Department of Medicine, University of California, San Diego, La Jolla, California
Submitted 8 November 2005 ; accepted in final form 29 March 2006
| ABSTRACT |
|---|
|
|
|---|
12%) in extended µG, but inhomogeneity in the lung was not different compared with short-duration exposure to µG. The results show that VC is essentially unchanged and respiratory muscle strength is maintained during extended exposure to µG, and metabolic rate is reduced. muscle atrophy; spaceflight; humans
However, there are few reports of vital capacity (VC), which can be thought of a surrogate measure of respiratory muscle strength, measured in long-duration microgravity (µG). The earliest measurements during the Skylab flights in the 1970s showed an
10% reduction in VC during an 84-day exposure to µG (39). However, on the basis of ground studies the observed reduction in VC may be attributable to the atmosphere in Skylab, which was hypobaric with an increased O2 fraction (38).
In contrast to Skylab, Spacelab, the Russian Mir space station, and the International Space Station (ISS) operated or operate with a normobaric 21% O2-balance N2 atmosphere. Baranov et al. (4) reported a reduction in postflight forced vital capacity (FVC) of between 5 and 25%, with an apparent increase in the magnitude of the effect as flight durations increased over the range of 7366 days. There were concomitant reductions in peak flow and other indexes of forced expiration. A study of two cosmonauts who lived on Mir for 180 days showed a reduction in VC (
31%) 1 day after return, primarily because of a reduction in both expiratory reserve volume and inspiratory capacity (43). Measurements made
10 days after return showed a persisting reduction in VC. These reductions were attributed to a marked weakening of the respiratory muscles during flight. However, it should be noted that in-flight measurements made in these two subjects 9 days and 175 days into flight were not significantly different from those measured supine preflight, although they were lower than those measured seated preflight.
Pulmonary ventilation has been shown to be largely unaltered by exposure to µG for 12 wk, with only a small reduction in tidal volume and a compensatory increase in breathing frequency, likely as a result of an altered mechanical configuration of the chest wall and abdomen in µG (33). There were only small changes in O2 uptake (
O2), CO2 output (
CO2), and end-tidal PO2 and PCO2. The matching of ventilation to perfusion has been reported to remain unaltered in long-duration µG (44). However, long-duration bed rest of 113 days showed a reduction VC and diffusing capacity of the lung for CO immediately after bed rest that appeared to persist for up to 2 wk into the recovery period (29). Thus there is some question as to what effect, if any, an extended period in µG might have on pulmonary gas exchange and its determinants.
The present study reports VC, respiratory muscle strength, and pulmonary gas exchange and its determinants in 10 subjects who lived on the ISS for between 4 and 6 mo. In contrast to other studies, we performed extensive in-flight measurements in addition to the preflight and postflight measurements and directly assessed respiratory muscle strength through the use of maximum inspiratory and expiratory pressures (MIP and MEP, respectively). Given the inconsistent nature of previous reports of VC in and after µG exposure, and on the basis of our previous studies of gas exchange in short-duration µG, we hypothesized that VC would be essentially unchanged by sustained exposure to µG, that respiratory muscle strength would be maintained, and that pulmonary gas exchange would be unaltered beyond those changes associated with the initial adaptation to µG.
| METHODS |
|---|
|
|
|---|
We studied 10 subjects (9 male, 1 female) all of whom were long-term residents of the ISS. All subjects were healthy on the basis of physical examination by flight surgeons, had a good level of physical fitness, and had normal pulmonary function as evidenced by preflight pulmonary function tests performed by us. All subjects self-reported as nonsmokers. Average age (at the beginning of flight) was 45 yr (range 3952) and average height was 174 cm (range 164183).
Experiment Timing
Subjects performed a short battery of pulmonary function tests (described in Tests of Pulmonary Function) several times preflight, at approximately monthly intervals throughout their 4- to 6-mo sojourn on the ISS, and multiple times postflight. The first in-flight measurement was typically
1 mo after arrival on the ISS. As a part of the overall study, we also examined the effects of space walk on pulmonary function by taking measurements on the day after space walk. These data are reported elsewhere (35) and were excluded from the present analysis.
