Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 88: 966-972, 2000;
8750-7587/00 $5.00
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (14)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Muenter, N. K.
Right arrow Articles by Smith, M. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Muenter, N. K.
Right arrow Articles by Smith, M. L.
Vol. 88, Issue 3, 966-972, March 2000

Effect of sleep restriction on orthostatic cardiovascular control in humans

N. K. Muenter, D. E. Watenpaugh, W. L. Wasmund, S. L. Wasmund, S. A. Maxwell, and M. L. Smith

Department of Integrative Physiology, University of North Texas Health Science Center, Fort Worth, Texas 76107

We hypothesized that sleep restriction (4 consecutive nights, 4 h sleep/night) attenuates orthostatic tolerance. The effect of sleep restriction on cardiovascular responses to simulated orthostasis, arterial baroreflex gain, and heart rate variability was evaluated in 10 healthy volunteers. Arterial baroreflex gain was determined from heart rate responses to nitroprusside-phenylephrine injections, and orthostatic tolerance was tested via lower body negative pressure (LBNP). A Finapres device measured finger arterial pressure. No difference in baroreflex function, heart rate variability, or LBNP tolerance was observed with sleep restriction (P > 0.3). Systolic pressure was greater at -60 mmHg LBNP after sleep restriction than before sleep restriction (110 ± 6 and 124 ± 3 mmHg before and after sleep restriction, respectively, P = 0.038), whereas heart rate decreased (108 ± 8 and 99 ± 8 beats/min before and after sleep restriction, respectively, P = 0.028). These data demonstrate that sleep restriction produces subtle changes in cardiovascular responses to simulated orthostasis, but these changes do not compromise orthostatic tolerance.

blood pressure; lower body negative pressure; heart rate variability; arterial baroreflex; partial sleep deprivation


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
S. M. Grenon, S. Hurwitz, N. Sheynberg, X. Xiao, B. Judson, C. D. Ramsdell, C. Kim, R. J. Cohen, and G. H. Williams
Sleep restriction does not affect orthostatic tolerance in the simulated microgravity environment
J Appl Physiol, November 1, 2004; 97(5): 1660 - 1666.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
H. K. Meier-Ewert, P. M. Ridker, N. Rifai, M. M. Regan, N. J. Price, D. F. Dinges, and J. M. Mullington
Effect of sleep loss on C-Reactive protein, an inflammatory marker of cardiovascular risk
J. Am. Coll. Cardiol., February 18, 2004; 43(4): 678 - 683.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
C. GUILLEMINAULT, J. L. FAUL, and R. STOOHS
Sleep-disordered Breathing and Hypotension
Am. J. Respir. Crit. Care Med., October 1, 2001; 164(7): 1242 - 1247.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online