Journal of Applied Physiology Watch the video to learn how APS reaches out to developing nations.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 94: 860-868, 2003. First published November 15, 2002; doi:10.1152/japplphysiol.00719.2002
8750-7587/03 $5.00
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow All Versions of this Article:
94/3/860    most recent
00719.2002v1
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (12)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Eckmann, D. M.
Right arrow Articles by Lomivorotov, V. N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Eckmann, D. M.
Right arrow Articles by Lomivorotov, V. N.
Vol. 94, Issue 3, 860-868, March 2003

Microvascular gas embolization clearance following perfluorocarbon administration

David M. Eckmann1 and Vladimir N. Lomivorotov2

1 Department of Anesthesia and Institute for Medicine and Engineering, The University of Pennsylvania, Philadelphia, Pennsylvania 19104-4283; and 2 Anesthesiology Department, Research Institute of Circulation Pathology, Novosibirsk 630055, Russia

Effective treatment of vascular gas embolism may be possible with emulsified fluorocarbon compounds. We tested the hypothesis that a fluorocarbon emulsion delivered before gas embolization would enhance bubble motion through the vasculature, favoring more rapid clearance. Air microbubbles were injected into the rat cremaster microcirculation in six groups of rats receiving Perftoran, an emulsified fluorocarbon, or saline immediately before, 2 h before, or after bubble injection. Embolism dimensions and dynamics were observed by using intravital microscopy. Surface area at lodging was equal between groups. Bubbles having smaller volume embolized smaller diameter vessels in the Perftoran pretreatment groups. A higher incidence of bubble dislodgement and larger distal displacement occurred in these two groups, with a 36% decrease in the time to bubble clearance and restoration of blood flow. Intravascular emulsified fluorocarbon administration before gas embolization affected initial bubble conformation, increased bubble dislodgement, and resulted in bubble displacement further into the periphery of the microcirculation. These dynamic events did not occur if embolization preceded fluorocarbon administration.

fluorocarbon; bubble; cremaster; microcirculation; reperfusion


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
B. D. Spiess
Perfluorocarbon emulsions as a promising technology: a review of tissue and vascular gas dynamics
J Appl Physiol, April 1, 2009; 106(4): 1444 - 1452.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
K. Yoshitani, F. de Lange, Q. Ma, H. P. Grocott, and G. B. Mackensen
Reduction in Air Bubble Size Using Perfluorocarbons During Cardiopulmonary Bypass in the Rat
Anesth. Analg., November 1, 2006; 103(5): 1089 - 1093.