Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 96: 1505-1515, 2004. First published December 12, 2003; doi:10.1152/japplphysiol.01047.2003
8750-7587/04 $5.00
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow All Versions of this Article:
96/4/1505    most recent
01047.2003v1
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (24)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Farina, D.
Right arrow Articles by Camelia, F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Farina, D.
Right arrow Articles by Camelia, F.

HIGHLIGHTED TOPICS
Neural Control of Movement

Low-threshold motor unit membrane properties vary with contraction intensity during sustained activation with surface EMG visual feedback

Dario Farina, Marco Gazzoni, and Federico Camelia

Laboratorio di Ingegneria del Sistema Neuromuscolare, Dipartimento di Elettronica, Politecnico di Torino, Torino 10129, Italy

Submitted 29 September 2003 ; accepted in final form 4 December 2003

Single-motor unit (MU) activities were detected from the abductor pollicis and abductor digiti minimi muscles providing the subjects with visual feedback of multichannel surface electromyogram (EMG) signals. The subjects could modulate the force to observe on the surface recordings a single dominant MU and modulate its firing rate for contractions of 300 s with a noninvasive EMG feedback. The firing rate was maintained at ~8 pulses per second [low-frequency (LF) contraction] and at ~12 pulses per second [high-frequency (HF) contraction]. Single-MU conduction velocity (CV) decreased slightly but significantly over time, and it was possible to identify a significantly larger rate of decrease of CV during the HF with respect to the LF contractions. CV initial value significantly increased with the average firing rate, and CV values were significantly correlated to the instantaneous firing rate (R ranging from 0.21 to 0.39). Both additional MU recruitment and substitution were observed during the contractions. The study provides evidence that 1) it is possible to follow the same MU in a hand muscle at two different intensities (HF and LF) for 300-s durations by using visual feedback of surface EMG, 2) low-threshold single-MU CV changes over time since the beginning of the contraction, and 3) it is possible to distinguish between CV changes of the same MU at slightly different firing rates. The technique provides a practical method for the noninvasive assessment of both control and membrane properties of single MUs.

firing rate; muscle fiber conduction velocity; linear electrode arrays; motor unit control; electromyogram



Address for reprint requests and other correspondence: D. Farina, Dipartimento di Elettronica, Politecnico di Torino, Corso Duca degli Abruzzi 24, Torino 10129, Italy (E-mail: dario.farina{at}polito.it).




This article has been cited by other articles:


Home page
J. Neurophysiol.Home page
D. Farina and D. Falla
Discharge Rate of Sternohyoid Motor Units Activated With Surface EMG Feedback
J Neurophysiol, February 1, 2009; 101(2): 624 - 632.
[Abstract] [Full Text] [PDF]


Home page
J. Neurophysiol.Home page
D. Farina, A. Holobar, M. Gazzoni, D. Zazula, R. Merletti, and R. M. Enoka
Adjustments Differ Among Low-Threshold Motor Units During Intermittent, Isometric Contractions
J Neurophysiol, January 1, 2009; 101(1): 350 - 359.
[Abstract] [Full Text] [PDF]


Home page
J. Neurophysiol.Home page
D. Farina, F. Negro, M. Gazzoni, and R. M. Enoka
Detecting the Unique Representation of Motor-Unit Action Potentials in the Surface Electromyogram
J Neurophysiol, September 1, 2008; 100(3): 1223 - 1233.
[Abstract] [Full Text] [PDF]


Home page
J. Neurophysiol.Home page
D. Farina, M. Pozzo, M. Lanzetta, and R. M. Enoka
Discharge Variability of Motor Units in an Intrinsic Muscle of Transplanted Hand
J Neurophysiol, May 1, 2008; 99(5): 2232 - 2240.
[Abstract] [Full Text] [PDF]


Home page
J. Neurophysiol.Home page
M. Gazzoni, F. Camelia, and D. Farina
Conduction Velocity of Quiescent Muscle Fibers Decreases During Sustained Contraction
J Neurophysiol, July 1, 2005; 94(1): 387 - 394.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
D. Farina, L. Arendt-Nielsen, and T. Graven-Nielsen
Effect of temperature on spike-triggered average torque and electrophysiological properties of low-threshold motor units
J Appl Physiol, July 1, 2005; 99(1): 197 - 203.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
D. Farina, M. Gazzoni, and F. Camelia
Conduction velocity of low-threshold motor units during ischemic contractions performed with surface EMG feedback
J Appl Physiol, April 1, 2005; 98(4): 1487 - 1494.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
D. Farina, L. Arendt-Nielsen, and T. Graven-Nielsen
Spike-triggered average torque and muscle fiber conduction velocity of low-threshold motor units following submaximal endurance contractions
J Appl Physiol, April 1, 2005; 98(4): 1495 - 1502.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
D. Farina, L. Arendt-Nielsen, and T. Graven-Nielsen
Experimental muscle pain reduces initial motor unit discharge rates during sustained submaximal contractions
J Appl Physiol, March 1, 2005; 98(3): 999 - 1005.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
G. C. Sieck
Commentary
J Appl Physiol, April 1, 2004; 96(4): 1504 - 1504.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online
Copyright © 2004 by the American Physiological Society.