Preflight and postflight measurements were performed both in the upright posture (standing) and supine (within
10 min of assuming the supine posture). Preflight measurements were made on four occasions typically in the 4 mo preceding flight, although for some subjects this interval was slightly longer. Subjects underwent extensive training on the maneuvers before the start of data collection to minimize any training effects. All preflight sessions were performed at sea level.
Postflight data were collected wherever possible on the day of landing (R+0) in the supine posture only, and on the after day (R+1) in the upright posture. Not all subjects were able to participate in R+0 testing. Some subjects had testing delayed by
1 day either because of the use of alternative landing sites or because of inability to participate in testing because of vestibular disturbances. With the exception of two subjects who landed at Dryden Flight Research Facility in Edwards, CA (barometric pressure
690 mmHg), all postflight testing was at sea level. Subsequent postflight testing occurred at R+4 or R+5, at R+1013, at
R+45 (6 subjects only), and finally at
R+ mission length.
Equipment
We used the Human Research Facility, Rack-1 equipment in the laboratory of the ISS coupled to a small amount of equipment specific to this experiment. For all tests except forced spirometry, subjects breathed on a flanged mouthpiece assembly consisting of a pulmonary function test filter (Pall type PF-30S), a Fleisch no. 2 pneumotachograph (OEM Medical), and a modified Hans Rudolph sliding valve (type 2810B). Total dead space of the breathing assembly was 125 ml. The pneumotachograph was coupled to a Validyne MP-45 differential pressure transducer (±2 cmH2O) via Viton tubes of
80 cm in length. The box holding the pressure transducer and demodulator had a LED bar-graph meter to provide feedback to the subject for expiratory flow control. For forced spirometry a Fleisch no. 4 pneumotachograph coupled to a 30-cm-long tapered cylinder of volume
150 ml was used as in previous spaceflight studies (18). This was coupled to the same Validyne pressure transducer in place of the Fleisch no. 2 pneumotachograph and was calibrated separately as described below.
For measurement of maximum inspiratory and expiratory pressure, a separate Validyne MP-45 differential pressure transducer (±200 cmH2O) was used with its own demodulator. At a predetermined lung volume (see below), subjects actuated the sliding valve connecting them to a path that was closed except for a small
1-mm-diameter hole
20 mm long, providing a flow resistance of
150 cmH2O·l1·s. This allowed a small air leak, preventing any contribution of the buccal muscles to the maximum expiratory pressure and eliminating glottal closure during the maximum inspiratory pressure test (9). Pressure was measured as the average over a 1-s period (2, 12).
Gas concentration was measured at the distal end of the pneumotachograph, proximal to the sliding valve (
98 ml from the mouth), by a quadrupole mass spectrometer specially built for spaceflight (GASMAP, Marquette, Milwaukee, WI). The mass spectrometer sampled gas at 60 ml/min and had a dynamic response (1090%) of
100 ms, which was sufficiently fast so that no dynamic response correction was required for these resting studies (5). In addition, subjects were instrumented with a three-lead ECG using a battery powered amplifier [National Aeronautics and Space Administration (NASA)], which approximated a lead II configuration providing heart rate (HR).
All signals were sampled by the GASMAP by use of a 12-bit analog-to-digital converter at 100 Hz, and the data were stored on a personal computer (IBM ThinkPad 760XD) using specially written software. This software also provided real-time prompting of subject actions and data display. Data were transmitted to the ground for monitoring in real time and in batch mode at the completion of the experimental day for subsequent analysis.
Calibration was performed at the beginning and end of each day by having the GASMAP sample three gas mixtures of known composition. Flow was calibrated by integration of strokes from a 3-liter calibration syringe (Hans Rudolph model 5530) separately for each pneumotachograph. The calibration strategy allowed for separate calibration factors for inspiratory and expiratory flow. GASMAP transit time was determined by the measured delay between the flow resulting from a sharp puff of CO2-containing gas into the pneumotachograph and the 50% point in the subsequent rise of the CO2 signal (5), and this delay was accounted for in subsequent analyses.
