Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 89: 1787-1792, 2000;
8750-7587/00 $5.00
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (5)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Darquenne, C.
Right arrow Articles by Prisk, G. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Darquenne, C.
Right arrow Articles by Prisk, G. K.
Vol. 89, Issue 5, 1787-1792, November 2000

Effect of gravity on aerosol dispersion and deposition in the human lung after periods of breath holding

Chantal Darquenne1, Manuel Paiva2, and G. Kim Prisk1

1 Department of Medicine, University of California, San Diego, La Jolla, California 92093-0931; and 2 Biomedical Physics Laboratory, Université Libre de Bruxelles, 1070 Brussels, Belgium

To determine the extent of the role that gravity plays in dispersion and deposition during breath holds, we performed aerosol bolus inhalations of 1-µm-diameter particles followed by breath holds of various lengths on four subjects on the ground (1G) and during short periods of microgravity (µG). Boluses of ~70 ml were inhaled to penetration volumes (Vp) of 150 and 500 ml, at a constant flow rate of ~0.45 l/s. Aerosol concentration and flow rate were continuously measured at the mouth. Aerosol deposition and dispersion were calculated from these data. Deposition was independent of breath-hold time at both Vp in µG, whereas, in 1G, deposition increased with increasing breath hold time. At Vp = 150 ml, dispersion was similar at both gravity levels and increased with breath hold time. At Vp = 500 ml, dispersion in 1G was always significantly higher than in µG. The data provide direct evidence that gravitational sedimentation is the main mechanism of deposition and dispersion during breath holds. The data also suggest that cardiogenic mixing and turbulent mixing contribute to deposition and dispersion at shallow Vp.

aerosol bolus; cardiogenic mixing


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
C. Darquenne and G. K. Prisk
Effect of small flow reversals on aerosol mixing in the alveolar region of the human lung
J Appl Physiol, December 1, 2004; 97(6): 2083 - 2089.
[Abstract] [Full Text] [PDF]


Home page
J Clin PharmacolHome page
A. Graebe, E. L. Schuck, P. Lensing, L. Putcha, and H. Derendorf
Physiological, Pharmacokinetic, and Pharmacodynamic Changes in Space
J. Clin. Pharmacol., August 1, 2004; 44(8): 837 - 853.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online