|
|
||||||||
1Dipartimento di Anestesia e Rianimazione, Università di Torino, Ospedale S. Giovanni Battista-Molinette, Torino; 2Divisione di Pneumologia, Fondazione Salvatore Maugeri, IRCCS, Istituto Scientifico di Veruno, Veruno (NO); and 3Servizio di Anestesia e Rianimazione, Azienda Ospedaliera CTO-CRF-Maria-Adelaide, Torino, Italy
Submitted 8 December 2004 ; accepted in final form 11 May 2005
The helmet, a transparent latex-free polyvinyl chloride cylinder linked by a metallic ring to a soft collar that seals the helmet around the neck, has been recently proposed as an effective alternative to conventional face mask to deliver pressure support ventilation (PSV) during noninvasive ventilation in patients with acute respiratory failure. We tested the hypothesis that mechanical characteristics of the helmet (large internal volume and high compliance) might impair patient-ventilator interactions compared with standard face mask. Breathing pattern, CO2 clearance, indexes of inspiratory muscle effort and patient-ventilator asynchrony, and dyspnea were measured at different levels of PSV delivered by face mask and helmet in six healthy volunteers before (load-off) and after (load-on) application of a linear resistor. During load-off, no differences in breathing pattern and inspiratory muscle effort were found. During load-on, the use of helmet to deliver pressure support increased inspiratory muscle effort and patient-ventilator asynchrony, worsened CO2 clearance, and increased dyspnea compared with standard face mask. Autocycled breaths accounted for 12 and 25% of the total minute ventilation and for 10 and 23% of the total inspiratory muscle effort during mask and helmet PSV, respectively. We conclude that PSV delivered by helmet interface is less effective in unloading inspiratory muscles compared with PSV delivered by standard face mask. Other ventilatory assist modes should be tested to exploit to the most the potential benefits offered by the helmet.
face mask; patient-ventilator interactions
This article has been cited by other articles:
![]() |
N. Ambrosino and G. Vagheggini Noninvasive positive pressure ventilation in the acute care setting: where are we? Eur. Respir. J., April 1, 2008; 31(4): 874 - 886. [Abstract] [Full Text] [PDF] |
||||
![]() |
R Bolton and A Bleetman Non-invasive ventilation and continuous positive pressure ventilation in emergency departments: where are we now? Emerg. Med. J., April 1, 2008; 25(4): 190 - 194. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Chiumello Is the Helmet Different Than the Face Mask in Delivering Noninvasive Ventilation? Chest, June 1, 2006; 129(6): 1402 - 1403. [Full Text] [PDF] |
||||
![]() |
O. Moerer, S. Fischer, M. Hartelt, B. Kuvaki, M. Quintel, and P. Neumann Influence of Two Different Interfaces for Noninvasive Ventilation Compared to Invasive Ventilation on the Mechanical Properties and Performance of a Respiratory System: A Lung Model Study Chest, June 1, 2006; 129(6): 1424 - 1431. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| Visit Other APS Journals Online |