|
|
||||||||
INNOVATIVE METHODOLOGY
1The John B. Pierce Laboratory and Department of Cellular and Molecular Physiology, Yale University School of Medicine, New Haven, Connecticut; and 2Department of Pharmacology and Toxicology, Michigan State University, East Lansing, Michigan
Submitted 28 December 2005 ; accepted in final form 1 February 2006
| ABSTRACT |
|---|
|
|
|---|
2 s. Microiontophoresis (1 µm pipette tip; 1 µA, 1 s) of phenylephrine (PE) transiently increased [Ca2+]i by 479 ± 64 nM (n = 8, P < 0.05) with constriction (26 ± 3 µm). Flushing blood from the lumen with saline increased fluorescence at 510 nm by
45% during excitation at both 340 and 380 nm with no difference in resting [Ca2+]i, diameter or respective responses to PE (n = 7). Acetylcholine microiontophoresis (1 µA, 1 s) transiently reduced resting SMC [Ca2+]i by 131 ± 21 nM (n = 6, P < 0.05) with vasodilation (17 ± 1 µm). Superfusion of sodium nitroprusside (10 µM) transiently reduced SMC [Ca2+]i by 124 ± 18 nM (n = 6, P < 0.05), whereas dilation (23 ± 5 µm) was sustained. Resolution of arteriolar SMC [Ca2+]i in vivo discriminates key signaling events that govern the local control of tissue blood flow. calcium photometry; microcirculation; vasomotion
The goal of this study was to evaluate [Ca2+]i dynamics in arteriolar SMC in vivo. For this purpose, we developed methods based on fluorescence microscopy and photometry while preserving the integrity of blood flow control. A ratiometric calcium-sensitive dye (fura PE-3) was utilized to minimize the effect of movement artifacts and changes in vessel wall thickness associated with dilation and constriction (35). To reduce the potential for nonspecific signals while preserving the structural and functional integrity of arteriolar networks, aparenchymal segments were prepared in the epithelial region of the hamster cheek pouch for selective loading of SMC using abluminal perifusion of dye from a micropipette. To evaluate arteriolar SMC reactivity in light of [Ca2+]i dynamics through a spectrum of stimuli, measurements were performed during changes in ambient O2, during spontaneous vasomotion, and in response to agonists that acted either on SMC directly or via endothelium-dependent signaling. To establish the validity of our methods, complementary experiments were performed to evaluate the effects of blood flow within the vessel lumen on fluorescent signals. We tested the hypothesis that the rise and fall of SMC [Ca2+]i underlies arteriolar constriction and dilation in vivo. Although such relationships are implied from in vitro studies, it is essential that they be verified and extended in vivo. Our findings support this hypothesis and demonstrate that the resolution of arteriolar SMC [Ca2+]i in vivo discriminates key signaling events governing the local control of tissue blood flow.
| METHODS |
|---|
|
|
|---|
All procedures were approved by the Institutional Animal Care and Use Committee of The John B. Pierce Laboratory and were performed in accordance with the National Institutes of Health Guide for the Care and Use of Laboratory Animals. Male golden hamsters (90 ± 2 g; n = 18; Charles River Breeding Laboratories, Kingston, NY) were maintained at 24°C on a 14:10-h light-dark cycle and provided rodent chow and water ad libitum. Surgical procedures typically required
3 h and were performed using a stereo microscope. Experimental procedures typically lasted 45 h. At the end of each day's experiments, the hamster was euthanized with an overdose of pentobarbital sodium delivered intravenously.
Surgical Procedures
A hamster was anesthetized with pentobarbital sodium (65 mg/kg, intraperitoneal injection) and tracheotomized to ensure airway patency. The right femoral vein was cannulated for continuous replacement of fluid and maintenance of anesthesia (10 mg pentobarbital/ml in sterile saline infused at 0.41 ml/h). Depth of anesthesia was maintained according to the spontaneous rate of ventilation and lack of withdrawal to toe pinch. Body temperature was maintained at 37°C by using conducted heat.
