Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 95: 2345-2349, 2003; doi:10.1152/japplphysiol.00588.2003
8750-7587/03 $5.00
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via ISI Web of Science (2)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gouldstone, A.
Right arrow Articles by Loring, S. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gouldstone, A.
Right arrow Articles by Loring, S. H.

Stiffness of the pleural surface of the chest wall is similar to that of the lung

Andrew Gouldstone,1,2 Richard E. Brown,2 James P. Butler,1 and Stephen H. Loring2

1Physiology Program, Harvard School of Public Health, and 2Department of Anesthesia, Beth Israel Deaconess Medical Center, Boston, Massachussetts 02215

Submitted 6 June 2003 ; accepted in final form 18 August 2003

To address the role of the parietal pleura in reduction of mesothelial shear stresses during breathing, we measured the stiffness of the parietal pleural surface of mammalian chest walls using microindentation. The pleural surface was indented over ribs and intercostal spaces with rigid flat punches (tip radii of 0.01, 0.02, and 0.1 cm) to probe stiffness at length scales comparable with those of surface asperities. We found a tissue shear modulus of 6,700 dyn/cm2 and pleural membrane tension of 4,900 dyn/cm, with a geometric standard deviation of 0.42. These values are similar to those measured for the lung by Hajji et al., using indentation (Hajji MA, Wilson TA, and Lai-Fook SJ. J Appl Physiol Respirat Environ Exerc Physiol 47: 175–181, 1979). Surprisingly, the pleural surface over ribs and intercostal spaces exhibited similar stiffness. In addition, caudal regions exhibited lower stiffness than cranial regions. In the context of elastohydrodynamic lubrication, these results suggest that shear-induced pressures during breathing deform the chest wall and lung surfaces to a similar extent, promoting spatial uniformity of pleural fluid thickness and reducing shear stresses.

pleural lubrication; pleural membrane; elastic moduli; indentation



Address for reprint requests and other correspondence: S. H. Loring, Dept. of Anesthesia, Beth Israel Deaconess Medical Center, 330 Brooline Ave., Boston, MA 02215 (E-mail: sloring{at}bidmc.harvard.edu).







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online
Copyright © 2003 by the American Physiological Society.