J Appl Physiol 90: 1882-1886, 2001;
8750-7587/01 $5.00
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (5)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Assad, R. S.
Right arrow Articles by Hanley, F. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Assad, R. S.
Right arrow Articles by Hanley, F. L.
Vol. 90, Issue 5, 1882-1886, May 2001

Placental compliance during fetal extracorporeal circulation

R. S. Assad, F. Y. Lee, and F. L. Hanley

Department of Cardiovascular Surgery, The Children's Hospital, Harvard Medical School, Boston, Massachusetts 02115

The fetus requires large amounts of volume when weaning from cardiac bypass. This suggests that placental vasculature can act as a large capacitor in the fetal circulation. To assess placental compliance of fetal lambs, seven isolated in situ lamb placentas were placed on extracorporeal circulation. Umbilical artery blood flow was varied from 0 to 350 ml · min-1 · kg fetal wt-1. Because the extracorporeal circuit is a closed system, volume changes in the placenta induced by umbilical artery pressure changes were measured from reciprocal volume changes in the reservoir. There was a wide range of change in absolute volume of blood within the fetal placental compartment (216.4 ± 29.3 ml). Placental compliance was linear over the entire range of pressure changes exerted on the placental vasculature (r2 = 0.83, P = 0.0001). This indicates that the placenta is a unique and sensitive capacitor in the fetal circulation. This information is important clinically because it establishes that aggressive resuscitation of the fetus using volume may be necessary when weaning the fetus from cardiac bypass.

fetal cardiac surgery; fetal cardiac bypass; regional blood flow; placental hemodynamics; placental compliance


This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
R. S. Baker, C. T. Lam, E. A. Heeb, and P. Eghtesady
Dynamic fluid shifts induced by fetal bypass.
J. Thorac. Cardiovasc. Surg., March 1, 2009; 137(3): 714 - 722.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
C. T. Lam, S. Sharma, R. S. Baker, J. Hilshorst, J. Lombardi, K. E. Clark, and P. Eghtesady
Fetal Stress Response to Fetal Cardiac Surgery
Ann. Thorac. Surg., May 1, 2008; 85(5): 1719 - 1727.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
Y. Oishi, M. Masuda, T. Yasutsune, N. Boku, S. Tokunaga, S. Morita, and H. Yasui
Impaired Endothelial Function of the Umbilical Artery After Fetal Cardiac Bypass
Ann. Thorac. Surg., December 1, 2004; 78(6): 1999 - 2003.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online