The hamster was positioned on a custom-fabricated (Technical Services, Pierce Laboratory, New Haven, CT) Plexiglas platform. The left cheek pouch was everted and opened longitudinally, and the epithelial region was pinned flat over an UV-fused silica glass window (25 mm diameter x 2 mm thick; Edmund Scientific, Barrington, NJ) mounted on a pedestal that was integral to the platform. Superficial connective tissue was removed using microdissection. A defined region along second-order arterioles was selected for study on the basis of 1) being located at least 1 cm away from the edge of the preparation, 2) lack of branching for a distance of
500 µm, and 3) absence of adjacent venules. The epithelial tissue was carefully removed to obtain aparenchymal segments (22, 24).
The exposed cheek pouch was superfused continuously (
5 ml/min) with bicarbonate-buffered physiological saline solution (PSS, in mmol/l: 137.0 NaCl, 4.7 KCl, 1.2 MgSO4, 2.0 CaCl2, 18.0 NaHCO3; pH 7.4, 37°C) prepared with deionized water (dH2O) and equilibrated with 5% CO2-95% N2. The effluent solution was aspirated with a vacuum line. Reagents were obtained from Sigma-Aldrich (St. Louis, MO) or J. T. Baker (Phillipsburg, NJ) unless indicated. In some experiments, the superfusate was equilibrated with 10 or 21% O2 (5% CO2-balance N2) to enhance vasomotor tone.
The preparation was secured on the fixed stage of an intravital microscope (E600FN; Nikon) that was mounted on an X-Y translation platform. This configuration enabled all regions of interest to be observed without disturbing the preparation or the placement of micropipettes (described below). Each preparation equilibrated for at least 30 min before experimental procedures were initiated. One arteriole was studied in each preparation. Micropipettes were pulled (P-97, Sutter Instruments; Novato, CA) from borosilicate glass capillaries (OD 1.2 mm, ID 0.69 mm; Warner Instruments; Hamden, CT).
Dye Loading and Calcium Photometry
Aparenchymal segments were perifused with dye solution to load SMC. For each experiment, fura PE-3 (AM) (acetoxymethyl ester, TEF Laboratories; Austin, TX) was mixed with Pluronic-127 (Molecular Probes; Eugene, OR) and diluted in fresh PSS to yield a final dye concentration of 1 µM (with 0.1% pluronic, 0.1% DMSO). Perifusion micropipettes (tip ID
70 µm) were filled with dye solution, secured in a micromanipulator, and positioned with the tip perpendicular and adjacent to the vessel. The fura PE-3 solution was perifused for 20 min at 7 µl/min by use of a syringe pump (sp100i, World Precision Instruments, Sarasota, FL). The segment was then inspected visually at x400 (Nikon Fluo x40/0.8 W objective; used for all experiments) during epi-illumination at 380 nm to ascertain SMC loading, confirmed by the circumferential orientation of labeled cells while focusing along the vertical axis through the arteriolar wall. Labeling that was characteristic of endothelial cells (EC; i.e., axial orientation) was not apparent. At least 30 min were allowed to wash out any remaining free dye.
Arterioles were excited alternately (10 Hz) at 340 and 380 nm by use of a xenon arc lamp, while fura PE-3 emission (510 nm) was recorded with a photomultiplier system (field of view, 100 x 100 µm) interfaced with a personal computer (IonOptix; Milton, MA). The fura PE-3 fluorescence ratio (R) was calculated as the ratio of fluorescence emission during excitation at 340 nm divided by that at 380 nm (27, 35). Signals were corrected for autofluorescence and background fluorescence recorded before dye loading. For simultaneous recordings of internal vessel diameter (resolution,
1 µm), a video micrometer (Microcirculation Research Institute, College Station, TX) was used. Transmitted light was provided by a 100-W halogen lamp with a dichroic mirror (510/40 nm) positioned in front of the video camera (LCL-902C; Watec, Las Vegas, NV), and the image was viewed at a final magnification of x700 on a video monitor (PVM-97; Sony).
