Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 87: 2366-2374, 1999;
8750-7587/99 $5.00
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pfister, R. E.
Right arrow Articles by Berger, P. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pfister, R. E.
Right arrow Articles by Berger, P. J.
Vol. 87, Issue 6, 2366-2374, December 1999

SPECIAL COMMUNICATION
Errors in estimating lung liquid volume in fetal lambs when using radiolabeled serum albumin and blue dextran

Riccardo E. Pfister1, C. Andrew Ramsden1,2, Heather L. Neil2, Mary A. Kyriakides1, and Philip J. Berger1

1 Ritchie Centre for Baby Health Research, Institute of Reproduction and Development, and 2 Department of Paediatrics, Monash University, Monash Medical Centre, Clayton, Victoria 3168, Australia

Fetal lung liquid volume is usually determined by using radio-iodinated serum albumin (RISA) or blue dextran (BD) as volume tracers. We tested the reliability of both tracers at 124 (G124) and 142 days of gestation (G142; term = G147) when the labels were employed simultaneously. We measured the proportion of label bound reversibly to the lung, or apparently lost from the lung compartment, by washing out the lung with saline and 5% albumin. At G124, volume estimates with the two labels were similar. At G142, the volume estimate with BD (36.3 ± 8.7 ml/kg of body wt) was higher (P < 0.05) than with RISA (22.3 ± 3.5 ml/kg). This difference resulted from reversible binding of BD, because 5% albumin washout released 38.5 ± 4.0% of the BD added at the start of the experiment but a lesser amount of RISA (9.8 ± 0.7%; P < 0.05). At G142, when RISA was used alone, its reversible binding was 1.3 ± 0.2%. Background absorbance increased during experiments, giving rise to an apparent increase in BD concentration. We conclude that RISA is an effective tracer for lung liquid volume determination in the fetal lamb, whereas our findings of substantial epithelial binding of BD and large changes in background absorbance demonstrate that, under the conditions of our experiments, BD is a poor tracer close to term.

fetal lamb; radioiodinated serum albumin; volume tracer


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
R. C. Dukarm, R. H. Steinhorn, J. A. Russell, S. Lakshminrusimha, D. Swartz, and J. J. Cummings
Selective type 5 phosphodiesterase inhibition alters pulmonary hemodynamics and lung liquid production in near-term fetal lambs
J Appl Physiol, December 1, 2005; 99(6): 2331 - 2336.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
R. E. Pfister, M. A. Kyriakides, P. J. Berger, C. A. Ramsden, S. Cassin, and A. M. Perks
Measuring lung liquid volume and secretion using radioiodinated serum albumin and blue dextran
J Appl Physiol, March 1, 2003; 94(3): 1293 - 1294.
[Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
S. Cassin and A. M. Perks
Estimation of lung liquid production in fetal sheep with blue dye dextran and radioiodinated serum albumin
J Appl Physiol, April 1, 2002; 92(4): 1531 - 1538.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online