Tests of Pulmonary Function
Because of the limited experimental facilities on board the ISS at the time of this study, we were unable to perform any pulmonary function tests that required the use of specialized gas mixtures. Thus all tests performed used only cabin air. In all cases subjects were extensively trained in the maneuvers, coached through them numerous times in the preflight period, provided with graphical feedback of data to permit data quality assessment (supplemented with extensive online help), and encouraged to reject and repeat maneuvers not meeting predefined standards for data quality. At times throughout the flight, the investigators on the ground provided feedback on the quality of the data.
Forced spirometry. Subjects performed a FVC expiration with effort maintained for a minimum of 8 s, followed immediately by a FVC inspiration. At least three blows judged to be "good" by the subject (on the basis of reproducibility of the tracings) were recorded in each session. Data were analyzed as in previous spaceflight studies (18) and met American Thoracic Society requirements for the performance of spirometry (1, 3).
Slow VC. This was determined either from a controlled exhalation from total lung capacity (TLC) to residual volume (RV) at a flow rate of 0.5 l/s or from a short period of resting breathing followed by an inhalation to TLC and subsequent exhalation to RV in an uncontrolled (but not forced) manner. There were no differences in the value of VC from individual tests, and so the data from both maneuvers were used in reporting the VC. The volume was converted to BTPS conditions.
MIP and MEP.
Subjects performed maximal inhalation and exhalation efforts against the occluded valve position (see above) twice within each experimental session. In a single sequence lasting
90 s, subjects breathed quietly for
15 s and then went to a predetermined lung volume and performed a MIP or MEP maneuver against the closed valve for a maximum of 5 s. The process was repeated to cover each lung volume-pressure combination. In all cases the order was MIP at functional residual capacity (FRC), MIP at RV, MEP at FRC, MEP at TLC.
Intrabreath inequality of ventilation-perfusion ratio.
The intrabreath ventilation-perfusion (
A/
) technique (iV/Q) allows calculation of the degree of
A/
inequality from a single, controlled VC expiration. This concept, originally used by West and associates (45), has been shown to reflect the degree of
A/
inequality determined using the multiple inert-gas elimination technique in dogs exposed to methacholine challenge (37). It has also been used to examine
A/
inequality in both divers (13) and astronauts (33).
The technique is fully described in prior publications (22, 37). Briefly, the subject breathed quietly for
60 s allowing the determination of the resting
O2 and
CO2.
O2 and
CO2 were calculated by the N2 balance method (6), and expired ventilation, tidal volume, breathing frequency, and other variables were calculated as the average over the
60-s period of quiet breathing. The subject then inhaled to TLC and without delay exhaled to RV at a controlled flow rate of 0.5 l/s while watching the flowmeter on the pressure transducer box. In subsequent analysis the instantaneous respiratory exchange ratio (intrabreath-R) was calculated and expressed as function of expired volume. This was then compared with calculated values of the intrabreath-R that result from a computerized model of gas exchange in a homogeneous lung with the same
O2,
CO2, and lung volume history as the subject. The resultant value of
A/
(iV/Q) over the course of the expiration was then calculated by interpolation between adjacent intrabreath-R isopleths, each with differing values for
(and thus for
A/
). A prior study has shown that the most sensitive indication of
A/
inequality using this technique is the slope of iV/Q as a function of exhaled volume over the first half of the expiration (37). This and other indicators of
A/
inequality (33) were calculated from the iV/Q-vs.-exhaled volume plot.
Distribution of pulmonary perfusion.
We used the hyperventilationbreath-hold maneuver previously employed in studies of pulmonary perfusion in µG (27, 36). In brief, the subject vigorously hyperventilated for 20 s, reducing PCO2 in all areas of the lung to
20 Torr. The subject then rapidly inhaled to TLC and performed a 15-s breath hold. During the breath hold, CO2 was added to the lung units at a rate proportional to the local blood flow-to-lung volume ratio. Because at TLC regional lung volume is largely uniform (28), the regional PCO2 at the end of the breath hold is a marker of regional pulmonary perfusion. The subject then exhaled at 0.5 l/s, and CO2 concentration was plotted as a function of expired volume. The size of the cardiogenic oscillations and the height of the terminal change in CO2 concentration after the onset of airway closure provide indications of the degree of inhomogeneity of pulmonary perfusion (36).
