellsten Y. Effect of high intensity training on capillarization and presence of angiogenic factors in human skeletal muscle. J Physiol 557: 571–582, 2004.[Abstract/Free Full Text]
  37. Jones AM and Poole DC. Oxygen uptake dynamics: from muscle to mouth—an introduction to the symposium. Med Sci Sports Exerc 37: 1542–1550, 2005.
  38. Kanstrup IL and Ekblom B. Acute hypervolemia, cardiac performance, and aerobic power during exercise. J Appl Physiol 52: 1186–1191, 1982.[Abstract/Free Full Text]
  39. Kanstrup IL and Ekblom B. Blood volume and hemoglobin concentration as determinants of maximal aerobic power. Med Sci Sports Exerc 16: 256–262, 1984.[Web of Science][Medline]
  40. Kanstrup IL, Marving J, and Hoilund-Carlsen PF. Acute plasma expansion: left ventricular hemodynamics and endocrine function during exercise. J Appl Physiol 73: 1791–1796, 1992.[Abstract/Free Full Text]
  41. Koga S, Shiojiri T, Shibasaki M, Kondo N, Fukuba Y, and Barstow TJ. Kinetics of oxygen uptake during supine and upright heavy exercise. J Appl Physiol 87: 253–260, 1999.[Abstract/Free Full Text]
  42. Krip B, Gledhill N, Jamnik V, and Warburton D. Effect of alterations in blood volume on cardiac function during maximal exercise. Med Sci Sports Exerc 29: 1469–1476, 1997.[Web of Science][Medline]
  43. Luetkemeier MJ and Thomas EL. Hypervolemia and cycling time trial performance. Med Sci Sports Exerc 26: 503–509, 1994.[Web of Science][Medline]
  44. MacDonald MJ, Shoemaker JK, Tschakovsky ME, and Hughson RL. Alveolar oxygen uptake and femoral artery blood flow dynamics in upright and supine leg exercise in humans. J Appl Physiol 85: 1622–1628, 1998.[Abstract/Free Full Text]
  45. MacDonald MJ, Tarnopolsky MA, and Hughson RL. Effect of hyperoxia and hypoxia on leg blood flow and pulmonary and leg oxygen uptake at the onset of kicking exercise. Can J Physiol Pharmacol 78: 67–74, 2000.[CrossRef][Web of Science][Medline]
  46. Mier CM, Domenick MA, Turner NS, and Wilmore JH. Changes in stroke volume and maximal aerobic capacity with increased blood volume in men and women. J Appl Physiol 80: 1180–1186, 1996.[Abstract/Free Full Text]
  47. Phillips SM, Green HJ, MacDonald MJ, and Hughson RL. Progressive effect of endurance training on VO2 kinetics at the onset of submaximal exercise. J Appl Physiol 79: 1914–1920, 1995.[Abstract/Free Full Text]
  48. Poole DC, Barstow TJ, Gaesser GA, Willis WT, and Whipp BJ. VO2 slow component: physiological and functional significance. Med Sci Sports Exerc 26: 1354–1358, 1994.[Web of Science][Medline]
  49. Poole DC, Ward SA, Gardner GW, and Whipp BJ. Metabolic and respiratory profile of the upper limit for prolonged exercise in man. Ergonomics 31: 1265–1279, 1988.[Medline]
  50. Rossiter HB, Kowalchuk JM, and Whipp BJ. A test to establish maximum O2 uptake despite no plateau in the O2 uptake response to ramp incremental exercise. J Appl Physiol 100: 764–770, 2006.[Abstract/Free Full Text]
  51. Rossiter HB, Ward SA, Howe FA, Kowalchuk JM, Griffiths JR, and Whipp BJ. Dynamics of intramuscular 31P-MRS Pi peak splitting and the slow components of PCr and O2 uptake during exercise. J Appl Physiol 93: 2059–2069, 2002.[Abstract/Free Full Text]
  52. Rowell LB. Human cardiovascular adjustments to exercise and thermal stress. Physiol Rev 54: 75–159, 1974.[Free Full Text]
  53. Sarelius IH. Microcirculation in striated muscle after acute reduction in systemic hematocrit. Respir Physiol 78: 7–17, 1989.[CrossRef][Web of Science][Medline]
