Journal of Applied Physiology Watch the video to learn how APS reaches out to developing nations.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 93: 469-478, 2002. First published April 19, 2002; doi:10.1152/japplphysiol.01010.2001
8750-7587/02 $5.00
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow All Versions of this Article:
93/2/469    most recent
01010.2001v1
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (8)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Russ, D. W.
Right arrow Articles by Binder-Macleod, S. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Russ, D. W.
Right arrow Articles by Binder-Macleod, S. A.
Vol. 93, Issue 2, 469-478, August 2002

Factors in fatigue during intermittent electrical stimulation of human skeletal muscle

David W. Russ1, Krista Vandenborne2, and Stuart A. Binder-Macleod3,4

1 Department of Exercise Science, University of Massachusetts, Amherst, Massachussetts 01003; 2 Department of Physical Therapy, University of Florida, Gainesville, Florida 32611; and 3 Departments of Physical Therapy and 4 Biomechanics and Movement Science, University of Delaware, Newark, Delaware 19716

During an electrically elicited isometric contraction, the metabolic cost of attaining is greater than of maintaining force. Thus fatigue produced during such stimulation may not simply be a function of the force-time integral (FTI), as previously suggested. The goal of the present study was to evaluate fatigue produced in human medial gastrocnemius by intermittent, isometric electrical stimulation with trains of different frequencies (20, 40, or 80 Hz) and durations (300, 600, or 1,200 ms) that produced different peak forces and FTIs. Each subject (n = 10) participated in a total of six sessions. During each session, subjects received a pre- and postfatigue testing protocol and a different, 150-train fatiguing protocol. Each fatiguing protocol used only a single frequency and duration. The fatigue produced by the different protocols was correlated to the initial peak force of the fatiguing protocols (r2= 0.74-0.85) but not to the initial or total FTI. All of the protocols tested produced a proportionately greater impairment of force in response to low- vs. high-frequency stimulation (i.e., low-frequency fatigue). There was no effect of protocol on low-frequency fatigue, suggesting that all the protocols produced comparable levels of impairment in excitation-contraction coupling. These results suggest that, for brief stimulated contractions, peak force is a better predictor of fatigue than FTI, possibly because of the different metabolic demands of attaining and maintaining force.

force-time integral; excitation-contraction coupling


This article has been cited by other articles:


Home page
Exp PhysiolHome page
S. P. Cairns, D. M. Robinson, and D. S. Loiselle
Double-sigmoid model for fitting fatigue profiles in mouse fast- and slow-twitch muscle
Exp Physiol, July 1, 2008; 93(7): 851 - 862.
[Abstract] [Full Text] [PDF]


Home page
Exp PhysiolHome page
D. W. Russ and R. M. Lovering
Influence of activation frequency on cellular signalling pathways during fatiguing contractions in rat skeletal muscle
Exp Physiol, November 1, 2006; 91(6): 957 - 966.
[Abstract] [Full Text] [PDF]


Home page
Exp PhysiolHome page
T. Kesar and S. Binder-Macleod
Effect of frequency and pulse duration on human muscle fatigue during repetitive electrical stimulation
Exp Physiol, November 1, 2006; 91(6): 967 - 976.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
T. Muraoka, T. Muramatsu, T. Fukunaga, and H. Kanehisa
Influence of tendon slack on electromechanical delay in the human medial gastrocnemius in vivo
J Appl Physiol, February 1, 2004; 96(2): 540 - 544.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
J. L. Darques, D Bendahan, M Roussel, B Giannesini, F Tagliarini, Y Le Fur, P. J. Cozzone, and Y Jammes
Combined in situ analysis of metabolic and myoelectrical changes associated with electrically induced fatigue
J Appl Physiol, October 1, 2003; 95(4): 1476 - 1484.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online