Statistical Methods
We used the same techniques employed in our previous spaceflight studies. We used a two-way ANOVA (categorical variables were subject and time in µG) in a randomized block design. In cases in which there was a significant F-ratio, post hoc testing using the Bonferroni adjustment was used to test for resulting differences. Significance was accepted at the P < 0.05 level and noted at the P < 0.10 level. To examine any effects of duration of exposure to µG, or reexposure to 1G, upon return we additionally separated in-flight data into early in-flight (within the first 2 mo of flight) and late in-flight (data collected beyond 2 mo in orbit), and early return (data collected within the first 3 days of return) and late return (data collected after the first 3 days of return to 1G).
It should be pointed out that a study such as this with only 10 subjects is inadequately powered to confirm the null hypothesis (i.e., the hypothesis that there is no change in a particular variable). Confirming the null hypothesis with the effect sizes present in much of the data would require subject populations >50, something impractical for a spaceflight experiment. However, in many of the variables that were observed to apparently not change in this study, it could be argued that even if the data reflect an underlying alteration that cannot be confirmed statistically, the magnitude of the change is sufficiently small as to be physiologically insignificant.
| RESULTS |
|---|
|
|
|---|
Table 1 and Fig. 1 show the results for the measurements of VC over the course of the study. As expected, VC was lower supine than standing in 1G as seen previously (19). Postflight VC was not different from that measured preflight in either posture.
|
|
181 ml. There was an early reduction in VC measured in the supine posture postflight, with VC in the early postflight period being
383 ml lower than that measured preflight. This difference was not seen in later postflight measurements and was not observed in the standing posture postflight.
Expiratory reserve volume (ERV) was also obtained from two of the three slow VC maneuvers. ERV measured in µG (1.80 ± 0.06 liter) was the same as that measured in the standing posture in 1G (1.80 ± 0.07 liter), whereas ERV measured supine in 1G was lower by
44% (1.01 ± 0.05 liter). There were no changes in ERV comparing preflight and postflight, and other than a nonsignificant tendency for ERV to be lower later in-flight, no differences between early and late data.
Forced Expiration
FVC [FVC and forced expiratory volume in 1 s (FEV1), Table 1, Fig. 2] showed an essentially similar pattern to that seen in VC, with an early in-flight increase in FVC (by
292 ml) that was absent in the data collected later in flight. The change in FVC was accompanied by essentially parallel changes in other parameters of forced expiration (Fig. 2 and Table 2). Importantly, there was no suggestion of disproportionate changes in FEV1 or midexpiratory flows that might be associated with alterations in airway caliber.
|
|
Maximum Respiratory Pressures
At FRC, MIP in µG was similar to those measured in the upright posture in 1G, or very slightly reduced (Fig. 3A, Table 3). There were no differences in either pressure between measurements made early in flight and those made later in flight. In the postflight period there was an initial reduction in inspiratory pressures measured upright, although this was small (
5 mmHg). Inspiratory pressure increased in the later postflight period compared with those measured immediately postflight. At RV, MIP in µG was not different from that measured supine in 1G, and there were no trends for a change with time (Fig. 3B, Table 3). Postflight there was trend (nonsignificant) for maximum inspiratory pressure to increase.
|
|
6.8 mmHg, compared with upright, to
3.6 mmHg), although the difference remained significant. There were nonsignificant trends for an increase in maximum expiratory pressure in the postflight period. MEP measured at FRC (Fig. 4A, Table 3) showed essentially similar trends, but the changes did not reach the level of significance.
|
Pulmonary ventilation (Table 4) was reduced in µG compared with both preflight standing and supine as a result of a reduction in tidal volume (of
0.1 liter compared with standing). There was a concomitant reduction in alveolar ventilation of
1.1 l/min (
11%) that was accompanied by an increase in end-tidal PCO2 of
2.3 Torr above that seen in the standing posture in 1G but similar to the values in the supine posture both pre- and postflight.
|
O2 and
CO2) was significantly lower in µG by
12% and 16%, respectively, compared with standing in 1G, leaving respiratory exchange ratio unaltered (Fig. 5, Table 4). HR was reduced by 9 beats/min compared with standing in 1G but remained slightly above that in the supine posture. There were trends (nonsignificant) for
O2,
CO2, and HR to fall with longer duration exposure to µG.