  54. Schaffartzik W, Barton ED, Poole DC, Tsukimoto K, Hogan MC, Bebout DE, and Wagner PD. Effect of reduced haemoglobin concentration on leg oxygen uptake during maximal exercise in humans. J Appl Physiol 75: 491–498, 1993.[Abstract/Free Full Text]
  55. Spriet LL, Gledhill N, Froese AB, and Wilkes DL. Effect of graded erythrocythemia on cardiovascular and metabolic responses to exercise. J Appl Physiol 61: 1942–1948, 1986.[Abstract/Free Full Text]
  56. Tordi N, Perrey S, Harvey A, and Hughson RL. Oxygen uptake kinetics during two bouts of heavy cycling separated by fatiguing sprint exercise in humans. J Appl Physiol 94: 533–541, 2003.[Abstract/Free Full Text]
  57. Warburton DE, Gledhill N, Jamnik V, Krip B, and Card N. Induced hypervolemia, cardiac function, VO2max, and performance of elite cyclists. Med Sci Sports Exerc 31: 800–808, 1999.[Web of Science][Medline]
  58. Whipp BJ, Davis JA, Torres F, and Wasserman K. A test to determine parameters of aerobic function during exercise. J Appl Physiol 50: 217–221, 1981.[Abstract/Free Full Text]
  59. Whipp BJ, Rossiter HB, and Ward SA. Exertional oxygen uptake kinetics: a stamen of stamina? Biochem Soc Trans 30: 237–247, 2002.[CrossRef][Web of Science][Medline]
  60. Whipp BJ and Wasserman K. Oxygen uptake kinetics for various intensities of constant-load work. J Appl Physiol 33: 351–356, 1972.[Free Full Text]
  61. Wilkerson DP, Berger NJ, and Jones AM. Influence of hyperoxia on pulmonary O2 uptake kinetics following the onset of exercise in humans. Respir Physiol Neurobiol. In press.
  62. Wilkerson DP, Rittweger J, Berger NJ, Naish PF, and Jones AM. Influence of recombinant human erythropoietin treatment on pulmonary O2 uptake kinetics during exercise in humans. J Physiol 568: 639–652, 2005.[Abstract/Free Full Text]
  63. Williamson JW, Raven PB, and Whipp BJ. Unaltered oxygen uptake kinetics at exercise onset with lower-body positive pressure in humans. Exp Physiol 81: 695–705, 1996.[Abstract]
  64. Yoshida T, Udo M, Ohmori T, Matsumoto Y, Uramoto T, and Yamamoto K. Day-to-day changes in oxygen uptake kinetics at the onset of exercise during strenuous endurance training. Eur J Appl Physiol 64: 78–83, 1992.[CrossRef][Web of Science]



This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
S. T. Sims, N. J. Rehrer, M. L. Bell, and J. D. Cotter
Preexercise sodium loading aids fluid balance and endurance for women exercising in the heat
J Appl Physiol, August 1, 2007; 103(2): 534 - 541.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
G. S. Zavorsky
Plasma volume expansion does not influence oxygen uptake kinetics in trained cyclists
J Appl Physiol, February 1, 2007; 102(2): 828 - 828.
[Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
A. M. Jones, N. J. Berger, D. P. Wilkerson, and I. T. Campbell
Reply to Zavorsky
J Appl Physiol, February 1, 2007; 102(2): 829 - 829.
[Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF) Free
Right arrow All Versions of this Article:
101/3/707    most recent
00154.2006v1
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (6)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Berger, N. J. A.
Right arrow Articles by Jones, A. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Berger, N. J. A.
Right arrow Articles by Jones, A. M.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online
Copyright © 2006 by the American Physiological Society.