Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 84: 1447-1469, 1998;
8750-7587/98 $5.00
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Liu, C. H.
Right arrow Articles by Bidani, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Liu, C. H.
Right arrow Articles by Bidani, A.

Vol. 84, Issue 4, 1447-1469, April 1998

MODELING IN PHYSIOLOGY
Airway mechanics, gas exchange, and blood flow in a nonlinear model of the normal human lung

C. H. Liu1, S. C. Niranjan2,3,4, J. W. Clark Jr.2,3, K. Y. San1, J. B. Zwischenberger2,5
A. Bidani(With the Technical Assistance of H. B. Winnike, C. Vanouye, and J. B. Olansen)2,4

Departments of 1 Chemical Engineering and 3 Electrical and Computer Engineering, Rice University, Houston, 77251; and 2 Biomedical Engineering Center, Departments of 4 Internal Medicine and 5 Thoracic Surgery, University of Texas Medical Branch, Galveston, Texas 77555

A model integrating airway/lung mechanics, pulmonary blood flow, and gas exchange for a normal human subject executing the forced vital capacity (FVC) maneuver is presented. It requires as input the intrapleural pressure measured during the maneuver. Selected model-generated output variables are compared against measured data (flow at the mouth, change in lung volume, and expired O2 and CO2 concentrations at the mouth). A nonlinear parameter-estimation algorithm is employed to vary selected sensitive model parameters to obtain reasonable least squares fits to the data. This study indicates that 1) all three components of the respiratory model are necessary to characterize the FVC maneuver; 2) changes in pulmonary blood flow rate are associated with changes in alveolar and intrapleural pressures and affect gas exchange and the time course of expired gas concentrations; and 3) a collapsible midairway segment must be included to match airflow during a forced expiration. Model simulations suggest that the resistances to airflow offered by the collapsible segment and the small airways are significant throughout forced expiration; their combined effect is needed to adequately match the inspiratory and expiratory flow-volume loops. Despite the limitations of this lumped single-compartment model, a remarkable agreement with airflow and expired gas concentration measurements is obtained for normal subjects. Furthermore, the model provides insight into the important dynamic interactions between ventilation and perfusion during the FVC maneuver.

ventilation; perfusion; convective-diffusion transfer; parameter estimation; pulmonary function testing


This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
K. Lu, J. W. Clark Jr., F. H. Ghorbel, C. S. Robertson, D. L. Ware, J. B. Zwischenberger, and A. Bidani
Cerebral autoregulation and gas exchange studied using a human cardiopulmonary model
Am J Physiol Heart Circ Physiol, February 1, 2004; 286(2): H584 - H601.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
K. Lu, J. W. Clark Jr., F. H. Ghorbel, D. L. Ware, and A. Bidani
A human cardiopulmonary system model applied to the analysis of the Valsalva maneuver
Am J Physiol Heart Circ Physiol, December 1, 2001; 281(6): H2661 - H2679.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online