|
A/
inhomogeneity that was measured, that is the slope of iV/Q over the first half of phase III, was actually higher in µG than that standing in 1G (Table 4). The range of iV/Q seen over phase III was unaltered compared with standing in 1G, and both were higher in the supine posture. Other markers of inhomogeneity of both
A/
and the distribution of pulmonary perfusion were reduced and did not alter with the time spent in µG. | DISCUSSION |
|---|
|
|
|---|
VC
In contrast to previous studies, we saw little in the way of change in VC either in-flight or postflight. There was in fact a small increase in VC (of
170 ml or
3%) in measurements made in the first 2 mo of exposure to µG, and in measurements made in the subsequent portion of the flight there was no difference compared with standing in 1G (Fig. 1). There were comparable changes in FVC (Fig. 2).
VC has long been used as an indicator (albeit nonspecific) of changes in pulmonary function that might result from environmental stresses. For example, VC has been shown to be increased after ascent from saturation dives (14, 42). Reductions in VC are also considered to be an indicator of the degree of lung damage that results from pulmonary O2 toxicity (10, 11, 25).
In the context of spaceflight, the earliest reports of VC in µG are from the Skylab missions in the 1970s (39), which showed a
10% reduction in the VC measured in subjects exposed to µG for up to 84 days. However, these observations are confounded by the hypobaric, O2-enriched atmosphere in the Skylab vehicle which was a 70% O2-balance N2 atmosphere at an absolute pressure of 258 mmHg. Although the atmosphere was slightly hyperoxic (measured inspired PO2 of
170 Torr), it seems unlikely that this was sufficient to have resulted in pulmonary O2 toxicity, which is known to reduce VC (10, 11, 25). However, the high fractional concentration of O2 in the Skylab atmosphere may have compromised alveolar stability, as areas of high
A/
will rapidly absorb O2 and have their regional lung volume greatly reduced because of the lack of the normally present insoluble inert gas component present in air (78% N2) (15, 31, 32). This, combined with airway closure that still occurs in µG (23), could have contributed to the reduction in VC seen in Skylab (39). This conjecture is supported by the results from ground studies performed before the Skylab flights, which showed a
5% reduction in VC in subjects exposed to 56 days of a comparable atmosphere (68% O2, balance He, total pressure 258 mmHg) (38).
In short-duration spaceflight (up to
2 wk) in Spacelab (a normoxic, normobaric environment), we showed that VC was essentially unchanged compared with that measured with subjects standing on the ground (19). There was an initial decrease in VC seen after
24 h of exposure to µG, attributed to the translocation of blood into the thorax, but subsequent measurements were indistinguishable from those made standing in 1G in the preflight period.
There are only limited reports available from long-duration flight aboard the Russian Mir, a vehicle with a normoxic, normobaric atmosphere. Baranov et al. (4) reported a reduction in VC of up to
20% in postflight measurements, with the magnitude of the effect being dependent on the duration of µG exposure (up to
1 year). Venturoli et al. (43) made very limited in-flight measurements of 2 subjects aboard Mir for 180 days in 1995. In-flight measurements were made on days 9 and 175 of flight and showed a small
5% reduction in VC compared with sitting in 1G. However, in measurements performed 1 day after return to 1G, VC was reduced by
31% both in the sitting and supine postures. Repeat measurements on days 1012 after return to 1G remained reduced (by
15%) and remained so by
6% up to 120 days after return to 1G. These reductions were attributed to a reduction in respiratory muscle strength, although no explanation was given for the maintenance of VC during flight in the face of such an abrupt decline immediately postflight.
