|
|
||||||||
1 Center for Environmental Medicine and Lung Biology, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599; 2 GSF-National Research Center for Environment and Health, Institute for Inhalation Biology, D-85758 Neuherberg/Munich, Germany; and 3 Human Studies Division, National Health and Environmental Effects Research Laboratory, US Environmental Protection Agency, Research Triangle Park, North Carolina 27771
The regional deposition of particles in boluses delivered to shallow lung depths and their subsequent retention in the airways may depend on the lung volume at which the boluses are delivered. To evaluate the effect of end-inspiratory lung volume on aerosol bolus delivery, we had healthy subjects inhale radiolabeled, monodisperse aerosol (99mTc-iron oxide, 3.5-µm mass median aerodynamic diameter) boluses (40 ml) to a volumetric front depth of 70 ml into the lung at lung volumes of 50, 70, and 85% of total lung capacity (TLC) end inhalation. By gamma camera analysis, we found significantly greater deposition in the left (L) vs. right (R) lungs at the 70 and 85% TLC end inhalation; ratio of deposition in L to R lung, normalized to L-to-R ratio of lung volume (mean L/R), was 1.60 ± 0.45 (SD) and 1.96 ± 0.72, respectively (P < 0.001 for comparison to 1.0) for posterior images. However, at 50% TLC, L/R was 1.23 ± 0.37, not significantly different from 1.0. These data suggest that the L and R lungs may be expanding nonuniformly at higher lung volumes. On the other hand, subsequent retention of deposited particles at 2 and 24 h postdeposition was independent of L/R at the various lung volumes. Thus asymmetric bolus ventilation for these very shallow boluses does not lead to significant increases in peripheral alveolar deposition. These data may prove useful for 1) designing aerosol delivery techniques to target bronchial airways and 2) understanding airway retention of inhaled particles.
aerosol deposition; aerosol bolus; inhaled particle retention
This article has been cited by other articles:
![]() |
W. Moller, K. Felten, K. Sommerer, G. Scheuch, G. Meyer, P. Meyer, K. Haussinger, and W. G. Kreyling Deposition, Retention, and Translocation of Ultrafine Particles from the Central Airways and Lung Periphery Am. J. Respir. Crit. Care Med., February 15, 2008; 177(4): 426 - 432. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. Moller, K. Haussinger, R. Winkler-Heil, W. Stahlhofen, T. Meyer, W. Hofmann, and J. Heyder Mucociliary and long-term particle clearance in the airways of healthy nonsmoker subjects J Appl Physiol, December 1, 2004; 97(6): 2200 - 2206. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Verbanck, D. Schuermans, W. Vincken, and M. Paiva Saline aerosol bolus dispersion. I. The effect of acinar airway alteration J Appl Physiol, May 1, 2001; 90(5): 1754 - 1762. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Verbanck Implications of Left-to-Right Lung Ventilation Heterogeneity J Appl Physiol, March 1, 2000; 88(3): 1150 - 1151. [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| Visit Other APS Journals Online |