To calculate SMC [Ca2+]i, fura PE-3 (10 µM K+ salt; TEF Laboratories) was added to 11 solutions of known free calcium concentration ([Ca2+]) (calcium calibration kit no. 2; Molecular Probes). For each calibration solution, a slide was partitioned by using a thin strip of vacuum grease to record autofluorescence (calibration solution without dye) and fura PE-3 fluorescence. Polystyrene beads (diameter, 45 µm; Polysciences; Warrington, PA) were added to maintain a constant optical path length between slide and coverslip when positioned on the microscope stage. For each experiment, fluorescence ratios were determined at 0 [Ca2+] (Rmin) and at 39 µM [Ca2+] (Rmax), respectively; values were recorded three times and averaged. The constant
was calculated from the fluorescence during excitation at 380 nm with 0 µM [Ca2+] divided by that with 39 µM [Ca2+]. As illustrated in Fig. 1, plotting these data as log {
[(R Rmin)/(Rmax R)]} vs. log [Ca2+] enabled log Kd to be determined as the x-intercept. These experiments (n = 5) yielded the following values for our intravital microscopy system: Rmin = 0.5 ± 0.02, Rmax = 4.1 ± 0.01,
= 4.4 ± 0.01, and Kd 303 ± 8 nM. [Ca2+]i for arteriolar SMC was calculated by using the equation [Ca2+]i nM = Kd x
x (R Rmin)/(Rmax R) (21).
|
Source of [Ca2+]i signal. To minimize the possibility of signals arising from cells other than SMC, epithelial tissue was dissected away to obtain aparenchymal arteriolar segments (22, 24). In preliminary experiments, ionomycin (10 µM) was added to the superfusion solution while the [Ca2+]i signal was recorded to confirm successful loading of fura PE-3 into the aparenchymal segment. Mast cells near the adventitia of cheek pouch arterioles (14) could incorporate dye and thereby affect the [Ca2+]i signal as well as arteriolar reactivity. To test for the presence of mast cells on aparenchymal segments, preparations were stained with toluidine blue (0.1% solution) at the end of experiments.
Vasomotor tone, oxygen sensitivity, and vasomotion.
Key functional indexes of the physiological integrity of arterioles include the level of spontaneous vasomotor tone and sensitivity to changes in superfusate O2 content (22, 24). To test the O2 sensitivity of aparenchymal arteriolar segments in vivo, superfusate oxygen was increased from 0 to 21% for
5 min before and after dye loading to evaluate [Ca2+]i responses during vasoconstriction. The level of spontaneous vasomotor tone was evaluated by adding sodium nitroprusside (SNP, 1 mM) to the superfusate. When vasomotion was present, [Ca2+]i was monitored while cyclic changes in arteriolar diameter were recorded, and no other interventions were performed in these preparations.
Endothelium-dependent vasodilation. Robust vasodilation in response to the endothelium-dependent vasodilator ACh provides another critical index of the functional integrity of arterioles in vivo (2, 4). With EC [Ca2+]i shown to increase upon activation of muscarinic receptors (3, 7, 9, 13, 36), a fall in the [Ca2+]i signal indicates SMC-specific responses. Furthermore, the ability to monitor changes in SMC [Ca2+]i during relaxation (dilation) as well as during contraction (constriction; below) is critical to understanding a full range of [Ca2+]i dynamics during blood flow control.
For these experiments, microiontophoresis was used to deliver ACh (1.0 M in dH2O; 1 µA, 1 s pulse from a 1-µm micropipette tip) locally onto the dye-loaded segment (2, 38), while internal diameter and SMC [Ca2+]i were recorded simultaneously at the site of stimulation. Vehicle controls were performed to determine whether the loading solution affected vasomotor responses. Vessels were stimulated with ACh (as above) before and after the dye-loading protocol with the exception that the solution did not contain fura PE-3.
Optical effects of blood flow.