Postflight we saw almost no difference in VC compared with preflight, in sharp contrast to previous studies (4, 43). In the standing posture, VC was unaltered in either the early- or late-postflight periods compared with that measured preflight (Table 1, Fig. 1). However, in the supine posture, VC in the early postflight periods was reduced compared with that measured preflight and that measured in the late-postflight period. However, in marked contrast to other studies (4, 43), this reduction was very much smaller (
572 ml or
11%) than the large reductions they reported [31% in the case of Venturoli et al. (43)]. In particular, there was no apparent change in VC comparing the first day of measurement in the postflight period with any other postflight day. In the implementation of our study, we were only able to measure VC in the supine posture on R+0 (the day of landing) and then only in a subset of the subjects, either because subjects were unavailable because of landing at alternative sites or because some subjects were too unwell to participate in testing because of vestibular disturbances. In some cases these may have limited subject effort in the early postflight data. Furthermore, it was apparent that all subjects tested on R+0 were tired and it is not clear that maximal effort VC maneuvers were achieved. We therefore consider the reduction of VC in the supine posture in the immediate postflight period to be of little physiological significance (and in fact it may be spurious).
The results from forced spirometry support this conjecture. We saw no change in FVC, FEV1, or midexpiratory flows comparing postflight and preflight data (Tables 1 and 2, Fig. 2). Similarly, inspiratory flows (changes that depend almost exclusively on muscle performance and effort, as opposed to changes in expiratory flow limitation) were unchanged by long-duration exposure to µG.
Respiratory Muscle Strength
Taken overall, long-duration exposure to µG did not appear to alter respiratory muscle strength to any significant degree. Although MIP and MEP measured in µG generally differed from those measured preflight, there are reasons why this might be expected. But, importantly, there were no cases in which either MIP or MEP at any lung volume was altered between the early-in-flight and late-in-flight measurement periods (Table 3 and Figs. 34). Had µG resulted in a progressive reduction in respiratory muscle strength, we would have expected to see reductions in MIP or MEP as the exposure time increased.
From postural studies and studies in µG (7, 8, 17, 20), gravity is known to influence the configuration of the chest wall, particularly that of the abdominal compartment, and static lung volumes. Although ERV in-flight was not different from that measured standing in 1G, the lack of gravity decreases FRC and RV (19) and makes the abdominal contents and the diaphragm dome move cranially. These alterations are expected to impact on both MIP and MEP. The test sequence we used did not include a direct measurement of FRC as this was not possible in-flight because of the lack of compressed breathing gas mixtures; in addition, changes in chest wall configuration were not measured.
In the absence of such measures, interpretation of differences in MIP and MEP between preflight and in-flight (Table 3, Figs. 34) is speculative at best. In 1G, MIP (and to a lesser extent MEP) were lower in the supine posture than standing. This reduction, which is consistent with previous studies (26), has been attributed to suboptimal activation, recruitment, and coordination of the diaphragm and nondiaphragmatic muscles. This mechanism may contribute to the lower values of MIP and MEP at FRC and to the lower values of MIP at RV, in-flight compared with 1G standing. At TLC, MEP (Table 3, Fig. 4) was reduced in µG compared with both standing and supine in 1G. In this case, the lack of any stable platform against which to push may have limited MEP. In this context it is notable that late-in-flight measurements showed a trend toward being higher, perhaps because subjects became more adept at the maneuver as time in µG progressed.
Postflight there were trends (at times significant) for an increase in both MIP and MEP. For the most part this was not solely a result of an early-postflight reduction in maximum pressure generation but a subsequent increase to above that measured preflight. The cause of these increases is unknown; however, we speculate that this may be a reflection of the postflight rehabilitation measures applied to long-duration space travelers, which include numerous strength training exercises that might affect the abdominal muscles.
Numerous studies have shown a marked reduction in the performance of the weight-bearing muscles with impaired force generation and significant atrophy (21, 30). However, this atrophy appears to be due to a lack of activity in the antigravity muscles in µG (the "use it or lose it" model) as opposed to a systemic effect on skeletal muscles per se. Although some respiratory muscles have important postural and antigravity functions (16), the lack of change of respiratory muscle strength seen in these studies suggests that the absence of gravity does not contribute greatly to disuse atrophy in these muscles.
