Journal of Applied Physiology Ad Instruments
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 89: 961-966, 2000;
8750-7587/00 $5.00
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (12)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mitragotri, S.
Right arrow Articles by Langer, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mitragotri, S.
Right arrow Articles by Langer, R.
Vol. 89, Issue 3, 961-966, September 2000

Analysis of ultrasonically extracted interstitial fluid as a predictor of blood glucose levels

Samir Mitragotri1, Matthew Coleman2, Joseph Kost3,4,5, and Robert Langer4

1 Department of Chemical Engineering, University of California, Santa Barbara, California 93106; 2 Department of Chemical Engineering, University of Colorado, Boulder, Colorado 80302-7077; 3 Department of Chemical Engineering, Ben Gurion University, Beer Sheeva 84105, Israel; 4 Department of Chemical Engineering, Massachusetts Institute of Technology, and 5 Sontra Medical, Cambridge, Massachusetts 02139-4307

Transdermal extraction of clinically relevant analytes offers a potentially noninvasive method of diagnostics. However, development of such a method is limited by the low permeability of skin. In this paper, we present a potential method for noninvasive diagnostics based on ultrasonic skin permeabilization and subsequent extraction of interstitial fluid (ISF) across the skin using vacuum. ISF extracted by this method was collected and analyzed for glucose and other analytes. Glucose concentration in the extracted fluid correlates well with blood glucose concentration over a range of 50-250 mg/dl. A mathematical model describing vacuum-induced transport of ISF through ultrasonically permeabilized skin is presented as well. The model accounts for convective, as well as diffusive, transport processes across blood capillaries, epidermis, and the stratum corneum. The overall predictions of the model compare favorably with the experimental observations.

diabetes; diagnostics; sonophoresis; noninvasive


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
D. D. Cunningham, T. P. Henning, E. B. Shain, D. F. Young, J. Hannig, E. Barua, and R. C. Lee
Blood extraction from lancet wounds using vacuum combined with skin stretching
J Appl Physiol, March 1, 2002; 92(3): 1089 - 1096.