The presence of red blood cells flowing in the vessel lumen can influence the optical properties of arterioles by scattering and absorbing light. To investigate these effects on recordings of SMC [Ca2+]i dynamics, aparenchymal arteriolar segments were monitored under control conditions and while blood was flushed from the lumen with PSS. Perfusion micropipettes were sharpened (OD 15 µm) by triple beveling using a rotating disk with an abrasive surface of 0.3 µm. The micropipette was filled with PSS containing heparin (10 U/ml; Elkins-Sinn; Cherry Hill, NC), secured in a micromanipulator, and inserted into a side branch located upstream from the aparenchymal segment. A hydrostatic water column connected to the micropipette was elevated until the effluent PSS completely flushed blood from the lumen of the observed arteriolar segment. The height of the column corresponded to pressures (4550 cmH2O) that approximated values recorded in vivo (12). The effluent PSS was directed into the dye-loaded segment by occluding side branches between the perfusion micropipette and the recording site. Local responses to SMC activation via
1-adrenoreceptors with phenylephrine (PE; 0.5 M in dH2O) microiontophoresis (1 µA, 1 s) were obtained under control conditions and during PSS perfusion. For the purpose of comparing responses with and without blood flow, a brief transient stimulus enabled the time course of responses to be observed as well as peak values.
Data Analyses
All data were acquired at 10 Hz. Diameter changes (µm) were calculated as the difference between the peak response and the preceding baseline diameter. Values for SMC [Ca2+]i were calculated on the basis of Rmin, Rmax, and Kd as determined in vitro, and the fluorescence intensities were recorded in vivo. Changes in SMC [Ca2+]i are reported as the difference between the peak response and the preceding baseline. Data were analyzed (SigmaStat v. 3.1, SPSS; Chicago, IL) by Student's paired t-test or the Mann-Whitney rank sum test. Differences were considered statistically significant with P < 0.05. Summary data are presented as means ± SE.
| RESULTS |
|---|
|
|
|---|
= 6.7 ± 0.7. As assessed with toluidine blue, arterioles of similar branch order within intact epithelial regions of the cheek pouch showed numerous perivascular mast cells. In contrast, mast cells were not readily apparent along aparenchymal segments (n = 3).
Vasomotor Tone, Oxygen Sensitivity, and Vasomotion
In preparations evaluated for vasomotor tone, resting diameter was 33 ± 2 µm. Elevating superfusate O2 from 0 to 21% produced constriction (11 ± 2 µm) that was unaffected by dye loading. In these preparations (n = 6), baseline [Ca2+]i was 511 ± 120 nM and increased by 108 ± 53 nM (P < 0.05), recorded 5 min after raising O2 to 21% during a sustained constriction. Superfusion of SNP reduced SMC [Ca2+]i by 124 ± 18 nM (n = 6, P < 0.05) during the first minute as dilation (23 ± 5 µm) ensued. As arterioles reached maximal diameter (48 ± 5 µm), SMC [Ca2+]i recovered to within 57 ± 21 nM of baseline (P > 0.05). Spontaneous vasomotion (34 cycles/min) was observed in four experiments. Representative traces of SMC [Ca2+]i and diameter changes during vasomotion in vivo are shown in Fig. 2. Across these experiments (n = 4), SMC [Ca2+]i changes (150 ± 53 nM) preceded diameter changes (7 ± 1 µm) by
2 s.
|
Acetylcholine dilated arterioles transiently by 17 ± 1 µm and was associated with a transient fall in SMC [Ca2+]i of 131 ± 21 nM (Fig. 3; n = 6, P < 0.05). The amplitude of vasodilation to ACh before dye loading (20 ± 2 µm) was not significantly different. Independent vehicle controls confirmed that there was no effect of the loading solution on vasodilation to ACh (n = 4; data not shown).
|
The resting diameter of aparenchymal arteriolar segments containing blood flow (40 ± 3 µm, n = 8) was not different from that when flushed with PSS (42 ± 3 µm; n = 7). Flushing blood from the arteriolar lumen increased fluorescence (at 510 nm) by
45% during excitation at both 340 and 380 nm (Fig. 4A). Nevertheless, the 340/380 nm ratio from fura PE-3 indicated that baseline SMC [Ca2+]i during blood flow (371 ± 24 nM) was not significantly different from that when the lumen contained PSS (366 ± 29 nM, n = 12; Fig. 4B).
|
|
|
|
| DISCUSSION |
|---|
|
|
|---|
Functional Integrity of Aparenchymal Arterioles
Arteriolar reactivity to changes in superfusate PO2 is sensitive to experimental perturbation and is typically lost once segments are isolated for in vitro study (22, 24). Thus the increase in arteriolar SMC [Ca2+]i during O2-induced constriction supports the physiological nature of responses in vivo while confirming the integrity of aparenchymal arterioles after loading SMC with fura PE-3. In so doing, we present the first data for arteriolar SMC [Ca2+]i responses to changes in PO2.
