Journal of Applied Physiology Add DOIs to your references at manuscript stage!
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 99: 624-633, 2005. First published March 24, 2005; doi:10.1152/japplphysiol.00748.2004
8750-7587/05 $8.00
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow All Versions of this Article:
99/2/624    most recent
00748.2004v1
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via ISI Web of Science (4)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Seurynck, S. L.
Right arrow Articles by Johnson, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Seurynck, S. L.
Right arrow Articles by Johnson, M.

Optical monitoring of bubble size and shape in a pulsating bubble surfactometer

Shannon L. Seurynck,1 Nathan J. Brown,1 Cindy W. Wu,1 Kevin W. Germino,2 Ellen K. Kohlmeir,1 Edward P. Ingenito,3 Matthew R. Glucksberg,2 Annelise E. Barron,1 and Mark Johnson2

1Department of Chemical and Biological Engineering and 2Department of Biomedical Engineering, Northwestern University, Evanston, Illinois; and 3Respiratory Division, Brigham and Women’s Hospital, Boston, Massachusetts

Submitted 16 July 2004 ; accepted in final form 22 March 2005

The pulsating bubble surfactometer (PBS) is often used for in vitro characterization of exogenous lung surfactant replacements and lung surfactant components. However, the commercially available PBS is not able to dynamically track bubble size and shape. The PBS therefore does not account for bubble growth or elliptical bubble shape that frequently occur during device use. More importantly, the oscillatory volume changes of the pulsating bubble are different than those assumed by the software of the commercial unit. This leads to errors in both surface area and surface tension measurements. We have modified a commercial PBS through the addition of an image-acquisition system, allowing real-time determination of bubble size and shape and hence the accurate tracking of surface area and surface tension. Compression-expansion loops obtained with the commercially available PBS software were compared with those provided by the image-analysis system for dipalmitoylphosphatidylcholine, Infasurf, and Tanaka lipids (dipalmitoylphosphatidylcholine-palmitoyloleoylphosphatidyl-glycerol-palmitic acid, 68:22:9) at concentrations of 0.1 and 1.0 mg/ml and at frequencies of 1 and 20 cycles/min. Whereas minimum surface tension as determined by the image-analysis system is similar to that measured by the commercially available software, the maximum surface tension and the shapes of the interfacial area-surface tension loops are quite different. Differences are attributable to bubble drift, nonsinusoidal volume changes, and variable volume excursions seen with the modified system but neglected by the original system. Image analysis reveals that the extent of loop hysteresis is greatly overestimated by the commercial device and that an apparent, rapid increase in surface tension upon film expansion seen in PBS loops is not observed with the image-analysis system. The modified PBS system reveals new dynamic characteristics of lung surfactant preparations that have not previously been reported.

surface tension; dynamic; adsorption; lipids; surfactometry; lung surfactant; dipalmitoylphosphatidylcholine



Address for reprint requests and other correspondence: M. Johnson, Northwestern Univ., Dept. of Biomedical Engineering, 2145 Sheridan Rd., Evanston, IL 60208 (E-mail: m-johnson2{at}northwestern.edu)