INNOVATIVE METHODOLOGY
1Department of Orthodontics, School of Dental Medicine, University of Freiburg, D-79106 Freiburg, Germany; 2Department of Clinical Neurophysiology, Institute of Neurology, University Medical Centre Nijmegen, NL-6500 HB Nijmegen; and 3Interuniversity Institute for Fundamental and Clinical Human Movement Sciences, Amsterdam, Nijmegen, NL-1081 BT Amsterdam, The Netherlands
Submitted 15 May 2003 ; accepted in final form 29 August 2003
Although the value of high-density surface electromyography (sEMG) has already been proven in fundamental research and for specific diagnostic questions, there is as yet no broad clinical application. This is partly due to limitations of construction principles and application techniques of conventional electrode array systems. We developed a thin, highly flexible, two-dimensional multielectrode sEMG grid, which is manufactured by using flexprint techniques. The material used as electrode carrier (Polyimid, 50 µm thick) allows grids to be cut out in any required shape or size. One universal grid version can therefore be used for many applications, thereby reducing costs. The reusable electrode grid is attached to the skin by using specially prepared double-sided adhesive tape, which allows the selective application of conductive cream only directly below the detection surfaces. To explore the practical possibilities, this technique was applied in single motor unit analysis of the facial musculature. The high mechanical flexibility allowed the electrode grid to follow the skin surface even in areas with very uneven contours, resulting in good electrical connections in the whole recording area. The silverchloride surfaces of the electrodes and their low electrode-to-skin impedances guaranteed high baseline stability and a low signal noise level. The electrode-to-skin attachment proved to withstand saliva and great tensile forces due to mimic contractions. The inexpensive, universally adaptable and minimally obstructive sensor allows the principal advantages of high-density sEMG to be extended to all skeletal muscles accessible from the skin surface and may lay the foundation for more broad clinical application of this noninvasive, two-dimensional sEMG technique.
electrode array; single motor unit analysis; multichannel EMG; electromyography; facial muscles
This article has been cited by other articles:
![]() |
J P Weir, T W Beck, J T Cramer, T J Housh, T D Noakes, A St Clair Gibson, and E V Lambert Is fatigue all in your head? A critical review of the central governor model * Commentary. Br. J. Sports Med., July 1, 2006; 40(7): 573 - 586. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. G. Lapatki, R. Oostenveld, J. P. Van Dijk, I. E. Jonas, M. J. Zwarts, and D. F. Stegeman Topographical Characteristics of Motor Units of the Lower Facial Musculature Revealed by Means of High-Density Surface EMG J Neurophysiol, January 1, 2006; 95(1): 342 - 354. [Abstract] [Full Text] [PDF] |
||||