Consistent with the observed increase in SMC [Ca2+]i during 21% O2 (RESULTS), an integral role for L-type Ca2+ channel activation has been implicated in mediating SMC depolarization and arteriolar constriction in response to elevated PO2 (37). As illustrated in Fig. 2, SMC [Ca2+]i cycled with arteriolar diameter (and tissue blood flow) during spontaneous vasomotion. Nifedipine (an L-type Ca2+ channel antagonist) was found to dilate these arterioles and eliminate vasomotion (1). In turn, the relaxation of arteriolar SMC in response to ACh is associated with hyperpolarization (33, 38, 39). Thus the fall in SMC [Ca2+]i we observed here (Fig. 3) can be explained by closure of L-type Ca2+ channels (23, 28). In response to PE, the rise in SMC [Ca2+]i preceding vasoconstriction (Fig. 5) is consistent with that shown for arteriolar SMC (13, 27, 36, 42) in vitro and can be explained by the activation of L-type [Ca2+]i channels upon depolarization (29, 38).
Collectively, the present data are consistent with the control of arteriolar SMC in vivo through electromechanical coupling (23, 28). Furthermore, the frequency and amplitude of vasomotion are similar to those studied previously with respect to underlying electrophysiological events (1). The delay observed between electrical events and vasomotor responses (
3 s; Ref. 1) is slightly longer than the
2-s lag found here between the rise (and fall) in SMC [Ca2+]i and arteriolar constriction (or dilation). These temporal relationships further indicate that changes in SMC membrane potential govern the open probability of L-type Ca2+ channels to control arteriolar diameter (23). Moreover, as shown for membrane potential of arteriolar SMC in vivo (1), the bidirectional changes in arteriolar SMC [Ca2+]i confirm that such measurements are responsive in both directions.
Selectivity of SMC Labeling and Ca2+ Signaling
In the arterioles studied here, the endothelium is circumscribed by a monolayer of SMC, with respective cell layers readily distinguished according to longitudinal vs. circumferential orientation (26, 32, 38). In vitro studies have shown that respective cell type-specific [Ca2+]i measurements from arterioles are made possible by using acetoxymethyl ester forms of the dye and restricting the loading solution to the luminal or abluminal surface of the vessel wall (13, 20, 27, 42). Thus delivery in the bath targets SMC and luminal perfusion targets EC. A complementary strategy for dye delivery has proven useful in selectively disrupting respective cell layers using photodamage in vitro (19) and in vivo (2, 4, 25).
For intravital studies of arteriolar EC, techniques similar to those used to flush blood from the lumen (see METHODS) have been used to load Ca2+-sensitive dyes (16, 17). Whereas constraining the dye to the luminal compartment minimizes exposure of other cells to the dye solution, restriction of the dye to the SMC is not possible in the intact tissue, because arterioles are typically embedded in the tissue parenchyma. By preparing aparenchymal segments to minimize nonspecific signals, the present study demonstrates selective dye loading of arteriolar SMC in vivo using local perifusion. Visual inspection confirmed that the distribution of fura PE-3 was restricted to circumferentially oriented SMC, as are the [Ca2+]i dynamics.
The [Ca2+]i signals recorded here decreased routinely after an ACh stimulus, as illustrated in Fig. 3 and reported for SMC in isolated vessels with intact EC (3, 13). In contrast, the [Ca2+]i signal originating from EC should increase in response to ACh (3, 7, 9, 13, 36). Nevertheless, EC [Ca2+]i has also been shown to increase during constriction to PE and attributed to Ca2+ diffusion from SMC through myoendothelial gap junctions (13, 42). An alternate although unresolved explanation is that
1-adrenoreceptors expressed on EC elicit a Ca2+ response in the endothelium (10, 36).
