Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 85: 2365-2369, 1998;
8750-7587/98 $5.00
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sherwood, A.
Right arrow Articles by Hutcheson, J. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sherwood, A.
Right arrow Articles by Hutcheson, J. S.
Vol. 85, Issue 6, 2365-2369, December 1998

SPECIAL COMMUNICATION
Ambulatory impedance cardiography: a feasibility study

Andrew Sherwood1, Judy McFetridge1, and J. Stanford Hutcheson2

1 Biobehavioral Research Laboratory, Department of Psychiatry and Behavioral Sciences, Duke University Medical Center, Durham 27710; and 2 Department of Psychiatry, University of North Carolina, Chapel Hill, North Carolina 27599

A wearable, ambulatory impedance monitor (AIM) has been developed to permit impedance cardiographic measurements while patients and volunteers engage in normal daily activities. The AIM system was developed for use with a new hybrid tetrapolar spot-band electrode configuration and was designed to be comfortable and inconspicuous. The objective of the present study was to provide a preliminary evaluation of AIM comparability with the widely validated Minnesota model 304B impedance cardiograph with standard tetrapolar band electrodes. Orthostatic challenge was used to systematically alter cardiac function in a laboratory setting in 11 healthy men and women. Both while the subjects were sitting and while they were standing, the AIM yielded measures of cardiac function, including heart rate, preejection period, left ventricular ejection time, and stroke volume, that were similar to those acquired by using the reference Minnesota 304B system (all Pearson R correlations > +0.87, all P < 0.001). Cardiac responses to postural shift, expressed as change measures from sitting to standing, were also comparable for the AIM and Minnesota reference monitoring systems. Potential applications, including the assessment of 24-h hemodynamic profiles, are illustrated and discussed.

ambulatory monitoring; cardiac function; preejection period; stroke volume; hemodynamics


This article has been cited by other articles:


Home page
Biol Res NursHome page
J. A. McFetridge-Durdle, F. S. Routledge, T. Sampalli, R. Fox, H. Livingston, and B. Adams
Hemodynamic Response to Postural Shift in Women with Multiple Chemical Sensitivities
Biol Res Nurs, January 1, 2009; 10(3): 267 - 273.
[Abstract] [PDF]


Home page
Psychosom. Med.Home page
T. G.M. Vrijkotte, L. J.P. van Doornen, and E. J. C. de Geus
Overcommitment to Work Is Associated With Changes in Cardiac Sympathetic Regulation
Psychosom Med, September 1, 2004; 66(5): 656 - 663.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
G. Cybulski

J Appl Physiol, April 1, 2000; 88(4): 1509 - 1510.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online