Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 87: 1546-1554, 1999;
8750-7587/99 $5.00
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kessler, V.
Right arrow Articles by Guttmann, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kessler, V.
Right arrow Articles by Guttmann, J.
Vol. 87, Issue 4, 1546-1554, October 1999

SPECIAL COMMUNICATION
Interrupter airway and tissue resistance: errors caused by valve properties and respiratory system compliance

Volker Kessler1, Georg Mols1, Holger Bernhard1, Christoph Haberthür2, and Josef Guttmann1

1 Section of Experimental Anesthesiology, Department of Anesthesiology and Critical Care Medicine, University of Freiburg, 79106 Freiburg, Germany; and 2 Division of Clinical Physiology, Clinic of Cardiac and Thoracic Surgery, University Hospital, 4031 Basel, Switzerland

The interrupter technique is used to determine airway and tissue resistance. Their accuracy is influenced by the technical properties of the interrupter device and the compliance of the respiratory system. We investigated the influence of valve characteristics and respiratory system compliance on the accuracy of determining airway and tissue resistance by means of a computer simulation. With decreasing compliance we found increasing errors in both airway and tissue resistance determination of up to 34 and 71%, respectively. On this basis we developed a new occlusion valve, with special emphasis on rapid closing time and tightness in the closed state to improve the accuracy of resistance determination. The newly developed occlusion device greatly improves the accuracy of airway and tissue resistance determination. We conclude that respiratory system compliance is a limiting factor for the accuracy of the interrupter technique. To apply the interrupter technique in patients with extremely low respiratory system compliances, we need sophisticated technical devices.

computer simulation; initial pressure drop; interrupter technique; respiratory system mechanics


This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
N. Beydon, S. D. Davis, E. Lombardi, J. L. Allen, H. G. M. Arets, P. Aurora, H. Bisgaard, G. M. Davis, F. M. Ducharme, H. Eigen, et al.
An Official American Thoracic Society/European Respiratory Society Statement: Pulmonary Function Testing in Preschool Children
Am. J. Respir. Crit. Care Med., June 15, 2007; 175(12): 1304 - 1345.
[Full Text] [PDF]


Home page
Br J AnaesthHome page
G. Mols, V. Kessler, A. Benzing, M. Lichtwarck-Aschoff, K. Geiger, and J. Guttmann
Is pulmonary resistance constant, within the range of tidal volume ventilation, in patients with ARDS?
Br. J. Anaesth., February 1, 2001; 86(2): 176 - 182.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
Q. LU, A. CAPDEROU, P. CLUZEL, E. MOURGEON, L. ABDENNOUR, J.-D. LAW-KOUNE, C. STRAUS, P. GRENIER, M. ZELTER, and J.-J. ROUBY
A Computed Tomographic Scan Assessment of Endotracheal Suctioning-Induced Bronchoconstriction in Ventilated Sheep
Am. J. Respir. Crit. Care Med., November 1, 2000; 162(5): 1898 - 1904.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online