Despite compelling evidence for gap junctional coupling between SMC and EC in microvessels isolated for in vitro study (18, 26, 40, 41), myoendothelial coupling has not been manifest during intravital studies of arterioles in vivo, either in the hamster cheek pouch (2, 8, 38) or the mouse cremaster muscle (33). Perhaps the discrete nature of myoendothelial contacts in these microvessels (31) enables local regulation of heterocellular coupling in a manner that can be affected by experimental conditions. In light of the findings presented here, the ability to monitor Ca2+ dynamics from arteriolar SMC as well as EC both in vivo and in vitro should prove insightful with respect to resolving such controversies in light of differences in respective investigative strategies.
Superfusion of SNP, an NO donor acting independent of the endothelium, resulted in a transient decrease in SMC [Ca2+]i that returned toward baseline, despite the persistence of vasodilation. This behavior differs from that reported for small branches of the hamster femoral artery studied in vitro after precontraction with norepinephrine, where dilation occurred independent of changes in SMC [Ca2+]i. Thus, although pharmacomechanical coupling is implied under both conditions, its time course and contribution may vary between vessels as well with experimental conditions. Further evidence for changes in Ca2+ sensitivity of arteriolar SMC comes from in vitro studies, where activation of protein kinase C with indolactam produced vasoconstriction with no change in [Ca2+]i (13, 27). Although signaling events underlying calcium sensitization were not studied here, the present methods should prove useful in investigating these signaling pathways in future studies.
Critique of Methods
Photometry.
Under resting conditions across experiments, the [Ca2+]i reported here for SMC in hamster cheek pouch arterioles (
400 nM) is severalfold higher than that reported for SMC in arterioles isolated from the cremaster of the rat (
55 nM) (27) or hamster (
170 nM) (42). As in vitro measurements tend to overestimate [Ca2+]i (30), this difference is unlikely to be explained by our calibration experiments. It is possible that the level of tone differed or that higher loading with fura 2 may have buffered [Ca2+]i in these former studies. The substantial level of spontaneous vasomotor tone observed here is consistent with Ca2+-dependent activation of contractile proteins in SMC. Furthermore, a resting SMC [Ca2+]i of
400 nM allows for the substantial decrease (
130 nM) during vasodilation with ACh as well as the near-doubling of SMC [Ca2+]i during peak constriction (to lumen closure) in response to PE. Although the application of our in vitro calibrations (see METHODS) to calculations of SMC [Ca2+]i in vivo must be interpreted with caution, the Kd we determined in vitro (303 nM) for this study provides a reproducible reference for our experimental conditions.
Compared to photometry using conventional fluorescence microscopy, confocal imaging can provide greater temporal and spatial resolution of Ca2+ signals (5, 17). However, the shallow depth of field renders the preparation more sensitive to movement as regions of interest can leave the focal plane during vasodilation and vasoconstriction. In contrast, conventional optics affords greater depth of field, thereby capturing more of the fluorescence signal along with a reduction in movement artifact, particularly when cells are loaded with a ratiometric dye. Nevertheless, conventional photometry cannot determine subcellular localization of the signal within responding cells; for example, our sampling window encompassed 100 µm (and multiple SMC) along the arteriole.
In contrast to optically sectioning a microvessel by using confocal imaging (5, 17), photometry with conventional optics acquires light from above and below the focal plane. Thus obtaining cell type-specific responses requires that the indicator be confined to cells of interest. An alternative approach involves discrete sampling of pixel intensities in fluorescent images of the arteriolar wall after luminal or abluminal dye labeling (9). It is possible that abluminal perifusion resulted in dye uptake into EC that was undetectable by eye but sufficient to attenuate the integrated signal detected by the photometer. Nevertheless, the present data illustrate that the use of a ratiometric dye provides an affordable approach to obtaining a robust signal that can resolve SMC [Ca2+]i dynamics in vivo. In turn, such measures provide information for distinguishing between vasomotor responses mediated by electromechanical (i.e., Ca2+-dependent) coupling of contractile proteins vs. those mediated by changes in their Ca2+ sensitivity (34).
Effect of blood.