Pulmonary Gas Exchange
The most striking and unexpected observation was that overall there was a decrease in metabolic rate (as evidenced by pulmonary gas exchange) in µG and a trend (not significant) for a reduced
O2 later in flight compared with that measured earlier (Table 4, Fig. 5). This result is in contrast to earlier observations made in short-duration spaceflight (12 wk) (33), which showed no change in
O2 or
CO2 compared with that measured standing in 1G. Whether this difference is a result of a higher level of activity in busy, short-duration flights, when the timeline is hectic, or part of the possible trend to a lower metabolic rate as time spent in µG increased is unclear. It may also be that a reduction in body mass contributed to a reduction in metabolic rate. On average our subjects lost
3% of their body mass over the duration of the flight; however, the reduction in
O2 was much greater than this (
12%), which, coupled with the fact that postflight
O2 was not reduced, somewhat argues against this as the primary cause. Notably, the O2 pulse (
O2/HR) was unaltered by µG exposure.
Studies in short-duration spaceflight (up to 16 days) and bed rest of 16 days show a slight reduction in energy expenditure (41), although these reductions were smaller than the reductions we saw in
O2 in this study. Importantly, however, athletes have a higher resting metabolic rate than sedentary subjects, even when adjusted for fat-free body mass (40). Thus the reduction in resting
O2 (which might be considered as a surrogate for resting metabolic rate) in long-duration spaceflight might be reflective of a detraining effect during flight of subjects that had a moderately high level of physical activity preflight.
It is likely that the reduced ventilation seen in µG is at least in part a reflection of the reduction in metabolic demand. However, as was the case in short-duration flight, end-tidal PCO2 was elevated in µG (in this case by
2.3 Torr), suggesting a similar change in the set point of the CO2 control system despite the fact that µG does not seem to alter CO2 response (34).
The distribution of
A/
seen in the lung in µG matched that seen in short-duration flight (Table 4). The range of iV/Q over phase III of a prolonged expiration was virtually identical to that reported before (33) and not different from that seen standing in 1G. This reinforces the previous conclusion drawn from spaceflight studies, namely that, over the range of normal breathing, the major determinant of
A/
inhomogeneity is not gravitational in origin. The iV/Q slope seen over the first half of phase III [the most sensitive indicator of
A/
inhomogeneity from this test (37)] was slightly elevated in µG compared with standing in 1G, lending credence to previous speculation (33) that gravity in fact provides a degree of matching between ventilation and perfusion in the normal upright human lung. The result is also consistent with a previous study in two subjects aboard Mir for
6 mo, which showed that the matching of ventilation to perfusion was unaltered by the time spent in µG (44).
As was the case with the inhomogeneity of
A/
, the distribution of pulmonary perfusion almost exactly matches that seen in short-duration spaceflight (Table 4) (36). There is a clear influence of gravity on pulmonary perfusion that does not change as time in µG is prolonged. This result is consistent with a strictly mechanical mechanism dominating the distribution of pulmonary perfusion (e.g., the zone 1, 2, 3 model) as opposed to an active control mechanism.
In conclusion, the results of this study show clearly that VC, respiratory muscle strength, and most indexes of pulmonary gas exchange do not suffer physiologically significant degradation when subjects are placed in sustained µG. Our findings are important in the context of future spaceflight missions that may well involve very long exposure to µG (e.g., on a mission to Mars). They show clearly that long-duration exposure to µG per se does not detrimentally affect the mechanical aspects of lung function, at least in terms of VC and respiratory muscle strength, and does not result in an impairment of pulmonary gas exchange, although there appears to be a reduction in metabolic rate. Taken in the context of previous studies on Skylab (39), the results suggest that, provided that a normoxic, normobaric environment is maintained, it is reasonable to expect no significant degradation in these most basic measures of pulmonary function in long-duration µG.
| GRANTS |
|---|
|
|
|---|
| ACKNOWLEDGMENTS |
|---|
|
|
|---|
| FOOTNOTES |
|---|
The costs of publication of this article were defrayed in part by the payment of page charges. The article must therefore be hereby marked "advertisement" in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.
| REFERENCES |
|---|
|
|
|---|
A/
ratios during O2 breathing. J Appl Physiol 38: 886895, 1975.This article has been cited by other articles:
![]() |
R. M. Baevsky, V. M. Baranov, I. I. Funtova, A. Diedrich, A. V. Pashenko, A. G. Chernikova, J. Drescher, J. Jordan, and J. Tank Autonomic cardiovascular and respiratory control during prolonged spaceflights aboard the International Space Station J Appl Physiol, July 1, 2007; 103(1): 156 - 161. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||