Journal of Applied Physiology Information on EB 2010
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 84: 862-867, 1998;
8750-7587/98 $5.00
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Peslin, R.
Right arrow Articles by Duvivier, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Peslin, R.
Right arrow Articles by Duvivier, C.

Vol. 84, Issue 3, 862-867, March 1998

Evaluation of a forced oscillation method to measure thoracic gas volume

R. Peslin and C. Duvivier

Unité 14 de Physiopathologie Respiratoire, Institut National de la Santé et de la Recherche Médicale, Université H. Poincaré Nancy I, 54500 Vandoeuvre-les-Nancy, France

The purpose of this study was to test a plethysmographic method of measuring thoracic gas volume (TGV) that, contrary to the usual panting method, would not require any active cooperation from the subject. It is based on the assumption that the out-of-phase component of airway impedance varies linearly with frequency. By using that assumption, TGV may be computed by combining measurements of total respiratory impedance (Zrs) and of the relationship between the plethysmographic signal (Vpl) and airway flow (V) during forced oscillations at several frequencies. Zrs and Vpl/V were measured at 10 noninteger multiple frequencies ranging from 4 to 29 Hz in 15 subjects breathing gas in nearly BTPS conditions. Forced oscillation measurements were immediately followed by determination of TGV by the standard method. The data were analyzed on different frequency ranges, and the best agreement was seen in the 6- to 29-Hz range. Within that range, forced oscillation TGV and standard TGV differed little (3.92 ± 0.66 vs. 3.83 ± 0.73 liters, n = 77, P < 0.05) and were strongly correlated (r = 0.875); the differences were not correlated to the mean of the two estimates, and their SD was 0.35 liter. In seven subjects the differences were significantly different from zero, which may, in part, be due to imperfect gas conditioning. We conclude that the method is not highly accurate but could prove useful when, for lack of sufficient cooperation, the panting method cannot be used. The results of computer simulation, however, suggest that the method would be unreliable in the presence of severe airway inhomogeneity or peripheral airway obstruction.

respiratory mechanics methods; plethysmography; respiratory impedance


JAP 84(3):862-867
0161-7567/98 $5.00 Copyright © 1998 the American Physiological Society