We used fura PE-3 in the present study as cellular retention of dye and fluorescence signals were found to be brighter and longer lasting than that obtained with either fura 2 or bis-fura in our preliminary studies. With either ratiometric dye, as free [Ca2+]i increases, the fluorescence at 510 nm should increase during excitation at 340 nm and fall during excitation at 380 nm (35). With reference to the robust responses in SMC [Ca2+]i evoked by PE, we investigated how the presence of blood affected respective signals. As shown in Fig. 4, flushing blood from the vessel lumen increased both the 340-nm signal and the 380-nm signal by the same amount (
45%) with no effect on the fura PE-3 ratio. Indeed, Fig. 5 and Table 1 illustrate that, across experiments, neither SMC [Ca2+]i dynamics nor vasoconstriction to PE was affected by whether blood was present in the vessel lumen.
The effect of blood on respective signals is clearly resolved in Fig. 6. In the presence of blood flow, the 380-nm signal initially decreased and then increased above baseline as arterioles constricted, whereas the 340-nm signal increased rapidly at first and then more slowly. In contrast, with blood flushed from the lumen, there was a clear divergence of respective signals as predicted (35). Nevertheless, the fura PE-3 ratio and SMC [Ca2+]i were similar under both conditions, as was the vasomotor response. Thus we attribute the blood "artifact" (which is most apparent in the 380-nm signal) to the progressive emptying of blood from the vessel lumen during constriction with the corresponding elimination of light scattering and absorption by red blood cells. In vitro studies using fura 2 had indicated that a component of both signals can increase as a consequence of constriction presenting a larger tissue volume (i.e., dye content) in the optical sample (27). In accord with the present findings, the 340/380-nm ratio was found to be insensitive to this effect (27). These control experiments substantiate our ability to evaluate SMC [Ca2+]i dynamics in vivo and resolve the effect of blood on the optical properties of fura PE-3.
In conclusion, we present the first recordings of [Ca2+]i dynamics in arteriolar smooth muscle cells during the local control of tissue blood flow using conventional fluorescence microscopy and Ca2+ photometry. Experiments monitored [Ca2+]i responses to stimuli that act directly on SMC (O2, PE, and SNP) or indirectly via the endothelium (ACh). Our findings indicate that aparenchymal arteriolar segments retain functional integrity, including oxygen sensitivity, spontaneous vasomotion, after selective loading of SMC with the calcium-sensitive dye fura PE-3. Although the presence of blood flow in the arteriolar lumen attenuates fluorescence significantly, the ratiometric nature of fura PE-3 enables measurements of SMC [Ca2+]i during spontaneous vasomotion, during vasodilation, and during the activation of SMC. These findings substantiate findings from isolated arterioles by extending them to the living microcirculation. In vivo measurements should prove useful in providing new insight into the regulation of arteriolar SMC [Ca2+]i and in resolving how experimental interventions affect microvascular [Ca2+]i dynamics.
| GRANTS |
|---|
|
|
|---|
| ACKNOWLEDGMENTS |
|---|
|
|
|---|
| FOOTNOTES |
|---|
The costs of publication of this article were defrayed in part by the payment of page charges. The article must therefore be hereby marked "advertisement" in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.
| REFERENCES |
|---|
|
|
|---|
1-adrenoceptor-mediated constriction of arterioles. Am J Physiol Heart Circ Physiol 281: H873H881, 2001.This article has been cited by other articles:
![]() |
Y. N. Tallini, J. F. Brekke, B. Shui, R. Doran, S.-m. Hwang, J. Nakai, G. Salama, S. S. Segal, and M. I. Kotlikoff Propagated Endothelial Ca2+ Waves and Arteriolar Dilation In Vivo: Measurements in Cx40BAC GCaMP2 Transgenic Mice Circ. Res., December 7, 2007; 101(12): 1300 - 1309. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. R. Uhrenholt, T. L. Domeier, and S. S. Segal Propagation of calcium waves along endothelium of hamster feed arteries Am J Physiol Heart Circ Physiol, March 1, 2007; 292(3): H1634 - H1640. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Earley and M. T. Nelson Central role of Ca2+-dependent regulation of vascular tone in vivo J Appl Physiol, July 1, 2006; 101(1): 10 - 11. [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP |